R410A
4 . CEILING TYPE :  AB 30LBAG, AB 36LBAG
D2D_AB009E/01
2006.01.27
4-1. FEATURE
MODELS : AB 30LBAG / AO 30LMBWL AB 36LBAG / AO 36LMBWL
FEATURES
CEILING TYPE AB30-36L
Installation
OPEN SPACE CONCEALED
Wide air flow
WALL MOUNTED
(for high-ceilinged room)
Fresh-air intake
Slender shape
A slender shape with curves harmonizes
Wide air flow
perfectly with the room interior.
Long-life filter
High efficiency long-life filter that extends the cleaning cycle up to 2 times that of the current model is standard.
INDOOR
Slender
OUTDOOR
CEILING TYPE AB30-36L
Filter
Double auto swing
VERTICAL HORIZONTAL
SWING
Others
Auto Restart Detachable and Washable Open Panel
SWING
4-2. REMOTE CONTROLLER
4-2-1.
FEATURES
CEILING TYPE AB30-36L
WIRELESS REMOTE CONTROLLER
Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are possible.
Four kinds of timers. Easy operation.
Easy to change transmission code (4 patterns) by button operation.
Built-in timers
Select from four different timer programs (On/Off/Program/Sleep).
Program timer
The program timer operates the ON and OFF timer once within a 24 hour period.
CEILING TYPE AB30-36L
Sleep timer
The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling and heating while sleeping.
Cooling operation/dry operation
When the sleep timer is set, the set temperature automatically rises 1 °C every hour. The set temperature can rise up to a maximum of 2 °C.
Timer setting
60min.
1 °C
2 °C
Heating operation
When the sleep timer is set, the set temperature automatically drops 1 °C every 30 minutes. The set temperature can drop to a maximum of 4 °C.
1 °C
2 °C
3 °C
4 °C
30min.
60min.
90min.
Timer setting
Easy operation
After code change
Mixed-up
• Code selector switch eliminates unit being wrongly switched. (Up to 4 codes can be set.)
A B C D
A B
C
D
•Wide and precise transmitting range.
1. Press the MASTER CONTROL button for more than five seconds to start the code change.
2. Press the (+) or (-) button to select the desired code.
A B C D
3. Press the MASTER CONTROL button again to end the code change.
FUNCTIONS
CEILING TYPE AB30-36L
Display
3
2
9
10
13
1
TEST
RUN
15
11
12
14
5
1
START/STOP button
Pressed to start and stop operation
64
2
Set temp./Set time buttons/Set remote controller custom code buttons
Sets the indoor temp./Sets the current time and on-off time /Set R.C. custom code
3
Master control button/
7
8
Selects the operating mode (AUTO, HEAT, FAN, COOL, DRY). Start/end R.C. custom code change. (Max. 4 types)
4
Sleep timer button
Pressed to select sleep timer.
5
Signal transmitter
6
Timer button
Pressed to select the timer mode. (OFF TIMER, ON TIMER, PROGRAM TIMER, TIMER RESET)
7
Fan control button
Selects the fan speed (AUTO, LOW, MED, HIGH).
8
Battery compartment lid
9
Air flow direction vertical set button
10
Air flow direction vertical swing button
Code change
CEILING TYPE AB30-36L
Display panel
16
17
18
SPECIFICATION
19
20
21
22
23
11
Air flow direction horizontal swing button
12
Air flow direction horizontal set button
13
Time adjust button
Sets the current time.
14
ACL button
Used when replacing batteries or change the code.
15
Test run button
Used when testing the air conditioner after installation.
16
Transmit indicator
17
Clock display
18
Master control display
19
Timer mode display
20
Fan speed display
21
Set temperature display
22
Timer set indicator
23
Temperature set indicator
SIZE (H x W x D mm) 160 x 56 x 20
WEIGHT ( g ) 120
ACCESSORY Holder
4-3. SPECIFICATIONS
AB 30LBAG AB 36LBAG
AO 30LMBWL AO 36LMBWL
Rows × Stages
Fin Pitch
Rows × Stages
Fin Pitch
CEILING MODELS
INVERTER HEAT PUMP
230V 50Hz
STARTING METHOD
FAN TYPE x Q'ty
FAN MOTOR OUTPUT
W
COMPRESSOR
TYPE
FAN SPEED COOL/HEAT
DRAIN PIPE
kg(lbs)
MATERIAL
SIZE
CONNECTION METHOD
SIZEmm WEIGHT
NET / GROSS
MAX HEIGHT
HEAT EXCHANGER TYPE
INDOOR
Coil
OUTDOOR
Coil
Fin
mm
mm
PIPE
REFRIGERANT REMOTE CONTROLLER TYPE
OPERATION(OUTDOOR)
°C
REFRIGERANT OIL
TYPE
TYPE
MAX LENGTH
CASING COLOR
DIMENSIONS H × W × D NET
dB(A)
OUTDOOR
mm
GROSS
NOISE LEVEL (SOUND PRESSURE)
COOL/HEAT
INDOOR
Fin
INDOOR
r.p.m
OUTDOOR STARTING CURRENT
kW/kW
MOISTURE REMOVAL
AIR CIRCULATION COOL/HEAT
INDOOR
m3/h
OUTDOOR
INPUT POWER
kW
CURRENT
A
POWER SOURCE
AVAILABLE VOLTAGE RANGE
CAPACITY
COOLING
RATED/MAX
HEATING
RATED/MAX
TYPE
MODEL NAME
INDOOR
OUTDOOR
-
198-264V 50Hz
-
3600 / 3800
-
850 / 900
-
SIROCCO × 4
PROPELLER × 1
160
103
DC TWIN ROTARY (INVERTER)
1300
Inverter
Copper tube
Aluminium
3 × 12
1.45
252 × 1350 × 39.9
Copper tube
Aluminium
2 × 38
1.3
798 × 900 × 36.38
White (5Y9/0.5NN)
Beige (10YR7.5/1.0NN)
240 × 1660 × 700
830 × 900 × 330
318 × 1800 × 790
970 × 1050 × 445
48 / 61 ( 106 / 134 )
64 / 70 ( 141 / 154 )
FLARE
9.52 ( 3 / 8 inc.)
15.88 ( 5 / 8 inc.)
50 (chargeless:15)
30
R410A
2200
ABS
Outer diameter 25.6 / Inner diameter 22.0
POE
-10 to 43
-10 to 24
WIRELESS
CEILING TYPE AB30-36L
EUROPEAN ENERGY LABEL COOLING C E
kW 8.50/10.00 10.0/11.20
BTU/h 29000/34100 34100/38200
kW 10.00/11.20 10.8/12.77
BTU/h 34100/38200 36900/43600
COOLING RATED/MAX 3.00/3.45 4.12/4.35
HEATING RATED/MAX 2.90/3.50 3.26/4.15
COOLING RATED/MAX 13.1/15.2 18.0/18.4
HEATING RATED/MAX 12.7/15.3 14.2/18.8
A 10 10
EER COOLING 2.83 2.43
COP HEATING 3.45 3.31
l/h (pints/h) 2.5 ( 5.3 ) 3.0 ( 6.3 )
High 1660 / 1660 1850 / 1850
Med 1500 / 1450 1660 / 1500
Low 1270 / 1150 1430 / 1270
Quiet
High
Low
High 1000 / 1000 1100 / 1100
Med 900 / 850 1000 / 900
Low 750 / 650 850 / 750
Quiet
High
Low
INDOOR
OUTDOOR
INDOOR
OUTDOOR
High 45.0 / 45.0 48.0 / 48.0
Med 42.0 / 42.0 45.0 / 45.0
Low 37.0 / 37.0 41.0 / 41.0
53.0 / 55.0 54.0 / 55.0
CEILING TYPE AB30-36L
OUTPUT W
Coil Dimensions
Coil Dimensions
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
INDOOR
OUTDOOR
LIQUID
GAS
CHARGE g
COOLING
HEATING
m
m
Note: Specifications are based on the following conditions. Cooling: Indoor temperature of 27 °CDB / 19 °CWB,and outdoor temperature of 35 °CDB/24 °CWB. Heating: Indoor temperature of 20 °CDB / 15 °CWB,and outdoor temperature of 7 °CDB/6 °CWB. Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
mm
4-4. DIMENSIONS
4-4-1. OUTDOOR UNIT
CEILING TYPE AB30-36L
MODELS : AO 30L, AO 36L
Top view
830
21
Front view
900
9
650
Air flow
(Unit : mm)
77
31 330
400
12
CEILING TYPE AB30-36L
Side view
370
MOUNTING POSITION
When there are obstacles at the back or front sides.
100 mm or more
600 mm or more
100 mm or more
603
Bottom view
When there are obstacles at the back, side(s), and top.
600 mm or more
300 mm
250
(
mm or
S
er
v
i
c
e s
more
pac
e)
or more
196
99
147
170
When there are obstacles at the back, side with the installation of more than one unit.
250 mm or more
250 mm or more
300 mm or more
4-4-2. INDOOR UNIT
CEILING TYPE AB30-36L
MODELS : AB 30L, AB 36L
6
Side view
Rear view
(Unit : mm)
45
CEILING TYPE AB30-36L
1 2 3
Bottom view
Suspension bolt pitch
30 30
INDOOR UNIT (TOP VIEW)
INDOOR UNIT
1
Refrigerant piping flare connection (Gas)
2
Refrigerant piping flare connection (Liquid)
3
Drain piping connection (Drain pipe : I.D. 22 O.D. 25.6)
4
Knock out hole for fresh air
5
Knock out hole for refrigerant piping
1,600
Dimensions (Space Required for Installation)
10 155
300
Suspension bolt should extend outward 30 to 75.
6
Hole for lifting bolt (Use M10 screw bolt)
MOUNTING POSITION
Ceiling
INDOOR UNIT
(Unit : mm)
CEILING TYPE AB30-36L
80 or over 150 or over
Ceiling
10 or over
1000 or over
2300 or over
Obstruction
Floor
Ceiling panel
INDOOR UNIT
CEILING TYPE AB30-36L
80 or over 150 or over
Ceiling panel
10 or over
1000 or over
2300 or over
Obstruction
Floor
4-5. REFRIGERANT CIRCUIT
MODELS : AB 30L / AO 30L, AB 36L / AO 36L
CEILING TYPE AB30-36L
CEILING TYPE AB30-36L
4-6. WIRING DIAGRAMS
4-6-1. OUTDOOR UNIT
MODELS : AO 30L, AO 36L
CEILING TYPE AB30-36L
CEILING TYPE AB30-36L
TO POWER SUPPLY
TO INDOOR UNIT
Loading...
+ 21 hidden pages