General Electric pt9051slss, pt9051blts Specification Sheet - Download

PT9051SL/BL
ADA
COMPLIANT
Recommended cutout location from floor
32-1/2"
Cutout height
27-1/4" MIN. 27-5/16" MAX.
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
23" minimum
door opening allowance
F
Conduit
40"
D
22"
9-1/2" MAX.
Cutout depth 23-1/2" MIN
Junction box location
22" to
bottom of
junction box
E
B
A
C
Recommended cutout location from floor
32-1/2"
Cutout height
27-1/4" MIN. 27-5/16" MAX.
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
30''
PT9051
30"
1 1/4"
11/16"
1 1/4"
27 3/16"
28 3/8" 29 3/4"
Cabinet A - Overlap of oven at top of cutout B - Overlap of oven other side of edge of cutout C - Overlap of oven at bottom of cutout Oven D - Install depth E - Overall height with trim F - Overall width
C
L
Suitable
bracing
to support
runners
2 x 4 or equivalent runners level with bottom of cutout and flush with sides of cutout or solid bottom floor
(must support 200 lbs.)
Recommended cutout location from floor
32-1/2"
Cutout height
27-1/4" MIN. 27-5/16" MAX.
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
23" minimum
door opening allowance
F
Conduit
40"
D
22"
9-1/2" MAX.
Cutout depth 23-1/2" MIN
Junction box location
22" to
bottom of
junction box
E
30''
B
A
C
PT9051
30"
1 1/4"
11/16"
1 1/4"
27 3/16"
28 3/8" 29 3/4"
Cabinet A - Overlap of oven at top of cutout B - Overlap of oven other side of edge of cutout C - Overlap of oven at bottom of cutout Oven D - Install depth E - Overall height with trim F - Overall width
Recommended cutout location from floor
32-1/2"
Cutout height
27-1/4" MIN. 27-5/16" MAX.
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
Cutout depth 23-1/2" MIN
Junction box location
22" to
bottom of
junction box
30''
GE Profile
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
MOST 30" WALL CABINETS CAN BE USED WITH THIS UNIT.
NOTE: These ovens are not approved
for stackable installations. Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets and drawers on adjacent 45° and 90° walls should be placed to avoid interference with the handle.
Electric wall ovens are not approved for installation with a plug and receptacle. They must be hard wired in accordance with installation instructions.
INSTALLATION I N FORMATI O N : Before installing, consult installation instructions packed with product for current dimensional data.
Side-by-side installations rerquire at least 2" between cutouts.
KW R ATI N G
240V 4.5
208V 3.4
BREAKER SIZE
24 0V 20 Amps
208V 20 Amps
Series 30 in. Built-In Single Convection Wall Oven
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Dimension and installation information are shown in inches.
Listed by Underwriters Laboratories
Speci fication Revised 11/17
PT9051SL/BL
25
Gas or electric cooktops may be installed over this oven. See cooktop installation instructions for cutout size. See label on top of oven for approved cooktop models.
Gas or electric connections for gas cooktop must be located in an adjacent accessible location to the right
240V / 208V Junction box location
36" Typical countertop height
24
4
"
Allow 1-1/4" top/bottom and 1" on sides for overlap
28 1/2" MIN. 28 5/8" MAX.
9-1/2"
27 1/4" MIN. 27 5/16" MAX.
3/4" Support platform required
Must Support 200 Lbs.
22" MIN. Above support platform
Side by Side single ovens
Side-by-Side Installations
Install two ovens in separate cutouts.
Center Line
Cutout - observe all dimensions and requirements.
Cutout - observe all dimensions and requirements.
Center Line
30" models
2
" MIN.
27" models
GE Profile
OPTIONAL UNDERCOUNTER DIMENSIONS AND INSTALLATION INFORMATION
NOTE: 36" ribbon cooktop are approved for use over GE 30" single wall ovens and warming drawers. 30" ribbon cooktops are approved for use over 30" and GE 27" single wall ovens and warming drawers. Refer to cooktop and wall oven installation information packed with products for current dimensional data.
NOTE: Door handle protrudes 3" from door face. Cabinets and drawers on adjacent 45° and 90° walls should be placed to avoid interference with the handle.
INSTALLATION I N FORMATI O N : Before installing, consult installation instructions packed with products for current dimensional data and for alternate installation options.
ELECTRIC WALL OVENS ARE NOT APPROVED FOR INSTALLATION WITH A PLUG AND RECEPTACLE. THEY MUST BE HARD WIRED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS.
Series 30 in. Built-In Single Convection Wall Oven
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 11/17
Loading...