General ARG12F, ARG12FUAD, AOG12FSAJ, ARG12U, ARG12UUAD User Manual

...
OPERATING MANUAL
AIR CONDITIONER
DUCT TYPE
OPERATING MANUAL
BEDIENUNGSANLEITUNG
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
MANUAL DE INSTRUÇÕES
English
Deutsch
Français
KEEP THIS MANUAL FOR FUTURE REFERENCE
SUMOTUWETH FR
AM PM
369
12 15 18 21
SA
Español
Italiano
EλληvIkά
Русский
FUJITSU GENERAL LIMITED
P/N9373117018
Português
CONTENTS
SAFETY PRECAUTIONS................................................ 1
NAME OF PARTS ........................................................... 2
PREPARATORY OPERATION......................................... 3
OPERATION ................................................................... 3
TIMER FUNCTIONS ....................................................... 5
ON/OFF TIMER............................................................... 5
WEEKLY TIMER ............................................................. 6
TEMPERATURE SET BACK TIMER ............................... 8
OPERATING TIPS........................................................... 9
CARE AND MAINTENANCE........................................ 10
SELF-DIAGNOSIS ........................................................ 10
TROUBLESHOOTING .................................................. 11
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER!
WARNING!
CAUTION!
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.
When moving, consult authorized service personnel for disconnection and installation of the unit.
Do not become over-exposed to cold air by staying in the direct path of the air flow of the air conditioner
for extended periods of time.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by turning off the electrical breaker and so on.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker,
and consult authorized service personnel.
This mark indicates procedures which, if improperly performed, are most likely to result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user, or damage to property.
DANGER!
CAUTION!
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Turn off power source when not using the unit for extended periods.
Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter.
Connection valves become hot during Heating; handle with care.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
When restarting after a long period of disuse in the winter, turn the power switch on at least 12 hours
before starting the unit.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art
works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor units, take precautions to prevent access by infants.
Do not use inflammable gases near the air conditioner.
En-1
NAME OF PARTS
Remote controller
D
2
7 8
9 0
A B
SUMOTUWETH FR
369
12 15 18 21
CLOCK ADJUST
SET BACK
DELETE SET
DAY
DAY OFF
G F E
SA
H
I C
1
3
ENERGY
SAVE
THERMO SENSOR
4 5
6
1 Start/Stop Button 2 Set Temperature Button 3 Master Control Button 4 Fan Control Button 5 THERMO SENSOR Button 6 ENERGY SAVE Button 7 Timer Mode (CLOCK ADJUST)
Button
8 DAY (DAY OFF) Button 9 SET BACK Button 0 Set Time Button A DELETE Button
B SET Button C Operation Lamp D Timer and Clock Display E Operation Mode Display F Fan Speed Display G Operation Lock Display H Temperature Display I Function Display
Defrost Display Thermo Sensor Display Energy Save Display
En-2
PREPARATORY OPERATION
Set the current day and time
1
CLOCK ADJUST
Press the timer mode (CLOCK ADJUST) button for 2 seconds or more. The time display on the remote controller will flash.
3
DAY
2
DAY OFF
SU MO TU WE TH FR SA
Press the set time buttons to set the current time. Press repeatedly to adjust the current time in 1­minute increments. Press and hold to adjust the current time in 10-minute increments.
SUMOTUWETH FR
SA
ex. Monday 10:00
Press the DAY button and select the current day. A
appears around the selected day.
4
Press again to end.
OPERATION
Instructions relating to heating are applicable only to HEAT & COOL MODEL” (Reverse Cycle).
To start/stop operation
Press the start/stop button.
CLOCK ADJUST
To set the operation mode
Operation mode setting
Room temperature setting
Lower Raise
Fan speed setting
Operation lamp
Air conditioner ON: Lit brightly Air conditioner OFF: Not lit
Press the master control button to set the operation mode. If DRY is selected, the fan speed will be set to AUTO.
AUTO COOL DRY HEATFAN
Press the set temperature buttons to set the room temperature.
Temperature setting range
AUTO ............................................... 18 to 30 °C
COOL/DRY ....................................... 18 to 30 °C
HEAT ................................................ 16 to 30 °C
Press the fan control button to set the fan speed.
En-3
AUTO HIGH MED LOW