GE Interlogix ShatterPro Plus 5885, 5709C, 5885-W Installation Instructions Manual

Page 1
ShatterPro Plus
Motion Sensitive Acoustic Sensor Model 5885
Installation Instructions
Microphone
Lens
PET
ALLEY
Microphone
Jumper J1 for LED latch
Jumper J1 for LED latch
Cover plate
Jumper J2 for separate glassbreack and PIR
Wiring
Strip back the outer jacket on your wiring cable. This will allow wires to flex in the case. Make sure the cable is slack in the wall to avoid stressing the wires at their connections. The unit should be connected to a UL listed power supply capable of providing 4 hours of standby power.
Mounting
Ceiling Mount
1 . Mount unit in direct line of sight of windows to be
protected.
2 . Sensor can be mounted as close as 3.3 feet (1 m) from
glass and up to 12 feet (3.7 m) from glass. 3 . Select appropriate lens mask for field of view of PIR. 4 . Perform glassbreak and PIR walk test.
Note: When ceiling mounted, be sure to insert “single spot” mask to reduce potential for false alarms.
WIDE
Masking kit
ANGLE
SPOT
-+
T erminals for Power
9-16 VDC
V E R T
I C A L
PET
ALLEY
PIR NC
T erminals for
PIR Relay
B A R R I E R
PIR
COM
Jumper J2 for separate glassbreak and PIR
GBNCGB
COM
T erminals for
Glassbreak Relay
Wall or Corner Mount
1 . Do not aim sensor directly at window - install so PIR
is covering the area of room you expect to have occupied.
2 . Sensor can be mounted as close as 3.3 feet (1 m) from
glass and up to 12 feet (3.7 m) from glass. 3 . Select appropriate lens mask for field of view of PIR. 4 . Perform glassbreak and PIR walk test.
12’
Glassbreak
coverage
12’
PIR coverage
Ceiling Mount
ShatterPro Plus 5885
Glassbreak coverage
PIR coverage
12’
12’ Glassbreak coverage
PIR coverage
Wall Mount Corner Mount
1
Page 2
Zone Pattern Masking the PIR
Choose which masking plate you need, if any, and cut to
Wall Mount No Mask
Top V iew
0
Side View
7’
2.1m
9.1m
0
30’
10’
3.0m
54°
54°
20’
6.1m
38.4°
38.4°
9.1m
20°
20°
40’
12.2m
30’
40’
12.2m
Wall Mount With Pet Alley Mask
360° Ceiling Mount With Single Spot Mask
0°
15’ (4.8 m) x 20’ (6.2 m)
capture zone
25’ (7.2 m) diameter
coverage pattern
Note: Intruder must enter coverage pattern 3-4 feet (1-1.2 m) to cross one zone for detection of alarm. False alarm sources, such as heaters, should be kept out of the coverage pattern.
Wall Mount With Wide Angle Mask
match the lens. Insert behind the lens on the front cover by pressing over 3 mounting pins. Once the front cover is installed the masking plate will be held tight against the lens.
Cut to Match Lens
Inside of Front Cover
Note: Masking plates have a notch to prevent incorrect installation. The notch matches a rib in the front cover.
WIDE
ANGLE
Align Notch with Dimple
Align Notch with Rib
Top V iew
0
Side View
3’
0,9m
30’
9.1m
10’
3.0m
20’
6.1m
0
30’
9.1m
40’
12.2m
12.2m
90°
40’
Wall Mount With Vertical Barrier Mask
Top V iew
0
40’
12.2m
10°
Top V iew
0
30’
Side View
7’
2.1m
9.1m
10’
3.0m
20’
6.1m
0
30’
9.1m
40’
12.2m
12.2m
40’
Wall Mount With Single Spot Mask
Top V iew
0
12.2m
Rotate
90°
Cut to Match Lens
Inside of Front Cover
PET
ALLEY
ROTATE LENS
180
o
Lens 180°
Note: To correctly mount the Pet Alley mask, the lens must be removed from the front cover and rotated 180° and cut to fit.
10°
40’
Side View
7’
2.1m 10’
20’
30’
0
3.0m
6.1m
9.1m
40’
12.2m
2
Side View
7’
2.1m
7°
10’
20’
30’
0
3.0m
6.1m
9.1m
40’
12.2m
ShatterPro Plus 5885
Page 3
Application Tips
Testing the Sensor
The ShatterPro Plus provides two separate relays, one for the glassbreak sensor and one for the PIR. This configura­tion allows the ShatterPro Plus to be used in a variety of applications.
Application 1 - 24 Hour Glassbreak
Jumper 1
5885 Circuit Board
In this application, the glassbreak relay is wired to a separate 24-hour zone and Jumper 2 is placed across one pin. Now, any time a person enters the field of view of the PIR, the glassbreak sensor will be disabled. The glassbreak sensor
will automatically turn back on one minute after the PIR’s field of view is vacated. This application is ideal for kitchens,
garages, and other small, accoustically-live rooms that may incur loud occupant-generated sounds. It is also great for 24-hour perimeter protection in commercial installations that employ access control.
Jumper 2
GB COM
GB NC
PIR COM
PIR NC
24-Hour Zone
+
-
Control Panel
Application 2 - 24-Hour Glassbreak and Interior Backup PIR
Jumper 1
Jumper 2
GE Interlogix recommends testing the sensor to confirm that the field of view is set correctly and that the glassbreak detector will detect at the desired mounting location.
T o test the field of view: Walk into the intended occupied area. The green LED should blink at 1 Hz for 1 minute. This means that the sensor has adjusted to presence in the room and turned off the glassbreak alarm relay for 1 minute. It will turn the glassbreak on only after no movement has been detected for 1 minute. The LED will also hold 4 seconds solid green indiating motion detection by the PIR.
T o test the glassbreak only: Place the Jumper J2 on two pins so the motion sensing device is separated from glassbreak. Place the 5709C tester next to the microphone and put the unit into test mode by firing off the tester. The unit will be blinking red. Position yourself next to the glass you want to detect, select the appropriate glass type, and test the unit If drapes or blinds are present, test behind them. The LED will go solid red for 4 seconds if glass is within detection range.
®
GB COM
GB NC
PIR COM
5885 Circuit Board
PIR NC
+
-
In this application, the glassbreak relay is wired to a 24-hour zone, the PIR relay is wired to a separate interior zone, and Jumper 2 is placed across one pin. The PIR relay is wired to the control panel to provide PIR backup for interior protec­tion. Now when the interior zone is armed, the PIR will also act as a motion detector that will trigger an alarm if someone enters the room. This application is an affordable way to get two sensors in one installation.
Application 3 - Perimeter Glassbreak and Interior Backup PIR
Jumper 1
5885 Circuit Board
In this application, the glassbreak relay is wired to a separate perimeter (non 24-hour) zone, the PIR relay is wired to a separate interior zone, and Jumper 2 is placed across two pins. This configuration is a very affordable way to get two sensors in one, a glassbreak and a PIR. It’s perfect for installations that don’t require 24-hour operation, but are armed at night, during unoccupied hours, or during quiet occupied hours.
ShatterPro Plus 5885
Jumper 2
GB COM
GB NC
PIR COM
PIR NC
+
-
24-Hour Zone
Interior Zone
Control Panel
Non 24-Hour Perimeter Zone
Interior Zone
Control Panel
LED Indicators for T esting and Alarm
Glassbreak Alarm = 4 seconds solid red Glassbreak T est =1 Hz blinking red for 1 minute Glassbreak Latched = Solid red Hand Clap Test = 2 red blinks PIR Alarm = 4 seconds solid green PIR Shunting Glassbreak =1 Hz blinking green for 1 minute
Note: Each time the glassbreak sensor alarms, it also goes into test mode for 1 minute.
Checking the ShatterPro Plus
The ShatterPro Plus can be checked by the installer or end­user while in normal mode by simply clapping hands loudly under the sensor. The LED will blink twice, but the sensor will not trip. This verifies visually that the microphone and circuit board are functioning.
When the ShatterPro Plus trips to an actual alarm condition, it will latch solid for 4 seconds, then start blinking for 1 minute. At the end of 1 minute, the LED will extinguish unless set for “LA TCHING LED”.
Using Latching LED
1 . Remove Jumper J1 to latch the LED for glassbreak. 2 . When the unit alarms for glassbreak, the LED will
remain solid red after exiting test mode.
3 . Reset the unit by removing power for at least 1 second.
3
Page 4
Specifications
x
Electrical
Operational voltage..................................................9 to 16 VDC
Current draw.......................................15mA typical, 30 mA max.
Alarm outputs......Normally closed, open 4 seconds on alarm
On resistance...........................................5 to 15 Ohms
Off resistance..............................................>1 MOhms
Maximum loop rating
(relay or tamper loop)..........................16 VDC, 50 mA
Fails safe and opens on power loss
Wire gauge ...............................................................14 - 22 A WG
Environmental
Lightning suppression....................400 watts for 1 msec pulse
Operating temperature............0° F to 120° F (-18° C to +50° C)
RFI immunity..............................20 V/meter from 1 to 1000MHz
Humidity .........................................10% to 90% noncondensing
Dimensions
2.2” (5.6 cm)
1.2"
3.1cm
3.7” (9.4 cm)
PIR Features
Pulse count................................Bi-directional, 1 zone (2 pulses)
with Motion V erification
Range
1. Wide Angle (90° )....................................30’ x 30’ (9.1m x 9.1m)
7’ (2.1 m) mounting height
2. 360° Ceiling ..........15’ x 20’ (4.6 m x 6.1 m) at 8’ (2.4 m) height
16’ x 30’ (4.9 m x 9.1 m) at 12’ (3.7 m) height Ceiling mounting height up to 12’ (3.7 m)
3. Single Spot.....40’ (12.2 m) range, 7’ (2.1 m) mounting height
4.V ertical Barrier ..40’ (12.2 m) range, 7’ (2.1 m) mounting height
5. Pet Alley (90°)..30’ (9.1 m) range, 3’ (0.9 m) mounting height
Acoustic Glassbreak Features
Microphone...................................Omni directional 360° electret
Sensitivity setting........................................................Factory set
Range..............................12’ (3.7 m) from ceiling to window wall
12’ (3.7 m) to side wall
Glass types detected:
Plate glass.....................1/8” (3.2 mm) to 1/4” (6.4 mm)
Tempered glass.............1/8” (3.2 mm) to 1/4” (6.4 mm)
Wired glass.............................................. 1/4” (6.4 mm)
Laminated glass....................................... 1/4” (6.4 mm)
Mounting location.....Ceiling or any wall except opposite wall
Minimum distance from glass........................................3.3’ (1 m)
Minimum glass size......................................1’ (0.3 m) x 2’ (0.6 m)
Dimensions.............................................................3.7” (9.4 cm) H
2.2” (5.6 cm) W
1.2” (3.1 cm) D
Housing material............................Flame retrardant ABS plastic
Color.............................................................................White/white
Shunting feature.........Glassbreak automatically turns back on
1 minute after vacating PIR’s field of view
Ordering Information
Description Model Number Color Listing
ShatterPro Plus 5885-W White UL 63 9 Hand Held T ester 5709C
www.GE-Interlogix.com
© 2003 GE Interlogix
12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 T echnical Service: 800-648-7424 FaxBack: 800-483-2495
GE Interlogi
12287 Rev F 09/03
Loading...