Quick-Start instructions for this product are contained in publication 05-6398A01.
Visit our website for downloadable copies of all documentation at www.gemds.com.
IMPORTANT
This manual describes the details, installation, configuration and operation of the MDS™ Master Station. It does not cover the description or configuration of features and settings common to the MDS Orbit family of products. For full information on configuring the parts of the system that are not directly related to SD/LN networking or the MDS Master Station, please reference the MDS Orbit MCR Technical Manual (p/n: 05-6632A01). The MDS Master Station manual is designed to be used in parallel with the MCR Technical Manual, and as such does NOT cover information already described in that manual.
MDS 05-6399A01, Rev. F MDS™ Master Station 1
TABLE OF CONTENTS
1.0 INTRODUCTION ..................................................................................................... 9
1.1 Organization of Manual............................................................................................... 9
Related Publications .............................................................................................. 10
2.0 KEY PRODUCT FEATURES................................................................................ 11
2.1 Accessories and Spare Items ................................................................................... 13
2.2 FCC Emission Designators: How to Find Them ...................................................... 15
2.3 Front Panel ................................................................................................................ 15
2.4 Rear Antenna Connections ...................................................................................... 16
3.0 INSTALLATION PLANNING ................................................................................ 17
3.1 Applications ............................................................................................................... 17
Repeater and Polling Remote Operation (MPRS Only) ....................................... 18
Simplex and Switched Carrier Operation ............................................................. 18
3.2 Network Management............................................................................................... 18
MPRS Network-Wide Diagnostics ........................................................................ 18
MPRS Network Management Using PulseNET ................................................... 18
3.3 Redundant versus Non-redundant Operation .......................................................... 19
3.4 Antennas and Feedlines ........................................................................................... 19
Antennas ................................................................................................................ 19
Feedlines ............................................................................................................... 19
3.5 Grounding Considerations ........................................................................................ 20
3.6 Data Interface Connections ...................................................................................... 21
Ethernet Data Interface (RJ-45) ............................................................................ 21
Serial Data Interfaces ............................................................................................ 21
MPRS Serial Data Connection .............................................................................. 21
Mini USB ................................................................................................................ 22
Alarm Output and 4-Wire Audio ............................................................................ 22
4.0 INSTALLATION PROCEDURES ......................................................................... 23
4.1 Unpacking and Inspection ........................................................................................ 23
4.2 Installation Steps....................................................................................................... 23
Initial Startup & Operation ..................................................................................... 26
Module LED Indicators .......................................................................................... 26
Normal Indications ................................................................................................. 27
Maximizing RSSI ................................................................................................... 27
5.0 DEVICE MANAGEMENT ...................................................................................... 28
5.1 Pre-Configured Settings ........................................................................................... 28
5.2 One-Time “Recovery” Passwords ............................................................................ 28
One-Time Passwords: How They Work ............................................................... 28
Creating a One-Time Password ............................................................................ 29
Logging in With a One-Time Password ................................................................ 29
Deleting a One-Time Password ............................................................................ 29
5.3 Configuration via Command Line (CLI) .................................................................... 30
Tab Completion Feature ....................................................................................... 30
2 MDS™ Master Station MDS 05-6399A01, Rev. F
CLI Quick Reference Table ................................................................................... 30
5.4 Interface Naming....................................................................................................... 32
5.5 Configuration via the Device Manager ..................................................................... 32
General Configuration ........................................................................................... 33
5.6 Interface Configuration ............................................................................................. 34
Understanding ....................................................................................................... 34
Configuring ............................................................................................................ 34
5.7 LAN............................................................................................................................ 38
Understanding ....................................................................................................... 38
Configuring ............................................................................................................ 38
5.8 Bridging ..................................................................................................................... 40
Understanding ....................................................................................................... 40
Configuring ............................................................................................................ 41
5.9 SDMS Interface ......................................................................................................... 41
Understanding ....................................................................................................... 41
Configuration ......................................................................................................... 43
General Settings .................................................................................................... 44
Dlink ....................................................................................................................... 48
MAC Settings ......................................................................................................... 49
IP Payload ............................................................................................................. 51
Advanced Configuration ........................................................................................ 57
Audio ...................................................................................................................... 60
Actions ................................................................................................................... 61
Remote SD Reprogramming ................................................................................. 65
Monitoring .............................................................................................................. 69
Performance .......................................................................................................... 70
5.10 SD-x/0/0 Interfaces ................................................................................................... 71
General .................................................................................................................. 71
Statistics................................................................................................................. 71
5.11 LNMS interface ......................................................................................................... 74
Understanding ....................................................................................................... 74
Advanced Configuration ........................................................................................ 80
Monitoring .............................................................................................................. 81
CLI Configuration Examples ................................................................................. 86
5.12 LN-x/0/0 interfaces .................................................................................................... 93
6.0 MASTER STATION MODULES ........................................................................... 94
6.1 AC Power Supply Module ......................................................................................... 95
6.2 DC Power Supply Module ........................................................................................ 96
6.3 Platform Manager Module ........................................................................................ 97
Platform Manager LED Indicators ......................................................................... 97
Ethernet Interfaces ................................................................................................ 97
COM1 Interface ..................................................................................................... 98
COM2 Interface ..................................................................................................... 99
Mini USB Interface............................................................................................... 101
6.4 SD Radio Modules .................................................................................................. 102
SD Master Radio Module LED Indicators ........................................................... 102
SD Master Radio Module RF Interface ............................................................... 102
MDS 05-6399A01, Rev. F MDS™ Master Station 3
Technical Specifications ...................................................................................... 103
6.5 LN Radio Modules .................................................................................................. 105
LN Master Radio Module LED Indicators ........................................................... 105
Technical Specifications ...................................................................................... 106
6.6 Alarm and Alarm/Relay Modules ............................................................................ 109
Alarm Module LEDs ............................................................................................ 110
Alarm/Audio Interface .......................................................................................... 110
Alarm/Relay Toggle Switch (6847 Only) ............................................................. 111
Alarm/Relay RF Connections (6847 Only) ......................................................... 111
6.7 Duplexer Tray.......................................................................................................... 112
7.0 SPECIAL CONFIGURATIONS ........................................................................... 113
7.1 Migrating “A” Modem Networks .............................................................................. 113
Mitigation strategy for mixed SDx/x710 repeater networks using the “A” modem ..... 113
User Configuration 1: Non-CKEY Repeater Network Case ............................... 113
User Configuration 2: CKEY Repeater Network Case ....................................... 114
8.0 TROUBLESHOOTING ........................................................................................ 115
8.1 Interpreting Module LEDs ....................................................................................... 115
Normal Operation ................................................................................................ 115
Exception and Alarm States ................................................................................ 116
8.2 Redundant Units ..................................................................................................... 116
8.3 Technical Assistance .............................................................................................. 116
8.4 Replacing Modules ................................................................................................. 116
Power Supply Modules........................................................................................ 117
Peripheral Modules – including Platform Manager, Radio, Alarm, and Alarm
Relay Modules. .................................................................................................... 117
Hot Swap Redundant Modules ........................................................................... 118
Internal Duplexer Tray ......................................................................................... 119
400 MHz Notch-Type Duplexers ......................................................................... 119
Bandpass-Type Duplexers .................................................................................. 119
8.5 Testing and Removing an Internal Duplexer ......................................................... 120
Testing ................................................................................................................. 120
Removing the Internal Duplexer ......................................................................... 120
9.0 TECHNICAL REFERENCE DATA ..................................................................... 124
9.1 RF Propagation Planning ....................................................................................... 124
Fresnel Zone Clearance ...................................................................................... 124
Formulas for System Planning ............................................................................ 125
9.2 dBm-Volts-Watts Conversion Chart ....................................................................... 127
10.0 GLOSSARY OF TERMS & ABBREVIATIONS ................................................. 128
4 MDS™ Master Station MDS 05-6399A01, Rev. F
Copyright Notice
This Technical Manual and all software described herein are protected by copyright: 2015 GE MDS. All rights reserved. GE MDS reserves its right to correct any errors and omissions in this publication.
Safety words and definitions
The following symbols used in this document indicate the following conditions:
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
Indicates practices not related to personal injury.
Indicates general information and practices, including operational information and practices that are not related to personal injury.
Installation & Servicing Precautions
The unit is provided for professional installation only, and utilizes a
specialized antenna connector to restrict the types of antenna connections that may be made. The integrator of this device is responsible for compliance with all applicable limits on radiated RF power, and the RF power output may need to be adjusted to maintain compliance, depending on the gain of the antenna system. All power supply main connections and disconnections must be made by a qualified electrical installer. When servicing energized equipment, be sure to wear appropriate Personal Protective Equipment (PPE). During internal service, situations could arise where objects accidentally contact or short circuit components and the appropriate PPE would alleviate or decrease the severity of potential injury. When servicing radios, all workplace regulations and other applicable standards for live electrical work should be followed to ensure personal safety.
Operational Safety Notices
The radio equipment described in this guide uses radio frequency transmitters. Although the power level is low, the concentrated energy from a directional antenna may pose a health hazard. Do not allow people to come in close proximity to the front of the antenna when the transmitter is operating. More information on RF exposure can be found online at the following website:
www.fcc.gov/oet/info/documents/bulletins
This manual is intended to guide a professional installer to install, operate, and perform basic system maintenance on the described radio.
MDS 05-6399A01, Rev. F MDS™ Master Station 5
The RF safety distance is calculated based on each product type’s highest output power
configuration with no duplexer, redundant switching, or cable losses.
Table 1-1 Antenna Gain vs. Minimum RF Safety Distance
Radio Module Equipped Antenna Gain
0–5 dBi
5–10 dBi
10–16.5 dBi
SDM4 – FCC
1.09 meters
1.95 meters
4.11 meters
SDM4 – IC
1.43 meters
2.54 meters
5.37 meters
SDM9 – FCC
0.99 meters
1.76 meters
3.73 meters
SDM9 – IC
1.29 meters
2.30 meters
4.87 meters
LN4
1.43 meters
2.54 meters
5.07 meters
LN9
1.08 meters
1.92 meters
3.82 meters
(other models):
Consult factory prior to operation.
Not all frequency models available. Consult factory for available models. Antennas with gain greater than 16dBi have not been authorized for use with the EUT; and (b) installation of the EUT into portable applications with respect to RF compliance will require SAR testing and Regulatory approval.
CSA Notice
Units (Both AC and DC supply versions) are permanently connected to
Protective Earth, via ground stud on the unit enclosure back, where the final installation is subject to acceptance of CSA International or the local inspection authority having jurisdiction.
Conditions of Acceptability:
1. The equipment shall be installed indoors in a restricted access
location.
2. Installation of the equipment and its modules shall be conducted by
trained personnel in accordance with the electrical code.
3. This equipment is movable, Class I (earthed), pluggable Type A,
using detachable power cords, intended for use on TN or TT power system for the AC power option.
4. The DC power option shall be connected to an approved power
source with adequate protection, isolated from the mains by reinforced insulation.
5. This product was certified for use on a 20A branch circuit for the AC
power option.
6 MDS™ Master Station MDS 05-6399A01, Rev. F
6. The AC socket outlet shall be installed near the equipment and shall
be easily accessible.
7. The power supply cord must be disconnected from the appliance inlet
before removing any power supply from the chassis.
8. CAUTION: THIS UNIT HAS MORE THAN ONE POWER SUPPLY
CORD. DISCONNECT THE TWO POWER SUPPLY CORDS BEFORE SERVICING TO AVOID ELECTRIC SHOCK
9. The equipment chassis shall be permanently grounded though a size
six screw and a star toothed washer.
10. The interior of the equipment is not for operator access.
FCC Part 15 Notice
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment
FCC IDs of Available Transmitters
As of the printing date, the following identifiers are assigned to the modules listed below. For the latest, official listings of all agency approvals, please contact your factory representative.
Radio Desc.
FCC ID
IC ID
WIFI Module
M4Y-ZCN722MV1
3195A-ZCN722MV1
LN 400Mhz Module
E5MDS-LN400
101D-LN400
LN 700Mhz Module
E5MDS-LN700
n/a
LN 900Mhz Module
E5MDS-LN900
101D-LN900
SD 400Mhz Module
E5MDS-SDM4
101D-SDM4
SD 900Mhz Module
E5MDS-SDM9
101D-SDM9
Canada, IC ERP Limits
IC SRSP-501, 6.3.2. Limits the ERP to 125W for fixed point-to-point operation. For IC use, the antenna gain and Transmit power must be set to meet the ERP limit of 125W. This can be accomplished by using the appropriate at antenna gain in combination with the RF power settings
MDS 05-6399A01, Rev. F MDS™ Master Station 7
Environmental Information
The equipment that you purchased has required the extraction and use of natural resources for its production. Improper disposal may contaminate the environment and present a health risk due to hazardous substances contained within. To avoid dissemination of these substances into our environment, and to diminish the demand on natural resources, we encourage you to use the appropriate recycling systems for disposal. These systems will reuse or recycle most of the materials found in this equipment in a sound way. Please contact GE MDS or your supplier for more information on the proper disposal of this equipment.
ISO 9001 Registration
GE MDS adheres to this internationally-accepted quality system standard.
Quality Policy Statement
We, the employees of GE MDS, are committed to achieving total customer satisfaction in everything we do.
Total Customer Satisfaction in:
Conception, design, manufacture, and marketing of our products.
Services and support we provide to our internal and external customers.
Total Customer Satisfaction Achieved Through:
Processes that are well documented and minimize variations.
Partnering with suppliers who are committed to providing quality and service.
Measuring our performance against customer expectations and industry leaders.
Commitment to continuous improvement and employee involvement.
Revision Notice
While every reasonable effort has been made to ensure the accuracy of this manual, product improvements may result in minor differences between the manual and the product shipped to you. If you have additional questions or need an exact specification for a product, please contact our Customer Service Team using the information at the back of this guide. In addition, manual updates can often be found on our Web site at www.gemds.com.
ESD Notice
To prevent malfunction or damage to this radio, which may be caused by Electrostatic Discharge
(ESD), the radio should be properly grounded by connection to the ground stud on the rear panel. In addition, the installer or operator should follow proper ESD precautions, such as touching a grounded bare metal object to dissipate body charge, prior to connecting and
disconnecting cables on the front or rear panels.
Open Source License Declaration
Orbit MCR products include Open Source Software. Usage is governed by the corresponding licenses which are listed on the GE MDS Industrial Wireless website, under Orbit MCR Software/Firmware Downloads, Support Items and download license-declaration.txt. Upon request, in accordance with certain software license terms, GE will make available a copy
of Open Source code contained in this product. This code is provided to you on an “as is” basis,
8 MDS™ Master Station MDS 05-6399A01, Rev. F
and GE makes no representations or warranties for the use of this code by you independent of any GE provided software or services. For more information, contact
gemds.techsupport@ge.com.
MDS 05-6399A01, Rev. F MDS™ Master Station 9

1.0 INTRODUCTION

The MDS Master Station is an advanced, flexible platform designed for the demanding requirements of today’s industrial wireless networks. It represents the latest development in a
line of MDS products that set the standards for wireless performance today. The Master Station builds on this legacy with several innovative features, including a single compact chassis (2 RU), 100% duty cycle operation (no cooling fans required), front panel access to all modules, and drop-in compatibility with earlier MDS x790/x710 radio systems. As the central station in a wireless network, the Master Station provides uncompromised performance and reliability in mission-critical applications. It offers redundant protection of key modules, automatic switchover in the event of a fault, and an external battery backup option for continued operation through temporary power losses. The Master Station mounts conveniently in a 19-inch rack cabinet, or may be used in shelf/tabletop configurations.
Figure 1-1. MDS Master Station
The Master Station can be configured for a variety of service applications, including Point-to­Multipoint SCADA, Point-to-Point links, broadband, and Cellular connectivity, depending on the modules installed and active in the chassis. In FCC part 90 SCADA service, the radio can function as a Master, Repeater, or Remote and is capable of full duplex operation. Internal duplexer options are available, configured for use with or without an external notch filter. Provisions for connection to an external duplexer are also provided. The Master Station is fully compatible with MDS PulseNET management software, which provides local or remote diagnosis and health reporting.

1.1 Organization of Manual

This manual is intended for use by systems engineers, network administrators, and others responsible for the planning, installation, commissioning, use, and troubleshooting of the wireless system. The manual begins with an overall description of product features, and is followed by the steps required to install the unit and place it into normal operation. Following the installation procedures, sections are devoted to particular modules that may be installed in the chassis, including configuration settings for each of these units. Additionally, troubleshooting tips for resolving system difficulties are offered, as well as a technical reference section with data on wiring, specifications, and spare parts that may be ordered for the unit. When installation and setup of the radio is complete, it is recommended that this guide be kept available for future reference at the installation site. Updated manuals, firmware, and other support documents may be obtained at any time from our website: www.gemds.com.
10 MDS™ Master Station MDS 05-6399A01, Rev. F

Related Publications

In addition to this manual, a companion Setup Guide is available for the MDS Master Station, Part No. 05-6398A01. The Setup Guide is focused on the essential steps for installation and startup of the unit, and is designed to be used with this Technical Manual.
The MDS™ Master Station Setup Guide, Part No. 05-6398A01 contains basic installation and startup instructions for the product.
All GE MDS user manuals and updates are available online at www.gemds.com.
The MDS Master Station is built on the Orbit platform. For reference information on advanced networking features available on the local LAN Interface, refer to the MDS Orbit MCR Technical Manual (05-6632A01). Note that not all features are supported by the Master Station or the SD Radio Module. Wireless networking capabilities are limited by the narrowband channel and the capabilities of the remote radio.
MDS 05-6399A01, Rev. F MDS™ Master Station 11

2.0 KEY PRODUCT FEATURES

As a licensed, long range IP/Ethernet and serial communications device, the Master Station exceeds industry standards for reliability and performance in wireless networks. Listed below are several key features and benefits of the product, and these are available with the appropriate modules installed and configured in the chassis.
Drop-in replacement for earlier MDS x790 Master Stations, including support for all
modem types
Backward compatibility with all legacy MDS x710 Series remote transceivers (A and B
modems)
Compatible with next generation MDS narrowband wireless LN radios, with enhanced
throughput and security. (When equipped with LN radio cards)
May be operated as a Master Station, repeater, or remote radio
Supports use of MDS™ PulseNET Network Management Software
Software-configurable via a built-in web-based device manager—no manual adjustments
required
Firmware-upgradeable for future improvements and functionality enhancements
Available encryption of payload data (AES 128-bit), for networks using all-SD radios
Dual serial functionality (RS-232 and RS-485)
Licensed 10-watt radio design ensures minimum 5-watts at the duplexer output, and
maximizes communications range with low interference risk from other users
RF power adjustable; 1-10 watts at output of radio card (before relay & duplexer)
Unit is configurable via software, locally or remote
Media Access Control (MAC) to prevent data collisions when two or more radios attempt
to use the radio channel at the same time
Supports a wide variety of modem speeds and bandwidths for regulatory compliance in
virtually all regions of the world (future availability)
Some features may not be available on all units, depending on the options purchased and regulatory constraints for the region in which the radio will operate.
Figure 2-1 MPRL Compatible Remotes
12 MDS™ Master Station MDS 05-6399A01, Rev. F
When equipped with LN radio cards, the Master Station works with Orbit MCR LN (left) and
Orbit ECR LN (right.
Figure 2-2 MPRS Compatible Remotes
When equipped with SD radio cards, the Master Station works with legacy MDS x710 (left), and
newer MDS SD Transceivers.
MDS 05-6399A01, Rev. F MDS™ Master Station 13

2.1 Accessories and Spare Items

The following table lists common accessories and spare items for use with the Master Station. GE MDS also offers an Accessories Selection Guide listing an array of additional items available for use with the product. Contact your factory representative or visit www.gemds.com to obtain a copy of the guide.
Table 2-1. Accessories and Spares
Item
Description
Part Number
Three-conductor DC power plug
Mates with power connector on the front of the unit’s DC power supply
module. Screw terminals are provided for wires, and threaded locking screws to prevent accidental disconnect.
73-1194A22
Setup Guide (for installation & basic startup)
Brief document describing the installation and setup of the unit. One copy normally supplied with each unit. Additional PDF copies available (no charge) from www.gemds.com.
05-6398A01 COM Port Adapter
Converts the unit’s RJ-45 serial jack to a DB-9F type.
73-2434A25
Mini USB 2.0 Cable, 3 ft./0.91 meter length
USB Type A (M) to mini-USB Type B (M) cable to provide console access through the radio’s mini USB connector.
97-6694A05
Lightning Protectors
Polyphaser Surge Protector, IS-50NX-C2, DC blocked, 125 MHz to 1000 MHz, N-female connectors, surface (flange) mount Polyphaser Surge Protector, IS-B50LN-C2, DC blocked, 125 MHz to 1000 MHz, N-female connectors, bulkhead mount
97-1680A01 97-1680A05
Cavity Filter Kit
Removes or attenuates interfering 900 MHz signals from the receiver input. Might be necessary in areas with high powered stations nearby, such as paging transmitters. Requires tuning to a particular frequency. Available for use with an internal or external duplexer.
03-3621Axx Alarm & Audio Cable
Cable connects to 6847/6848 Alarm/Relay Modules to provide access to four wire audio, push to talk, analog RSSI, and Major/Minor alarm dry contacts
03-6940A01
External Battery Kit
2U rack mounted UPS battery backup. Connects to 03-6755A02 AC power module. UPS, 120V, 1.5kVA, 900W, 2U – UL/CSA for North America UPS, 230V, 1.5kVA, 900W, 2U – CE Marked for Europe
97-4444A01 97-4444A02
100-220 AC Power Supply Module
100-220 VAC, 50/60 Hz. 120W Max AC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDS Master Station.
03-6755A03
+/- 12-36 VDC Power Supply Module
+/- 12-36 VDC. 10 A Max. DC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDS™ Master Station.
03-6843A01
+/- 36-75 VDC Power Supply Module
+/- 36-75 VDC. 3.5 A Max DC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDS™ Master Station.
03-6844A01
+/- 75-140 VDC Power Supply Module
+/- 75-140 VDC. 2 A Max DC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDS™ Master Station.
03-6845A01 Platform Manager Module
Provides management and data interface functions.
03-6834A01A
SDM9 Module
SDM9 C-band full duplex radio: 928-960MHz FCC Part 24, 101, 90, IC SDM9 K-band full duplex radio: TX 928-960MHz / RX 880-915MHz FCC
Part 24, 101, 90
03-6846A01-9C 03-6846A01-9K
14 MDS™ Master Station MDS 05-6399A01, Rev. F
Table 2-1. Accessories and Spares
Item
Description
Part Number
SDM4 Module
SDM4 B-band full duplex radio: 400-450MHz FCC Part 22, 90, IC, CE SDM4 C-band full duplex radio: 450-512MHz FCC Part 90, IC, CE
03-6846A01-4B 03-6846A01-4C
LN4 Module
LN400 E-band QAM radio: 406.1-470MHz FCC Part 90, CE LN400 A-band QAM radio: 330-406MHz CE
03-6846-L4E 03-6846-L4A
LN7 Module
LN700 A-band QAM radio: 757-758MHz, 787-788MHz FCC Part 27
03-6846-L7A
LN9 Module
LN900 C-band QAM radio: 896-960MHz FCC Part 101, 90, IC
03-6846-L9C
Redundant Alarm/Relay Module
Active radio relay and alarm/audio interface.
03-6847A01
Non-Redundant Alarm Module
Non-redundantalarm and audio interface.
03-6848A01
900MHz Duplexers (TX HIGH)
Spare duplexer in tray wired for MDS Master Station. 9 MHz RX 932.0-932.5, TX 941.0-941.5), COMBINED OUT
24 MHz RX 928.0-929.0, TX 952.0-953.0), COMBINED OUT 31 MHz RX 928.0-929.0, TX 959.0-960.0), COMBINED OUT 9 MHz RX 932.0-932.5, TX 941.0-941.5),3 port out for filter 24 MHz RX 928.0-929.0, TX 952.0-953.0),3 port out for filter 31 MHz RX 928.0-929.0, TX 959.0-960.0),3 port out for filter 39 MHz RX 896.0-898.0, TX 935.0-937.0, COMBINED OUT 39 MHz RX 896.0-898.0, TX 935.0-937.0, 3 port out for filter
03-6837D9B1 03-6837D9C1 03-6837D9D1 03-6837D9B3 03-6837D9C3 03-6837D9D3 03-6837D9E1 03-6837D9E3
900MHz Duplexers (TX LOW)
Spare duplexer in tray wired for MDS Master Station. 9 MHz TX 932.0-932.5, RX 941.0-941.5), COMBINED OUT
24 MHz TX 928.0-929.0, RX 952.0-953.0), COMBINED OUT 31 MHz TX 928.0-929.0, RX 959.0-960.0), COMBINED OUT 9 MHz TX 932.0-932.5, RX 941.0-941.5),3 port out for filter 24 MHz TX 928.0-929.0, RX 952.0-953.0),3 port out for filter 31 MHz TX 928.0-929.0, RX 959.0-960.0),3 port out for filter 39 MHz TX 896.0-898.0, RX 935.0-937.0, COMBINED OUT 39 MHz TX 896.0-898.0, RX 935.0-937.0, 3 port out for filter
03-6837D9Q1 03-6837D9R1 03-6837D9S1 03-6837D9Q3 03-6837D9R3 03-6837D9S3 03-6837D9T1 03-6837D9T3
350-512MHz Duplexers
Spare duplexer in tray wired for MDS Master Station. 5-10 MHz Split (350 - 512MHz), TX HIGH,COMBINED OUT
5-10 MHz Split (350 - 512MHz), TX HIGH, 3 port out for filter 5-10 MHz Split (350 - 512MHz), TX LOW,COMBINED OUT 5-10 MHz Split (350 - 512MHz), TX LOW, 3 port out for filter
03-6837D411 03-6837D413 03-6837D421 03-6837D423
700MHz Duplexers
Spare duplexer in tray wired for MDS Master Station. RX 757-758MHz, TX 787-788MHz,COMBINED OUT
RX 757-758MHz, TX 787-788MHz, 3 port out for filter TX 757-758MHz, TX 787-788MHz,COMBINED OUT TX 757-758MHz, RX 787-788MHz, 3 port out for filter
03-6837D711 03-6837D713 03-6837D721 03-6837D723
Front Cable Replacements
Non-Redundant Radio to Duplexer: SMA MALE TO SMB FEMALE Redundant Relay to Duplexer: SMA MALE TO SMB FEMALE Redundant Radio to Relay: SMB FEMALE TO SMB FEMALE
03-4528A07 03-4528A07 03-4528A08
MDS 05-6399A01, Rev. F MDS™ Master Station 15

2.2 FCC Emission Designators: How to Find Them

An FCC emission designator is a seven-character string that represents the bandwidth, modulation, and other characteristics of a transmitted radio signal. This information is required when applying for an FCC license. The designator assigned to your equipment depends on the particular sub-model of the product line you are licensing. In some cases, multiple designators are used to cover product variants such as base stations, remotes, indoor/outdoor units, frequency
band, etc. An updated and official list of emission designators is maintained on the FCC’s
website at the following link: https://apps.fcc.gov/oetcf/eas/reports/GenericSearch.cfm Once the site has been reached, proceed as follows to determine your designator:
1. At the top of form in the box labeled Grantee Code: enter E5M. This is the code for GE MDS
products.
2. At the bottom of the form in the box labeled Show x Records at a Time, enter a sufficiently large
number (i.e., 300) to display all GE MDS records on file. Press Enter.
3. Once the list appears, it can be searched to locate the particular model you are seeking
information on. To the left of each entry, there is a document icon. Click the icon to display the equipment authorization report.
4. Scroll down to the section labeled Equipment Specifications to locate the appropriate emission
designator. If additional assistance is required, contact GE MDS using the information given at the end of this manual.

2.3 Front Panel

All access to Master Station modules is made from the front of the unit after removing the protective cover. To remove the cover, simply grasp the sides and pull out with a slight rocking motion. Tether strips on the ends of the cover are available to keep it linked to the chassis when it has been removed from its installed position. The tethers allow the cover to rest just below the front panel during service work.
Figure 2-3. MDS Master Station, Front Panel Connections & Indicators
(Representative arrangement; Module types vary based on product configuration)
Master Station modules are factory installed and cabled. All modules are installed on slide-in assemblies and secured to the chassis with knurled fasteners. The illustration above shows the modules installed in a redundant configuration. For a non-redundant configuration, blank plates are used in place of the redundant power supply and radio modules, and a non-redundant version
16 MDS™ Master Station MDS 05-6399A01, Rev. F
of the Alarm/Relay module will be installed. The table that follows lists the module types available.
Table 2-2. Module Descriptions
Module Name
ID
Function
Power Supply 1 Power Supply 2
6843: (+/- 12-36 VDC) 6844: (+/- 36-75 VDC) 6845: (+/- 75-140 VDC) 6755: (110/220 VAC)
Provides operating power based on a variety of AC and DC input options. Up to two power supply modules may be installed in the chassis (AC or DC; any combination. In a redundant configuration, both power supplies work in tandem and are independent of which radio is currently active.
Platform Manager
6834
Provides management and data interface functions.
Radio A Radio B
6846 6846
Single or redundant SD or LN Master radios.
Alarm/Relay Module Alarm Module
6847 6848
RedundantActive radio RF relay and alarm/audio interface.
Non-redundantAlarm and audio interface.
Duplexer
6837
Internal RF duplexer (if equipped). Allows simultaneous transmission and reception of signals on separate TX/RX frequencies, using a single antenna.

2.4 Rear Antenna Connections

Figure 2-4. MDS Master Station, Rear Panel
Showing Antenna Connection & Heatsink
(Other configurations possible for external items such as duplexer or cavity filter)
MDS 05-6399A01, Rev. F MDS™ Master Station 17

3.0 INSTALLATION PLANNING

This section covers pre-installation factors that should be considered when installing the Master Station. Careful planning will help achieve optimal performance from the radio. After reviewing this section, refer to the step-by-step installation procedures beginning on Page 23. The specific details at an installation site may vary, but there are three main requirements for installing the unit in all cases:
Adequate and stable primary power
An efficient and properly installed antenna system
Correct interface connections between the Master Station and any connected equipment.
Figure 3-1 shows a common arrangement of the MPRS Master Station as used in a multiple address radio network. The system shows both SD and legacy x710 remote transceivers in use. Depending on order options, the Master Station can communicate with remotes employing Ethernet signaling, serial signaling, or a mix of both.
Figure 3-1 Application Example

3.1 Applications

The Master Station is designed for point-to-multipoint data transmission in utility SCADA communications, transactional systems, and telecommunications systems. The wireless network
18 MDS™ Master Station MDS 05-6399A01, Rev. F
provides communications between a central host computer and remote terminal units (RTUs) or other data collection devices. In such an arrangement, the operation of the radio system is transparent to the computer equipment.

Repeater and Polling Remote Operation (MPRS Only)

In a system using FCC Part 90 repeater and polling remote, the polling remote radio operates in half-duplex mode and the repeater operates in half-duplex or full-duplex mode. The SD Master Station can be used as a polling remote, or as a repeater. Refer to Page 44 for details on configuring the radio for repeater operation.

Simplex and Switched Carrier Operation

System-wide simplex operation is achieved by switching the Master Station carrier on to transmit, and then off to receive. The same frequency is used for both transmit and receive. In MPRS Master Stations, switched carrier, half-duplex mode works in the same way, except different frequencies are used for transmit and receive. Refer to Page 57 for details on configuring the radio for simplex operation for SD radios.

3.2 Network Management

MPRS Network-Wide Diagnostics

When operating with SD radio interfaces (MPRS), the Master Station offers network-wide diagnostics capability, sometimes referred to as DLINK Diagnostics. Network-wide diagnostics communications is a packetized diagnostic capability that provides the following advantages:
You can gather diagnostic data over a large radio network without disrupting the system
communications flow.
When required, you can increase diagnostics communications speed by actively collecting
diagnostic data.
You can access diagnostic data for each radio in the network from any radio diagnostics
port in the network.
You can broadcast certain messages to all radios in the system simultaneously.
You can use the Master Station to poll remote radios in its radio system for diagnostic data. For more information on the implementation of network-wide diagnostics, refer to the GE MDS Network-wide Diagnostics Handbook (P/N 05-3467A01).

MPRS Network Management Using PulseNET

PulseNET uses the SNMP, Netconf, and DLINK protocol to monitor the SD Master Station (MPRS) and downstream devices. The Master Station can be connected locally using either COM1 or COM2 serial or through Ethernet using TCP. Refer to the section Dlink” on Page 48 for more information about configuring DLINK on the Master Station. PulseNET remotely discovers and monitors Master Stations and other SD or x710 radios on the network using DLINK and other Orbit radios with SNMP and Netconf. The locally connected radio may be a Master, Repeater, Polling Remote, or Remote. This locally connected radio must be configured as the DLINK “root” radio to be discovered with DLINK. Downstream radios should be configured as “node”. PulseNET uses passive polling to discover the “root” radio and
MDS 05-6399A01, Rev. F MDS™ Master Station 19
all of the “node” radios downstream. Passive polling allows monitoring without interrupting
payload data transmission. In order for PulseNET to discover SD Master Stations in the network, DLINK must be enabled and properly configured. Refer to the section Dlink” on Page 48 for information on how to configure DLINK.

3.3 Redundant versus Non-redundant Operation

A redundant configuration means that the Master Station has two complete transceiver boards and power supplies installed in the enclosure. In the event of a failure in the primary equipment, the controlling logic switches to the stand-by unit. The stand-by transceiver board is constantly operating and its operational readiness is monitored. However, the power amplifier in the stand­by board is not operating when it is in stand-by mode. In a non-redundant configuration, there is only one transceiver board installed in the enclosure, and back-up transceiver board operation is not possible. Transceiver boards may be moved from one Master Station to another; however an additional transceiver board cannot be added to a non-redundant Master Station. Redundant or non­redundant operation is automatically detected by the platform manager, and the active transceiver is automatically selected. Installing or replacing a transceiver board causes the board to communicate briefly with the Platform Manager to establish which transceiver board will operate as the active board and which operates as the stand-by. For more information, refer to section 8.4 Replacing Modules on Page 116. When redundant power supplies are present, both supplies are actively operating; meaning there is no concept of an active vs stand-by power supply. If the system detects a loss of power on one of the power supplies, an alarm will be generated until power is restored.

3.4 Antennas and Feedlines

Antennas

The Master Station may be used with a number of different antennas. The exact style and gain factor depend on the physical size and layout of your system. Antennas of this type are available from several manufacturers, including GE MDS. Contact your factory representative for details. Connection is made to the station via N coaxial connectors at the rear panel.

Feedlines

The selection of an antenna feedline is very important. Poor quality cable should be avoided, as it will result in power losses that may reduce the range and reliability of the radio system. The tables that follow show the approximate losses that will occur when using various lengths and types of coaxial cable in the 400 and 900 MHz bands, respectively. Regardless of the type used, the cable should be kept as short as possible to minimize signal loss.
20 MDS™ Master Station MDS 05-6399A01, Rev. F
Table 3-1. Signal Loss in Coaxial Cables (at 900 MHz)
Cable Type
10 Feet
(3 Meters)
50 Feet
(15 Meters)
100 Feet
(30.5
Meters)
200 Feet
(61 Meters)
RG-8A/U
0.85 dB
4.27 dB
8.54 dB
17.08 dB
1/2 inch HELIAX
0.23 dB
1.15 dB
2.29 dB
4.58 dB
7/8 inch HELIAX
0.13 dB
0.64 dB
1.28 dB
2.56 dB
1-1/4 inch HELIAX
0.10 dB
0.48 dB
0.95 dB
1.90 dB
1-5/8 inch HELIAX
0.08 dB
0.40 dB
0.80 dB
1.60 dB
Table 3-2. Signal Loss in Coaxial Cables (at 400 MHz)
Cable Type
10 Feet (3 Meters)
50 Feet (15 Meters)
100 Feet (30.5 Meters)
200 Feet (61 Meters)
RG-8A/U
0.51 dB
2.53 dB
5.07 dB
10.14 dB
1/2 inch HELIAX
0.12 dB
0.76 dB
1.51 dB
3.02 dB
7/8 inch HELIAX
0.08 dB
0.42 dB
0.83 dB
1.66 dB
1-1/4 inch HELIAX
0.06 dB
0.31 dB
0.62 dB
1.24 dB
1-5/8 inch HELIAX
0.05 dB
0.26 dB
0.52 dB
1.04 dB

3.5 Grounding Considerations

To minimize the chance of damage to the radio and connected equipment, a safety ground (NEC Class 2 compliant) is recommended which bonds the Master Station, antenna system, and connected data equipment to a single-point ground, keeping all ground leads as short as possible. The Master Station should be grounded using the #6-32 screw and star washer provided for this purpose on the rear panel. The use of a lightning protector is also recommended where the antenna cable enters the equipment building; bond the protector to the tower/mast ground, if applicable. All grounds and cabling must comply with applicable codes and regulations.
Figure 3-2. Rear Panel Grounding Screw
MDS 05-6399A01, Rev. F MDS™ Master Station 21

3.6 Data Interface Connections

Ethernet Data Interface (RJ-45)

The Ethernet interface supports both radio management and payload data transport functions. For radio management, connecting via a web browser provides enhanced functionality and ease­of-use over serial/USB methods. Web-based management is the preferred and primary means of accessing the transceiver through the built-in Device Manager. SSH may also be used on this connector, and provides the same CLI based user interface available via the serial/USB interfaces. See section Ethernet Interfaces on Page 97 for electrical information and connector pinout.

Serial Data Interfaces

COM1 and COM2 provided on the front of the Platform Manager module serve as the serial
interface ports for payload data, radio management, or diagnostics. Management is also available through the mini USB port. The default factory configuration for these serial ports depend on the type of radio modules that are installed.
Table 3-3. Default Serial Port Assignment
Product variant
COM1
COM2
MPRS
Serial Payload Data
System Console
MPRL
System Console
System Console
These ports are user-configurable for specific applications. The procedures for changing their default operation are provided later in this guide.
Not all PCs have a serial port. If one is not available, a USB-to-Serial adapter and appropriate driver software may be used to provide serial connectivity. These adapters are available from several manufacturers, including GE MDS.

MPRS Serial Data Connection

When used as a data port for an SD Radio Module in Transparent or x710 modes, some pins on COM1 and COM2 have special behavior determined by configuration. DCD (Data Carrier Detect) is asserted when the radio received an on-frequency signal. RTS (Request-to-Send) can be configured to key the transmitter when asserted. CTS (Clear-to-Send) can be configured to go
“high” after the programmed CTS delay time has elapsed (DCE), or can be configured to key
another connected radio when RF data arrives (CTS KEY) The included Com Port Adapter Cable 73-2434A25 can be used to convert the unit’s RJ-45 serial jack to a DB-9F type connector.
22 MDS™ Master Station MDS 05-6399A01, Rev. F
Table 3-4. RF-45 to DB-9F Pin Out
Signal
RJ-45
DB-9F
Standard RS-232
DSR
1 6 DSR
DCD
2 1 DCD
DTR
3 4 DTR
Ground
4 5 Ground
RXD
5 2 RXD
TXD
6 3 TXD
CTS
7 8 CTS
RTS
8 7 RTS
No connection
N.C. 9 RI

Mini USB

The Mini USB port can be used to management the radio through a scriptable command line interface (CLI) using the proper USB drivers available at www.gemds.com. Connect to the management PC using the included Mini USB Cable. Once the PC registers the device driver, the port will auto baud. The USB port provides CLI management only and cannot be used for network diagnostics or for payload data.

Alarm Output and 4-Wire Audio

Alarm and audio signals are provided on the Alarm or Alarm/Relay module. Refer to Table 6-20 for details on pinout and signal descriptions. Audio signaling and alarm outputs are software configurable. Refer to Section 5.0 Device Management for more information.
MDS 05-6399A01, Rev. F MDS™ Master Station 23

4.0 INSTALLATION PROCEDURES

This section presents the steps necessary for installing the radio and connecting it to associated equipment. After completing these steps, the radio is ready for in-service operation.

4.1 Unpacking and Inspection

Check the contents against the packing list secured to the outside of the shipping box. Accessories and spare parts kits, if any, are wrapped separately. Inspect all items for signs of damage. Save all packing materials in case you need to ship the radio in the future.

4.2 Installation Steps

The radio should be installed in a relatively clean, dust-free environment that allows easy access to the connectors and indicators. Air must pass freely over the rear heat sink and around the unit for proper cooling. Follow the steps below to install the unit and prepare it for initial startup.
The rear heat-sink will get hot under continuous or high duty-cycle transmission. Use caution handling the unit while in operation.
1. Mount the Unit. The unit may be rack-mounted (2U high) in a 19-inch rack cabinet, or
may be placed on any sturdy tabletop or other flat surface. The installation site should be free of excessive dust, and should have adequate ventilation. The chassis should be positioned so that all interface cabling will reach the required connectors.
a. When rack mounting, the rack ears can be installed in one of three positions to
allow flexibility in the mounted depth of the chassis. The unit should be mounted so as to maximize airflow around the rear heat sink.
2. Ground the Chassis. Use the ground screw provided at the rear panel to connect the
radio to a safety ground (NEC Class 2 compliant), which bonds the Master Station, antenna system, and connected data equipment to a single-point ground. Keep all ground leads as short as possible.
3. Connect Antenna Feedlines. All coaxial antenna connections are made to the Type-N
connectors on the rear of the unit. The number of connections depends on options ordered, including duplexer options, as follows: Separate TX and RX; Combined TX/RX; wired for an external notch filter with RX Out, RX In and combined TX/RX.
24 MDS™ Master Station MDS 05-6399A01, Rev. F
Figure 4-1. Internal Duplexer, Triple N connectors
Figure 4-2. Internal Duplexer (or internal T/R switch), Single N connector
Figure 4-3 External duplexer or dual antennas, Double C connectors
(TX and RX ports pass directly through)
4. Install the Data Interface Cabling. Interface connections are made to the front of the
Platform Manager module. Typical connections for most sites include:
MDS 05-6399A01, Rev. F MDS™ Master Station 25
- Serial DataAttach data equipment to the front panel COM1 and/or COM2
ports. The unit is hardwired as a DCE device (DB9-F to RJ-45 connector, GE MDS part no. 73-2434A25).
- Ethernet LANAttach data equipment to the ETH1 and/or ETH2 port. The
auto-sensing MDIX feature allows either a straight-through or crossover cable to be used.
Where applicable in the steps that follow, secure all cable connections with the locking screws provided.
5. Connect Primary PowerThe Master Station is powered using one or two power
supply modules that work in tandem. The modules may be AC, DC, or a combination of both. The following tables list each type and key operating parameters.
Table 4-1. AC Power Supply Module
Module
Input Power
Current Rating
6755
100-220 VAC, 50/60 Hz
120W Max.
All DC power supply modules have chassis isolated inputs and a diode bridge for floating ground, positive ground, or negative ground installations. These modules include a keyed power connector with screw-terminals. Strip the wire leads to 6mm (1/4 inch) and insert them into the wire ports provided. Be sure to observe the polarity shown below. Tighten the binding screws securely and insert the connector into the module. For compliance with CSA, torque thumbscrews to 10in-lbs.
Table 4-2. DC Power Supply Modules
Module
Input Power
Current Rating
6843
+/- 12-36 VDC
10 A Max.
6844
+/- 36-75 VDC
3.5 A Max.
6845
+/- 75-140 VDC
2 A Max.
26 MDS™ Master Station MDS 05-6399A01, Rev. F
Figure 4-4 DC Power Connector
6. Connect a PC for Configuration (LAN or USB port). This prepares the Master Station for
programming of desired operating parameters. Configuration is further described in Section 5.0 Device Management
If serial-based cabling is used for configuration, an adapter may be required at the PC, as many PCs do not offer a serial port. In such cases, a USB-to-Serial adapter (with appropriate driver software) may be used. These adapters are available from a number of manufacturers.
7. Radio, Alarm/Relay, and Duplexer ConnectionsThe Alarm/Relay module provides
two alarm outputs, one for major and one for minor alarms. This module also provides TX/RX audio, PTT (TX keying), and analog RSSI connections. See Alarm/Audio Interface” on Page 110 for pinout connections.
All other required connections on the front of the unit are cabled at the factory per
ordered options.
8. Add connection of battery backup, as applicable.

Initial Startup & Operation

The radio is designed for continuous, unattended operation, but does require some minimal provisioning before operation. This section explains the use of the radio’s indicators and provides steps for initial startup of the equipment. Once a unit is provisioned, operator intervention is not required, except to power the unit up or down, or to change an operating parameter. Operation of the radio can be started by simply connecting primary power to the unit.

Module LED Indicators

All LED indicators are on the front of the unit. Platform Manager, Radio, and Alarm Modules include LEDs. A redundant unit will be populated as shown above. A non-redundant unit will have only one Radio Module and a different Alarm Module without RF connections.
MDS 05-6399A01, Rev. F MDS™ Master Station 27
Figure 4-5 LED Indicators

Normal Indications

When power is first applied, the following events occur in a normally working unit:
All front panel indicators light briefly
The ACTIVE LED for the selected transceiver board lights.
On SD radio modules, The Power LED will begin to flash indicating they have not yet
communicated with the platform manager.
The Power LED and Alarm LED will light on the Platform Manager card. At this point the
platform manager is performing a pre-boot validation of the firmware to ensure that all required security signatures are in place and valid.
The Alarm LED will turn off and the Power LED will begin to flash. At this point the platform
manager is booting and initializing the system.
Once the platform manager initializes the transceiver module, the Power LED will stop
flashing and turn solid.

Maximizing RSSI

Since the Master Station almost always uses an omni-directional antenna, maximizing signal strength is done at the remote sites where directional antennas are typically used. An RSSI stronger than -90 dBm is desirable. Refer to Section 5.0 Device Management for information on monitoring the RSSI for the Radio Module.
COM1
COM2
6834
ETH1
ETH2
USB
GPS
PWR ALARM
WiFi
6846
ACTIVE TX
PWR/ALARM
RX
RF
RX
TX/RX
6846
ACTIVE TX
PWR/ALARM
RX
RF
RX
TX/RX
A
B
OUT
6847
Alarm/Audio
ALARM
ACT
A B
MAJ
MIN
A
B
AUTO
28 MDS™ Master Station MDS 05-6399A01, Rev. F

5.0 DEVICE MANAGEMENT

This section describes the steps for connecting a PC, logging in, and setting unit parameters. The focus here is on the local serial/USB console interface, but other methods of connection are available and offer similar capabilities. The key differences are with initial access and appearance of data. The MDS™ Master Station offers several interfaces to allow device configuration and monitoring of status and performance. These include local serial console, USB, NETCONF, HTTP/HTTPS, and Secure Shell (SSH) for local and remote access via the WAN and LAN networks. The serial console, USB, and SSH services offer a command line interface (CLI). There are three user accounts/roles for management access: admin, tech, and oper. User accounts can be centrally managed with a RADIUS server, with RADIUS accounts being mapped to one of the three user accounts/roles. Refer to MDS Orbit MCR Technical Manual (05-6632A01) for details on configuring RADIUS authentication.
The MDS Master Station is designed for high security environments. As such, management of the device does not support Telnet, but instead implements the more secure SSH protocol.

5.1 Pre-Configured Settings

The unit is highly configurable to meet field requirements, but comes pre-configured as follows:
COM1 is configured at a baud rate of 115200, 8N1 for transparent serial payload for MPRS
master stations, and local console for MPRL master stations.
COM2 is configured to operate at a baud rate of 115200, 8N1 and is enabled for local console
operation.
USB is enabled for local console operation (proper system drivers must be installed on the
PC connected to the MDS™ Master Station to use the USB port as a virtual serial device; these drivers are available from the GE MDS website).
The Ethernet ports are bridged together, with spanning-tree protocol either enabled
(MPRS), or disabled (MPRL), with a default IP address of 192.168.1.1/24.

5.2 One-Time “Recovery” Passwords

The MDS Orbit platform employs extensive security measures to prevent unauthorized access.
As such, there are no hidden manufacturer passwords or other “backdoors” found in less secure
products. If a password is lost, there is no way to access the unit, except by using a one-time password (OTP) for recovery. The user must create this OTP manually. Without a one-time password, the unit will not be accessible, and the hardware will need to be replaced. The factory will not be
able to assist you if a password is lost, so creating a one-time password is strongly encouraged.

One-Time Passwords: How They Work

One-time recovery passwords put control directly and exclusively in the user’s hands. They are similar to spare keys for a lock. If you make a spare key, and put it away safely, you can take it
out to quickly gain entry when your primary key is lost. If you don’t make a spare, you are
always at risk of locking yourself out.
MDS 05-6399A01, Rev. F MDS™ Master Station 29
A one-time recovery password is different from the one used to log into the unit on a routine basis. It is only for use when the primary password is lost or forgotten. When a one-time password is used to log in, that password is automatically revoked from the list of passwords created. (You may create up to five one-time passwords at one time, and more can be created if some get used). Once used, a password cannot be used again for log-in to the unit (hence the name “one-time” password)

Creating a One-Time Password

To create a one-time recovery password via the console, enter the following command, where <selected function> is either “factory-reset” or “login”
> request system recovery one-time-passwords create function selected function
A one-time password is automatically generated and displayed on the screen. Copy this password and save it in the desired location on your PC. There is no way to ever view it again from the command line console, so be sure it is properly saved.
To create additional one-time passwords (up to a total of five), repeat the step above.

Logging in With a One-Time Password

Logging in with a one-time password can only be performed from the local serial or USB console. Note the local serial cannot be used if configured as a payload or diagnostic interfaces for SD radios (MPRS). You also cannot use a one-time password when connecting to the unit remotely. Therefore, in some configurations, the USB console is the only option. To use the one-time password for log-in, proceed as follows:
At the username prompt, enter the word recovery.
At the password prompt, paste in the one-time-password saved earlier on your PC. Using a
one-time-password forces the unit to perform the “function” which was previously defined when the password was created:
factory-reset—The unit resets its entire configuration to factory defaults
login—The unit allows logging in with “admin” privileges
Special case: If someone has disabled console access on the USB port, the login prompt will still be present on that console, but only one-time-passwords will be accepted. This is done to provide a way to recover the unit in the case where the USB port has been disabled and the unit cannot be accessed via TCP (for example; SSH).

Deleting a One-Time Password

As noted earlier, a one-time password is automatically revoked when it is used for log-in. A revoked password may be replaced, but it must first be removed from the list so a new one can be generated. Any of the five stored passwords may be removed on demand. As long as there is a free slot, an additional password can be created, up to the maximum number of five. Logs are generated when the user creates, deletes, or logs in with a one-time-password. To remove an existing password from the list, proceed as follows:
Enter the command request system recovery one-time-passwords delete identifier <X>, where <X> is a
number from the currently available one-time passwords. This identifier is not reused. If all five passwords have been created, then ID 1 can be deleted, and the next created password will be at ID 6.
30 MDS™ Master Station MDS 05-6399A01, Rev. F
The current list of passwords may be viewed by issuing the command show system recovery one-
time-passwords. The following is an example output from that command. On the unit shown, only
two passwords have been stored. Password 1 or 2 can be deleted from this list.
IDENTIFIER FUNCTION STATUS DATE CREATED DATE REVOKED USER
---------------------------------------------------------------------­1 login usable 2012-06-19T00:27:24+00:00 2 login usable 2012-06-19T00:27:25+00:00

5.3 Configuration via Command Line (CLI)

A scriptable command-line interface is accessible through the radio’s Ethernet port using Secure Shell (SSH) terminal, or through the unit’s USB interface. For enhanced security, the unit does
not support Telnet configuration. The steps below describe a cabled USB connection and assume the proper drivers have been installed.
1. Install the USB virtual serial port driver, which is available on the GE MDS web site.
2. Connect a PC to the unit's USB port and establish a console terminal session using a
serial communications program.
3. Press the ENTER key to receive the login prompt.
4. Enter the username (admin is the default username) and press ENTER.
5. At the Password prompt, enter the password (admin is the default password). Press ENTER.
Upon successful login, the connection message appears.
6. Enter the configuration mode by typing configure followed by the ENTER key.
7. Review and configure all key settings for the required application. Built-in help is
available by pressing the Tab key. A summary of all unit settings may be viewed by entering the % show | details command.

Tab Completion Feature

Tab-completion is a powerful feature that provides assistance when typing commands in CLI.
Depending on the text that was already entered, tab-completion displays different possible completions. When the Tab key is pressed and no text has been entered, the CLI shows all possible commands that can be typed.

CLI Quick Reference Table

Table 5-1. CLI Quick Reference Table provides a summary listing of commonly needed tasks and the appropriate commands to enter. The table can be used as a quick reference before consulting the more detailed information, which follows in this section. Each CLI command is preceded by the symbol > for operational command, or % for a configuration command.
Table 5-1. CLI Quick Reference Table
If you wish to...
Enter this CLI command:
Create a one-time password
> request system recovery one-time-password create function <user function>
View all network interface status and statistics
> show interfaces-state interface
MDS 05-6399A01, Rev. F MDS™ Master Station 31
Table 5-1. CLI Quick Reference Table
If you wish to...
Enter this CLI command:
Create a bridge
% set interfaces interface bridge type bridge
Add the ETH1 interface to a bridge
% set interfaces interface bridge bridge-settings members port eth-0/0/0
Remove the ETH1 interface from a bridge
% delete interfaces interface bridge bridge-settings members port eth­0/0/0
View LNMS settings
> show configuration interfaces interface lnms ln-config
Monitor LNMS Status (RSSI,EVM, etc)
> show interfaces-state interface lnms ln-status | repeat 5
NOTE: pressing ctrl-c will abort this command
Configure LNMS Frequencies
% set interfaces interface lnms ln-config rx-frequency <value> and/or % set interfaces interface lnms ln-config tx-frequency <value>
Configure LNMS Radio Power
% set interfaces interface lnms ln-config power <value>
View SDMS Settings
> show configuration interfaces interface sdms sd-config
Monitor SDMS Status (RSSI, SNR, etc)
> show interfaces-state interface sdms sd-status | repeat 5
NOTE: pressing ctrl-c will abort this command
Configure SDMS Frequencies
% set interfaces interface sdms sd-config radio-config basic-config receive-frequency <value>
and/or % set interfaces interface sdms sd-config radio-config basic-config
transmit-frequency <value>
Configure SDMS Modem
% set interfaces interface sdms sd-config radio-config basic-config modem-type <modem>
Configure the SDMS Radio Mode
% set interfaces interface sdms sd-config radio-config basic-config radio-mode <radio mode>
Configure SDMS Radio Power
% set interfaces interface sdms sd-config radio-config basic-config rf­output-power <value>
Key/Dkey the SDMS Radio
> request interfaces interface sdms sd-config maintenance rf-key-test key radio true/false
Send a Remote Maintenance Request to Remotes
> request interfaces interface sdms sd-config maintenance remote­management-command <command name> <value>
View the routing table
> show routing
View the event log
> show table logging event-log
Set the admin user’s
password
> request system authentication change-password user admin password admin1234
Set the device name
% set system name “Mydevice
Set the baud rate on COM1
% set services serial ports COM1 baud-rate b19200
Download a firmware package from TFTP server at
192.168.1.10
> request system firmware reprogram-inactive-image filename sdms­bkrc-1_0_0.mpk manual-file-server { tftp { address 192.168.1.10 } }
Monitor firmware download status
> show system firmware reprogramming-status
Export configuration file to a TFTP server at 192.168.1.10
> request system configuration-files export filename myConfig.xml manual-file-server {tftp {address 192.168.1.10} }
32 MDS™ Master Station MDS 05-6399A01, Rev. F
Table 5-1. CLI Quick Reference Table
If you wish to...
Enter this CLI command:
Reboot device to firmware inactive image
> request system power restart inactive

5.4 Interface Naming

Interface naming of physical devices on the MDS Master Station uses the following format:
<type>-<slot>/0/<port>
Where type is one of the following values:
Interface Type Abbreviations
Type
Description
eth
Ethernet Interface
sd
SD Radio Module
ln
LN Radio Module
wifi
WiFi Interface
Slot-0 is the slot identifier for the platform manager, while slots 1-3 map to the available interface slots in the chassis.
Ports are zero-based and map to the port number of the given interface type in the specified slot. Note that not all interface types have port values that are non-zero (e.g. An SD radio module only has one “port”, so it will always be ‘0’)
The center 0 value in the interface name is always 0, and is reserved for future use. Examples of valid interface names are
eth-0/0/0 – The first Ethernet port on the platform manger card in slot-0
eth-0/0/1 – The second Ethernet port on the platform manager card in slot-0
sd-2/0/0 – The SD Radio module in slot-2.
ln-1/0/0 – The LN Radio module in slot-1
Logical (non-physical) interfaces such as bridges and VLANs use free-form names and can be renamed by the user.

5.5 Configuration via the Device Manager

The Device Manager is a built-in software tool that works with your PC’s browser to provide an intuitive, web-style presentation of all unit information, settings, and diagnostics. Device manager is accessible through ETH1 or ETH2 using a web browser. Minimum browser requirements: IE10 or later, Chrome, Firefox, or Safari.
For security, web access can be enabled/disabled via the CLI using the command % set
MDS 05-6399A01, Rev. F MDS™ Master Station 33
services web http(s) enabled true/false

General Configuration

For initial configuration of the Master Station, perform the following steps:
1. Connect the unit to a PC via an Ethernet connection.
2. Configure your PC network settings to an IP address on the same subnet as the unit. The
default subnet mask is 255.255.255.0.
For IP addressing the Master Station uses a routing prefix expressed in CIDR notation instead of specifying a subnet mask. The CIDR notation is the first address of a network, followed by a slash character (/), and ending with the bit-length (max 32) of the prefix. A subnet mask is expressed in dot-decimal notation. For example, 192.168.1.0/24 is equivalent to specifying 192.168.1.0 with a subnet mask of 255.255.255.0.
3. Open a web browser and navigate to the IP address of the unit (default Ethernet IP
address is 192.168.1.1). The initial sign-in prompt appears.
4. Enter the username and password (admin is the default entry for both fields), then click
‘Sign In’.
5. On first-time login, the Initial Setup Wizard will appear and provide guidance for general
device setup. This is disabled after the initial setup has been complete but may be re-run at any time by accessing the Wizards link on the left side of the screen, and clicking Initial Setup.
Key items that should be reviewed and/or set for the radio include:
Create one-time programmable passwords for unit recovery
Change login passwords (to maintain security)
Evaluate default factory configuration and lock the unit down to the required security level
When the Initial Setup wizard completes, to configure SD interfaces (MPRS), select WizardsSD Setup, which steps you through initial SD Radio Module configuration. Key items that should be reviewed and/or set include:
Radio Mode
Frequency plan
Modem selection
Keying mode
Repeater Configuration (if necessary)
34 MDS™ Master Station MDS 05-6399A01, Rev. F
Serial data interface configuration
Encryption settings
Similarly Wizards Interface Setup will allow the user to configure the LN radio.

5.6 Interface Configuration

Understanding

A serial cable (RJ45 cable with proper ETH to DB9 converter) may be used to connect to a COM port on the unit to access the CLI. The default serial console settings are 115200 bps with 8N1 format. A mini-USB-to-USB cable may also be used to connect to a Computer in case no serial port exists. If a mini-USB connection is used, the computer must contain the appropriate device driver. A driver for serial operation can be found on GE MDS website.

Configuring

The screen below shows console access to the COM1 serial and USB port: Navigate to: Services  Serial  Basic Config
MDS 05-6399A01, Rev. F MDS™ Master Station 35
Clicking on the row of the port you wish to edit will present you with the following options:
Line Mode - Selection of the operation line mode of the serial port. Choices are:
- RS232 (DEFAULT)
- RS485 - 2 Wire
- RS485 - 4 Wire
Baud Rate - The serial port baud rate in bps. Choices are 300, 1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200 (DEFAULT), 230400
Byte Format - The data byte format in bits, parity and stop bits: Choices are:
- 7N1 - 7 char bits, no parity, 1 stop bit
- 7E1 - 7 char bits, even parity, 1 stop bit
- 7O1 - 7 char bits, odd parity, 1 stop bit
36 MDS™ Master Station MDS 05-6399A01, Rev. F
- 7N2 - 7 char bits, no parity, 2 stop bits
- 7E2 - 7 char bits, even parity, 2 stop bits
- 7O2 - 7 char bits, odd parity, 2 stop bits
- 8N1 - 8 char bits, no parity, 1 stop bit (DEFAULT)
- 8E1 - 8 char bits, even parity, 1 stop bit
- 8O1 - 8 char bits, odd parity, 1 stop bit
- 8N2 - 8 char bits, no parity, 2 stop bits
- 8E2 - 8 char bits, even parity, 2 stop bits
- 8O2 - 8 char bits, odd parity, 2 stop bits
Hw Flow Control - Hardware flow control enable/disable (DEFAULT) using RTS/CTS
lines
Vmin - Receive Buffer Size - The minimum number of data bytes that will be buffered by
the serial port before handling of the data to be processed by the terminal server. (255 = DEFAULT).
Vtime - Receive Inter-Byte Timeout - The amount of time between bytes of data on the
serial port (in multiples of 1 millisecond), that indicate the end of a serial message ready to be processed by the terminal server. (100 = DEFAULT)
Vmin and Vtime setting only have an effect when the serial port is not being used an
SD payload or diagnostics (DLINK) port,
Serial Hardware Flow Control
When serial port is not being used as a SD payload or SD diagnostics (DLINK) port:
Hardware Flow Control: When operating in CTSKEY mode, all serial ports in the data path
are required to be set to the same baud rate, and that VMIN and VTIME remain at the defaults for serial data packets less than or equal to 255 bytes. For serial packets over 255 bytes it is recommended that a cts-delay time of at least 90ms be used to account for the VTIME delay of the over-the-air sending unit.
Hardware Flow Control Modes
When port is not being used as a SD payload or SD diagnostics (DLINK) port:
DCE
- CTS follows RTS after a programmable CTS delay.
- If the unit’s input buffer approaches a full condition it can deassert CTS
regardless of state of RTS.
CTSKEY
- Based on legacy MDS devices including TransNET, the device will act similar to
a DTE but will provide signaling on the CTS line instead of the RTS line.
- When the first character of a transmission is ready to be sent to the serial port, the
unit shall assert CTS and delay for CTS delay time expiration before outputting the first character.
- After the last character of a transmission is output from the serial port, the unit
shall keep CTS asserted until the expiration of CTS hold time.
CTSKEYPLUS
MDS 05-6399A01, Rev. F MDS™ Master Station 37
- The unit shall support flow control (Throttling) on the RTS pin. The device is
expected to be wired via null modem to an external DCE device. The CTS line of the external DCE device drives the RTS line of the unit.
Statistics for the Serial ports and IP Payload 1, 2, 3 are located under the active SD radio
interface (Interfaces sd-x/0/0 Status Statistics). See the section entitled
38 MDS™ Master Station MDS 05-6399A01, Rev. F
SD-x/0/0 Interfacesfor more details.

5.7 LAN

Understanding

This section will cover only the basic configuration of Ethernet ports and bridges. For full details on the configuration of more advanced features, please reference the MDS Orbit MCR Technical Manual (05-6632A01)
The Master Station has external Local Area Network (LAN) ports (ETH1/2 ports) that can be used to connect to a local (wired) LAN. It supports both IPv4 and IPv6 addresses and may be assigned multiple IP addresses. The LAN port can be assigned static IP addresses or a dynamically allocated address can be assigned using DHCP.
The LAN port should be assigned IP addresses only if it is a routed interface (that is, not in a bridge).

Configuring

To configure the LAN interface, select the eth-0/0/0 or eth-0/0/1. As shown in the screens below, there are five groups of configuration settings that can be configured: General ETHx specifics, IPV4, QOS, Filter, and NAT
Basic Config
Interfaces  eth-0/0/x  Basic Config
Figure 5-1. ETH1 Configuration Screen
Description - User defined identifier for this connection - 0-34 characters
Type - Identifier of the type of interface - Do Not Change
Enabled - Checked indicates Enabled (DEFAULT). Disable will prevent usage.
Eth Phy Rate - Choose the Ethernet speed support setting (DEFAULT ALL)
- Eth 10Mb Half
- Eth 10Mb Full
- Eth 100Mb Half
MDS 05-6399A01, Rev. F MDS™ Master Station 39
- Eth 100Mb Full
Vlan Mode - Virtual LAN Setting.
- None (DEFAULT)
- Access - Use this if this interface is intended to be a member of only a single
VLAN.
- Trunk - Use this if this interface is intended to be a member of multiple VLANs.
Enabled - Enable or disable the use of an IP address
Forwarding - Indicates if IPv4 packet forwarding is enabled or disabled on this interface.
True (DEFAULT) / False
Mtu - The size, in octets, of the largest IPv4 packet that the interface will send and
receive. Range 68-65535 - 1500 (DEFAULT). (Advanced setting)
Address - Use for creating static IPv4 IP address and removing this interface from the
built-in Network Bridge.
Neighbor- Use for creating mappings from IPv4 addresses to link-layer addresses.
40 MDS™ Master Station MDS 05-6399A01, Rev. F
Filter Input - Use for selecting and applying a firewall filter (from available filters) to
incoming traffic on this interface.
Filter Output - Use for selecting and applying a firewall filter (from available filters) to
outgoing traffic on this interface.
For more information on packet filtering, refer to “Access Control List (Packet Filtering / Firewall)” in the MDS Orbit MCR Technical Manual (05-6632A01)
Input - Default Selections (others may have been added) :
- IN_TRUSTED
- IN_UNTRUSTED
- OUT_TRUSTED
- OUT_UNTRUSTED
Output - Default Selections (others may have been added) :
- IN_TRUSTED
- IN_UNTRUSTED
- OUT_TRUSTED
- OUT_UNTRUSTED
See the MDS Orbit MCR Technical Manual (05-6632A01) for information on configuring NAT.
Output - Use for selecting and applying a QoS policy (from the available QoS policies) to
the outgoing traffic on this interface. See "Quality of Service (QoS)" in the MDS Orbit MCR Technical Manual (05-6632A01) for more information on creating QoS policies.

5.8 Bridging

Understanding

The unit supports transparent bridging of LAN, and in firmware versions of 3.0.0 and higher, WiFi and SD networks. The LN network supports Ethernet payload since its release in 4.0.0 The bridge forwards traffic between LAN interfaces and wireless interfaces at the layer-2 of OSI model. This allows LAN and wireless clients to be in the same IP sub-network.
MDS 05-6399A01, Rev. F MDS™ Master Station 41
The bridge learns the clients’ locations by analyzing the source address of incoming frames from all attached networks. For example, if a bridge sees a frame arrive on LAN port from Host A, the bridge concludes that Host A can be reached through the segment connected to LAN port. Through this process, the bridge builds a forwarding table (the learning process). When a frame is received on one of the bridge's interfaces, the bridge looks up the frame's destination address in its forwarding table. If the table contains an association between the destination address and any of the bridge's ports aside from the one on which the frame was received, the frame is forwarded out the indicated port. If no association is found, the frame is flooded to all ports except the inbound port. Broadcasts and multicast also are flooded in this way. The bridged network is addressable via the ‘bridge interface (a virtual interface). The interfaces that are in the bridge are called bridged interfaces. The interfaces that are not in the bridge are called routed interfaces. Bridging is performed between bridged interfaces. Routing is performed between routed interfaces. The bridge interface itself is a routed interface.
In firmware versions less than 3.0.0, the SD interface is not a bridgeable interface as there is no packet or packet-with-MAC mode support in these versions of firmware.

Configuring

For full details on configuring bridge interfaces, please see the MDS Orbit MCR Technical Manual (05-6632A01).

5.9 SDMS Interface

Understanding

The configuring of SD interfaces on the Master Station is performed through a virtual interface
called ‘sdms’ (SD Master Station). This virtual interface, much like a bridge interface, is
comprised of one or more sd-nic member physical interfaces. Each installed SDM Radio Module contains a single sd-nic. All configurations applied to the virtual SDMS interface will be propagated to all member sd-nic interfaces. This insures that all SD radio interfaces in the system are using identical configurations so that interface fail-over is seamless. To access the full suite of SD configuration options, select the sdms interface from the interfaces drawer on the left-hand menu.
Understanding the use of Virtual Radio Channels (VRCs)
VRCs allow over-the-air data to be directed to specific interface ports (IP or Serial) on the radio.
Conceptually, this can be pictured as creating “pipes” for delivery of data to the desired radio
interfaces. VRC works by associating data from a specific port (IP and Serial) with a VRC channel number (1, 2, or 3). Each port at the receiving end then filters incoming data based on the associated VRC number.
The Virtual Radio Channel (VRC) feature is only supported in Packet w/MAC modes. It is not supported in Transparent or x710 mode.
To create the “pipes” that direct data to the desired ports, a route must be established using the IP
Payload Configuration Menu (or payload serial settings on the general configuration menu for serial data). The default setting is to listen to all channels.) The Talk on parameter is used to specify the VRC used for sending the data stream over the air, while the Listen to parameter specifies the VRC(s) for incoming data.
42 MDS™ Master Station MDS 05-6399A01, Rev. F
Any combination of the three VRC numbers may be entered in the selection fields. Figure 5-2. Virtual Radio Channel (VRC) Concept illustrates the relationship between the VRC settings and the routing of data between units.
Figure 5-2. Virtual Radio Channel (VRC) Concept
Understanding the use of Media Access Control (MAC)
An important feature of the transceiver is Media Access Control (MAC). The radio’s MAC is
specifically designed for use with narrow bandwidth, half duplex radio networks such as those commonly used in licensed telemetry systems. When the MAC is enabled, it provides efficient support of multiple data traffic models including multiple hosts, synchronous and asynchronous polls, and report-by-exception (push traffic). MAC ensures that every transceiver in the network has an equal probability of gaining access to the radio channel when it has data to send.
Coordination of Channel Access
The main objective of the MAC is to coordinate channel access for all radios in the network,
preventing data “collisions” that can occur with simultaneous transmissions from radios on the
same RF channel. With MAC operation, a single radio is configured as an Access Point (AP) and other units are designated as Remotes. The AP serves as the controller of the RF network. Remotes request permission from the AP to use the RF channel before sending payload data, thus avoiding collisions of data, and creating a highly reliable wireless network. The MAC is responsible for allocating which unit gets access to the broadcast medium (the RF channel), when, and for how long.
Data Validation
Additionally, the MAC validates all messages and purges corrupted data from the system. Successful delivery of data is ensured through the use of retries and acknowledgements. Minimal
MDS 05-6399A01, Rev. F MDS™ Master Station 43
overhead is used to accomplish these tasks, which translates to increased bandwidth efficiency of the radio channel with minimal latency, ensuring that messages are delivered in a timely manner.
Status Tab
The Status tab on the sdms interface page gives an overview of the current state of the sdms interface. The information displayed is described below:
General
This section shows a general overview of the SDMS interface. The current status of the relay switch, as well as which SD NIC is currently active is displayed here.
The NIC Status table is composed of the following columns:
Chassis Slot – The slot in which the SD NIC was discovered.
Board Temperature – The current temperature in degrees C as measured on the surface
of the SD NIC. The colored indicator will transition to yellow and red as the NIC approaches its operational limits.
PA Temperature – The current temperature in degrees C of the power amplifier on the
SD NIC. The colored indicator will transition to yellow and red as the NIC approaches its operational limits.

Configuration

From the sdms interface page, all SD related configuration options can be specified. Primary SD
network configuration can be found under the ‘Basic Configtab, more advanced options can be
found under the “Advanced Config” tab, and operational actions can be found under the
“Actions” tab.
44 MDS™ Master Station MDS 05-6399A01, Rev. F
Basic Config Tab

General Settings

The Basic Settings contains important RF and modem selections for radio operation.
Members – The Master Station (sdms) interface is a logical interface that is composed of
one or more physical SD interface cards (sd-nic). The ‘members’ configuration item is the mapping between the logical sdms interface, and the physical sd-nic cards. A single sd-nic resides in each SDM Radio Module.
MDS 05-6399A01, Rev. F MDS™ Master Station 45
This is factory configured to contain SDM Radio Modules in slot 1 and slot 2 of the Master Station. If the Master Station is a non-redundant system with only 1 Radio Module, this will contain only ‘sd-1/0/0’.
Radio Mode – The radio can operate in one of several modes. The available selections
are:
- Packet with MAC – With and without AES Encryption
- x710 – When using the Master Station in a legacy x710 network.
- Transparent – With and without AES Encryption. (Transparent w/AES
Encryption requires an all SD radio network.)
Modem Type – This setting determines the over-the-air data speed and bandwidth of the
radio’s transmitted signal. All radios in the network must use the same modem setting to
communicate with each other. The default setting is Modem 9600, but it may be set to any of the selections shown in Table 5-2. Modem Selection vs. Speed, Bandwidth & Sensitivity. The table also lists modem sensitivity ratings for the various modems. Note that some modem choices are limited based on the model purchased.
RF Output Power (dBm) – The RF output power may be set between 30 and 40 dBm (1
to 10 watts) in 1 dBm increments. The default setting is 40dBm. This setting represents the output power at the Radio Module. Output power at the antenna port on the back of the unit will be roughly 2dB to3dB less depending on configuration. This is due to cable, switching, and duplexer losses. Full power is not required in many cases, and lower settings will place less demand on the power supply and reduce the chance of interference with other stations. Only the power necessary to carry out reliable communications should be used.
Transmit/Receive Frequency – The receive and transmit frequencies may be viewed or
set here. Frequencies must be entered for the radio to operate. Consult your station license to determine the authorized frequencies for your system, and enter them exactly as listed.
Keying Mode – Keying mode must be set to one of the following values:
- Data – Radio will key upon receipt of payload data.
- RTS – Radio will key upon receipt of an RTS (request to send) signal on the
serial port.
RTS keying mode is only supported when the radio is in x710 mode.
- Data or RTS – Radio will key upon receipt of either payload data or an RTS
(request to send) signal on the serial port.
- Continuous – Radio will be continuously keyed. This is primarily used in a
transparent streaming repeater configuration.
Continuous keying mode is only supported in x710 mode, or in transparent mode when operating as a repeater.
System ID – Provides the possibility for Frequency Re-use. System ID offers nine unique
choices including the default value of NONE. The setting NONE is required for mixed networks comprised of MDS legacy and SD products. SD-only networks can utilize the Frequency Re-use feature by setting the System ID to a common value [1-8] for all radios in a specific network. System ID offers approximately 20 dB of additional co-channel isolation when operating networks on the same frequency. Note that proper system design is required.
46 MDS™ Master Station MDS 05-6399A01, Rev. F
Operational Example: SD System “Alpha” has eight units and SD System “Beta” has eight units. A user wishes to occupy frequency 952.1235 MHz on both of these systems.
Proper system installation has been adhered to in both networks. System Alpha’s units
would all be set to System ID = 1, System Beta's units would be set to System ID = 5. Both systems will now operate on the same desired frequency. Examples of valid and invalid arrangements are shown in Figure 5-3 and Figure 5-4, respectively.
Figure 5-3. System ID Example Valid Arrangement
Figure 5-4. System ID Example Invalid Arrangement
FCC Part 90 Repeater Mode – Repeater mode must be set to one of the following
values:
MDS 05-6399A01, Rev. F MDS™ Master Station 47
- None – This is the default value, and is used when the Master Station being
configured is not to be used as a repeater in the network.
- Repeater – This value should be selected when the Master Station being
configured is to be installed as a repeater in the network, and will not have devices connected to it that will be polled, such as attached RTUs.
- Repeater With Local Data – This is the same as “Repeater” but should be used
when data-collection devices such as serial RTUs will be attached directly to the repeating Master Station.
Allowed Ethernet Packet Types – When operating in packet-with-mac mode, and
sending Ethernet traffic, this option will restrict the types of Ethernet frames that will be sent over the air. Options are:
- None – This will prevent any Ethernet frames from being transmitted over the air.
- All – All Ethernet frames will be sent over the air, regardless of type.
- Unicast Only – Only unicast packets will be sent over the air.
- Unicast and ARP – This is the default value and will only allow unicast frames,
or broadcast ARPs to be transmitted over the air.
Serial Payload Port – The front-panel serial port that will be used for serial payload
communications. This can be set to COM1, COM2, or disabled if the system will not be used for transmitting serial data. The default value for this is COM1.
Serial port settings such as baud rate and byte format are located under Services
Serial Ports.
Payload Buffer – The transceiver’s buffer provides a way of handling data 'over-runs',
where more data is passing through the COM port than can be immediately handled by the unit. When the payload-buffer is on, any such data is stored up and processed in the appropriate order.
Payload Serial Talk VRC / Payload Serial Talk 2 VRC – Serial data received on the
primary/secondary serial payload port will be tagged with this VRC and sent over-the-air.
Payload Serial Listen VRC / Payload Serial Listen 2 VRC – Over-the-air payload
traffic that is tagged with this VRC that the Master Station receives will be transmitted out of the primary payload serial port.
Encryption – When the Master Station is being used in a network of only SD radios,
over-the-air (OTA) encryption may be enabled. The Master Station uses AES-128, passphrase-based encryption to secure both payload, and Dlink traffic. If the radio is operating in transparent mode, there is a separate passphrase for payload and Dlink traffic. If the radio is operating in packet or packet-with-MAC mode, there is a singular passphrase for all traffic.
Payload Encryption Phrase – The encryption phrase to be used for over-the-air payload
data. This string must be at least 8 characters, and no greater than 38 characters.
48 MDS™ Master Station MDS 05-6399A01, Rev. F
Table 5-2. Modem Selection vs. Speed, Bandwidth & Sensitivity
Modem Type Selection
Over-the-air Speed (bps)
B/W (kHz)
Approximate Sensitivity (dBm)
ETSI Compliance
BELL
1
1200
12.5
-110
V23
1200
12.5
-110
3200
1, 2
3200
5.00
-108
4800B
1
4800
12.5
-110
4800F
4800
6.25
-108
9600B
1
9600
12.5
-106
9600
1
9600
12.5
-112
9600N
9600
6.25
-98 19200N
19200
12.5
-100
19200
19200
25
-105
38400N
38400
25
-99 65000
3
65000
50
See note 3
4800
1
4800
12.5
-112
X
9600M
1
9600
12.5
-106
X
19200E
19200
12.5
-96 X 19200M
19200
25
-106
X
38400E
38400
25
-97
X
1. For MDS x710-compatible operation.
2. 3200 bps not applicable to SD4.
3. Only available with SDM9D Radio Modules.

Dlink

Dlink is a GE MDS-proprietary protocol used for diagnostics communications.
MDS 05-6399A01, Rev. F MDS™ Master Station 49
Unit – This parameter identifies the radio in the wireless network with a specific ID
during diagnostic sessions. For compatibility with legacy devices, the value must be 10000 or greater (2710 in hexadecimal).
Type – This setting identifies the radio as a Node, Root, Repeater, Peer, or Gate. Each of
these are operating modes of the transceiver with respect to diagnostic/management activities.
Mode – Configure if Dlink will operate on a serial port, or via a TCP socket.
Serial Mode Settings:
- Serial Port This setting determines which serial port to use COM1 or COM2.
This must be different than the serial payload port.
TCP Mode Settings:
- Security Mode – When set to a value other than none, connections will be
encrypted using a pre-shared key via TLS. The version specified by this parameter will be only version allowed by the server.
- TCP Port – The TCP port that the Dlink service will listen on.
- IPv4 Addr – Optionally configure the service to only attach to the specified IPv4
Address. This is useful when traffic is being separated into data and management VLANs. If no value is specified, the service will accept connections on all configured IP addresses.
- IPv6 Addr – Optionally configure the service to only attach to the specified IPv6
Address. This is useful when traffic is being separated into data and management VLANs. If no value is specified, the service will accept connections on all configured IP addresses.
Enabled – Enable or disable diagnostics functionality. Setting it to ON configures the
radio to pass the diagnostic link protocol (DLINK) over the radio’s COM2 management
port.

MAC Settings

When operating in packet with MAC mode, MAC specific settings can be configured here.
50 MDS™ Master Station MDS 05-6399A01, Rev. F
Device Type – The role this device will be performing in the network. If this device is
operating as a repeater, the MAC device type MUST be 'remote'.
MAC Retries – If a message is not acknowledged after transmission it will be resent. This
value controls how many times the radio attempts to resend the message before discarding it.
Time to Live – When a message arrives from the payload interface(s) it is time-stamped
and queued for radio transmission. If the radio cannot transmit the message before the Time-to-Live (TTL) value (in seconds), the message is discarded. This helps prevent stale or old data from being sent over the air.
SAF Network (Access Point only) – If this device is in use in a Store-And-Forward
network, enable this option.
Repeater Network (Access Point only) – If this device is in use in a repeater network,
enable this option.
Payload 1/2 Inter Packet Gap – The inter-packet gap is a timing setting in ms used to
delimit a packet on the serial interface. Too short of a time can cause serial streams to be combined into one large packet instead of two smaller ones. Too long of a time can slow down the communications channel.
Transparent Rx Timeout – This setting is similar to the timing parameters for Payload
1/2 Inter-Packet Gap, but it applies to data received over-the-air. It tells the radio how to build an Ethernet packet based on a transparent data stream received over the radio channel.
Peer to Peer
Access Point Options:
MDS 05-6399A01, Rev. F MDS™ Master Station 51
- Peer to Peer Enabled – If enabled, the AP will allow enabled peers to send
traffic through the AP to other enabled peers by rebroadcasting their transmissions to all other remotes in the system.
- Ethernet Rebroadcast Type – When rebroadcasting peer-to-peer Ethernet
traffic, only the selected type of traffic will be rebroadcast to other remotes on the network.
Remote Options:
- Rebroadcast Serial – If enabled, serial traffic originating from this device will be
rebroadcast by the AP to other remotes in the network. The AP must have peer­to-peer rebroadcasting enabled.
- Rebroadcast Ethernet – If enabled, Ethernet traffic originating from this device
will be rebroadcast by the AP to other remotes in the network. The AP must have peer-to-peer rebroadcasting enabled.

IP Payload

Under the IP Payload menu, up to three instances of the IP Payload service may be configured. The IP Payload service can operate in 4 different modes:
- TCP Server
- TCP Client
- TCP Server/Client
- UDP
Common Options:
Enabled – Set to true to enable this IP Payload configuration.
IP Payload Mode – The mode in which this instance of the IP Payload service should
operate. The details of these modes are shown below.
Talk on VRC – (Only in packet-with-mac mode) The Virtual Radio Channel that data
from this IP Payload instance will be tagged with when transmitted over the air.
Listen to VRC – (Only in packet-with-mac mode) Over-the-air data tagged with this
Virtual Radio Channel will be handled by this IP Payload instance.
Modbus TCP RTU Conversion – (Does not apply to UDP mode) When enabled, the IP
Payload server will convert packets between MODBUS TCP and MODBUS RTU formats.
Inactivity Timeout – When set to a value larger than 0, the connection will be closed
after the specified number of seconds without any data activity. Each of the IP Payload modes have different use cases and configuration options, as described below:
TCP Server:
The TCP server mode allows IP connections to be established with the Master Station. Data received on this TCP socket will be transmitted over the air to remote SD radios as if the data was received on the payload serial port of the Master Station. Over-the-air serial data originating from a remote SD radio will be transmitted out of this TCP socket. This mode of operation can
be thought of as a ‘remote terminal server’, not to be confused with the SD remote radio’s
Terminal Server functionality.
52 MDS™ Master Station MDS 05-6399A01, Rev. F
TCP Server specific configuration options include:
Local IP Port – The TCP port number that the server will listen for connections on.
IPv4 Bind IP – If the Master Station is configured with multiple IP interfaces; you can
specify that the IP Payload service only will listen for connections on one of the IP
addresses of the system. This is useful in VLAN configurations where you wish to only
make the IP Payload server available on a specific VLAN in the system.
TCP Client:
The TCP client mode allows the Master Station to connect to a TCP server when there is traffic to send. This mode of operation is not often used in Master Station configurations, but may be useful in certain applications.
MDS 05-6399A01, Rev. F MDS™ Master Station 53
TCP Client specific configuration options include:
Server IP Address – The IP address of the server the Master Station is to connect to.
Remote IP Port – The TCP port that the server is listening on.
TCP Server/Client:
As the name implies, TCP Server/Client is a combination of the TCP Server mode, and TCP Client mode. In this mode, the Master Station will listen for incoming TCP connections and pass data exactly as in TCP Server mode. However if there is no active server connection, and over­the-air payload traffic arrives at the Master Station, the Master Station will establish an outgoing TCP connection to a remote server and transmit that data to the remote server. A use-case for this mode of operation is if you wish to have the protocol reliability of TCP, but do not wish to maintain active TCP sessions across your network.
TCP Server/Client specific configuration options include:
Local IP Port – The TCP port number that the server will listen for connections on.
Server IP Address – The IP address of the server the Master Station is to connect to.
Remote IP Port – The TCP port that the server is listening on.
IPv4 Bind IP – If the Master Station is configured with multiple IP interfaces; you can
specify that the IP Payload service only will listen for connections on one of the IP
addresses of the system. This is useful in VLAN configurations where you wish to only
make the IP Payload server available on a specific VLAN in the system. UDP: When operating in UDP mode, the IP Payload service uses the connectionless UDP protocol. Since UDP is connectionless, there must be receiving sockets at each end of the connection to allow for bi-directional communications. In this mode, when an application has traffic to send out over the SD network, it will establish a UDP connection to the Master Station and transmit
54 MDS™ Master Station MDS 05-6399A01, Rev. F
the payload data. When the Master Station receives over-the-air payload data from remote SD radios, the Master Station will establish a UDP connection to the application and transmit the payload data. These connections are not persistent, and as such must be established for each transmission. Unlike TCP, transmissions are not guaranteed when using the UDP protocol; however UDP has a far smaller network overhead than TCP, and as such will result in lower latency.
UDP specific configuration options include:
Local IP Port – The UDP port number that the server will listen for connections on.
Server IP Address – The IP address of the server the Master Station is to connect to.
Remote IP Port – The UDP port that the server is listening on.
IPv4 Bind IP – If the Master Station is configured with multiple IP interfaces; you can
specify that the IP Payload service only will listen for connections on one of the IP
addresses of the system. This is useful in VLAN configurations where you wish to only
make the IP Payload server available on a specific VLAN in the system.
IPv4
This configuration section allows you to configure either a static or dynamic (DHCP) IPv4 address to the SDMS interface when it is not a member of a bridge or VLAN interface. For full information on applying IP addresses to interfaces, see the MDS Orbit MCR Technical Manual (05-6632A01).
MDS 05-6399A01, Rev. F MDS™ Master Station 55
Firewall Filter
The firewall filtering rules to apply to this interface when it is not a member of a bridge or VLAN interface. For full information on applying firewall filters to interfaces, see the MDS
Orbit MCR Technical Manual (05-6632A01).
VLAN
The VLAN configuration section is used to configure the SDMS interface to be a member of a VLAN. For full information on configuring VLANs and adding interfaces to existing VLANs, see the MDS Orbit MCR Technical Manual (05-6632A01).
56 MDS™ Master Station MDS 05-6399A01, Rev. F
NAT
The NAT configuration section is used to configure network address translation (NAT) on the SDMS interface. For full information on configuring NAT on interfaces, see the MDS Orbit
MCR Technical Manual (05-6632A01).
MDS 05-6399A01, Rev. F MDS™ Master Station 57
Advanced Configuration Tab

Advanced Configuration

Soft-Carrier Dekey – Specifies how long (in ms) to wait after the removal of the keying
signal before actually dropping the transmitter’s carrier. The default setting is 0, but it may
be set to any value up to 255 ms. In most cases, no change is required from the default
setting. A possible exception is when the transceiver is inter-working with certain early-
generation MDS radio equipment.
Push to Talk Signal – Specifies the sensing polarity of the PTT line. This must be
configured to one of the following values:
- Off – PTT line is not used.
- Hi – The PTT line is active-high.
58 MDS™ Master Station MDS 05-6399A01, Rev. F
- Lo – The PTT line is active-low.
Push To Talk Delay – Specifies a brief time delay after a keying event, which must
expire before the radio is allowed to transmit. The allowable range is 0 to 255 ms, with the
default being 0.
Clear To Send Delay – Specifies a brief time delay between when an RTS (ready-to-
send) signal is received and when the CTS (clear-to-send) signal is returned. The
allowable range is 0 to 255 ms, and the default is 0.
Automatic Freq. Correction – Automatic Frequency Correction, is used to counteract the
slight RF frequency drift that may occur over time or through wide swings of ambient
temperature. AFC should only be enabled when operating this device as a remote, as all
remotes in the system use AFC to track the master station frequency. Under normal
operation, the modem is capable of compensating for small frequency errors even with
this mode disabled. Enabling AFC further extends the frequency capture range when
operating with legacy hardware that may have significant frequency error.
Switched Carrier B Modems – In some networks, the Master unit is not keyed
continuously (Ckeyed), and transmits only when it has data to send to Remotes. This is
known as Switched Carrier operation. The Switched Carrier setting is only for use with the
9600B modem (for compatibility with MDS x710 radios). In such networks, the Remote
radios should have the Switched Carrier setting turned ON. The default setting is OFF
which assumes B-modem operation with a continuously keyed Master. Ckey operation
only applies to Master units operating full-duplex and does not apply to legacy-packet or
packet with MAC modes. When operating continuously keyed, latency is decreased and
AFC operation on legacy remotes may be improved. Switched carrier operation, when low
latency is not required, is recommended when operating in high ambient conditions to
reduce power consumption and heating.
Force DCD to Asserted – Some systems require a constant Data Carrier Detect (DCD)
signal. This setting allows the radio to be configured to provide a DCD signal without the
need for special cabling.
Enabling Force DCD to Asserted will cause the RX LED on the radio interface to turn on, regardless of whether the radio is receiving data or not.
Data Key Hold Time-out – When operating in data key mode, this parameter specifies
the number of character-times the transmitter will remain keyed for after the last character
it receives. For networks with the demand for a higher modem speed than the baud rate of
the serial port, this parameter can be adjusted from 1 to 10 characters. This parameter
gives the overall network better performance by preventing frequent key-up and key-down
sequences between characters. This only applies to networks with all SD radios.
Simplex Mode – This controls whether or not the Master Station will be running in
simplex (switched carrier) or full duplex mode. When simplex is enabled, TX and RX are
switched onto a single RF interface. A Master Station without an internal duplexer with a
single antenna output must have simplex mode enabled.
Dlink Mode (B Modems) – Legacy products that only support B-Modems do not have
support for Dlink. Newer products such as the MDS SD have the ability to support Dlink
even when using B-Modems. Depending on site-specific requirements, this value may
MDS 05-6399A01, Rev. F MDS™ Master Station 59
need to be changed to ‘bypassed’ in order to work with legacy products. It is
recommended to leave this value set to ‘auto’ unless there is an explicit need to change it.
Rx Mute – The number of milliseconds to mute the receiver after transmitting data.
Receive muting might be required when you configure the radio as a full-duplex polling
remote communicating through a repeater. It prevents the radio from hearing its own
transmissions ('echoes') from the repeater, which might cause software application errors.
Rx Timeout Enable – When enabled, the radio will alarm if nothing has been received
over-the-air in 'Rx Timeout Delay' minutes. This can used to detect if the receiver has
failed, or if there has been a failure with the antenna.
Rx Timeout Delay – When ‘Rx Timeout’ is enabled, this is the number of minutes to wait
for a received signal before raising an alarm.
Legacy Packet Compatibility – When the radio-mode is configured for packet-with-mac,
enabling this option will cause the radio to operate in a legacy packet mode. This is not
full packet mode as found on SD radios, as there is no support for listen-before-talk.
Modem Receive Tolerance – Changes the receive tolerance of the modem. This value
should always be set to normal unless instructed to change it by GE MDS technical
support for specific applications.
Modem Transmit Tolerance – Changes the transmit tolerance of the modem. This value
should always be set to normal unless instructed to change it by GE MDS technical
support for specific applications.
Data Device Mode (x710 mode only) – This value controls the device behavior of the
radio when operating in x710 mode. In DCE mode, CTS will go high following RTS,
subject to the CTS programmable delay time. CTS KEY mode, the unit is assumed to be
controlling another radio. The radio will still key based on the RTS line, but the CTS line
is used as a key-line control for an external radio. CTS is asserted following the receipt of
RF data, but not until after the CTS programmable time has expired. (This gives the other
radio time to key.)
CTS Hold Time (x710 mode only) – Used in CTS KEY mode, this command sets the
amount of time in milliseconds that CTS remains present after transmission of the last
character out the RXD pin of the DATA port. This 'hold time' can be used to prevent
squelch tail data corruption when communicating with other radios.
RSSI out Enabled – When enabled, the current RSSI value will be available as a DC
voltage level on the RSSI out pin of the alarm/relay module. NOTE: This feature requires
SD NICs that are capable of generating an output voltage based on RSSI. If you attempt to
enable this feature on hardware that does not support it, you will receive an error message
preventing you from committing the changes.
RSSI out 0-Point – When RSSI out is enabled, this is the RSSI level (in dBm) that will
result in an output voltage of 0 mV
RSSI out mV per dBm – When RSSI out is enabled, this is the voltage (in mV) that will
be produced for each dBm of signal strength above the level specified in rssi-out-0-point.
e.g. Given a zero point of -120dBm, and a mv-per-dbm value of 50mV, an RSSI of -
84dBm would result in an output of 1800mV.
60 MDS™ Master Station MDS 05-6399A01, Rev. F

Audio

Audio settings are only available for configuration when the radio is configured to operate in x710 compatibility mode.
Audio Enabled – If enabled, the radio’s transmit functionality will switch to analog
whenever PTT is asserted.
Rx Level – Receive audio output level to modem (dBm). Received signal at the peak
deviation will be scaled to the specified value. Valid range is (-20 0).
Tx Level Auto – Automatically adjust transmit audio input level from Modem.
Tx Level – Transmit audio input level from modem (dBm). A transmit input signal of the
specified value will translate into the specified peak deviation for transmit. Valid range is
(-20 0).
Emphasis – When enabled, pre-emphasis is applied on the transmitter and de-emphasis is
applied on the receiver. This setting is typically used in operation with voice radios.
Squelch – When set to auto, the transceiver will use its internal squelch to enable
transmission of audio signals. When set to bypassed, the transceiver will transmit all audio
signals regardless of level.
Vox Enabled – Enables or disables the integrated VOX threshold circuit.
Vox Threshold – The audio interface on the Master Station incorporates an integrated
VOX circuit to sample the voltage produced by a connected audio device. When the
voltage exceeds a user-defined threshold, Push to Talk (PTT) is activated, resulting in the
transmitter being enabled. The VOX circuit detects a voltage in the range of 0-2 Volts. A
single number in the range of 0-15 is used to describe the desired threshold level. For
example a value of 7 is approximately 1 volt.
MDS 05-6399A01, Rev. F MDS™ Master Station 61
Enabled Alarms
This configuration section controls which of the various alarms that can be generated on the SD NIC will be propagated up to the platform manager for system logging. All alarms default to being enabled, and should remain enabled unless there is an explicit need to disable one.
RTU Simulator
The unit’s built-in RTU simulator generates random data similar to what would be supplied by an external RTU connected to the radio. It is useful for system testing within the radio network by providing realistic data to pass over the radio channel.
RTU Enabled – Enable the built-in RTU simulator.
RTU Number – The RTU number the simulator will respond to requests for.
Remote SD Reprogramming
This section contains various parameters for the broadcasting of new firmware to remote SD radios. Please see section Remote SD Reprogramming on page 65.

Actions

Force Alarm
From the Force Alarm menu, you can force the SD radio interface cards to enter a test alarm state. To activate an alarm, select which radio slot to alarm, and click the Perform action button. An “Alarm Test” entry will be created in the Event Log and the external alarm output status is changed. This can be useful when testing event logging and propagation across a network, or when testing equipment connected to the alarm output contacts on the Master Station. When enabled, the alarm will assert for 30 seconds, and then deactivate. If active, it can be manually deactivated prior to timeout by deselecting the slot number of the radio and clicking the Perform action button again.
62 MDS™ Master Station MDS 05-6399A01, Rev. F
Link Test
The primary use of the Link Test is to verify that a specific radio's settings are consistent with the initiator including: Assigned frequency, unit number setting, encryption (if enabled), etc. Also collected at the same time is an indication of link quality. All radios are always ready to respond to a Link Test message. Only the initiating radio requires configuration when using the Link Test screen and it is only available when operating in Packet w/MAC mode. A summary of data statistics is displayed on the right side of the screen, including transmit/receive packet counts, total bits, and total number of bit errors.
Destination Address – The unit address of the other radio being tested.
Count – The number of times for the message to be sent across the radio link.
Timeout – The time (in milliseconds) that will result in a timeout if no response is
received within that period.
MDS 05-6399A01, Rev. F MDS™ Master Station 63
Perform Failover
If the Master Station is equipped with redundant SD radios, the active radio can be manually toggled by selecting the “Perform action” button.
The manual toggle-switch on the alarm/relay board must be in the ‘Automatic’ position for this operation to succeed. The toggle-switch will override all software-based control of which radio is active.
Remote Management Command
The Master Station has the ability to broadcast management commands to remote SD radios in the network. These commands are sent to all connected remote radios, and hence should only be used for making network-wide changes.
The following action can be specified:
Reboot – All remote radios will reboot to the currently active firmware image.
Set Radio Mode – Change the radio mode of remote radios (x710/transparent/packet-
with-MAC)
Set Frequencies – Set the receive and transmit frequencies of remote radios.
Set Modem Type – Change the configured modem of remote radios.
Set Transmit Tolerance – Change the configured transmit tolerance of remote radios.
Set System ID – Change the configured system ID of the remote radios.
Enable Bridge – Enable or disable Ethernet bridging on remote radios.
Enable Encryption – Enable or disable OTA encryption on remote radios.
Set Payload Encryption Phrase – Change the payload encryption phrase on remote
radios.
Set Dlink Encryption Phrase – Change the Dlink encryption phrase on remote radios.
(Only used in transparent mode)
Set SCD – Change the Soft Carrier Dekey value on the remote radios.
64 MDS™ Master Station MDS 05-6399A01, Rev. F
Repeater Network Change – Change remote parameters that may need to be configured
when running in a network which uses a MDS Master Station as a repeater.
Generic Dlink Message – Broadcast a custom Dlink command to all units on the system.
Arguments include the Dlink register to write to (in hex, no leading ‘0x’), and the DLink
value to write (in hex, no leading ‘0x’). The hex argument values must be full octects (e.g.
‘0F’ instead of ‘F’.
With the exception of the reboot command, these actions will cause permanent loss in connectivity to the Master Station until the corresponding configuration changes are made to the Master Station itself.
Remote SD Firmware
Please see section “Remote SD Reprogrammingbelow.
RF Key Test
Using the RF Key Test action, the active radio can be manually keyed (transmitter enabled) or de-keyed (transmitter disabled). This may be useful when diagnosing signal-strength on a remote receiver.
Spectrum Analyzer
A unique feature of the transceiver is the ability to view the RF spectrum above and below the operating frequency using its built-in Spectrum Graph. Often, this can assist in diagnosing the cause of interference, or to view other signals near your operating frequency. To use the Spectrum Graph, you must first specify a center frequency and a scan width. The center frequency is the frequency that you wish the spectrum display to be centered on. The span frequency defines the width of the overall spectrum to be examined. Once the correct values have been entered, switch it on by sliding the on/off switch. The graph will automatically refresh itself every 5 seconds. To stop scanning, turn the on/off switch off.
MDS 05-6399A01, Rev. F MDS™ Master Station 65

Remote SD Reprogramming

OTA Reprogramming Overview
This feature is for reprogramming SD remote radios only. This will not reprogram other Master Stations on the network.
The DLink “Root” is the central location from which polling originates. Other locations in the network should be designated as “Nodes” which are the receiving stations. Over-the-air firmware upgrades should always be initiated from the Root. This ensures that all radios in the network will be properly updated. The Master Station broadcasts a series of messages to one or more remote nodes to accomplish the reprogramming process. The “broadcast” method is used to program the greatest number of radios in the shortest amount of time; however, the Master Station remains unaware of the number or success of downstream radios participating in reprogramming. During reprogramming, the status of the reprogramming will be available on all the radios participating in the process. Because the initiator is “broadcast-only” this status can only indicate progress toward sending out of all of the messages. On the nodes, the progress toward completion of reception of reprogramming information is indicated. Receiving stations can automatically reboot to the new image after successful reprogramming. Alternatively, there is an OTA reboot command that can be broadcast from the Master Station to all receiving stations. This last option instructs the receivers to reboot to a specific firmware revision if available, and not already running at that revision. Reprogramming Parameters: The setting for over-the-air reprogramming are found under the “Advanced Config” tab on the web UI.
66 MDS™ Master Station MDS 05-6399A01, Rev. F
Channel Usage – Set to either Intrusive or Passive as desired.
- Passive (Non-intrusive) operation “piggy-backs” reprogramming data onto
normal payload data streams, thus allowing payload data to continue uninterrupted, but will be slower than intrusive operation. This mode requires payload data to be sent so that the reprogramming data can be carried. See Table 5-3 for reprogramming times.
- Intrusive operation means that the payload application data will be interrupted
while programming data is sent over the air. This is the fastest method of programming radios over the air, but it comes at the cost of interruptions in the primary use of the radio network. For best results, data polling should be stopped during Intrusive Reprogramming. See Table 5-4 for reprogramming times.
Block Size – Sets the overall block size (in bytes) of each data packet. Default setting is
512.
Auto-Reboot – When enabled, the remote radios will automatically reboot after a
firmware image upgrade. If disabled, the newly loaded image will not become valid until
the remote radio is rebooted manually.
Packet Size – Specifies the size of the reprogramming data packets. Default size is 40.
Retry Count – Specifies the number of times each transmission is repeated. Default
setting is 3. Decreasing this value will decrease reprogramming times, but increase the
chance of a remote radio not properly receiving a packet.
Download Delay – Introduce a time delay before reprogramming begins. Typically, it is
set to Short, but may be increased incrementally by selecting one of the extended delay
times from the drop-down box (Short, Medium, Long, None)
Table 5-3. Approximate Reprogramming Times - Passive Mode
MDS 05-6399A01, Rev. F MDS™ Master Station 67
Modem Speed (bps)
Approximate Time Required
4800
6 hours
9600
1 hour, 30 minutes
19200
1 hour, 30 minutes
Radio assumptions: Signal strength -85 dBm or stronger, Packet Size: 40, Block Size: 512, Retry: 3, Download Delay: Short.
Polling assumptions: Serial polling with 1-second poll time, sending random data at 50­100 bytes. Slower polling times will significantly increase completion time.
Table 5-4. Approximate Reprogramming Times - Intrusive Mode
Modem Speed (bps)
Approximate Time Required
4800
1 hour, 30 minutes
9600
30-45 minutes
19200
20-25 minutes
Radio assumptions: Signal strength -85 dBm or stronger, Packet Size: 40, Block Size: 512, Retry: 3, Download Delay: Short
Polling assumptions: Polling should be temporarily suspended while OTA reprogramming is active.
Start Reprogramming
When ready to reprogram the SD firmware, click the Start Reprogramming action.
File Source – There are many file transfer protocols supported, select Local File to upload
directly from your browser, or HTTP / FTP / SFTP / TFTP to have the MDS Master
Station retrieve the file from a remote server.
Local File (Browser Upload) – Click the “Select File” to choose a file, and press “Begin
Reprogramming”
URL (HTTP only) – Enter a valid URL (e.g http://192.168.1.1/file.mpk) pointing to the
firmware.
Server Address (All) – Use this field to enter a valid IP address for the host computer
(where file to be transferred resides).
File Path (TFTP/SFTP/FTP) – This field is used to enter the exact name of the file and
path to be imported.
Block Size (TFTP) – The TFTP block size to use when transferring the file. Default is
1024.
68 MDS™ Master Station MDS 05-6399A01, Rev. F
Port (TFTP) – The TCP port that the TFTP server is operating on.
User Name (SFTP/FTP) – The user to connect to the SFTP/FTP server as.
Password (SFTP/FTP) – The password for the SFTP/FTP server.
Control Port (SFTP/FTP) – The TCP port that the SFTP/FTP server is operating on.
Default is 22 for SFTP and 21 for FTP.
Data Port (FTP) – The TCP port that the FTP server uses for data connections. Default is
20.
Timeout (All) – Determines the amount of time (in seconds) that the radio should wait for
server to respond. The default setting is 30 seconds and will not normally require any
change. When the above fields have been set and you are ready to load a new file, click the Begin Reprogramming button to begin reprogramming. To view the current status of the remote reprogramming operation, navigate to the sdms interface status page.
Cancel Reprogramming
During the reprogramming operation the user has the ability to cancel reprogramming at any time either on the Master Station, which will affect all radios, or on individual receiving stations. Note that cancelling reprogramming at the Master Station results in all radios in the network having only one (instead of two) applications programmed in their image banks. That is, the
“inactive” image (which was only partially upgraded) will be corrupt and unusable until
reprogrammed at a later time.
Reprogramming Status
Once reprogramming has begun, the current reprogramming status will appear beneath the “Cancel Reprogramming” button.
MDS 05-6399A01, Rev. F MDS™ Master Station 69

Monitoring

Statistics
Interfaces  sdms  Status  Statistics
Discontinuity Time – The time on the most recent occasion at which any one or more of
this interface’s counters suffered a discontinuity or interruption of service.
In Octets – The total number of octets received on the interface, including framing
characters.
In Unicast Pkts – The number of packets, delivered by this sub-layer to a higher (sub-
)layer, which were not addressed to a multicast or broadcast address at this sub-layer.
In Multicast Pkts – The number of packets, delivered by this sub-layer to a higher (sub-
)layer, which were addressed to a multicast address at this sub-layer.
In Discards – The number of inbound packets which were chosen to be discard even
though no errors had been detected to prevent their being deliverable to a higher-layer
protocol. One possible reason for discarding such a packet could be to free up buffer
space.
In Errors – For packet-oriented interfaces, the number of inbound packets that contained
errors preventing them from being deliverable to a higher-layer protocol.
Out Octets – The total number of octets transmitted out of the interface, including
framing characters.
Out Unicast Pkts – The total number of packets that higher-level protocols requested be
transmitted and which were not addressed to a multicast or broadcast address at this sub-
layer, including those that were discarded or not sent.
Out Discards – The number of outbound packets which were chosen to be discarded even
though no errors had been detected to prevent their being transmitted.
Out Errors – For packet-oriented interfaces, the number of outbound packets that could
not be transmitted because of errors.
70 MDS™ Master Station MDS 05-6399A01, Rev. F

Performance

Interfaces  sdms  Status  Performance
Measured RF Power – Read-only indication of the measured RF output power (in dBm).
Signal to Noise (SNR) – Read-only indication of the signal-to-noise ratio of the received
signal.
RSSI – Read-only indication of the measured received signal strength (in dBm).
IPv4 / IPv6
MDS 05-6399A01, Rev. F MDS™ Master Station 71

5.10 SD-x/0/0 Interfaces

Configuration for each SD Radio Modules is done via the SDMS interface. Each individual interface provides statistics for serial, IP payload and MAC that could be helpful in a debugging situation.

General

Interfaces  sd-x/0/0  Status / General
This screen is read-only and displays the status of the SD NIC interface.

Statistics

Interfaces  sd-x/0/0  Status / Statistics
Sd Statistics
This section will contain statistics on the MAC, COM Ports, and IP Payload (1-3).
Discontinuity Time - The time on the most recent occasion at which any one or more of
this interface’s counters suffered a discontinuity or interruption of service.
72 MDS™ Master Station MDS 05-6399A01, Rev. F
Com 1 Tx Bytes – The total number of transmitted bytes on the COM1 port.
Com 1 Rx Bytes – The total number of received bytes on the COM1 port.
Com 2 Tx Bytes – The total number of transmitted bytes on the COM2 port.
Com 2 Rx Bytes – The total number of received bytes on the COM2 port.
Pmux Tx Packets – The total number of data packets transmitted.
Pmux Rx Packets – The total number of data packets received.
Com 1 Tx Packets – The total number of transmitted packets on the COM1 port.
Com 2 Tx Packets – The total number of transmitted packets on the COM2 port.
Eth Tx Packets – The total number of transmitted packets on the Ethernet port.
IP Payload (1, 2 or 3) Statistics
Tx Packets – Total number of transmitted packets.
Rx Eth Bytes – Total number of received bytes on the Ethernet.
Rx Eth Packets – Total number of received packets on the Ethernet.
Tx Eth Bytes – Total number of transmitted bytes on the Ethernet.
Tx Eth Packets – Total number of transmitted packets on the Ethernet.
Rx Radio Bytes – Total number of received bytes through the radio.
Tx Radio Bytes – Total number of transmitted bytes through the radio.
MDS 05-6399A01, Rev. F MDS™ Master Station 73
Tx Radio Packets – Total number of transmitted packets through the radio.
Rx Radio Failed Bytes – Total number of received bytes failed through the radio.
Rx Radio Failed Packets – Total number of received packets failed through the radio.
Tx Eth Failed Bytes – Total number of transmitted bytes failed on the Ethernet.
Tx Eth Failed Packets – Total number of transmitted packets failed on the Ethernet.
TCP Keepalive Timeouts – Total number of TCP Keepalive Timeouts by the radio.
MAC Statistics
MAC Tx Frames – Total number of transmitted frames on the MAC.
MAC Rx Frames – Total number of received frames on the MAC.
MAC Checksum Fails – Total number of checksum failures on the MAC.
MAC Tx Data Frames – Total number of transmitted data frames on the MAC.
MAC Tx Contention Frames – Total number of transmitted contention frames on the
MAC.
MAC Tx Contention Grants – Total number of transmitted contention grants on the
MAC.
MAC Tx Contention Requests – Total number of transmitted contention requests on the
MAC.
MAC Retries – Total number of retires on the MAC.
74 MDS™ Master Station MDS 05-6399A01, Rev. F
MAC Acknowledgements – Total number of MAC frames acknowledged by the access
point. (when operating as a remote)
MAC TTL Expirations – Total number of frames dropped due to expired time-to-live
counters.

5.11 LNMS interface

Understanding

Licensed Narrowband Modules are available in various global frequencies. The term “LN” is used to denote all licensed narrowband modules within the Orbit family. Specific identification, such as “LN400,” is used when necessary to reference band-specific hardware. The LN NIC modules are reliable point-to-multipoint, wireless data transmission products. An LN NIC can operate as an Access Point or Remote. Licensed Narrowband modules provide robust long-distance communication in channel bandwidth sizes of 6.25KHz, 12.5KHz, and 25KHz. Depending on bandwidth, raw data rates range from 20kbps to 120kbps. The radio is suitable to interface both Ethernet and Serial controllers such as PLCs, RTUs and SCADA systems while offering greater throughput then traditional FSK solutions. The module utilizes QAM modulation, a highly efficient PA, and a direct conversion receiver to provide dependable wireless communications. An advanced Media Access Control (MAC) provides advanced interference avoidance, error detection, retransmission, auto repeat, and guaranteed collision free data. 10-Watts of peak power and dynamic FEC extend coverage to up to 50 miles.
The specifications for the LN400 NIC module:
Frequency Range(s): 406-470 MHz, 330-406 MHz FCC Part 90 (private land mobile radio services) FCC ID: E5MDS-LN400 ICID: 101D-LN400
The specifications for the LN700 NIC module:
Frequency Range(s): 757-788 MHz FCC Part 90 (private land mobile radio services) FCC ID: E5MDS-LN700 ICID: n/a
The specifications for the LN900 NIC module:
Frequency Range: 896-960 MHz FCC Part 90 (private land mobile radio services) & Part 101 FCC ID: E5MDS-LN900 ICID: 101D-LN900
MDS 05-6399A01, Rev. F MDS™ Master Station 75
The general specifications for all LN NIC modules are:
Peak Power Output: 20 dBm to 40 dBm peak power in 1.0 dBm steps (DEFAULT = 40 dBm) Output Impedance: 50 Ohms Antenna Connector: TNC female Modulation Type: QPSK, 16QAM, 64QAM FEC: Convolutional and Reed Solomon Data Rates: 20kbps - 120kbps
Multiple modulation rate / bandwidth combinations are provided; as seen in Table 5-5.
Table 5-5. Modulation and Bandwidth for LN radios
RF
Channel
Bandwidth
Modem Symbol
rate
QPSK
(x2)
OTA rate
16QAM
(x4)
OTA rate
64QAM
(x6)
OTA rate
6.25 KHz
4800 sps
9600 bps
19200 bps
28800 bps
12.5 KHz
9600 sps
19200 bps
38400 bps
57600 bps
12.5 KHz
10000 sps
20000 bps
40000 bps
60000 bps
25.0KHz
16000 sps
32000 bps
64000 bps
96000 bps
25.0KHz
20000 sps
40000 bps
80000 bps
120000 bps
NOTE The only required steps for basic configuration are: Program transmit and receive frequencies
per user licensing; program a network name in all units; establish one unit as the AP
Minimal configuration is necessary but several advanced tuning facilities are provided. By default the radio ships from the factory with a 12.5KHz bandwidth and 10k-symbol/sec data rate. Modem operation is configured for Adaptive Modulation with FEC disabled. Transmit and Receive frequencies are unprogrammed and left to field installation personnel to prevent inadvertent operation on the wrong channel. For the advanced user, the module supports configuring more items including:
Data Retries - Number of times to retry unicast data before declaring NACK. Power – RF output power control. ARP Cache – Feature that limits over-the-air ARP traffic Data and Header Compression – facilities to use LZO data compression for payload and robust
header compression to reduce packet overhead
FEC – facility to selectively enable Forward Error Correction trading off speed and robustness Allow Retransmit – facility to enable peer-to-peer traffic
In general, it is recommended that users start with the simplest configuration and then make parameter changes as necessary to meet specific needs.
NOTE To meet country specific regulatory requirements, some parameter restrictions may be
configured by the factory. These settings can NOT be changed or modified by the user.
See Table 6-14. LN Interface LED Descriptions for details on how to interperate the LEDs on an LN radio.
76 MDS™ Master Station MDS 05-6399A01, Rev. F
Important Notes and Information Regarding EVM
EVM (error vector magnitude) is dependent on the modulation format and should be used as a relative measurement of the link quality. A low EVM value indicates a better link quality than a high value. Algorithmically, using QAM modulation, the transceiver calculates the value by measuring the sample points of each "bit" and comparing it with the expected constellation based on the modem type.
- EVM is a metric of the quality of the received signal. It is a dynamic value that is computed
only when data is received on the RF interface, and should be refreshed accordingly.
- Unlike RSSI which simply measures signal strength, EVM is a measurement of the
"correctness" of this signal. (This means how easily the received signal can be correctly demodulated.)
- In general the lower the EVM the better the quality. A strong link will typically show an EVM
below 5.
Adaptive Modulation
The adaptive modulation mode (modulation automatic) allows directed traffic to adjust which modem is used on a per-transmission basis. Adaptive modulation works in both upstream and downstream mode. The mode selection varies between QPSK, 16QAM, and 64QAM. A signal metric score is used to decide which modem selection to use. The score is determined based on signal strength and packets received. Advanced configuration can be used to provide some control over the adaptive modulation thresholds. The primary use case for this feature is if an AP has some remotes that are close to the AP and could support a higher data rate and some farther away (or obstructed) that can only support a lower data rate. This mode allows the close remotes to take advantage of the higher data rate for the directed messages, when otherwise the whole network would have had to be run at the lower data rate. Note that broadcast or multicast data must always be transmitted at the lowest rate. We recommend keeping adaptive modulation set for most installations.
Security
Setting the security mode to EAP or PSK will enable device authentication. When enabled, the remotes will authenticate with the AP (PSK) or a backend RADIUS server (EAP) before they are allowed to pass data on the network. The authentication protocol is compliant with IEEE 802.1X. If device authentication is enabled, over the air data encryption can also be enabled. This ensures all over the air traffic is protected. When encryption is enabled, the device must occasionally rotate the encryption keys. This rotation is logged in the event log with event type nx_auth. These events can be suppressed in the event log configuration to prevent them from filling the event log. See the MCR Technical Manual for instruction on controlling the event log.
MDS 05-6399A01, Rev. F MDS™ Master Station 77
Configuring
Basic configuration with defaults
Navigate to: Interfaces / lnms ---> Basic Config / LN Radio
Figure 5-5. Licensed Narrowband (LN) Configuration Settings
Members – The ln-nic interfaces that are used for this configuration
Device Mode - Sets the role the radio will assume in the network.
- Remote (DEFAULT)
- AP
Network Name - The name of the network. Used to control what networks the radio connects
to. Valid values: 1 to 31 letters (DEFAULT is mds_ln). The network name string is used to identify the logical network that the device should join. If the network name does not match, the device will log an event to identify network name collisions.
Data Compression – Over the air compression
- lzo - Compresses the over the air traffic with the LZO algorithm (DEFAULT)
- none - No data compression
Header Compression – Enabled by DEFAULT. Enable/disable over the air robust header
compression. This feature compresses IP headers to improve system performance, and is most
78 MDS™ Master Station MDS 05-6399A01, Rev. F
useful in applications that rely on IP packets with small payloads, such as terminal server operations or MODBUS polling. This setting must match on each radio (Remote and AP).
Power - The transmit power of the radio: Valid values: 20 - 40 dBm – DEFAULT is 40dBm
TX Frequency – The frequency at which the radio transmits.
RX Frequency – The frequency at which the radio receives.
Channel - Controls the channel bandwidth and symbol rate of the radio.
- 6.25 kHz-4.8 ksps - Channel width 6.25 kHz, symbol rate of 4.8 ksps
- 12.5 kHz-9.6 ksps - Channel width 12.5 kHz, symbol rate of 9.6 kbps
(DEFAULT)
- 12.5 kHz-10 ksps - Channel width 12.5 kHz, symbol rate of 10 kbps
- 25 kHz-16 ksps - Channel width 25 kHz, symbol rate of 16 kbps
- 25 kHz-20 ksps - Channel width 25 kHz, symbol rate of 20 kbps
NOTE Some channel configurations may not be available for use because of country restrictions.
Modulation – Sets the radio’s modulation. You may select automatic (adaptive modulation),
or choose from three fixed modulations.
- Adaptive modulation (DEFAULT)
- QPSK
- 16QAM
- 64QAM
Automatic modulation adaptively selects which modem (QPSK, 16QAM, or 64QAM) is used on a per-transmission basis. This is useful in networks with some remotes close to the Access Point, and others farther away or obstructed. This mode allows the close remotes to take advantage of the higher data rate for the directed messages, while the remotes use a more conservative modulation. Radios with fixed modulation settings will operate only at the modulation that you specify. If the specified modulation is higher than the connection can support, no traffic will flow. If the connection can support a higher modulation than the selected modulation, the radio will not take advantage of this and will continue to use the fixed modulation. We recommend that Adaptive Modulation be used in all cases other
than bench tests.
Theoretical throughput is based on modulation and channel settings. Please refer to Table 5-5 above.
FEC -- Forward Error Correction is useful in controlling errors in weak connections. FEC
encodes data in a redundant fashion to allow data correction in a noisy or weak connection without the additional overhead of retransmission.
- Disabled (DEFAULT). No Forward Error Correction will be used. This option provides the
highest throughput and standard sensitivity, and is suitable for strong connections.
- Low Gain – Provides better sensitivity, while still offering good throughput.
- Adaptive – Provides the best sensitivity and standard throughput. Adaptive on a per-packet basis.
NOTE It is critical to have FEC set identically on the AP and all Remotes.
MDS 05-6399A01, Rev. F MDS™ Master Station 79
Figure 5-6. Licensed Narrowband (LN) PSK Security Settings
Figure 5-7. Licensed Narrowband (LN) EAP on remote Security Settings
Figure 5-8. Licensed Narrowband (LN) EAP on an access point Security Settings
Security Mode - The type of over the air authentication to perform
- none - Provide no device authentication or data privacy (DEFAULT)
- psk - Use pre-shared key authentication protocol
- eap - Use Encapsulated Authentication Protocol - will change the fields displayed and give the
user the ability to enter radius info on the AP and certificate info on the remote.
Encryption - The type of over the air encryption to perform
- none - No data privacy (DEFAULT)
- aes128-ccm - Protect data with 128-bit AES encryption using CCM mode
- aes256-ccm - Protect data with 256-bit AES encryption using CCM mode
Passphrase - The passphrase used in PSK mode, 8 to 64 letters. (DEFAULT=blank)
Certificate ID, Key ID, CA Certificate ID (Remote EAP mode only) – Reference to the
remotes certificate material loaded through the Certificate Management side menu.
Radius Server (AP EAP mode only) – A reference to the RADIUS server configuration
configured through the System – RADIUS side menu item.
80 MDS™ Master Station MDS 05-6399A01, Rev. F
Rekey Interval (AP only) – The session key for an active secure link changes at a regular
basis. You may increase the length of the rekey interval in order to reduce overhead caused by the rekeying communications between radios on a narrowband channel. Valid values:
- 0 – Rekeying will not be time-based, but will instead occur every one million packets.
- 30-525600 minutes, DEFAULT 180.
NOTE Remember to click on the Save button when finished.

Advanced Configuration

Figure 5-9. Licensed Narrowband AP Advanced Settings
Figure 5-10 Licensed Narrowband (LN) Remote Advanced Settings
The Advanced Setting menu appears slightly different on APs than on Remotes.
Data Retries - Number of times to retry unicast data before declaring failure. Valid values:
015, DEFAULT = 3.
Packet TTL (Time-to-Live) – Length of time, in milliseconds, of inactivity of all over-the-air
traffic before registering a disconnection. The radio will then attempt to reconnect to the network. Valid values: 100 to 65535 ms, DEFAULT = 2000 (2 seconds).
MDS 05-6399A01, Rev. F MDS™ Master Station 81
Remote Age Time – Length of time, in seconds, of inactivity of a remote before it is
disconnected. Valid values: 180-4294967295 seconds, DEFAULT = 600 (10 minutes).
Endpoint Age Time (AP only) - Length of time in seconds of inactivity on an endpoint before
it is removed from the endpoint database. Range of 0 to 4294967295 seconds. DEFAULT = 300 (5 minutes).
Allow Retransmit (AP only) – All traffic from the remotes is sent to the AP. When enabled
the AP will retransmit traffic from one remote to another based on the MAC address. It will also resend any remotes broadcast traffic to all other remotes. Disabled by DEFAULT.
NIC ID (Remote only) – ADVANCED SETTING - DO NOT CHANGE - Manually
overrides the NIC identifier.
ARP Cache – Enabled by DEFAULT. When enabled, the radio will respond to ARP requests
intended for other network devices with known addresses. It will not forward the ARP to the intended device. This is similar to ARP proxy.
QAM 16 Threshold – When the radio is using automatic modulation, it will automatically
switch to QAM 16 modulation when the averaged calculated RSSI value drops below this value. Valid values: -100 to 0 dBm, DEFAULT = -85 dBm. If you set the value to 0, this modulation is disabled.
QAM 64 Threshold – When the radio is using automatic modulation, it will automatically
switch to QAM 64 modulation when the averaged calculated RSSI value drops below this value. Valid values: -90 to 0 dBm, DEFAULT = -70 dBm. If you set the value to 0, this modulation is disabled.

Monitoring

General Interface information: Interfaces / lnms  Status / General
Figure 5-11. Licensed Narrowband (LN) AP Status
Type - The type of the interface. Licensed Narrowband radios appear as “ln.”
Admin Status - The desired state of the interface.
Oper Status - The current operational state of the interface.
If Index - The index value for this interface in the Orbit’s interface table. Valid values
are: 1-2147483647
Phys Address- The interface's address at its protocol sub-layer. For a LN module, this object
normally contains a MAC address.
82 MDS™ Master Station MDS 05-6399A01, Rev. F
Statistics - A collection of interface-related statistics objects.
Figure 5-12. Licensed Narrowband (LN) Statistics
Discontinuity Time - The time on the most recent occasion at which one or more of this
interface's counters suffered a discontinuity.
In Octets - The total number of octets received on the interface, including framing characters.
In Unicast Pkts - The number of packets, delivered by this sub-layer to a higher (sub-)layer,
which were not addressed to a multicast or broadcast address at this sub-layer.
In Multicast Pkts - The number of packets, delivered by this sub-layer to a higher (sub-)layer,
which were addressed to a multicast address at this sub-layer.
In Discards - The number of inbound packets which were chosen to be discarded even though
no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.
In Errors - For packet-oriented interfaces, the number of inbound packets that contained
errors preventing them from being deliverable to a higher-layer protocol.
Out Octets - The total number of octets transmitted out of the interface, including framing
characters.
Out Unicast Pkts - The total number of packets that higher-level protocols requested be
transmitted, and which were not addressed to a multicast or broadcast address at this sub-layer, including those that were discarded or not sent.
Out Discards - The number of outbound packets which were chosen to be discarded even
though no errors had been detected to prevent their being transmitted.
Out Errors - For packet-oriented interfaces, the number of outbound packets that could not be
transmitted because of errors.
Ln Radio Status Monitoring:
Interfaces / lnms  Status / Ln Radio
MDS 05-6399A01, Rev. F MDS™ Master Station 83
Figure 5-13. Licensed Narrowband (LN) Status
The following status items appear on both APs and Remotes (unless stated otherwise)
Init Status - State of the NIC Initialization
- Off - Not operating
- Initializing - Powering on the NIC
- Discovering - Determining the NIC address
- Reprogramming - Programming the NIC firmware
- Configuring - Configuring the NIC
- Complete - Initialization complete
Current Device Mode – Read-only display of the active mode the lnms is operating.
Alarms - The current NIC alarms:
- synthesizer-out-of-lock: Synthesizer is out of lock. Call GE MDS tech support for assistance.
- radio-not-calibrated: Radio was not calibrated. Call GE MDS tech support for assistance.
- internal-temp: The radio’s internal temperature exceeds the operating threshold.
Firmware Revision - NIC Firmware Revision.
Temperature - The transceiver temperature in degrees C.
Modem Tx Success – Number of packets successfully transmitted by the modem.
Modem Tx Error – Number of transmit errors reported by the modem.
Modem Rx Success – Number of packets successfully received by the modem.
Modem Rx Error – Number of receive errors reported by the modem.
MAC Tx Success - Successful transmissions.
MAC Tx Queue Full - Failed transmissions, MAC queue full.
MAC Tx Error - Packets dropped for other reasons.
General
Modem Stats
MAC Stats
84 MDS™ Master Station MDS 05-6399A01, Rev. F
MAC Tx Retry - Re-transmission count due to previously unsuccessful transmission.
MAC Rx Success - Valid packet received.
MAC Rx Error – Received packets dropped due to error.
Last RSSI – The RSSI measured at the time of the last received packet.
Last Error Vector Magnitude The EVM measured at the time of the last received packet. For more information, refer to See Table 6-14. LN Interface LED Descriptions for details on how to interperate the LEDs on an LN radio. Important Notes and Information Regarding EVM
Last Modulation – The modulation measured at the time of the last received packet.
Rate – The calculated over the air rate from Table 5-5.
Figure 5-14 Licensed Narrowband (LN) Hardware Info
Information about the Licensed Narrowband NIC’s hardware is also displayed on the LN
Radio’s Statistics menu. This information may be helpful when calling technical support.
Connections Status (AP Only)
In AP mode the “Connected Remotes” and “Endpoints” information will be displayed in addition
to the Active Channel.
Figure 5-15. Licensed Narrowband (LN) AP Connection Status
Last RX Packet
Hardware Info
MDS 05-6399A01, Rev. F MDS™ Master Station 85
Remote’s AP Info (Remote Only):
Figure 5-16. Licensed Narrowband (LN) Remotes AP Information
AP Address - MAC address of access point this device is linked to.
IP Address - IP address of access point this device is linked to.
Connected Time - Time elapsed in seconds since link established. After 4294967295 seconds,
the value displayed rolls over to 0.
RSSI - The RSSI measured at the time of the last received packet. If using this reading to align
an antenna or gather link status information, we recommend setting the page refresh to 3 seconds.
EVM - The Error Vector Magnitude measured at the time of the last received packet. For
more information, refer to See Table 6-14. LN Interface LED Descriptions for details on how to interperate the LEDs on an LN radio.
Important Notes and Information Regarding EVM
Rx Modulation - The modulation measured at the time of the last received packet.
Test Mode
Interfaces / lnms  Actions
Test Mode provides a way to place the transmitter on the air to check the measured RF power output, measure reflected power from an antenna system, or to provide a signal at a receiving
86 MDS™ Master Station MDS 05-6399A01, Rev. F
station so that RSSI can be checked. While in Test Mode, a radio will not operate normally and does not communicate with the narrowband network. To enter or exit Test Mode, select the desired test state from the State drop-down box and click Perform Action.
Time – The time, in minutes, to remain in test mode before automatically resuming normal
operation. We recommend that you remain in test mode 10 minutes or less.
State -
- Receive – Enter Receive mode to check the RSSI of a received signal.
- Keyed – Key the transmitter. To prevent damage to the radio, the unit will stop keying after one
minute and automatically transition to the Receive state.
- Stop – Stop all test operations and exit test mode.
Test Values
Test Mode Time – The length of time test mode has been running.
Test State – Receive, Keyed, Stop. The current test state.
Test RSSI (Receive Mode only) – The current signal RSSI.

CLI Configuration Examples

AP Mode
On the next page, the example will display how to configure the LN module as an access point with the network name of ‘MyNetwork’ and default settings. For this example we assume a transmit frequency of 451.4 MHz and a receive frequency of 456.4 MHz. Your own LN frequencies must be set according to your user license.
% set interfaces interface lnms ln-config device-mode access-point network-name MyNetwork
tx-frequency 451.4 rx-frequency 456.4 % show interfaces interface lnms ln-config | details radio-mode standard; members [ ln-1/0/0 ln-2/0/0 ]; device-mode access-point; network-name MyNetwork; data-compression lzo; header-compression true; power 40; tx-frequency 451.4; rx-frequency 456.4; channel 12.5KHz-9.6ksps; modulation automatic; fec false; security { security-mode none; encryption none; } advanced-config { data-retries 3; packet-ttl 600; remote-age-time 600; endpoint-age-time 300; allow-retransmit true;
MDS 05-6399A01, Rev. F MDS™ Master Station 87
arp-cache false; qam16-threshold -85; qam64-threshold -70; }
Security configuration
The default security mode, as shown above, is none. The following configures the LN module to use pre-shared key authentication with the passphrase 'mypassphrase' and aes256-ccm encryption.
NOTE When viewing the configuration, the passphrase that you entered is not displayed in plaintext.
This is a security measure.
% set interfaces interface lnms ln-config security encryption aes256-ccm security-mode
psk passphrase mypassphrase % show interfaces interface lnms ln-config | details radio-mode standard; device-mode access-point; network-name MyNetwork; data-compression lzo; header-compression true; power 40; tx-frequency 451.4; rx-frequency 456.4; channel 12.5KHz-9.6ksps; modulation automatic; fec false; security { security-mode psk; encryption aes256-ccm; passphrase $4$BfPtSlDWFNhtqe4ZcJTWQQ==; } advanced-config { data-retries 3; packet-ttl 600; remote-age-time 600; endpoint-age-time 300; allow-retransmit true; arp-cache false; qam16-threshold -85; qam64-threshold -70; }
The following configures the LN module to use data compression, EAP authentication and aes256-ccm encryption. The radius server used by the EAP authentication is selected from a list of configured Radius servers.
% set interfaces interface lnms ln-config security encryption aes256-ccm security-mode
eap radius-server RADIUS_SERVER % show interfaces interface lnms ln-config | details radio-mode standard; device-mode access-point; network-name MyNetwork; data-compression lzo; header-compression true;
88 MDS™ Master Station MDS 05-6399A01, Rev. F
power 40; tx-frequency 451.4; rx-frequency 456.4; channel 12.5KHz-9.6ksps; modulation automatic; fec false; security { security-mode eap; encryption aes256-ccm; radius-server RADIUS_SERVER; } advanced-config { data-retries 3; packet-ttl 600; remote-age-time 600; endpoint-age-time 300; allow-retransmit true; arp-cache false; qam16-threshold -85; qam64-threshold -70; }
Remote Mode
The following will configure the LN module as a Remote with the network name of 'MyNetwork' and default settings. For this example we assume the inverse of the AP frequency plan – a transmit frequency of 456.4 MHz and a receive frequency of 451.4 MHz. Your own LN frequencies must be set according to your user license.
% set interfaces interface lnms ln-config device-mode remote network-name MyNetwork tx-
frequency 456.4 rx-frequency 451.4 % show interfaces interface lnms ln-config | details radio-mode standard; device-mode remote; network-name MyNetwork; data-compression lzo; header-compression true; power 40; tx-frequency 456.4; rx-frequency 451.4; channel 12.5KHz-9.6ksps; modulation automatic; fec false; security { security-mode none; encryption none; } advanced-config { data-retries 3; nic-id 0; inactivity-timeout 600; remote-age-time 600; arp-cache false;
MDS 05-6399A01, Rev. F MDS™ Master Station 89
qam16-threshold -85; qam64-threshold -70; }
Security Configuration
The default security mode, as shown above, is none. The following configures the LN module to use pre-shared key authentication with the passphrase “mypassphrase” and aes256-ccm encryption.
NOTE When viewing the configuration, the passphrase that you entered is not displayed in plaintext.
This is a security measure.
% set interfaces interface lnms ln-config security encryption aes256-ccm security-mode
psk passphrase mypassphrase % show interfaces interface lnms ln-config | details radio-mode standard; device-mode remote; network-name MyNetwork; data-compression lzo; header-compression true; power 40; tx-frequency 456.4; rx-frequency 451.4;
channel 12.5KHz-9.6ksps; modulation automatic; fec false; security { security-mode psk; encryption aes256-ccm; passphrase $4$BfPtSlDWFNhtqe4ZcJTWQQ==; } advanced-config { data-retries 3; nic-id 0; inactivity-timeout 600; remote-age-time 600; arp-cache false; qam16-threshold -85; qam64-threshold -70; }
The following configures the LN module to use data compression, EAP authentication and aes128-ccm encryption. The EAP mode currently supports only EAP-TLS. This requires configuring the appropriate PKI Certificates and Keys to use in the TLS authentication. This information is selected from the PKI configuration.
% set interfaces interface lnms ln-config security encryption aes128-ccm security-mode
eap eap-mode eap-tls pki ca-cert-id CACert key-id DevicePrivKey cert-id DevicePubCert % show interfaces interface lnms ln-config | details radio-mode standard; device-mode remote; network-name MyNetwork; data-compression lzo; header-compression true;
90 MDS™ Master Station MDS 05-6399A01, Rev. F
power 40; tx-frequency 456.4; rx-frequency 451.4; channel 12.5KHz-9.6ksps; modulation automatic; fec false; security { security-mode eap; encryption aes128-ccm; eap-mode eap-tls; pki { cert-id DevicePubCert; key-id DevicePrivKey; ca-cert-id CACert; } } advanced-config { data-retries 3; nic-id 0; inactivity-timeout 600; remote-age-time 600; arp-cache false; qam16-threshold -85; qam64-threshold -70; }
Monitoring
Ensure the CLI is in operational mode.
Access Point Mode
The following shows status with two stations connected.
> show interfaces-state interface lnms ln-status ln-status init-status complete ln-status current-device-mode access-point ln-status alarms "" ln-status firmware-revision 0.2.4 ln-status temperature 45 ln-status modem-stats modem-tx-success 5401378 ln-status modem-stats modem-tx-error 0 ln-status modem-stats modem-rx-success 37645 ln-status modem-stats modem-rx-error 11 ln-status mac-stats mac-tx-success 72699 ln-status mac-stats mac-tx-queue-full 0 ln-status mac-stats mac-tx-error 0 ln-status mac-stats mac-tx-retry 132 ln-status mac-stats mac-rx-success 17952 ln-status mac-stats mac-rx-error 498 ln-status last-rx-packet last-rssi -128 ln-status last-rx-packet last-evm 255 ln-status last-rx-packet last-modulation qam64 ln-status last-rx-packet rate 96
MDS 05-6399A01, Rev. F MDS™ Master Station 91
ln-status hardware-info serial-number 2673840 ln-status hardware-info hardware-id 0 ln-status hardware-info hardware-revision 0 ln-status test test-mode-time 0 ln-status test test-state stop ln-status connected-remotes 00:06:3d:09:14:7d ip-address 10.15.65.145 time-to-live 767 link-status associated rssi -67 evm 0 rx-modulation qam64 device-stats tx-packets 730 device-stats tx-bytes 108661 device-stats rx-packets 721 device-stats rx-bytes 215575 device-stats tx-error 10 device-stats rx-error 0 device-stats tx-drop 0 device-stats rx-drop 0 nic-id 1
Remote Mode
The following shows status when connected to a configured Access Point.
> show interfaces-state interface lnms ln-status ln-status link-status associated ln-status init-status complete ln-status current-device-mode remote ln-status alarms "" ln-status firmware-revision 0.2.4 ln-status temperature 43 ln-status modem-stats modem-tx-success 33116 ln-status modem-stats modem-tx-error 0 ln-status modem-stats modem-rx-success 197463 ln-status modem-stats modem-rx-error 55283 ln-status mac-stats mac-tx-success 11424 ln-status mac-stats mac-tx-queue-full 0 ln-status mac-stats mac-tx-error 0 ln-status mac-stats mac-tx-retry 0 ln-status mac-stats mac-rx-success 13390 ln-status mac-stats mac-rx-error 1 ln-status ap-info ap-address 00:06:3d:09:0d:d8 ln-status ap-info ip-address 192.168.1.51 ln-status ap-info connected-time 174 ln-status ap-info rssi -68 ln-status ap-info evm 0 ln-status ap-info rx-modulation qpsk ln-status last-rx-packet last-rssi -68 ln-status modem-stats modem-tx-success 33116 ln-status modem-stats modem-tx-error 0 ln-status modem-stats modem-rx-success 198622 ln-status modem-stats modem-rx-error 55283
92 MDS™ Master Station MDS 05-6399A01, Rev. F
ln-status mac-stats mac-tx-success 11424 ln-status mac-stats mac-tx-queue-full 0 ln-status mac-stats mac-tx-error 0 ln-status mac-stats mac-tx-retry 0 ln-status mac-stats mac-rx-success 13390 ln-status mac-stats mac-rx-error 1 ln-status ap-info ap-address 00:06:3d:09:0d:d8 ln-status ap-info ip-address 192.168.1.51 ln-status ap-info connected-time 226 ln-status ap-info rssi -68 ln-status ap-info evm 0 ln-status ap-info rx-modulation qpsk ln-status last-rx-packet last-rssi -68 ln-status last-rx-packet last-evm 0 ln-status hardware-info serial-number 2661832 ln-status hardware-info hardware-id 0 ln-status hardware-info hardware-revision 0 ln-status test test-mode-time 0
ln-status test test-state stop
Test Mode
Ensure the CLI is in operational mode. To enter Test Mode and key the transmitter for 5 minutes:
> request interfaces-state interface lnms ln-status test-mode state keyed time 5
To enter Test Mode’s receive state for 5 minutes:
> request interfaces-state interface lnms ln-status test-mode state receive time 5
To exit Test Mode:
> request interfaces-state interface lnms ln-status test-mode state stop
To display the current test state:
> show interfaces-state interface lnms ln-status test
MDS 05-6399A01, Rev. F MDS™ Master Station 93

5.12 LN-x/0/0 interfaces

Figure 5-17 ln-x/0/0 Ln statistics
The lnms interfaces shows the active nics statistics while the ln-nic interface shows the statistics of each nic, active or not. It has the additional parameter of active nic, which indicates if this nic is active in particular. All other parameters are the same as the lnms interface.
94 MDS™ Master Station MDS 05-6399A01, Rev. F

6.0 MASTER STATION MODULES

The available modules are listed below and described in the following sections. To aid identification, most modules have their 4-digit base part number printed on the faceplate. These are the 4 numeric digits following 03- prefix.
Table 6-1. Available Modules
Identifier
Item
Description
6755
100-220V AC Power Supply Module
100-220 VAC, 50/60 Hz. 120W Max AC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDSMaster Station.
6834
Platform Manager Module
Provides management and data interface functions.
6837
Duplexers
Spare duplexer in tray wired for MDSMaster Station.
6843
+/- 12-36 V DC Power Supply Module
+/- 12-36 VDC. 10 A Max. DC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDSMaster Station.
6844
+/- 36-75 V DC Power Supply Module
+/- 36-75 VDC. 3.5 A Max DC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDSMaster Station.
6845
+/- 75-140 V DC Power Supply Module
+/- 75-140 VDC. 2 A Max DC Power Supply Module. Spare power supply can be used in either of two power supply slots of the MDSMaster Station.
6846
Narrowband Radio Module: SMD9, SDM4, LN9, LN7, or LN4
Full duplex SD-compatible radio module or LN-compatible QAM radio module
6847
Redundant Alarm/Relay Module
Active radio relay and alarm/audio interface.
6848
None-Redundant Alarm Module
Non-redundantAlarm and audio interface.
MDS 05-6399A01, Rev. F MDS™ Master Station 95

6.1 AC Power Supply Module

Figure 6-1 AC Power Supply Module
(Part No. 03-6755A02: 110/220 VAC)
Table 6-2. 6755 AC Power Supply Module Specifications
Supply Type
SMPS AC to DC
Input Voltage Range
100-264 VAC
Output
24 VDC, 4.0A
Line Frequency
50-60Hz
Power Consumption
120W, Maximum
Protection
Integrated thermal protection, short circuit protection, internal non-serviceable fuse
Ambient Temperature range
Full capacity from -30°C to +60°C. CSA certified operating range -30°C to +39°C.
Master station power supply modules are field replaceable units that can
be removed from an operating system so long as the input power source to the module being replaced has been disconnected. Refer to Section 8.4 Replacing Modules for information on removal and installation.
When installing AC Power Supply modules, torque thumbscrews to 10
in-lbs, or approximately ¼ turn past hand tight, to insure optimum heat transfer through thermal contact connector on the rear of the unit.
96 MDS™ Master Station MDS 05-6399A01, Rev. F

6.2 DC Power Supply Module

Figure 6-2. DC Power Supply Module
Including: 03-6843A01: +/- 12-36 VDC 03-6844A01: +/- 36-75 VDC 03-6845A01: +/- 75-140 VDC
Table 6-3. DC Power Supply Module (6843, 6844, 6845) Specifications:
Supply Type
SMPS DC to DC
Input Voltage Range
+/-36-75 VDC, input is isolated from ground +/-12-36 VDC, input is isolated from ground +/-75-140 VDC, input is isolated from ground
Output
24 VDC, 4.0 A
Line Frequency
DC Input only
Power Consumption
120W, Maximum
Protection
Integrated thermal protection, short circuit protection, internal fuse
Ambient Temperature range
Full capacity from -30°C to +60°C CSA Certified operating range -30°C to +50°C
Master station power supply modules are field replaceable units that
can be removed from an operating system so long as the input power source to the module being replaced has been disconnected. Refer to Section 8.4 Replacing Modules for information on removal and installation.
DC power supply modules are available for several different input ranges. These modules have interchangeable connectors. Make sure
the supply is within the rating for the module installed.
When installing DC Power Supply modules, torque thumbscrews to 10 in-lbs, or approximately ¼ turn past hand tight, to insure optimum heat
transfer through thermal contact connector on the rear of the unit.
When connecting DC Power Supply modules, the length of the power cable MUST be no longer than 3 meters.