BYM10-50 THRU BYM10-1000
SOLDERABLE ENDS
1st BAND
0.022 (0.56)
0.018 (0.46)
0.205 (5.2)
0.185(4.7)
D1=
0.105
0.095
(2.67)
(2.41)
D2 = D1
+ 0
- 0.008 (0.20)
1st band denotes type and positive end (cathode)
D2
GL41A THRU GL41Y
SURFACE MOUNT GLASS PASSIVATED JUNCTION RECTIFIER
Reverse Voltage - 50 to 1600 Volts Forward Current - 1.0 Ampere
DO213AB
FEATURES
♦ Plastic package has Underwriters Laboratory
Flammability Classification 94V-0
2nd BAND
♦ Capable of meeting environmental standards of
MIL-S-19500
PATENTED*
♦ For surface mount applications
♦ High temperature metallurgically bonded construction
♦ Glass passivated cavity-free junction
♦ High temperature soldering guaranteed:
450°C/5 seconds at terminals. Complete device
submersible temperature of 265°C for 10 seconds
in solder bath
2nd band denotes voltage type
Dimensions in inches and (millimeters)
*
Patent No.3,996,602 and brazed-end cap assembly by Patent No. 3,930,306
Glass-plastic encapsulation technique is covered by
Case: JEDEC DO-213AB molded plastic over glass body
Terminals: Plated ter minals, solderable per MIL-STD-750,
Method 2026
MECHANICAL DATA
Polarity: Two bands indicate cathode-end -1st band
denotes device type and 2nd band denotes repetitive peak
reverse voltage rating
Mounting Position: Any
Weight: 0.0046 ounce, 0.116 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
BYM10 BYM10
Standard recovery device: 1st band is white
Polarity color bands (2nd Band) Gray Red Orange Yellow Green Blue Violet White Brown
Maximum repetitive peak reverse voltage V
Maximum RMS voltage V
Maximum DC blocking voltage V
Maximum average forward rectified current
(SEE FIG. 1)
Peak forward surge current
8.3ms single half sine-wave superimposed
on rated load (JEDEC Method)
Maximum instantaneous forward voltage at 1.0A V
Maximum DC reverse current T
at rated DC blocking voltage T
=25°C 10.0
A
=125°C
A
Maximum full load reverse current
full cycle average at T
Typical junction capacitance
Typical thermal resistance
Operating junction and storage temperature range T
NOTES:
(1) Measured at 1.0 MH
(2) Thermal resistance from junction to ambient, 0.24 x 0.24” (6.0 x 6.0mm) copper pads to each terminal
(3) Thermal resistance from junction to terminal, 0.24 x 0.24” (6.0 x 6.0mm) copper pads to each terminal
=75°C
A
(NOTE 1)
(NOTE 2)
(NOTE 3)
and applied reverse voltage of 4.0 V
Z
SYMBOLS -50 -100 -200 -400 -600 -800 -1000 UNITS
RRM
RMS
I
(AV)
I
FSM
I
I
R(AV)
C
R
ΘJA
R
ΘJT
, T
J
DC
GL41A GL41B GL41D GL41G GL41J GL41K GL41M GL41T GL41Y
50 100 200 400 600 800 1000 1300 1600 Volts
35 70 140 280 420 560 700 910 1120 Volts
DC
50 100 200 400 600 800 1000 1300 1600 Volts
1.0 Amp
30.0 Amps
F
R
1.1 1.2 Volts
50.0
30.0 µA
J
8.0 pF
75.0
30.0
STG
-65 to +175 °C
µA
°C/W
25 50 75 100 125 150 175
0
0.25
0.5
0.75
1.0
110100
0
5.0
10
15
20
25
30
110100
1
10
30
0.4 0.6 0.8 1.0 1.2 1.4 1.6
0.01
0.1
1
10
0 20406080100
0.01
0.1
1
10
0.01 0.1 1 10 100
0.1
1
10
100
RATINGS AND CHARACTERISTIC CURVES BYM10-50 THRU BYM10-600 / GL41A THRU GL41Y
FIG. 2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
TJ=TJmax.
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
GL41A - M
FIG. 1 - FORWARD CURRENT DERATING CURVE
GL41A THRU
GL41M
GL41T THRU
AMPERES
GL41Y
60 H
Z
RESISTIVE OR
INDUCTIVE LOAD
AMPERES
AVERAGE FORWARD RECTIFIED CURRENT,
TERMINAL TEMPERATURE, °C
FIG. 3 - TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
GL41A-J
AMPERES
INSTANTANEOUS FORWARD CURRENT,
GL41K-Y
TJ=25°C
PULSE WIDTH=300µs
1% DUTY CYCLE
PEAK FORWARD SURGE CURRENT,
NUMBER OF CYCLES AT 60 H
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
TJ=100°C
Z
MICROAMPERES
INSTANTANEOUS REVERSE CURRENT,
PERCENT OF RATED PEAK REVERSE VOLTAGE, %
TJ=25°C
INSTANTANEOUS FORWARD VOLTAGE,
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
VOLTS
TJ=25°C
f=1.0 MH
Z
Vsig=50mVp-p
JUNCTION CAPACITANCE, pF
REVERSE VOLTAGE, VOLTS
FIG. 6 - TYPICAL TRANSIENT THERMAL IMPEDANCE
MOUNTED ON 0.20 x 0.27” (5 x 7mm)
COPPER PAD AREAS
TRANSIENT THERMAL IMPEDANCE (°C/W)
t, PULSE DURATION, sec