12~24VDC 12~24VDC 12~24VDC 12~24VDC 12~24VDC
30~60mA/12VDC 40~80mA/24VDC
30~50mA/12VDC 40~60mA/24VDC
20~40mA/12VDC 20~50mA/24VDC
60~100mA/12VDC 80~120mA/24VDC
30~60mA/12VDC 40~80mA/24VDC
Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O
3A/30VDC 3A/24VDC 3A/24VDC 3A/24VDC 3A/24VDC
1~30 seconds
1~30 seconds
Green(Relay) Green(Relay) Green(Relay)
2x6 levels of LED
-20~+70ºC
-20~+70ºC
-20~+70ºC -20~+70ºC
-20~+70ºC
N/O,N/C output setting
BTS Touch Exit Button
The BTS touch sensitive exit button has N.O. and N.C. contact output and can be connected directly to a electromagnetic lock or a proximity reader in series (or in parallel).
Fig.A
Copyright © GIANNI Industries,Inc.All rights reserved. P-MU-BTS Ver.D Published 2011.03.18
1
30 sec.
1
30 sec.
Installation Instruction
Specifications
Wiring Diagram
Mode Operating Voltage
Current Draw Relay contact
output Relay rating
Relay strike time LED status
Temperature Other
indication
indicator
2x6 levels of LED indicator
In Fig.A, BTS controls the fail-safe locking device directly by series connection. BTS relay time is door-opening time.
Power Supply
Power Supply
Control Device (Outdoor)
Relay output control
Relay Timer
Relay Timer
BTS Touch Sensitive Switch (Indoor)
BTS Touch Sensitive Switch (Indoor)
Fig.B
Locking Device
(fail-safe)
Locking Device
(fail-secure)
Control Device (Outdoor)
Relay output control
In Fig.B, BTS controls the fail-secure locking device directly by parallel connection. BTS relay time is door-opening time.
Note:
1. Make sure that the power input and relay rating output (3Amp/24VDC) are correct.
2. Make sure that the “+” and “-” wires are connected correctly.
3. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress the back EMF of the strike. Failure to do so will damage the relay contacts and electronic omponents, or even burn the controller.
Page 2
Copyright © GIANNI Industries,Inc.All rights reserved. P-MU-BTS Ver.D Published 2011.03.18
LED
(Red)
BTS-400-ANSI,300,486
Illustration
JP setting
Warranty
BTS Touch Exit Button
Base Slot hole
Vandal resistant screw Stopper Touch panel
The relay will send the signals from N.C. into N.O. contact after your finger or a metal object touches the touch panel. Time delay can be adjusted from 1 to 30 seconds.
Relay output
Relay output
(Touch)
(Touch)
Relay output
Relay output
(Light stay on)
(Light flash)
(Green)
(Touch)
(Touch)
(Touch)
(Touch)
(Touch)
(Touch)
(Green)
(Off)
(Red)
(Off)
(Red)
(Green)
(Off)
(Green)
(Off)
(Red)
Relay contact output
(dry contact)
12~24 VDC power input
JP setting
Relay Timer
(Sec.)
The product is warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer. The GEM policy is one of continual development and improvement; therefore GEM reserves the right to change specifications without notice.
Loading...