Genelec 6010A, 4020A, 4030A Operating Manual

Page 1
Genelec 6010A Active Loudspeaker
Operating Manual
6010A
Page 2
General description
The bi-amplified Genelec 6010A is an ex-
designed for home theaters and professional
multimedia applications. As an active loud-
speaker, it contains drivers, power ampli-
fiers, active crossover filters and protection
circuitry. The MDE™ (Minimum Diffraction
Enclosure™) loudspeaker enclosure is made
of die-cast aluminium and shaped to reduce
edge diffraction. Combined with the advanced
Directivity Control WaveguideTM (DCWTM), this
design provides excellent frequency balance
in difficult acoustic environments. If neces-
sary, the bass response of the 6010A’s can
be extended with a Genelec 5040A subwoof-
er.
Packing contents
Each 6010A is supplied with a wall bracket, a
mains cable, a 3.5 mm Jack to 2 x RCA sig-
nal cable, an RCA to RCA signal cable, this
operating manual and a quick setup guide.
After unpacking, place the loudspeaker in its
required listening position.
Mounting considerations
Align the loudspeakers correctly
Always place the loudspeakers so that their
acoustic axes converge at ear height at the
listening position (see Figures 1 and 2). Only
vertical placement of loudspeakers is pre-
ferred, as it minimises acoustical cancellation
problems around the crossover frequency.
Maintain symmetry
Check that the loudspeakers are placed
symmetrically and at an equal distance
fr om th e listening position. If possi -
ble, place the system so that the listen-
ing position is on the centerline of the
room and the loudspeakers are placed
at an equal distance from the centerline.
6010A Active Loudspeaker
Page 3
Figure 1: Location of the acoustic axis.
Figure 3: Control and connector layout on the rear panel of the 6010A.
Figure 2: Correct alignment of the
loudspeakers in a 5-channel system.
Minimise reflections
Acoustic reflections from objects close to
the loudspeakers like desks, cabinets, com-
puter monitors etc. can cause unwanted
colouration and blurring of the sound im-
age. These reflections can be minimised
by placing the loudspeaker clear of such
surfaces.
Minimum clearances
Sufficient cooling for the amplifier and func-
tioning of the reflex port must be ensured if
the loudspeaker is installed in a restricted
space such as a cabinet or integrated into
a wall structure. The surroundings of the
loudspeaker must always be open to the
listening room with a minimum clearance of
Page 4
2.5 centimeters (1”) behind, above and on
both sides of the loudspeaker. The space
adjacent to the amplifier must either be ven-
tilated or sufficiently large to dissipate heat
so that the ambient temperature does not
rise above 35 degrees Celsius (95°F)
Connections
Connect the loudspeaker to a mains connec-
tion with the supplied mains cable. Check
that the loudspeaker and the signal source
are powered off.
The 6010A has an unbalanced RCA
10 kOhm audio input connector. The signal
cables provided with the loudspeaker allow it
to be connected to a line level audio source
with either 3.5 mm Jack or RCA type au-
dio connectors. Suitable audio sources are
preamplifiers, computer sound cards, port-
able audio players, “PRE OUT” connectors
on a Home Theater receiver etc.
As an active loudspeaker, the 6010A
contains its own amplifiers, no separate
power amplifier is needed. Never connect
the 6010A to the loudspeaker outputs of a
power amplifier or an integrated amplifier or
receiver. Once the connections have been
made, the loudspeakers are ready to be
switched on.
Controls
The input sensitivity of the 6010A can be
matched to the output of the audio source by
adjusting the “LEVEL” trim on the rear panel
with a screwdriver.
The frequency response of the Genelec
6010A can be adjusted to match the acous-
tic environment by setting the tone control
switches on the rear panel. The controls are
“Bass Tilt” and “Desktop Control”. Table 1
shows some examples of typical settings in
various situations. Figure 4 shows the effect
of the controls on the anechoic response.
The factory setting for all tone controls is
“OFF” to give a flat anechoic response. Al-
ways start adjustment by setting all switches
to “OFF” position. Measure or listen system-
atically through the different combinations of
settings to find the best frequency balance.
Bass Tilt
The Bass Tilt control offers three attenu-
ation levels for the bass response of the
loudspeaker, usually necessary when the
loudspeakers are placed near a wall or other
room boundaries. The attenuation levels are
-2 dB (switch 1 “ON”), -4 dB (switch 2 “ON”)
and -6 dB (both switches “ON”).
Table 1: Suggested tone control settings for differing acoustical environments
Loudpeaker Mounting Position Desktop Bass Tilt
Flat anechoic response
OFF OFF
Free standing in a damped room
OFF OFF
Free standing in a reverberant room
OFF -2 dB
Near to a wall
OFF -6 dB
Near field on a reflective surface
ON (-4 dB @ 200 Hz) -2 dB
In a corner or a cabinet
OFF -6 dB
Page 5
Desktop Control
The desktop low frequency control (switch
3) attenuates the bass frequencies around
200 Hz by 4 dB. This feature is designed to
compensate for the boost often occurring in
this frequency range when there is a table
or similar horizontal surface between the lis-
tener and the loudspeaker.
Mounting options
The 6010A offers several mounting options:
The Iso-Pod™ (Isolation Positioner/Decou-
pler™) vibration insulating table stand allows
tilting the loudspeaker for correct alignment
of the acoustic axis. A rigid wall bracket pro-
vided with the 6010A allows suspending the
loudspeaker on a wall in two different an-
gles. On the rear of the loudspeaker is a 3/8”
UNC threaded hole compatible with stand-
ard microphone stands and a wide range
of Genelec accessories. On the rear there
are also three pairs of threaded holes com-
patible with Omnimount®, VESA and Sanus
brackets. For a full list of available options,
please consult Genelec’s accessories cata-
logue at www.genelec.com or contact your
Genelec dealer.
Maintenance
No user serviceable parts are to be found
within the amplifier unit. Any maintenance or
repair of the 6010A unit should only be un-
dertaken by qualified service personnel.
Safety considerations
Although the 6010A has been designed in
accordance with international safety stand-
ards, the following warnings and cautions
should be observed to ensure safe operation
and to maintain the loudspeaker under safe
operating conditions:
• Servicing and adjustment must only be
performed by qualified service personnel.
The loudspeaker must not be opened.
• Do not expose the loudspeaker to water
or moisture. Do not place any objects
filled with liquid, such as vases on the
loudspeaker or near it.
• This loudspeaker is capable of producing
sound pressure levels in excess of 85 dB,
which may cause permanent hearing
damage.
• Free flow of air behind the loudspeaker is
necessary to maintain sufficient cooling.
Do not obstruct airflow around the
loudspeaker.
• Note that the amplifier is not completely
disconnected from the AC mains service
unless the mains power cord is removed
from the amplifier or the mains outlet.
Guarantee
This product is guaranteed for a period of
two years against faults in materials or work-
manship. Refer to supplier for full sales and
guarantee terms.
EC Declaration of Conformity
This is to certify that the Genelec Active Loudspeaker 6010A conforms to the following standards:
Safety: EN 60065: 2002 + A1:2006 / IEC 60065:2001 7th Edition + A1: 2005 EMC: EN 55020 : 2002 + A1 : 2003 EN 55013: (2001)+ A1 : 2003 EN 61000-3-2 (2000) EN 61000-3-3 (1995)
The product herewith complies with the requirements of The Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC
Signed: Ilpo Mar tikainen Position: Chairman of the Board Date: 15-May-2008
Page 6
Figure 4. The curves above show the effect of the “Bass Tilt” and “Desktop” controls on the free field response of the 6010A.
Figure 5. The upper curve group shows the horizontal directivity characteristics of the 6010A measured at 1 m. The lower curve shows the system's power response.
Page 7
Bass amplifier output power with an 8 Ohm load: 12 W
Treble amplifier output power with an 8 Ohm load: 12 W
Long term output power is limited by driver unit protection circuitry.
Amplifier system distor tion at nominal output: THD + N < 0.08 %
Mains voltage: 100, 120, 220 or 230 V according to region
Voltage operating range: ±10 %
Power consumption: Idle 5 VA Full output 35 VA
Lower cut-off frequency, –3 dB: < 73 Hz
Upper cut-off frequency, –3 dB:
> 21 kHz
Free field frequency response of system: 74 Hz – 18 kHz (± 2.5 dB)
Maximum short term sine wave acoustic output on axis in half space, averaged from 100 Hz to 3 kHz: @ 1 m
> 93 dB SPL
@ 0.5 m
> 99 dB SPL
Maximum long term RMS acoustic output in same conditions with IEC weighted noise (limited by driver unit protection circuit): @ 1 m
> 91 dB SPL
Maximum peak acoustic output per pair in half space @ 1 m with music material: > 102 dB
Self generated noise level in free field @ 1 m on axis: < 5 dB (A-weighted)
Harmonic distortion at 85 dB SPL @ 1 m on axis: Frequency: 70…400 Hz < 3 % > 400 Hz < 0.5 %
Drivers: Bass 76 mm (3") cone Treble 19 mm (
3
/4") metal dome
Weight: 1.4 kg (3.1 lb)
Dimensions: Height 195 mm (711/16”) (including Iso-Pod™ table stand) Height
181 mm (71/8”) (without Iso-Pod™ table stand) Width
121 mm (43/4") Depth 114 mm (41/2”)
Signal input connector: RCA female, unbalanced 10 kOhm, pin +, sleeve -
Input level for 90 dB SPL output at 1 m:
-6 dBu at level control max
Level control range:
-12 dB relative to maximum output
Crossover frequency, Bass/Treble: 3.0 kHz
Desktop Control operating range: 0 to –4 dB @ 200 Hz
Bass Tilt control operating range in –2 dB steps: 0 to –6 dB @ 100 Hz
The ‘CAL’ position is with all tone controls set to ‘off’ and the input sensitivity control to maximum (fully clockwise).
AMPLIFIER SECTION
CROSSOVER SECTIONSYSTEM SPECIFICATIONS
Page 8
6010A Operating Manual
Genelec Document D0074R001a Nova 750-6010 Copyright Genelec Oy 5.2008. All data subject to change withou t prior notic e.
www.genelec.com
International enq uiries :
Genelec
Olvitie 5
FIN-74100, Iisalmi , Finland
Phone +358 17 8388 1
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please con tact:
Genelec Inc .
7 Tech Circ le
Natick, MA 0 1760, USA
Phone +1 50 8 652 0 900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In Sweden please contact:
Genelec Sverige
Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email info@genelec.com
In China pl ease co ntact:
Beijing Gen elec Aud io Co. Ltd .
Jianwai SOHO, Tower 12 , Room 3304
39 East 3rd Ring R oad, Chaoyang D istric t
Beijing 100 022, Ch ina
Phone +86 1 0 5869 7915
Fax +86 10 58 69 7914
Loading...