Strip back the outer jacket on your wiring cable. This will
allow wires to flex in the case. Make sure the cable is slack in
the wall to avoid stressing the wires at their connections. The
unit should be connected to a UL listed power supply
capable of providing 4 hours of standby power.
Mounting
Ceiling Mount
1 .Mount unit in direct line of sight of windows to be
protected.
2 .Sensor can be mounted as close as 3.3 feet (1 m) from
glass and up to 12 feet (3.7 m) from glass.
3 .Select appropriate lens mask for field of view of PIR.
4 .Perform glassbreak and PIR walk test.
Note: When ceiling mounted, be sure to insert
“single spot” mask to reduce potential for false
alarms.
WIDE
Masking kit
ANGLE
SPOT
-+
T erminals for Power
9-16 VDC
V
E
R
T
I
C
A
L
PET
ALLEY
PIR
NC
T erminals for
PIR Relay
B
A
R
R
I
E
R
PIR
COM
Jumper J2 for separate
glassbreak and PIR
GBNCGB
COM
T erminals for
Glassbreak Relay
Wall or Corner Mount
1 .Do not aim sensor directly at window - install so PIR
is covering the area of room you expect to have
occupied.
2 .Sensor can be mounted as close as 3.3 feet (1 m) from
glass and up to 12 feet (3.7 m) from glass.
3 .Select appropriate lens mask for field of view of PIR.
4 .Perform glassbreak and PIR walk test.
12’
Glassbreak
coverage
12’
PIR coverage
Ceiling Mount
ShatterPro Plus 5885
Glassbreak coverage
PIR coverage
12’
12’ Glassbreak coverage
PIR coverage
Wall MountCorner Mount
1
Page 2
Zone PatternMasking the PIR
Choose which masking plate you need, if any, and cut to
Wall Mount
No Mask
Top V iew
0
Side View
7’
2.1m
9.1m
0
30’
10’
3.0m
54°
54°
20’
6.1m
38.4°
38.4°
9.1m
20°
20°
40’
12.2m
30’
40’
12.2m
Wall Mount
With Pet Alley Mask
360° Ceiling Mount
With Single Spot Mask
0°
15’ (4.8 m) x 20’ (6.2 m)
capture zone
25’ (7.2 m) diameter
coverage pattern
Note: Intruder must enter
coverage pattern 3-4 feet (1-1.2
m) to cross one zone for
detection of alarm. False alarm
sources, such as heaters,
should be kept out of the
coverage pattern.
Wall Mount
With Wide Angle Mask
match the lens. Insert behind the lens on the front cover by
pressing over 3 mounting pins. Once the front cover is
installed the masking plate will be held tight against the
lens.
Cut to
Match Lens
Inside of
Front Cover
Note: Masking plates have a notch to prevent
incorrect installation. The notch matches a rib in
the front cover.
WIDE
ANGLE
Align Notch
with Dimple
Align Notch
with Rib
Top V iew
0
Side View
3’
0,9m
30’
9.1m
10’
3.0m
20’
6.1m
0
30’
9.1m
40’
12.2m
12.2m
90°
40’
Wall Mount
With Vertical Barrier Mask
Top V iew
0
40’
12.2m
10°
Top V iew
0
30’
Side View
7’
2.1m
9.1m
10’
3.0m
20’
6.1m
0
30’
9.1m
40’
12.2m
12.2m
40’
Wall Mount
With Single Spot Mask
Top V iew
0
12.2m
Rotate
90°
Cut to
Match Lens
Inside of
Front Cover
PET
ALLEY
ROTATE LENS
180
o
Lens 180°
Note: To correctly mount the Pet Alley mask, the
lens must be removed from the front cover and
rotated 180° and cut to fit.
10°
40’
Side View
7’
2.1m
10’
20’
30’
0
3.0m
6.1m
9.1m
40’
12.2m
2
Side View
7’
2.1m
7°
10’
20’
30’
0
3.0m
6.1m
9.1m
40’
12.2m
ShatterPro Plus 5885
Page 3
Application Tips
Testing the Sensor
The ShatterPro Plus provides two separate relays, one for
the glassbreak sensor and one for the PIR. This configuration allows the ShatterPro Plus to be used in a variety of
applications.
Application 1 - 24 Hour Glassbreak
Jumper 1
5885
Circuit
Board
In this application, the glassbreak relay is wired to a separate
24-hour zone and Jumper 2 is placed across one pin. Now,
any time a person enters the field of view of the PIR, the
glassbreak sensor will be disabled. The glassbreak sensor
will automatically turn back on one minute after the PIR’s
field of view is vacated. This application is ideal for kitchens,
garages, and other small, accoustically-live rooms that may
incur loud occupant-generated sounds. It is also great for
24-hour perimeter protection in commercial installations that
employ access control.
Jumper 2
GB COM
GB NC
PIR COM
PIR NC
24-Hour Zone
+
-
Control
Panel
Application 2 - 24-Hour Glassbreak and
Interior Backup PIR
Jumper 1
Jumper 2
GE Interlogix recommends testing the sensor to confirm that
the field of view is set correctly and that the glassbreak
detector will detect at the desired mounting location.
T o test the field of view: Walk into the intended occupied
area. The green LED should blink at 1 Hz for 1 minute. This
means that the sensor has adjusted to presence in the room
and turned off the glassbreak alarm relay for 1 minute. It will
turn the glassbreak on only after no movement has been
detected for 1 minute. The LED will also hold 4 seconds
solid green indiating motion detection by the PIR.
T o test the glassbreak only: Place the Jumper J2 on two
pins so the motion sensing device is separated from
glassbreak. Place the 5709C tester next to the microphone
and put the unit into test mode by firing off the tester. The
unit will be blinking red. Position yourself next to the glass
you want to detect, select the appropriate glass type, and
test the unit If drapes or blinds are present, test behind
them. The LED will go solid red for 4 seconds if glass is
within detection range.
®
GB COM
GB NC
PIR COM
5885
Circuit
Board
PIR NC
+
-
In this application, the glassbreak relay is wired to a 24-hour
zone, the PIR relay is wired to a separate interior zone, and
Jumper 2 is placed across one pin. The PIR relay is wired to
the control panel to provide PIR backup for interior protection. Now when the interior zone is armed, the PIR will also
act as a motion detector that will trigger an alarm if someone
enters the room. This application is an affordable way to get
two sensors in one installation.
Application 3 - Perimeter Glassbreak and
Interior Backup PIR
Jumper 1
5885
Circuit
Board
In this application, the glassbreak relay is wired to a separate
perimeter (non 24-hour) zone, the PIR relay is wired to a
separate interior zone, and Jumper 2 is placed across two
pins. This configuration is a very affordable way to get two
sensors in one, a glassbreak and a PIR. It’s perfect for
installations that don’t require 24-hour operation, but are
armed at night, during unoccupied hours, or during quiet
occupied hours.
ShatterPro Plus 5885
Jumper 2
GB COM
GB NC
PIR COM
PIR NC
+
-
24-Hour Zone
Interior Zone
Control
Panel
Non 24-Hour
Perimeter Zone
Interior Zone
Control
Panel
LED Indicators for T esting and Alarm
Glassbreak Alarm = 4 seconds solid red
Glassbreak T est =1 Hz blinking red for 1 minute
Glassbreak Latched = Solid red
Hand Clap Test = 2 red blinks
PIR Alarm = 4 seconds solid green
PIR Shunting Glassbreak =1 Hz blinking green for 1 minute
Note: Each time the glassbreak sensor alarms, it
also goes into test mode for 1 minute.
Checking the ShatterPro Plus
The ShatterPro Plus can be checked by the installer or enduser while in normal mode by simply clapping hands loudly
under the sensor. The LED will blink twice, but the sensor
will not trip. This verifies visually that the microphone and
circuit board are functioning.
When the ShatterPro Plus trips to an actual alarm condition,
it will latch solid for 4 seconds, then start blinking for 1
minute. At the end of 1 minute, the LED will extinguish
unless set for “LA TCHING LED”.
Using Latching LED
1 .Remove Jumper J1 to latch the LED for glassbreak.
2 .When the unit alarms for glassbreak, the LED will
remain solid red after exiting test mode.
3 .Reset the unit by removing power for at least 1 second.
3
Page 4
Specifications
x
Electrical
Operational voltage..................................................9 to 16 VDC
Current draw.......................................15mA typical, 30 mA max.
Alarm outputs......Normally closed, open 4 seconds on alarm
On resistance...........................................5 to 15 Ohms
Off resistance..............................................>1 MOhms
Maximum loop rating
(relay or tamper loop)..........................16 VDC, 50 mA
Fails safe and opens on power loss
Wire gauge ...............................................................14 - 22 A WG
Environmental
Lightning suppression....................400 watts for 1 msec pulse
Operating temperature............0° F to 120° F (-18° C to +50° C)
RFI immunity..............................20 V/meter from 1 to 1000MHz
Humidity .........................................10% to 90% noncondensing
Dimensions
➝
2.2”
(5.6 cm)
➝
1.2"
3.1cm
➝
3.7”
(9.4 cm)
➝
PIR Features
Pulse count................................Bi-directional, 1 zone (2 pulses)
with Motion V erification
Range
1. Wide Angle (90° )....................................30’ x 30’ (9.1m x 9.1m)
7’ (2.1 m) mounting height
2. 360° Ceiling ..........15’ x 20’ (4.6 m x 6.1 m) at 8’ (2.4 m) height
16’ x 30’ (4.9 m x 9.1 m) at 12’ (3.7 m) height
Ceiling mounting height up to 12’ (3.7 m)
3. Single Spot.....40’ (12.2 m) range, 7’ (2.1 m) mounting height
4.V ertical Barrier ..40’ (12.2 m) range, 7’ (2.1 m) mounting height