General ARG36F, ARG36FUAN, AOG36FNAXT, ARG36U, ARG36UUAN Technical Manual

...
R410A
5 . DUCT TYPE :  AR 36FUAN, AR 36UUAN  AR 45FUAN, AR 45UUAN
D2D009E/03
2006.05.30
5-1. FEATURE
FEATURES
Installation styles
Embedded in Ceiling
Hanging from Ceiling
Low static pressure mode function
When installed, normal middle static pressure mode, and low static pressure mode can be selected by switching over using DIP switch on the board in the control box. Therefore, these models can be op­erated under the wide range of conditions.
DUCT TYPE
AR36X - AR45X
DUCT TYPE
AR36X - AR45X
Slim & compact design
In the case of bottom suction type, as seen from lower rear part.
Control Box that has been convex shape is now united with main unit (DIP Switch is located on the internal substrate.)
One-touch operating and easy-to-install long-life filter (optional)
In addition to the slim height of 270 mm which is our sales point, further com­pactification is attained by reducing 65 mm from the width with the flanking control box embedded inside the chassis.
- (05 - 01) -
EASY MAINTENANCE
In the case of rear suction type, as seen from lower rear part.
Conventional model
1
3
4
New model
4
1
1.Control box
2.Fan casing
3.Fan
4.Motor
2
2
3
Bottom panel: 2 units
Large bottom panel: 1 unit
Structural improvement is attained by making the bottom panel two pieces, front and rear, and the internal fan casing is also made dismountable in two pieces namely, upper and lower ones. The motor and fan maintenance and dismounting can be made easily by removing the rear panel and lower part of the casing with the main chassis installed.
DUCT TYPE
AR36X - AR45X
DUCT TYPE
AR36X - AR45X
- (05 - 02) -
5-2. REMOTE CONTROLLER
5-2-1. WIRED REMOTE CONTROLLER
FEATURES
Various timer setup (ON / OFF / WEEKLY) are possible. Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
SUMOTUWETH FR SA
7
3126 9
15 18 21
When setting up a timer, operation mode and a temperature setup can be changed.
When a failure occurs,the error code is displayed. (Maximum of 16) Error indication.(A maximum of 16 error histories are memorizable.) Up to 16 indoor units can be simultaneously controlled.
Anti freeze and energy saving operation are possible. Easy installation with a slim shape with no boldge in the back.
The room temperature can be controlled by being detected the temperature accurately with built-in thermo sensor.
High performance and compact size
Three functions are combined in one unit.
Wired
remote
controller
Built-in timers
Weekly
timer
Setback timerWeekly timer
Setback
timer
Possible to set ON/OFF time to operate twice each day of the week.
DUCT TYPE
AR36X - AR45X
SUMOTUWETH FR SA
7
3126 9
15 18 21
Setup screen example (Set to Wednesday: 8:00 to 20:00.)
0 3 6 9 12 15 18 21 Time
Easy-to-understand time bar display
24°C
SUMOTUWETH FR SA
7
3126 9
15 1821
Screen after setup
Possible to set temperature for two time spans and for each day of the week.
SUMOTUWETH FR SA
3126 9
15 18 21
Setup screen example (Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
28°C
0 3 6 9 12 15 18 21 Time
DUCT TYPE
AR36X - AR45X
At "Weekly timer" + "Set back timer" setup
24°C
24°C 28°C 24°C
0 3 6 9 12 15 18 21 Time
28°C
Easy-to-understand operation Simple installation
Components are compatible with standard switch boxes. Flat back construction allows equipment to be installed wherever it is
Timer area
Operation area
needed.
[
Variable timer control
]
The operation/display sections are zoned accord­ing to time and operation, enabling variable pro­gramming to match application.
- (05 - 03) -
European switch box
JIS box
FUNCTIONS
1
START/STOP button
Pressed to start and stop operation.
Display
2 7 8
9
10
SUMOTUWETH FR
369
CLOCK ADJUST
SET BACK
DELETE SET
12 15 18 21
DAY
DAY OFF
SA
13
1 3
ENERGY
SAVE
THERMO SENSOR
4
6
2
Set temperature button
Selects the setting temperature.
3
Master control button
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
5
Energy save button
Turns the energy efficient mode on and off.
11
12
5
6
Thermo sensor
7
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER)
Set the current time.
8
Day (DAY OFF) button
Display panel
Temporarily cancels of one day timer.
9
Set back button
pressed select the set back timer.
14
15
1617 18
10
Set time button
Pessed to select the set back timer.
SUMOTUWETH FR
SA
11
Delete button
The schedule of a weekly timer is deleted.
369
DUCT TYPE
AR36X - AR45X
12 15 18 21
DUCT TYPE
12
Set button
1920
Sets the date, hour, minute and on-off time.
13
Operation lamp
AR36X - AR45X
Lights during operation and when the timer is on.
DIMENSION
[ Unit : mm ]
17
120
SUMOTUWETH FR
369
12 15 18 21
DAY
CLOCK ADJUST
DAY OFF
SET BACK
DELETE SET
Front View
120
SA
ENERGY
SAVE
THERMO SENSOR
SPECIFICATION
SIZE (H x W x D mm) 120 x 120 x 17
WEIGHT ( g ) 160
CABLE LENGTH ( m )
POWER ( V )
10
12
14
Timer and clock display
15
Operation mode display
16
Fan speed display
17
Central control display
18
Temperature display
19
Stand by display Indicates during the oil recovery and defrosting operation.
20
Energy save display
- (05 - 04) -
- (05 - 05) -
DUC
T TYPE
AR36
X -
A
R45
X
D
UCT TYPEAR36X - AR45X
5-3. SPECIFICATIONS
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CW B. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Standard static pressure : 100 Pa. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
COOLING TYPE HEAT PUMP TYPE COOLING TYPE HEAT PUMP TYPE
AR*36FUAN AR*36UUAN AR*45FUAN AR*45UUAN
AO*36FNAXT AO*36UNAXT AO*45FMAXT AO*45UMAXT
COOLING D C
kW
BTU/h
kW - 12.70 - 14.30
BTU/h - 43400 - 48800
COOLING RATED 3.85 3.60 4.38 4.38
HEATING RATED - 3.65 - 4.39
COOLING RATED 6.4 6.1
HEATING RATED - 6.2 - 7.7
A 37 37
COOLING 2.73 2.92
HEATING
-
3.48 - 3.26
l/h (pints/h)
High
Med
Low
Quiet
High 7000 6100
Low
High
Med
Low
Quiet
High
Low
Pa
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High
Med
Low
54 54/55 54 54/56
W
Rows x Stages
Fin Pitch
Coil Dimensions
Rows x Stages 1 x 54 2 x 54
Fin Pitch
Coil Dimensions
1134x900x
18.19
1134x900x36.38
342- 457V~50Hz
1134x900x36.38
4 x 14
294x1000x53.2
Corrugate fin
2 x 54
Alminum
1.40
1.30
3700
Permanent Starting Condenser
Copper tube
Alminum
Propeller x 2
275
67 x 2
SCROLL4442
40
3N~400V 50Hz
30 to 150
Sirocco x 2
DUCTED MODELS
10.50
12.70
35800
43300
30 to 150
Sirocco x 2
3 x 14
3000
1.40
1.30
43
41
39
OUTDOOR
Coil
Fin
294x1000x39.9
Copper tube
INDOOR
Alminum fin
TWIN-ROTARY
Permanent Starting Condenser
Alminum fin
Copper tube
275
67 x 2
3N~400V 50Hz
RATED
RECOMMENDED STATIC PRESSURE
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
OUTDOOR
POWER SOURCE
COOLING
HEATING
CAPACITY
Propeller x 2
INDOOR
OUTDOOR
TYPE
MODEL NAME
Fin
CURRENT MOISTURE REMOVAL
INDOOR
OUTPUT
STARTING CURRENT
COMPRESSOR
FAN TYPE x Q'ty
FAN MOTOR OUTPUT
W
dB(A)
mm
mm
STARTING METHOD
TYPE
Coil
HEAT EXCHANGER TYPE
7.7675 (8.8)
1800
2.90
1700
1600
6100
3.5 (6.2)
1750
1650
1550
-
AVAILABLE VOLTAGE RANGE
EUROPEAN ENERGY LABEL
EER
COP
kW/kW
RATED
INPUT POWER
kW
A
INDOOR
AIR
CIRCULATION
r.p.m
m3/h
OUTDOOR
FAN SPEED
INDOOR
OUTDOOR
-
1340
1280
1210
-
780
400
-
780
400-1370
1330
1270
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR 43 / 50 ( 95 / 110) 43 / 50 ( 95 / 110) 45 / 52 ( 99 / 115) 45 / 52 ( 99 / 115)
OUTDOOR 80 / 87 (176 / 192) 94 / 101 (207 / 223) 109 / 116 (240 / 256) 113 / 120 (249 / 265)
LIQUID
GAS
m
m
CHARGE g 2000 3200
COOLING
HEATING
-10 to 24 - -10 to 24
mm
30
R410A
270x1135x700
1165x900x330
300x1300x790
1305x1050x445
Galvanized steel sheet
Synthetic (POE oil)
FLARE
Ø9.52(3/8 inc.)
Ø19.05(3/4 inc.)
50 (chargeless:20m)
3400
0 to 43
WIRED
Steel
Outer diameter 38 / Inner diameter 36
Beige(10YR7.5/1.0NN)
WIRED
Steel
Outer diameter 38 / Inner diameter 36
30
R410A
Synthetic (POE oil)
0 to 43
50 (chargeless:20m)
Galvanized steel sheet
Beige(10YR7.5/1.0NN)
FLARE
1165x900x330
1305x1050x445
300x1,300x790
9.52(3/8 inc)
15.88(5/8 inc.)
REMOTE CONTROLLER
TYPEREFRIGERANT OIL
OPERATION(OUTDOOR)
?
REFRIGERANT
TYPE
270x1,135x700
CASING COLOR
mm
kg(lbs)
DIMENSIONS H ×W ×D
NET / GROSS
WEIGHT
NET
GROSS
DRAIN PIPE
MATERIAL
SIZE
PIPE
SIZE m m
CONNECTION METHOD
MAX HEIGHT
MAX LENGTH
5-4. DIMENSIONS
5-4-1. OUTDOOR UNIT
MODELS: AO 36F, AO 36U  : AO 45F, AO 45U
(Unit : mm)
Top view
Front view
DUCT TYPE
AR36X - AR45X
Side view
DUCT TYPE
AR36X - AR45X
Bottom view
MOUNTING POSITION
When there are obstacles at the back or front side.
When there are obstacles at the back and front sides.
When there are obstacles at the back, side(s), and top.
When there are obstacles at the back side with the installation of more than one unit.
100 mm or more
600 mm or more
100 mm
or more
100 to 300 mm *
- (05 - 06) -
600 to 1000 mm
250 mm or more
250
(
mm
Ser
v
ic
e
* If the space is larger than that is stated, the
condition will be the same as that there are no obstacles.
300 mm or more
or
m
s
or
pac
e
e)
250 mm or more
300 mm or more
5-4-2. INDOOR UNIT
MODELS: AR 36F, AR 36U  : AR 45F, AR 45U
Front view
DUCT TYPE
AR36X - AR45X
DUCT TYPE
AR36X - AR45X
Side view (L)
Side view (R)
Top view
Rear view
- (05 - 07) -
MOUNTING POSITION
MAINTENANCE HOLE
It shall be possible to install and remove the control box.
DUCT TYPE
AR36X - AR45X
It shall be possible to install and remove the control box, fan units and filter.
DUCT TYPE
AR36X - AR45X
WHEN USING A SQUARE DUCT
- (05 - 08) -
5-5. REFRIGERANT CIRCUIT
MODELS : AR 36F / AO 36F
DUCT TYPE
AR36X - AR45X
DUCT TYPE
AR36X - AR45X
MODELS : AR 36U / AO 36U
- (05 - 09) -
MODELS : AR 45F / AO 45F
DUCT TYPE
AR36X - AR45X
MODELS : AR 45U / AO 45U
DUCT TYPE
AR36X - AR45X
- (05 - 10) -
5-6. WIRING DIAGRAMS
5-6-1. OUTDOOR UNIT
MODEL : AO 36F
DUCT TYPE
AR36X - AR45X
0Hz
5
0V
0
4
3N
230V
z
H
0
5
DUCT TYPE
AR36X - AR45X
MODEL : AO 36U
3N
0Hz
5
0V
0
4
230V
- (05 - 11) -
z
H
0
5
MODEL : AO 45F
3N 400V 50Hz
DUCT TYPE
AR36X - AR45X
230V 50Hz
DUCT TYPE
AR36X - AR45X
MODEL : AO 45U
3N
0Hz
5
0V
0
4
230V
- (05 - 12) -
z
H
0
5
Loading...
+ 29 hidden pages