GE ZSA2201RSS User Manual

ZSA2201RSS
Above-the-cooktop Advantium oven Dimensions (in inches)
GE Monogram® Above-the-Cooktop Advantium® Oven
Dimensions and Installation Information (in inches)
IMPORTANT: PLEASE READ CAREFULLY. FOR PERSONAL
SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.
Insure proper ground exists before use.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM, OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.
NEMA 14-30R Wall Receptacle
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
66" MIN.
Mounting
from floor
25-1/2
height
30" MIN.
width required
13"
MAX.
12"
MIN.
16 max
Exhaust outlet connects to 3-1/4" X 10" duct
240V and 120V outlets need to be spaced on the side if the desire is to setup with top exhaust.
A
100˚
Door open
(without
obstruction)
16 max
16-3/8 max
30 max
Minimum distance from door hinge side to adjacent wall should equal 1/2-inch.
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
(Rear)
SIDE VIEW A-A
Cabinet Front
Cabinet Bottom Shelf
Oven Top
Filler Block
Equivalent to Depth of Cabinet Recess
Self-Aligning Screw
Specification Revised 3/11
A
This distance can NOT exceed 2” to ensure proper installation with the provided screws.
Listed by Underwriters Laboratories
140021
ZSA2201RSS
GE Monogram® Above-the-Cooktop Advantium® Oven
Dimensions and Installation Information (in inches)
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Filter Kit
JX81D–Recirculating Charcoal Filter Kit
To be used when the Advantium oven cannot be vented to the outside.
Filter Kit Accessory
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Round Elbow 10 Ft.
D. 45° Round Elbow 5 Ft.
E. 90° Rectangular Elbow 25 Ft.
F. 45° Rectangular Elbow 5 Ft.
G. Roof Cap 24 Ft.
Grille
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Specification Revised 3/11
Listed by Underwriters Laboratories
140021