INDEX
H. Specifications
Introductions -------------------------- 1
A.
B. Features --------------------------------- 1
C. The Panel and Shape ---------------- 2
D. The LCD Display ---------------------- 3
E. Operation Instructions --------- 4 ~ 6
F. Calibration Tables -------------------- 7
G. Precaution ------------------------------ 8
H. Specifications ------------------------- 9
Measurement range
5.5 ~ 99.9% (Digital LCD Display)
(% WME)
±1% (difference as the testing
Accuracy (at 25°C)
materials.)
Resolution 0.1%
Operating Range -10 ~ +50°C (with temp. compensated)
No. of wood
8 (choose form “MODE” key)
calibration scales
Sampling rate Approx. 1 reading/Sec.
Auto/Manual turn off, Hold function,
Record Maximum & Minimum values,
Main Functions
Built-in Calibrator, Wood Calibration
Scales, Low Battery warning.
Power Supply 9V Battery × 1 pc or AC Adaptor (option)
Battery Life Approx. 250 hours (continues)
Meter 168 × 73 × 33 mm (6.6 ×3.0×1.3 inch)
Dimensions
Probe L: 120 mm, Cable: 1.2 meter (Pin Type)
Weight Approx. 180g, (6.3 oz) including battery
Option Accessories
1. Roller Type Moisture Probe(No.7012)
2. AC Adaptor ………..………(No.7019)
3. Extension 0f Electrodes pin (No.701P)
5cm ~ 20cm