GE Interlogix S700VT-MST Instruction Manual

Page 1
Instruction Manual
S700VT-MST
FIBER-OPTIC MINIATURE VIDEO TRANSMITTER
GE Interlogix
Fiber Options
g
Page 2
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used properly in strict accordance with the instructions contained herein, may cause interference to radio communication. It has been tested and found to comply with the limits for Class A computing devices in accordance with the spec­ifications found in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user will be required to take whatev­er means may be necessary to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This apparatus does not exceed the Class A limits for radio noise emission set out in the Radio Interference Regulation of Industry of Canada.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
Federal Communications Commission
and Industry Canada Radio Frequency
Interference Statements
FCC
PART 15 COMPLIANT
Page 3
GENERAL
This manual is a guide to the installation and operation of the S700VT-MST fiber optic video transmitter. Please read the entire manual before installing the equipment.
NOTE: The series numbers S700VR is used the describe all receiver models unless noted otherwise.
The S700VT-MST video transmitters system transmit one video signal one from a camera to a monitoring station over one multimode fiber. The S700VT-MST can be used with the S700VR or S702VR series receivers.
A complete system consists of one transmitter and one receivers.
Unpacking the Unit
In the event that anything is missing from the following list, contact your authorized Fiber Options dealer or representa­tive.
S700VT-MST Transmitter
Instruction manual Save the original packing materials in case it becomes neces­sary to return the unit.
Fiber Options 80 Orville Drive, Bohemia NY 11716-2533 fiber@ge-interlogix.com US Tel: 631-567-8320 or 800-342-3748 Fax: 877-FiberFax (877-342-3732 toll free) or 631-567-8322
For international offices, see the back cover.
www.fiberoptions.com
GE Interlogix
Fiber Options
MODEL S700VT-MMST
MINIATURE VIDEO TRANSMITTER
g
FIGURE 1: BASIC SYSTEM DIAGRAM
one
optical fiber
Video Out
S700VT-MST
S700VR
Video In
INSTRUCTION
MANUAL
FEATURES
The S700VT-MST transmitter housing is extremely small measuring 1.5 in. (38 mm) by 1.04 (26 mm) by 24 mm (0.94 in) . An ST optical connector is fixed to one end, while a coaxial cable with BNC connector and a removable 2-pin screw-terminal power connector are attached at the opposite end.
The S700VT-MST transmitter can be used with any of the fol­lowing receivers: S700VR-EST, S700VR-RST, S702VR-RST. The S702VR-RST supports two transmitters.
All the receivers feature a diagnostic LEVEL/LOSS
TM
LED to indicate the presence of valid fiber signal. (S702V cards have two such LEDs).
Refer to TROUBLESHOOTING for more information. Rack­mount receivers are designed to be mounted in a standard 19­inch card cage (515R1 or 517R1). Electrical power input is derived from the card cage.
Page 4
INSTALLATION
The S700VT-MST transmitter is intended to be located on or near a CCTV camera. If the camera is mounted outdoors, the S700VT-MST must be mounted inside the camera housing. Make sure there is sufficient space for making the various cable, electrical, and fiber connections.
VelcroTMfastener tape is provided for mounting the S700VT­MST to any smooth, flat surface. See Figure 2 for unit dimen­sions.
1. Adhere the fastener tape to the transmitter by removing the protective backing from the gummed tape. Firmly press the tape to the unit.
2. Fasten the other piece of Velcro to the selected surface in the same way. The S700VT-MST can now be mounted to the sur­face by attaching the two pieces of fastener tape to each other.
CONNECTIONS
All fiber-optic links convert electrical signals into a light source at the transmitter and convert the light back to electrical signals for output at the receiver.
CAUTION: Make sure all peripheral equipment that will be connected to the fiber unit is turned OFF during installation.
Video Cable Connection
Connect the video equipment, such as a camera, to the S700VT-MST transmitter using the attached coaxial cable.
Fiber Optic Cable Connection
The standard optical connector on S700VT-MST units is the ST type. Connect the pre-terminated fiber to the two fiber units.
Power Connections
A removable 2-pin screw-terminal connector is provided for the electrical connection.
1. Make sure the power supply is not connected to any power source and attach the leads from the power supply to the appropriate terminals as follows:
Pin 1: +13.5 VDC (DC+) or 12 - 14 VAC Pin 2: Ground (DC-) or 12 - 14 VAC
2. Plug the power supply into a suitable outlet.
Once the S700VT-MST has been installed and the other end of the fiber connected to a suitable receiver, power up the periph­eral equipment.
TROUBLESHOOTING
Operation of a system including an S700VT-MST transmitter can be monitored with the LEVEL/LOSS
TM
LED on the
S700VR or S702VR receivers.
When green, LEVEL/LOSS indicates the presence of sufficient optical and video signals being received from the transmitter. If unlit, check fiber and all connections and splices. Also check that the transmitter is connected to an operating video source, is on, and is connected to the receiver via the fiber.
www.fiberoptions.com
fiber@ge-interlogix.com free phone: 800.342.3748 free fax: 877.342.3732
2
FIGURE 2: MODULE DIMENSIONS
Page 5
www.fiberoptions.com
fiber@ge-interlogix.com free phone: 800.342.3748 free fax: 877.342.3732
3
NOTE: A blank video screen can be a valid video input.
If the S700V fails to operate and the cause of the failure can­not be determined, it may be necessary to contact Fiber Options.
MAINTENANCE
There is no operator maintenance other than keeping the units clean.
CONTACTING FIBER OPTIONS
If you cannot determine the cause of your problem and are in the U.S. or Canada, call the Fiber Options Headquarters in Bohemia, NY. If you are outside the U.S. or Canada, call the closest international office listed on the back page of this man­ual.
Have the following information available: exact model number and product code of your fiber-optic links, and a listing of the diagnostic indicators and their respective color/condition.
SHIPPING AND PACKAGING
Before shipping or transporting your Fiber Options unit, pack it securely to prevent damage that could occur in transit. Use care to protect all connectors, LEDs, and corners from possible damage.
RETURNS TO FIBER OPTIONS
If any equipment must be returned to Fiber Options for repair or replacement, you must obtain authorization from our Return Authorization department before shipping.
If you are in the U.S. or Canada, call our NY headquarters at 631-567-8320 or 800-342-3748.
Customers in other countries should contact their regional rep­resentative listed on the back cover of this manual. A Return Authorizations representative will provide full instructions for returning your product at that time.
NOTE: All authorized returns must be clearly marked with the Return Authorization information. Please follow the instruc­tions completely.
NOTE: Fiber Options will not accept return delivery of any product without prior authorization.
Page 6
All specifications are subject to change without notice. Information furnished by FIBER OPTIONS is believed to be accurate and reliable. However, no responsibility or liability is assumed by FIBER OPTIONS for its use, nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or other rights of FIBER OPTIONS.
11-M700V-A
Copyright 2001 by FIBER OPTIONS. All rights reserved.
030919
www.fiberoptions.com
80 Orville Drive, Bohemia NY 11716-2533
fiber@ge-interlogix.com
US Tel: 631-567-8320 Fax: 631-567-8322
800-342-3748 877-FiberFax (877-342-3732)
UK Tel: +44 113 238 1668 Fax: +44 113 253 8121
Australia Tel: +61 3 9676 0270 Fax: +61 3 9646 7005
France Tel: +33 01 60 86 54 53 Fax: +33 01 60 86 86 04
Germany Tel: +49 700 34237678 Fax: +49 36256 21991
Hong Kong Tel: +852 2907 8108 Fax: +852 2142 5063
Latin America Tel: 800-342-3748 Fax: 877-342-3732
. . . light years ahead