General DTH04 User Manual

Page 1
Jumbo Display
In/Out
Temperature-Humidity
Meter with Clock
USER’S MANUAL
DTH04
99 Washington Street Melrose, MA 02176
Visit us at www.TestEquipmentDepot.com
Page 2
KEY FEATURES
• Triple readout shows time, inside or outside temperature, and inside or outside relative humidity (RH)
• Stores and recalls Min and Max temp and RH readings
• Warm, Comfortable and Cool indications
• °C/°F switch on back
• 12/24 hour alarm clock with 10 minute snooze option
• Includes flip-out stand, 9.8 ft. (3m) probe and batteries
2
Page 3
SETUP INSTRUCTIONS
Install Batteries:
1. Slide off cover of battery compartment on back of unit.
2. Install (2) included “AAA” batteries in compartment
in correct position.
3. Replace battery compartment cover.
OPERATING INSTRUCTIONS
ON/OFF:
1. Press
ON/OFF
and press again to power it off. “ “
COMFORT
combination of temperature and humidity.
°C/°F:
1. Press
unit.
Max/Min:
1. Press
temperature and humidity readings. on the display.
2. Press button again to recall minimum temperature
and humidity readings. display.
3. Unit reverts to real time mode automatically after
5 seconds.
Time Set:
1. Press and hold
Blinking digits on bottom readout means clock is in set mode.
button once to power on the meter
” or “
COOL
” appears at specific
°C/°F
button to select desired temperature
MAX/MIN
button once to recall maximum
MIN
TIME SET
WARM
will appear on the
button for 3 seconds.
3
”,
MAX
will appear
Page 4
2. Press HRand
MIN
buttons until the display shows
the current time.
3. Press
12/24
button to select time format.
4. Press
TIME SET
button to save setting and return to real time mode. If button is not pressed within 5 seconds, unit will not save new setting and will return to real time mode using previous setting.
In/Out:
1. Press
IN/OUT
button once to display outdoor
OUT
measurements.
will appear on the display.
2. Press button again to display indoor measurements.
IN
will will appear on the display.
Alarm Set:
1. Press and hold alarm set mode.
HR
2. Press
and
AL/SNZ
button for 3 seconds to enter
AL
will appear on the display.
MIN
buttons until display shows
desired alarm time.
3. Press
TIME SET
button again to save alarm setting and return to real time mode. If button is not pressed within 3 seconds, unit will not save new alarm setting and will return to real time mode.
Snooze Set:
1. After setting alarm time, press activate the alarm and snooze function. and signs will appear on the
display
AL/SNZ
.
button to
SNZ
2. After alarm/snooze function is activated, the unit will automatically return to real time mode in 3 seconds.
4
Page 5
3. When the set alarm time is reached, will flash and alarm will sound for 1 minute. Press any key to silence the alarm.
SNZ
4. 10 minutes after the alarm sounds, and the alarm will sound 5 times. Press any key to silence the alarm.
5. To clear the snooze function, press and hold the
AL/SNZ
button for 3 seconds to enter alarm set mode. Then press the The and
SNZ
AL/SNZ
indications will disappear.
button again.
will flash
SPECIFICATIONS
Temperature Measurement Range:
-32° to 122°F (0° to 50°C)
Temperature Measurement Accuracy: ±1.8°F (±1°C)
RH Measurement Range: 20 to 100%
RH Measurement Accuracy: ±6% of reading
Temperature & RH Resolutions:
0.1° (F or C), 0.1% RH
Digit Height: 0.67 in.
Display Window Size: 2.8 x 2.4 in. (71 x 61mm)
Dimensions: 3.9 x 4.1 x 0.9 in. (99 x 104 x 23mm)
Power Source: 2 “AAA” batteries (included)
5
Page 6
99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Specifications subject to change without notice
©2012 GENERAL TOOLS & INSTRUMENTS
NOTICE - WE ARE NOT RESPONSIBLE FOR
DTH04 User’s Manual
TYPOGRAPHICAL ERRORS.
MAN#DTH04 11/6/12