General ASH12A, ASH12ASGCW, AOH12ASGC, ASH9A, ASH9ASGCW User Manual

...
COOLING M ODE L
R OOM AIR CON DITIONE R
W A LL M OU NT E D T Y PE
Indoor U nit
AS H9A S GCW
OP E R AT IN G MA NUA L
AS H12AS G CW
AOH9A N G C AOH12A S GC
E nglis h
K E EP T HIS OPE RAT IO N M ANUAL FOR FUTURE R EF E R E N CE
FUJITSU GENERAL LIMITED
Fig. 1
Fig. 5
Fig. 2
Fig. 3
Fig. 6
Fig. 4
Fig. 7
Fig. 8
CONTENTS
SAFETY PRECAUTIONS .................................... En-1
FEATURES AND FUNCTIONS ........................... En-2
NAME OF PARTS ................................................ En-3
PREPARATION .................................................... En-4
OPERATION ........................................................ En-5
TIMER OPERATION ............................................ En-7
SLEEP TIMER OPERATION ................................ En-8
SAFETY PRECAUTIONS
Do not attempt to install this air conditioner by yourself.
DANGER!
This unit contains no user-serviceable parts. Always consult authorized service per­sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installa­tion of the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the circuit breaker, and consult authorized service personnel.
If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specified cord are required.
ADJUSTING THE DIRECTION OF
AIR CIRCULATION .............................................. En-9
SWING OPERATION ......................................... En-10
MANUAL AUTO OPERATION .......................... En-10
CLEANING AND CARE ..................................... En-11
TROUBLESHOOTING ....................................... En-12
OPERATING TIPS.............................................. En-13
CAUTION!
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor unit, take precautions to prevent access to
infants.
Do not use inflammable gases near the air conditioner.
En-1
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
Merely press the START/STOP button, and the unit will be­gin automatic operation in the Cooling or Dry mode as ap­propriate, in accordance with the thermostat setting and the actual temperature of the room.
SLEEP TIMER
When the SLEEP timer button is pressed during Cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.
SWING OPERATION
The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room.
REMOVABLE INTAKE GRILLE
The indoor unit’s INTAKE GRILLE can be removed for easy cleaning and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
SUPER QUIET OPERATION
When the FAN CONTROL button is used to select QUIET, the indoor unit’s airflow is reduced to produce quieter Cool­ing operation.
AIR CLEANING FILTER (Optional)
The optional Air Cleaning Filter (Model APS-03B) uses an electrostatic principle to clean the air of fine particulate matter such as tobacco smoke and plant pollen.
En-2
NAME OF PARTS
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 POWER Switch 3 MANUAL AUTO button
4 Remote Control Signal Receiver
5 Indicator Lamps (Fig. 3) 6 OPERATION Indicator Lamp (red) 7 TIMER Indicator Lamp (green)
If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a fault has occurred with the timer setting
(See Page 13 Auto Restart).
8 SWING Indicator Lamp (orange)
9 Intake Grille (Fig. 4) 0 Air Filter A Air Flow Direction Louver B Right-Left Louver
(behind Air Direction Louver)
C Drain Hose D Power Supply Plug E Power Supply Cord F Air Cleaning Filter (optional)
Fig. 5 Outdoor Unit
G Intake Port H Outlet Port I Pipe Unit
Fig. 6 Remote Control Unit
J SLEEP button K MASTER CONTROL button L SET TEMP./SET TIME buttons ( ) M Signal Transmitter N TIMER button O FAN CONTROL button P START/STOP button Q AIR FLOW DIRECTION button R SWING LOUVER button
Rear side (Fig. 7)
S TIME ADJUST button T ACL button
(located inside battery compartment)
U TEST RUN button
This button is used when installing the conditioner, and should not be used un­der normal conditions, as it will cause the air conditioners thermostat function to op­erate incorrectly.
If this button is pressed during normal op­eration, the unit will switch to test opera­tion mode, and the Indoor Units OPERA­TION indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.
To stop the test operation mode, either press the TEST button once again, or press the START/STOP button to stop the air con­ditioner.
V Remote Control Unit Display (Fig. 8) W Transmit Indicator X Clock Display Y Operating Mode Display Z Timer Mode Display [ Fan Speed Display \ Temperature Set Display ] Timer Set Indicator ^ Temperature Set Indicator
Refer to the fold-out page on the cover.
En-3
PREPARATION
Turn on the Power
Connect the Power Supply Plug (Fig. 1 D) to an electri-
1
cal outlet; in the case of a direct line connection, turn on the circuit breaker.
Set the POWER switch (Fig. 2 2) to ON.
2
Load Batteries (R03/LR03
Press and slide the battery compartment lid on the re-
1
verse side to open it.
Slide in the direction of the arrow while pressing the mark.
Insert batteries.
2
Be sure to align the battery polarities ( ) correctly.
Close the battery compartment lid.
××
× 2)
××
3
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed quickly and disposed of properly, either by placing in a public battery collection receptacle, or by returning to appropri­ate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the remote control units operating range becomes appre­ciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.
Set the Current time
Press the TIME ADJUST button (Fig. 7 S).
1
Use the tip of a ball-point pen or other small object to press the button.
Use the ( )SET TIME buttons (Fig. 6 L) to adjust
2
the clock to the current time.
button: Press to advance the time. button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
Press the TIME ADJUST button again.
3
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The Remote Control Unit must be pointed at signal receiver (Fig. 1 4) to operate
correctly.
Operating range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will
be heard.
If no beep is heard, press the Remote Control Unit button again.
Remote Control Unit Holder
Insert
Press in
Screws
1 Mount the Holder.
2 Set the Remote Control
Unit.
Slide up
Pull out
3 To remove the Remote
Control Unit (when use at hand).
En-4
OPERATION
To Select Mode Operation
Press the START/STOP button (Fig.6 P).
1
The Indoor Units OPERATION indicator lamp (red) (Fig. 3 6) will light. The air conditioner will start operating.
Press the MASTER CONTROL button (Fig.6 K) to se-
2
lect the desired mode.
Each time the button is pressed, the mode will change in the following order.
ss
AUTO COOL
t
FAN DRY
About three seconds later, the entire display will reappear.
To Set the Thermostat
Press the SET TEMP. buttons (Fig. 6 L).
button: Press to raise the thermostat setting. button: Press to lower the thermostat setting.
t
Example: When set to COOL.
Thermostat setting range:
AUTO .................................. Standard temperature setting ± 2 °C
Cooling/Dry ........................ 18-30 °C
FAN ..................................... 17-30 °C
(During use of FAN mode, if the thermostat is set at 17 °C or lower, the display will show -- and the fan will operate continuously, regardless of the room tempera­ture.)
About three seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.
To Set the Fan Speed
Press the FAN CONTROL button (Fig. 6 O).
Each time the button is pressed, the fan speed changes in the following order:
AUTO HIGH MED LOW QUIET
About three seconds later, the entire display will reappear.
When set to AUTO:
Cooling : As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.
Fan : The fan will operate at the optimum speed in accordance with the
room temperature in the vicinity of the indoor unit.
ssss
s
Example: When set to 26 °C.
Example: When set to AUTO.
When set to QUIET:
SUPER QUIET operation begins. The indoor unit’s airflow will be reduced for qui- eter operation.
SUPER QUIET operation cannot be used during Dry mode. (The same is true
when dry mode is selected during AUTO mode operation.)
Cooling performance will be reduced somewhat during SUPER QUIET operation.
To Stop Operation
Press the START/STOP button.
The OPERATION indicator lamp (red) (Fig. 3 6) will go out.
En-5
About Mode Operation
AUTO: Depending on the room temperature at the time operation begins, the
operating mode will be switched automatically as shown in the accompanying table. Also, depending on the operating mode, the room temperature set­ting will cause the “standard” temperature to be set as shown.
Actual Room Operating Mode Thermostat Setting Temperature (standard setting) 30 °C or above Cooling 27 °C 27 °C to 30 °C Cooling 26 °C 25 °C to 27 °C Dry 24 °C 23 °C to 25 °C Dry 22 °C Below 23 °C Dry 20 °C
The operating mode and standard thermostat settings are selected auto­matically when operation begins.
When automatic operation is initiated, the fan will run at very low speed for about one minute while the unit detects and selects the proper operating mode.
Once the operating mode has been set, the mode will not change even if the room temperature changes.
If the START/STOP button is pressed to recommence operation within two hours after stopping automatic operation, the unit will begin op­erating from the same mode as before.
During Cooling/Dry mode:
Set the thermostat to a temperature set­ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper­ate).
During Fan mode:
Fan operation begins when room tem­perature in the vicinity of the air condi­tioner rises above the set thermostat temperature; when the temperature drops, fan operation stops.
If the air emitted feels too cool, raise the thermostat setting.
Cooling: Use to cool your room.
Dry: Use for gently cooling while dehumidifying your room.
You cannot heat the room during Dry mode.
During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humid­ity.
The fan speed cannot be changed manually when Dry mode has been selected.
Fan: ● Use to circulate the air from ceiling area throughout your room when
using space heaters.
En-6
TIMER OPERATION
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 4).
To Use the ON timer or OFF timer
Press the START/STOP button (Fig. 6 P)
1
(if the unit is already operating, proceed to step 2).
The Indoor Units OPERATION indicator lamp (red) (Fig. 3 6) will light.
To Cancel the Timer
Use the TIMER button to select “TIMER RESET. The air conditioner will return to normal operation.
Press the TIMER button (Fig. 6 N) to select the OFF
2
timer or ON timer operation.
Each time the button is pressed the timer function changes in the follow­ing order:
s
RESET OFF ON
PROGRAM(OFF ON, OFF ON)
The indoor unit’s TIMER indicator lamp (green) (Fig. 3 7) will light.
s
s
t
Use the SET TIME buttons (Fig. 6 L) to adjust the de-
3
sired OFF time or ON time.
Set the time while the time display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Use the PROGRAM timer
Press the START/STOP button (Fig. 6 P)
1
(if the unit is already operating, proceed to step 2).
The Indoor Units OPERATION indicator lamp (red) (Fig. 3 6) will light.
Set the desired times for OFF timer and ON timer.
2
See the section To Use the ON timer or OFF timer to set the desired mode and times. About three seconds later, the entire display will reappear. The indoor unit’s TIMER indicator lamp (green) (Fig. 3 7) will light.
To Change the Timer Settings
Perform steps 2 and 3.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change the operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting, wait until the entire display reappears, then press the appropri­ate buttons to change to the operating condition desired.
To Cancel the Timer
Use the TIMER button to select “TIMER RESET. The air conditioner will return to normal operation.
To Change the Timer Settings
1.
Follow the instructions given in the section To Use the ON Timer or OFF Timer to se- lect the timer setting you wish to change.
2. Press the TIMER button to select either OFF ON or OFF ON.
Press the TIMER button (Fig. 6 N) to select the PRO-
3
GRAM timer operation (either OFF ON or OFF ON will display).
The display will alternately show OFF timer and ON timer, then change to show the time setting for the operation to occur first.
The PROGRAM timer will begin operation. (If the ON timer has been selected to operate first, the unit will stop operating at this point.)
About five seconds later, the entire display will reappear.
About the PROGRAM timer
The PROGRAM timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.
The first timer function to operate will be the one set nearest to the current time. The order of operation is indicated by the arrow in the Remote Control Unit’s display (OFF ON, or OFF ON).
One example of PROGRAM timer use might be to have the air conditioner auto­matically stop (OFF timer) after you go to sleep, then start (ON timer) automati­cally in the morning before you rise.
En-7
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change the operating condi­tions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting, wait until the entire display reap­pears, then press the appropriate buttons to change to the operating condition desired.
SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP timer
While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 J).
Both the indoor unit’s OPERATION indicator lamp (red) (Fig. 3 6) and the TIMER indicator lamp (green) (Fig. 3 7) will light.
To Change the Timer Settings
Press the SLEEP button (Fig. 6 J) once again and set the time using the SET TIME buttons (Fig. 6 L).
Set the time while the Timer Mode Display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Cancel the Timer:
Use the TIMER button to select “TIMER RESET. The air conditioner will return to normal operation.
To Stop the Air Conditioner During Timer Operation:
Press the START/STOP button.
About the SLEEP timer
To prevent excessive cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting in accord­ance with the time setting. When the set time has elapsed, the air conditioner completely stops.
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto­matically raised 1 °C every sixty minutes. When the thermo­stat has been raised a total of 2 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
1 hour
Set time
1 °C
2 °C
En-8
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Units AIR FLOW DIRECTION button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
Vertical Air Direction Adjustment
Press the AIR FLOW DIRECTION button (Fig. 6 Q).
Each time the button is pressed, the air direction range will change as follows:
1
2 3 4 5 6 7
Types of Air flow Direction Setting:
1,2,3,4 : During Cooling/Dry modes 1,2,3,4,5,6,7 : During Fan mode
The remote control unit’s display does not change.
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
During Fan mode : Downward flow 7
During AUTO mode operation, for the first minute after beginning operation, airflow will be horizontal 1; the air direction cannot be adjusted during this pe­riod.
DANGER!
Never place fingers or foreign objects inside the outlet ports, since the inter­nal fan operates at high speed and could cause personal injury.
Always use the remote control unit’s AIR FLOW DIRECTION button to adjust the vertical airflow louvers. Attempting to move them manually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.
During Cooling and Dry modes, do not move the vertical air direction louvers outside their proper operating range for the mode (1 - 4) and into the fan region (5 - 7); using the louvers in the fan region will cause moisture to condense near the air outlet, and wa­ter may drop onto the floor. During the Cooling/Dry modes, if the louvers are operated outside the range 1 - 4 for more than 30 minutes, they will be automatically returned to the 4 range.
When used in a room with infants, chil­dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.
Right-Left Adjustment
Adjust the Right-Left louvers.
Move the Right-Left louvers to adjust air flow in the direction you prefer.
Right-Left Louvers
knob
En-9
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To select SWING Operation
Press the SWING LOUVER button (Fig. 6 R).
The SWING indicator lamp (orange) (Fig. 3 8) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down.
To Stop SWING Operation
Press the SWING LOUVER button (Fig. 6 R) once again.
The SWING indicator lamp (orange) (Fig. 3 8) will go out. Airflow direction will return to the setting before swing was begun.
About Swing Operation
The range of swing is relative to the currently set airflow direction.
If the swing range is not as desired, use the Remote Con­trol Unit’s AIR FLOW DIRECTION button to change the range of swing.
During Cooling/Dry modes, if SWING Operation in con­tinued at the lowest (downward) range for more than 30 minutes, the unit will automatically switch the swing range to the horizontal flow range, to prevent the condensation of moisture on the outlet.
The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button (Fig. 2 3) on the main unit control panel.
To stop operation, press the MANUAL AUTO button once again, or set the POWER switch (Fig. 2 2) to OFF. (Controls are located inside the Intake Grille.)
When the air conditioner is operated with the controls on the Main Unit, it will operate under the same mode as the AUTO mode selected on the Re­mote Control Unit (see page 6).
The fan speed selected will be “AUTO and the thermostat setting will be standard.
En-10
CLEANING AND CARE
CAUTION!
Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord.
Be sure the Intake Grille (Fig. 1 9) is installed securely.
When removing and replacing the air filters, be sure not to touch the heat exchanger, as per-
sonal injury may result.
Cleaning the Intake Grille
1. Remove the Intake Grille.
1 Place your fingers at both lower ends of the grille
panel, and lift forward; if the Intake Grille seems to catch partway through its movement, continue lifting upward to remove.
2 Lift up the Intake Grille fully to remove.
Intake Grille
2. Clean with water.
Remove dust with a vacuum cleaner; wipe the unit with warm water, then dry with a clean, soft cloth.
Cleaning the Air Filter
1. Open the Intake Grille, and remove the Air Filter.
Lift up the air filters handle, disconnect the two lower tabs, and pull out.
Air filter handle
Hooks (two places)
2. Remove dust with a vacuum cleaner or by washing.
After washing, allow to dry thoroughly in a shaded place.
3. Replace the Air Filter and close the Intake Grille.
1 Align the sides of the air filter with the panel, and push
in fully, making sure the two lower tabs are returned properly to their holes in the panel.
3. Replace the Intake Grille.
1 Holding the Intake Grille horizontally, fasten the two
upper hooks on the unit.
Intake Grille
2 Press the Intake Grille down at the lower sides to close.
2 Close the intake grille.
(For purposes of example, the illustration shows the unit without Intake Grille installed.)
Dust can be cleaned from the Air Filter either with a
vacuum cleaner, or by washing the filter in a solution of mild detergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before reinstalling.
If dirt is allowed to accumulate on the Air Filter, air flow
will be reduced, lowering operating efficiency and increas­ing noise.
During periods of normal use, the Air Filters should be
cleaned every two weeks.
Hooks (two place)
When using the optional Air Cleaning Filter
Install the optional Air Cleaning Filter set (APS-03B) as instructed (installation instructions are furnished with the Air Clean­ing Filter set).
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.
When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.
En-11
TROUBLESHOOTING
WARNING!
Before requesting service, perform the following checks:
NORMAL
FUNCTION
Doesnt operate immedi­ately:
Noise is heard:
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the Power Supply Plug, and consult authorized service personnel. Merely turning off the units power switch will not completely disconnect the unit from the power source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to ensure that power is completely off.
Symptom
If the unit is stopped and then immediately started again, the com­pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
Whenever the Power Supply Plug is disconnected and then re­connected to a power outlet, the protection circuit will operate for about 3 minutes, preventing unit operation during that pe­riod.
During operation and immediately after stopping the unit, the sound of water flowing in the air conditioners piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.
Problem
See Page
Smells:
Mist or steam are emitted:
Airflow is weak or stops.
Some smell may be emitted from the Indoor Unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
During Cooling or Dry operation, a thin mist may be seen emitted from the Indoor Unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.
The fan may operate at very low speed during Dry operation or when the unit is monitoring the room’s temperature.
During SUPER QUIET operation, the fan will operate at very low speed.
5
5
En-12
TROUBLESHOOTING
CHECK ONCE
MORE
Symptom
Doesnt operate at all:
Poor Cooling performance:
The unit operates differently from the Remote Control Unit’s setting:
Items to check
Is the Power Supply Plug disconnected its outlet?
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the main POWER Switch set to the OFF position?
Is the timer operating?
Is the air filter dirty?
Air the air conditioners intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat)
correctly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright
sunlight to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room?
Is the unit set for SUPER QUIET operation?
Are the Remote Control Units batteries dead?
Are the Remote Control Units batteries loaded properly?
See Page
4
7-8
5
4
If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator Lamp (Fig. 3 7) flashes, immediately stop operation, disconnect the Power Supply Plug (Fig.1 D
), and consult authorized service personnel.
OPERATING TIPS
Operation and Performance
AUTO Restart
In Event of Power Interruption
The air conditioner power has been interrupted by a power failure. The air conditioner will then restart auto­matically in its previous mode when the power is restored.
Operated by setting before the power failure. Then, the Air Flow Direction Louvers will automatically change to their standard direction.
If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this (kind of timer fault occurs the TIMER Indicator Lamp (green) will flash (see Page. 3) ).
Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the Remote Control Unit to resume operation.
En-13
OPERATING TIPS
Temperature and Humidity Range
Cooling Mode
Outdoor temperature
Indoor temperature
If the air conditioner is used under higher temperature conditions than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath. (About 80% or more)
About 21 to 43 °C
About 18 to 32 °C
Drying Mode
About 21 to 43 °C
About 18 to 32 °C
En-14
Loading...