IC200MDD840 IC200MDD842 IC200MDD843
VersaMax Discrete Mixed Modules,
Product Name
Lifecycle StatusActiveActiveActive
Input Voltage 24 VDC 24 VDC 24 VDC
Output Voltage
Number of Points 20 in/12 out 16 in/16 out 10 in/6 out
Channel to Channel Isolation No No No
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection
On State Current 2.0-5.5 mA 2.0-5.5 mA 2.0-5.5 mA
Off State Current 0-0.5 mA 0-0.5 mA 0-0.5 mA
External Power Supply
Input Impedance 10 kOhms maximum 10 kOhms maximum 10 kOhms maximum
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
24 VDC Pos Logic Input 20 points/
Output Relay 2.0 A, 12 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC 0.5 A for 30 VDC 2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC, 0.2 A
0.5 and 10 0.5 and 0.5 0.5 and 10
No internal fuses or snubbers Short circuit protection, overcurrent
0-125 VDC, 5/24/125 VDC nominal; 0-265
VAC (47-63 Hz), 120/240 VAC nominal
2.0 A for 5-265 VAC or
5-30 VDC, 0.2 A for 31-125 VDC
375 maximum 100 maximum 190 maximum
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
24 VDC Positive Logic Input
10/Output Relay 6
0-265 VAC (47-63 Hz),
120/240 VAC nominal
for 31-125 VDC
No internal fuses or snubbers
VAC (47-63 Hz), 120/240 VAC nominal
10 mA per point minimum,
8.0 A maximum per module;
2.0 Amps for 5 to 265 VAC
maximum (resistive);
2.0 Amps for 5 to 30 VDC
maximum (resistive);
0.2 Amp for 31 to 125 VDC
maximum (resistive)
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.123
VersaMax Control
Process Automation Control Systems
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors,
pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also
have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in
a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD844 IC200MDD845 IC200MDD846
VersaMax Discrete Mixed
Product Name
Lifecycle StatusActiveActiveActive
Input Voltage 24 VDC 24 VDC 120 VAC
Output Voltage
Number of Points 16 in/16 out 16 in/8 out 8 in/8 out
Channel to Channel Isolation No Yes, outputs Yes, outputs
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection No internal fuses No internal fuses or snubbers No internal fuses or snubbers
On State Current 2.0-5.5 mA 2.0-5.5 mA 5 mA minimum
Off State Current 0-0.5 mA 0-0.5 mA 2.5 mA maximum
External Power Supply
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Modules 24 VDC Positive Logic
Input 16/Output 24 VDC 0.5 A 16 points
24 VDC 0-125 VDC, 5/24/125 VDC nominal;
0.5 A for 30 VDC 2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.124
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors,
pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also
have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in
a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD847 IC200MDD848 IC200MDD849
VersaMax Discrete Mixed Modules
Product Name
Lifecycle StatusActiveActiveActive
Input Voltage 240 VAC 120 VAC 0-132 VAC (47 to 63 Hz), 120 VAC nominal
Output Voltage
Number of Points 8 in/8 out 8 in/8 out 8 in/8 out
Channel to Channel Isolation Yes, outputs Yes Yes
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection No internal fuses or snubbers Snubber and MOVs (each output) No internal fuses or snubbers
On State Current 4 mA minimum 5 mA minimum 5 mA minimum
Off State Current 1.5 mA maximum 2.5 mA maximum 2.5 mA maximum
External Power Supply
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
240 VAC Input 8 points/Output Relay
2.0A Isolated 8 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
1 AC cycle minimum and 2 AC cycle
(Hz dependent) maximum and 10.0 OFF
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum
2.0 Amps for 5 to 265 VAC maximum (resistive)
2.0 Amps for 5 to 30 VDC maximum (resistive)
0.2 Amp for 31 to 125 VDC maximum (resistive)
300 maximum 125 maximum 300 maximum
One LED per point shows individual point
on/off state (logic side); OK LED indicates
0.5 A maximum per point, 5.0 A for
one cycle (20 ms) maximum inrush
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
120 VAC Input Isolated 8 points/Output
Relay 2.0 A Isolated 8 points
0-265 VAC (47-63 Hz),
120/240 VAC nominal
2.0 A
1 cycle/2 cycle and
10/10
N/A
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum;
2.0 A for 5-265 VAC maximum (resistive);
2.0 A for 5-30 VDC maximum (resistive);
0.2 A for 31-125 VDC maximum (resistive)
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm 1.956 in), not including the
height of (the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.125
VersaMax Control
Process Automation Control Systems
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors,
pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can also
have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in
a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD850 IC200MDD851
VersaMax Discrete Mixed Modules
Product Name
Lifecycle StatusActiveActive
Input Voltage 0-264 VAC (47-63 Hz), 240 VAC nominal 0 to 15 VDC, +5/12 VDC nominal
Output Voltage
Number of Points 8 out/4 in 16 out/16 in
Channel to Channel Isolation Yes No
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection No internal fuses or snubbers No internal fuses or snubbers
On State Current 4 mA minimum 1.45 mA minimum
Off State Current 1.5 mA maximum 0 to 0.7 mA maximum
External Power Supply N/A +10.2 to +30 VDC, +12/24 VDC nominal
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
240 VAC Input Isolated 4 points/Output
Relay 2.0 A Isolated 8 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
2.0 A 0.5 Amps at 30 VDC maximum (resistive)
1 cycle/2 cycle
and 10/10
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum;
2.0 A for 5-265 VAC maximum (resistive);
2.0 A for 5-30 VDC maximum (resistive);
0.2 A for 31-125 VDC maximum (resistive)
260 maximum 115 maximum
One LED per point shows individual point
on/off state logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
5/12 VDC Input 16 points/Output
12/24 VDC 16 points
+10.2 to +30 VDC, +12/24 VDC nominal
2.0 Amps maximum for 100ms inrush
0.25ms maximum/0.2ms ON
and 1.0ms OFF maximum
2.4kOhms typical @ 12 VDC
0.5 Amps at 30 VDC maximum (resistive);
2.0 Amps maximum for 100ms inrush
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.126
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches
that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
IC200MDL140 IC200MDL141 IC200MDL143
VersaMax Discrete Input
Product Name
Lifecycle StatusActiveActiveActive
Input Voltage 0-132 VAC 0-264 VAC 0-132 VAC
Number of Points 888
Channel to Channel Isolation No No Yes
Input and Output Response
Time- On/Off (ms)
Points per Common 1 group of 8 1 group of 8 8 groups of 1
On State Current 5 mA minimum 7 mA minimum 5 mA minimum
Off State Current 2.5 mA maximum 1.5 mA maximum 2.5 mA maximum
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches
that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
IC200MDL144 IC200MDL240 IC200MDL241
VersaMax Discrete Input
Product Name
Lifecycle StatusActiveActiveActive
Input Voltage 0-264 VAC 0-132 VAC 0-264 VAC
Number of Points 41616
Channel to Channel Isolation Yes No No
Input and Output Response
Time- On/Off (ms)
Points per Common 4 groups of 1 2 groups of 8 2 groups of 8
On State Current 7 mA minimum 5 mA minimum 4 mA minimum
Off State Current 3 mA maximum 2.5 mA maximum 1.5 mA maximum
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches
that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
Points per Common 16 groups of 1 8 groups of 1 8 groups of 1
On State Current 5 mA minimum 7 mA minimum 1.0 mA minimum
Off State Current 2.5 mA maximum 3 mA maximum 0 to 0.1 mA maximum
Input Impedance
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Module, 120 VAC Isolated,
16 points
1 cycle/2 cycles 1 cycle/2 cycles 0.5 maximum
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
100 maximum 60 maximum 40 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module, 240 VAC Isolated,
8 points
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module 125 VDC, Pos/Neg Logic,
Isolated, 8 points
74 K Ohm typical at 125 VDC
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.129
VersaMax Control
Process Automation Control Systems
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches
that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
Number of Points 16 isolated inputs 16 inputs (2 groups of 8) 32 (4 groups of 8)
Channel to Channel Isolation Yes No No
Input and Output Response
Time- On/Off (ms)
Points per Common 16 groups of 1 2 groups of 8 4 groups of 8
On State Current 1.0 mA minimum 1.0 mA minimum 1.0 mA minimum
Off State Current 0 to 0.1 mA maximum 0 to 0.4 mA maximum 0 to 0.4 mA maximum
Input Impedance 74 K Ohm typical at 125 VDC 28 K Ohm typical 28 K Ohm typical
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Module 125 VDC, Pos/Neg Logic,
Isolated, 16 points
0.5 maximum 0.5 maximum 0.5 maximum
80 maximum 70 maximum 140 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input Module
48 VDC, Pos/Neg Logic
(2 Groups of 8), 16 points
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module 48 VDC, Pos/Neg Logic
(4 Groups of 8), 32 points
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.130
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches
that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
IC200MDL640 IC200MDL643 IC200MDL644 IC200MDL650
VersaMax Discrete Input
Product Name
Lifecycle StatusActiveActiveActiveActive
Input Voltage 0-30 VDC 0-15 VDC 0-15 VDC 0-30 VDC
Number of Points 16163232
Channel to Channel Isolation No No No No
Input and Output Response
Time- On/Off (ms)
Points per Common 2 groups of 8 2 groups of 8 4 groups of 8 2 groups of 8
On State Current 2.0-5.5 mA 1.45 mA minimum 1.45 mA minimum 2.0-5.5 mA
Off State Current 0-0.5 mA 0-0.7 mA maximum 0-0.7 mA maximum 0-0.5 mA
Input Impedance 10 kOhms maximum 2.4 kOhms at 12 VDC, typical 2.4 kOhms at 12 VDC, typical 10 kOhms maximum
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Module, 24 VDC
Pos/Neg Logic, 16 points
0.50.250.250.5
25 maximum 70 maximum 140 maximum 50 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in)
x 50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module, 5/12 VDC (TTL)
Pos/Neg Logic, 16 points
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane power
is present
110 mm (4.3 in) x 66.8 mm (2.63 in)
x 50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module, 5/12 VDC (TTL)
Pos/Neg Logic, 32 points
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane power
is present
110 mm (4.3 in) x 66.8 mm (2.63 in)
x 50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module, 24 VDC
Positive Logic, 32 points
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane power
is present
110 mm (4.3 in) x 66.8 mm (2.63 in)
x 50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.131
VersaMax Control
Process Automation Control Systems
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
2.0 A maximum per point,
20 A for one cycle (20 ms)
maximum inrush
One LED per point shows individual
point ON/OFF status (logic side).
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.132
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
2.0 A at 30 VDC maximum (resistive)
per point, 8.0 A max. per module
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
0.50.2/1.0 0.5/0.5
No internal fuses (each output) Short circuit protection, overcurrent
protection, free-wheeling diodes
(each output)
0.5 A at 30 VDC maximum (resistive);
2.0 A inrush maximum for 100 ms
50 maximum 45 maximum 75 maximum
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
power is present.
mating connectors
present. OK LED indicates backplane
power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
0.5 A at 30 VDC maximum (resistive);
2.0 A inrush maximum for 100 ms
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.133
VersaMax Control
Process Automation Control Systems
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
IC200MDL742 IC200MDL743 IC200MDL744
VersaMax Discrete Output Module,
Product Name
Lifecycle StatusActiveActiveActive
Output Voltage
Number of Points 3216 (1 group of 16) 32 (2 groups of 16)
Channel to Channel Isolation No No No
Load Current per Point
24 VDC Positive Logic 0.5A with
ESCP, 32 points
18-30 VDC, 24 VDC nominal 5/12/24 VDC 5/12/24 VDC
0.5 A per point 0.5 A per point 0.5 A per point
VersaMax Discrete Output Module,
5/12/24 VDC Negative Logic, 0.5 A per
point (1 group of 16) 16 points
VersaMax Discrete Output Module,
5/12/24 VDC Negative Logic, 0.5 A per
point (2 groups of 16) 32 points
Input and Output Response
Time- On/Off (ms)
Short circuit protection, overcurrent
Protection
Points per Common 2 groups of 16 1 group of 16 2 groups of 16
2.0 A inrush maximum for 100 ms
for 12/24 VDC mode
150 maximum 70 maximum 140 maximum
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
power is present.
height of the carrier or the
mating connectors
present. OK LED indicates backplane
power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
4.75 to 5.25 VDC, 5 VDC nominal
for 5 VDC-TTL mode; 10.2 to 30 VDC,
12/24 VDC nominal for 12/24 VDC mode
25 mA maximum for 5 VDC-TTL mode,
0.5 A at 30 VDC maximum,
2.0 A inrush maximum for 100 ms
for 12/24 VDC mode
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.134
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
Number of Channels 881212 single ended, one group 4
External Power Supply
Resolution
Update Rate 15.0 ms maximum 15.0 ms maximum 10.0 ms maximum 15 ms maximum 7 ms maximum
Accuracy at 25¢XC
5V Backplane Current
Consumption (mA)
3.3V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Module, 13 Bit ±10 VDC or 0 to
10 VDC Voltage, 8 Channel
±10 VDC or 0 to 10 VDC 4 to 20 mA (default)
Range: 18-30 VDC
including ripple;
Current consumption:
102 mA maximum
1.25 mV = 4 counts 4-20 mA: 5 counts =
±0.3% typical of full scale,
±0.5% maximum of full scale
50 maximum 50 maximum 50 maximum 50 maximum 10 maximum
N/A N/A N/A N/A 115 maximum
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Analog Output
Module, 13 Bit Current,
8 Channel
0 to 20 mA (configured
with jumper)
Range: 18-30 VDC
including ripple;
2A inrush maximum,
100 mA maximum
(no load), 185 mA
maximum (all 8
outputs at full scale)
2.5 uA (~12.7 bits) 0-20 mA:
4 counts = 2.5 uA (13 bits)
±0.3% of full scale (typical),
±0.5% of full scale (max.)
±1% of full scale (max.)
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Analog Output
Module, 13 Bit ±10 VDC
or 0 to 10 VDC Voltage,
12 Channel
±10 VDC or 0 to 10 VDC 4 to 20 mA (default)
Range: 18-30 VDC
including ripple;
Current consumption:
112 mA maximum
1.25 mV = 4 counts 4-20 mA: 5 counts =
±0.3% typical of full scale,
±0.5% maximum of
full scale
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Analog Output
Module, 13 Bit, 0 - 20
mA, 4-20 mA Current, 12
Channel
0 to 20 mA (configured
with jumper)
Range: 18-30 VDC
including ripple;
Current consumption:
2A inrush maximum
100 mA maximum (no load)
270 mA maximum
(all 12 outputs at full scale)
2.5 uA (~12.7 bits) 0-20 mA:
4 counts = 2.5 uA (13 bits)
+/- 0.3% of full scale
(typical),
+/- 0.5% of full scale (max.)
+/-1% of full scale (max.)
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Analog Output
Module, 14 Bit Voltage/
Current 1500 VAC
Isolation, 4 Channel
±10 VDC, 4-20 mA
Range: 19.5-30 VDC
including ripple;
Current consumption:
100 mA maximum
plus load currents
Current mode: 381 nA
nominal Voltage mode: 381
µV nominal
±0.1% maximum of
full scale
FLD PWR LED indicates
the presence of both logic
power and user power.
OK LED indicates
module status.
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.139
VersaMax Control
Process Automation Control Systems
Analog Mixed Modules
Analog mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact
module. Modules require a carrier base (IC200CHSxxx).
IC200ALG430 IC200ALG431 IC200ALG432
VersaMax Analog Mixed Module,
Product Name
Lifecycle StatusActiveActiveActive
Input Range 4-20 mA 0-10 VDC -10 to +10 VDC
Output Range 4-20 mA 0-10 VDC -10 to +10 VDC
External Power Supply
Resolution
Update Rate 0.3 ms maximum 0.3 ms maximum 0.3 ms maximum