GE Digital IC200MDD840, IC200MDD842, IC200MDD843, IC200MDD844, IC200MDD845 Data sheet

...
Process Automation Control Systems
VersaMax Control
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules send control signals to devices such as contactors, indicator lamps, and interposing relays that can also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD840 IC200MDD842 IC200MDD843
VersaMax Discrete Mixed Modules,
Product Name
Lifecycle Status Active Active Active
Input Voltage 24 VDC 24 VDC 24 VDC
Output Voltage
Number of Points 20 in/12 out 16 in/16 out 10 in/6 out
Channel to Channel Isolation No No No
Load Current per Point
Input and Output Response Time- On/Off(ms)
Protection
On State Current 2.0-5.5 mA 2.0-5.5 mA 2.0-5.5 mA
Off State Current 0-0.5 mA 0-0.5 mA 0-0.5 mA
External Power Supply
Input Impedance 10 kOhms maximum 10 kOhms maximum 10 kOhms maximum
Load Current
5V Backplane Current Consumption (mA)
LED Indicators
Dimensions (W x H x D)
24 VDC Pos Logic Input 20 points/
Output Relay 2.0 A, 12 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC 0.5 A for 30 VDC 2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC, 0.2 A
0.5 and 10 0.5 and 0.5 0.5 and 10
No internal fuses or snubbers Short circuit protection, overcurrent
0-125 VDC, 5/24/125 VDC nominal; 0-265
VAC (47-63 Hz), 120/240 VAC nominal
2.0 A for 5-265 VAC or
5-30 VDC, 0.2 A for 31-125 VDC
375 maximum 100 maximum 190 maximum
One LED per point shows individual point on/off state (logic side); OK LED indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules 24 VDC Pos Logic Input 16/Output
24 VDC 0.5 A with ESCP
24 VDC 0-125 VDC, 5/24/125 VDC nominal;
protection, free-wheeling diodes
18-30 VDC, 24 VDC nominal 0-125 VDC, 5/24/125 VDC nominal, 0-265
0.5 Amp at 30 VDC
maximum (resistive);
2.0 Amps maximum for 100ms inrush
One LED per point shows individual point on/off state (logic side); OK LED indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
24 VDC Positive Logic Input
10/Output Relay 6
0-265 VAC (47-63 Hz), 120/240 VAC nominal
for 31-125 VDC
No internal fuses or snubbers
VAC (47-63 Hz), 120/240 VAC nominal
10 mA per point minimum,
8.0 A maximum per module;
2.0 Amps for 5 to 265 VAC maximum (resistive);
2.0 Amps for 5 to 30 VDC maximum (resistive);
0.2 Amp for 31 to 125 VDC maximum (resistive)
One LED per point shows individual point on/off state (logic side); OK LED indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.123
VersaMax Control
Process Automation Control Systems
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules send control signals to devices such as contactors, indicator lamps, and interposing relays that can also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD844 IC200MDD845 IC200MDD846
VersaMax Discrete Mixed
Product Name
Lifecycle Status Active Active Active
Input Voltage 24 VDC 24 VDC 120 VAC
Output Voltage
Number of Points 16 in/16 out 16 in/8 out 8 in/8 out
Channel to Channel Isolation No Yes, outputs Yes, outputs
Load Current per Point
Input and Output Response Time- On/Off(ms)
Protection No internal fuses No internal fuses or snubbers No internal fuses or snubbers
On State Current 2.0-5.5 mA 2.0-5.5 mA 5 mA minimum
Off State Current 0-0.5 mA 0-0.5 mA 2.5 mA maximum
External Power Supply
Input Impedance
Load Current
5V Backplane Current Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Modules 24 VDC Positive Logic
Input 16/Output 24 VDC 0.5 A 16 points
24 VDC 0-125 VDC, 5/24/125 VDC nominal;
0.5 A for 30 VDC 2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.5 and 0.2 ON / 1.0 OFF 0.5 and 10
18-30 VDC, 24 VDC nominal 0-125 VDC, 5/24/125 VDC nominal;
10 kOhms maximum 10 kOhms maximum 8.6 kOhms (reactive) at 60 Hz, typical;
0.5 Amp at 30 VDC maximum (resistive) 2.0 Amps maximum for 100ms inrush
70 maximum 270 maximum 300 maximum
One LED per point shows individual point on/off state (logic side); OK LED indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed
Modules 24 VDC Positive Logic Input
16/Output Relay 2.0A Isolated 8 points
0-265 VAC (47-63 Hz), 120/240 VAC nominal
0.2 A for 31-125 VDC
0-265 VAC (47-63 Hz), 120/240 VAC nominal
10 mA per point minimum
2.0 A for 5 to 265 VAC maximum (resistive)
2.0 A for 5 to 30 VDC maximum (resistive)
0.2 A for 31 to 125 VDC maximum (resistive)
One LED per point shows individual point on/off state (logic side); OK LED indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules 120 VAC Input 8 points/Outpoints
Relay 2.0A Isolated 8 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
1 AC cycle minimum and 2 AC cycle
(Hz dependent) maximum and 10.0 OFF
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
10.32 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum
2.0 A for 5 to 265 VAC maximum (resistive)
2.0 A for 5 to 30 VDC maximum (resistive)
0.2 A for 31 to 125 VDC maximum (resistive)
One LED per point shows individual point on/off state (logic side); OK LED indicates backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.124
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules send control signals to devices such as contactors, indicator lamps, and interposing relays that can also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD847 IC200MDD848 IC200MDD849
VersaMax Discrete Mixed Modules
Product Name
Lifecycle Status Active Active Active
Input Voltage 240 VAC 120 VAC 0-132 VAC (47 to 63 Hz), 120 VAC nominal
Output Voltage
Number of Points 8 in/8 out 8 in/8 out 8 in/8 out
Channel to Channel Isolation Yes, outputs Yes Yes
Load Current per Point
Input and Output Response Time- On/Off(ms)
Protection No internal fuses or snubbers Snubber and MOVs (each output) No internal fuses or snubbers
On State Current 4 mA minimum 5 mA minimum 5 mA minimum
Off State Current 1.5 mA maximum 2.5 mA maximum 2.5 mA maximum
External Power Supply
Input Impedance
Load Current
5V Backplane Current Consumption (mA)
LED Indicators
Dimensions (W x H x D)
240 VAC Input 8 points/Output Relay
2.0A Isolated 8 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
1 AC cycle minimum and 2 AC cycle
(Hz dependent) maximum and 10.0 OFF
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum
2.0 Amps for 5 to 265 VAC maximum (resistive)
2.0 Amps for 5 to 30 VDC maximum (resistive)
0.2 Amp for 31 to 125 VDC maximum (resistive)
300 maximum 125 maximum 300 maximum
One LED per point shows individual point on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
120 VAC Input 8 points/Output 120 VAC 0.5A Isolated 8 points
120 VAC 0-125 VDC, 5/24/125 VDC nominal;
10 mA min, 0.5 A max., 5 A for 1 cycle
(20 ms) max. inrush
1 cycle/2 cycle and
<1/2 cycle/<1/2 cycle
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
10 mA minimum per point,
0.5 A maximum per point, 5.0 A for one cycle (20 ms) maximum inrush
One LED per point shows individual point on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
120 VAC Input Isolated 8 points/Output
Relay 2.0 A Isolated 8 points
0-265 VAC (47-63 Hz),
120/240 VAC nominal
2.0 A
1 cycle/2 cycle and
10/10
N/A
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum;
2.0 A for 5-265 VAC maximum (resistive);
2.0 A for 5-30 VDC maximum (resistive);
0.2 A for 31-125 VDC maximum (resistive)
One LED per point shows individual point on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm 1.956 in), not including the
height of (the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.125
VersaMax Control
Process Automation Control Systems
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules send control signals to devices such as contactors, indicator lamps, and interposing relays that can also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD850 IC200MDD851
VersaMax Discrete Mixed Modules
Product Name
Lifecycle Status Active Active
Input Voltage 0-264 VAC (47-63 Hz), 240 VAC nominal 0 to 15 VDC, +5/12 VDC nominal
Output Voltage
Number of Points 8 out/4 in 16 out/16 in
Channel to Channel Isolation Yes No
Load Current per Point
Input and Output Response Time- On/Off(ms)
Protection No internal fuses or snubbers No internal fuses or snubbers
On State Current 4 mA minimum 1.45 mA minimum
Off State Current 1.5 mA maximum 0 to 0.7 mA maximum
External Power Supply N/A +10.2 to +30 VDC, +12/24 VDC nominal
Input Impedance
Load Current
5V Backplane Current Consumption (mA)
LED Indicators
Dimensions (W x H x D)
240 VAC Input Isolated 4 points/Output
Relay 2.0 A Isolated 8 points
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
2.0 A 0.5 Amps at 30 VDC maximum (resistive)
1 cycle/2 cycle
and 10/10
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
10 mA per point minimum;
2.0 A for 5-265 VAC maximum (resistive);
2.0 A for 5-30 VDC maximum (resistive);
0.2 A for 31-125 VDC maximum (resistive)
260 maximum 115 maximum
One LED per point shows individual point
on/off state logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Mixed Modules
5/12 VDC Input 16 points/Output
12/24 VDC 16 points
+10.2 to +30 VDC, +12/24 VDC nominal
2.0 Amps maximum for 100ms inrush
0.25ms maximum/0.2ms ON and 1.0ms OFF maximum
2.4kOhms typical @ 12 VDC
0.5 Amps at 30 VDC maximum (resistive);
2.0 Amps maximum for 100ms inrush
One LED per point shows individual point on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.126
www.geautomation.com
Process Automation Control Systems
VersaMax Control
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
IC200MDL140 IC200MDL141 IC200MDL143
VersaMax Discrete Input
Product Name
Lifecycle Status Active Active Active
Input Voltage 0-132 VAC 0-264 VAC 0-132 VAC
Number of Points 8 8 8
Channel to Channel Isolation No No Yes
Input and Output Response Time- On/Off (ms)
Points per Common 1 group of 8 1 group of 8 8 groups of 1
On State Current 5 mA minimum 7 mA minimum 5 mA minimum
Off State Current 2.5 mA maximum 1.5 mA maximum 2.5 mA maximum
Input Impedance
5V Backplane Current Consumption (mA)
LED Indicators
Dimensions (W x H x D)
10.32 kOhms (reactive) at 50 Hz, typical
Module 120 VAC,
8 points
1 cycle/2 cycles 1 cycle/2 cycles 1 cycle/2 cycles
8.6 kOhms (reactive) at 60 Hz, typical;
55 maximum 55 maximum 50 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module 240 VAC,
8 points
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module 120 VAC Isolated,
8 points
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.geautomation.com
Automation & Control Systems
1.127
VersaMax Control
Process Automation Control Systems
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Modules require a carrier base (IC200CHSxxx).
IC200MDL144 IC200MDL240 IC200MDL241
VersaMax Discrete Input
Product Name
Lifecycle Status Active Active Active
Input Voltage 0-264 VAC 0-132 VAC 0-264 VAC
Number of Points 4 16 16
Channel to Channel Isolation Yes No No
Input and Output Response Time- On/Off (ms)
Points per Common 4 groups of 1 2 groups of 8 2 groups of 8
On State Current 7 mA minimum 5 mA minimum 4 mA minimum
Off State Current 3 mA maximum 2.5 mA maximum 1.5 mA maximum
Input Impedance
5V Backplane Current Consumption (mA)
LED Indicators
Dimensions (W x H x D)
Module 240 VAC Isolated,
4 points
1 cycle/2 cycles 1 cycle/2 cycles 1 cycle/2 cycles
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
30 maximum 110 maximum 110 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module, 120 VAC Positive Logic,
16 points
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
VersaMax Discrete Input
Module, 240 VAC Positive Logic,
16 points
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Automation & Control Systems
1.128
www.geautomation.com
Loading...