GE Healthcare AdvantageSim MD Brochure

An efficient, accurate, and integrated virtual simulation software suite.
GE Healthcare
AdvantageSim MD virtual simulation software automatically defines contours and volumes and determines geometric beam placement to improve accuracy and speed of planning for high-precision radiotherapy techniques. AdvantageSim MD's simulation tools provide the latest in simulation and localization technology improving productivity and accuracy.
In the era of advanced radiation therapy, contouring organs at risk and target(s), often using multiple datasets showing anatomical, functional and metabolic or respiratory induced motion information
requires an environment and tools that facilitate productivity and accuracy through efficient automated and manual tools and intuitive user interface. Isocenter marking and beam planning tools are
essential for quick and precise patient positioning, plan setup and efficient palliative and emergency planning cases.
Multi-modality simulation:
Efficient multimodality (CT, MR, PET) workflow offers additional information for accurate treatment plans all on one desktop
Multi-phase simulation (4D):
Review, contour and plan in one session.
Multi-organ auto
segmentation: contour up to 15 critical structures in under 4 minutes.
DICOM-RT and IHE-RO
compliance for seamless interoperability
AdvantageSim MD
Visit us:
www.gehealthcare.com/aw/
applications/advantagesim-md/
Features
With AdvantageSim MD, you can
prepare geometric and anatomical data for external beam radiation treatment before dosimetry planning. Using a set of CT images of the patient in the proposed therapy position, you can automatically or manually define anatomical volumes.
You can utilize additional CT, MR, or
PET studies co-registered with the CT scan to assist planning.
For advanced clinical functionality
and flexibility, you can aid the CT simulation with these available options:
- Multi-modality target definition
- 4D CT and 4D PET respiratory
review
- A suite of automated and semi-
automated CT-based organ segmentation tools
You can take advantage of 3D
contour interpolation that lets you define a full volume contour with a minimum of 3 contours in orthogonal planes.
The application lets you define and
manipulate volumes with automatic thresholding tools, structure drawing (with or without Live Wire to pixel value gradients), and automatic interpolation. Beam placement is facilitated with the automatic isocenter placement
and the beam’s eye view (BEV)
features.
The mouse-driven package has an
easy to use, intuitive user interface.
AW Server 2
Intended Use
Advantage Sim MD is used to prepare geometric and anatomical data relating to a proposed external beam radiotherapy treatment prior to dosimetry planning. Anatomical volumes can be defined automatically or manually in three dimensions using a set of CT images acquired with the patient in the proposed treatment position. Definition of the anatomical volumes may be assisted by additional CT, MR or PET studies that have been co­registered with the planning CT scan. Additionally, CT & PET data from a respiratory tracked examination may be used to allow the user define the target or treatment volume over a defined range of the respiratory cycle. The geometric parameters of a proposed treatment field are selected to allow non-dosimetric, interactive optimization of field coverage. Defined anatomical structures and geometric treatments fields are displayed on transverse images, on reformatted sagittal, coronal or oblique images, on 3 D views created
from the images, or on a beam eye’s
view display with or without the display of defined structures with or without the display of digitally reconstructed radiograph.
Regulatory Compliance
AdvantageSim MD complies with the European CE Marking directive for Medical Devices 93/42/EEC.
With the touch of a button you can
access pre-defined, configurable treatment plan templates, load geometry and field shapes from a palette of templates, and apply pre-defined action sequences for additional ease of use.
Modify contour and field definition
parameters on the fly to tailor thresholds, margins, and display characteristics to individual patient data sets.
Use AdvantageSim MD
independently of the treatment planning system to increase your workflow efficiency. The application can be accessed from a dedicated workstation, a networked client computer, or a compatible scanner console.
You can push completed plans to
an RTP system in standard DICOM RT format. DICOM RT data can be received from DICOM RT compliant systems and re-simulated in AdvantageSim MD.
You can automatically remove the
couch from the image volume for even greater efficiency.
The program’s 3D based display
and manipulation features give you full patient anatomy visualization.
System Requirements
AW Workstation 4.6
© 2012 General Electric Company.
All rights reserved. Data subject to change.
GE and GE Monogram are trademarks of General Electric Company.
* Trademark of General Electric Company.