ZSA2201RSS
Above-the-cooktop Advantium oven
Dimensions (in inches)
GE Monogram® Above-the-Cooktop Advantium® Oven
Dimensions and Installation Information (in inches)
IMPORTANT: PLEASE READ CAREFULLY. FOR PERSONAL
SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED
TO AVOID SEVERE OR FATAL SHOCK.
Insure proper ground
exists before use.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT, DEFORM,
OR REMOVE ANY OF THE PRONGS
FROM THE POWER CORD. DO NOT
USE WITH AN EXTENSION CORD.
NEMA 14-30R Wall Receptacle
Installation Information: This information is not
intended to be used for installing unit described.
Before installing, consult installation instructions
packed with product/kit for current dimensional data.
66" MIN.
Mounting
from floor
25-1/2
height
30" MIN.
width required
13"
MAX.
12"
MIN.
16 max
Exhaust outlet
connects to
3-1/4" X 10" duct
240V and 120V outlets
need to be spaced on
the side if the desire is
to setup with top
exhaust.
A
100˚
Door open
(without
obstruction)
16 max
16-3/8 max
30 max
Minimum distance from
door hinge side to adjacent
wall should equal 1/2-inch.
Note: Outside venting is optional. Vent (duct) can be horizontal or vertical.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
(Rear)
SIDE VIEW A-A
Cabinet Front
Cabinet Bottom Shelf
Oven Top
Filler Block
Equivalent
to Depth of
Cabinet Recess
Self-Aligning Screw
Specification Revised 3/11
A
This distance can
NOT exceed 2” to
ensure proper
installation with
the provided
screws.
Listed by
Underwriters
Laboratories
140021
ZSA2201RSS
GE Monogram® Above-the-Cooktop Advantium® Oven
Dimensions and Installation Information (in inches)
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT.
Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a
standard 3-1/4” x 10” rectangular duct.
If a round duct is required, a rectangular-to-round
transition adaptor must be used. Do not use less than a
6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should
be taken to align exhaust with the space between studs,
or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to
accommodate exhaust.
Filter Kit
JX81D–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
cannot be vented
to the outside.
Filter Kit Accessory
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of
3-1/4” x 10” rectangular or 6” diameter round duct should
not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc.,
present additional resistance to airflow and are equivalent
to a section of straight duct which is longer than their
actual physical size. When calculating the total duct
length, add the equivalent length of all transitions and
adaptors plus the length of all straight duct sections. The
chart below shows the approximate feet of equivalent
length of some typical ducts.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Round Elbow 10 Ft.
D. 45° Round Elbow 5 Ft.
E. 90° Rectangular Elbow 25 Ft.
F. 45° Rectangular Elbow 5 Ft.
G. Roof Cap 24 Ft.
Grille
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Specification Revised 3/11
Listed by
Underwriters
Laboratories
140021