Pre-Wired
Switch
Pre-Wired Automatic Transfer Switch
with Built-In Load Center
250 VAC, NEMA 1
Model RTG10EZA1 – 50 Amp, 10 Circuit Switch
Model RTG12EZA1 – 50 Amp, 12 Circuit Switch
Model RTG14EZA1 – 100 Amp, 14 Circuit Switch
Model RTG16EZA1 – 100 Amp, 16 Circuit Switch
Pre-Wired Switch
1 of 2
DESCRIPTION
The Generac pre-wired switch is designed to operate with 8-17kW air-cooled generators. This transfer switch has an integrated
load center for picking up the emergency circuits. It is especially useful where the main service is large and only a portion of the
building load will be served by the generator. It is available with a built-in 10, 12, 14 or 16-circuit load center to supply only those
circuits that are essential during an emergency. All standard and load center transfer switches are CUL Listed and suitable for use in
optional standby systems (NEC702).
STANDARD FEATURES
All pre-wired switches are housed in a steel NEMA 1 enclosure, with electrostatically applied and baked powder paint. The Heavy
Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the
timing, sensing and exercising functions.
CONTACTOR RATING
The transfer switch contactor is rated at 250 VAC and is available in a single phase configuration only.
50-100 Amps Pre-Wired Switch
Functions
All timing and sensing functions originate in the generator controller.
Pre-Wired Switch
Utility voltage drop-out ......................................................................................................................................................................................................................<60%
Timer to generator start ..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer*
Engine warm up delay ................................................................................................................................................................................................................. 5 seconds
2 of 2
Standby voltage sensor ..................................................................................................................................................................................................60% for 5 seconds
Utility voltage pickup .........................................................................................................................................................................................................................>80%
Re-transfer time delay ............................................................................................................................................................................................................... 15 seconds
Engine cool-down timer ............................................................................................................................................................................................................ 60 seconds
Exerciser .............................................................................................................................................................................................................. 12 minutes every 7 days
The transfer switch can be operated manually without power applied.
*When used in conjunction with units utilizing Evolution™ controls
Specifications
®
Model RTG10EZA1 RTG12EZA1 RTG14EZA1 RTG16EZA1
Voltage 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø
Amps 50 50 100 100
Circuits, 50A, 240V – – – 1
40A, 240V – 1 1 1
30A, 240V 1 1 – –
20A, 240V 1 – 1 1
20A, 120V 3 3 6 5
15A, 120V 3 5 4 5
Phase 1
Rated AC Frequency 60 Hz
Enclosure Material Steel
Enclosure Type NEMA 1
Withstand Rating (Amps) 10,000
Lug Range 1/0 - #14
Load Transition Type Open Transition
30' Whip Conductor Gauges (Hot, Neutral, Ground, Control) 8, 8, 10, 18 6, 6, 8, 18
Features
• Electrically operated, mechanically-held contacts for fast, positive connections.
• Rated for all classes of load, 100% equipment rated, both inductive and resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
Dimensions and Wire Ranges
Mechanical Dimensions
Amps
50*
100
*Note: The 50 Amp switch is flush mountable. H1 and W1 refer to mounting hole spacing.
H2 and W2 are cover dimensions. H3 and W3 (not shown in diagram) are the enclosure
dimensions without cover.
Wire Ranges
H1 H2 H3 W1 W2 W3
18.5 in. 22.5 in. 22 in. 10.5 in. 15.4 in. 14.4 in. 3.8 in
470mm 571.8mm 558.8mm 266.7 392mm 366mm 97.5mm
23.5 in. 26.4 in. N/A 8.3 in. 12.6 in. N/A 6.3 in.
597mm 671.7mm N/A 211mm 320.7mm N/A 159.6mm
Amps Conductor Lug Neutral Lug Ground Lug
50 1/0 - #14 2/0 - #14 2/0 - #14
100 2/0 - #14 2/0 - #14 2/0 - #14
Height Width
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
©2013 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0199020SBY-C Printed in U.S.A. 04/17/13
• Dual coil (100A) and single coil (50A) designs.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA 1 (indoor rated) enclosure is standard.
• 5 Year Limited Warranty.
Depth
H2
W1
50 Amp Switch
H1
H2
W1
W2
100 Amp Switch
H1