GE Monogram ®
Installation
Instructions
Stainless Steel
36" Built-In
Refrigerators
and Freezers
Modds
ZIRS36N LH- All Refiqgemtor
ZIRS 36N RH- All Refiqgemtor
ZIFS36N LH- All b)'wezer
ZIFS 36N RH- A ll F_vezer

Before you begin - Readthese instructions completely and carefully.
IMPORTANT- Save these instructions for local inspector's use.
IMPORTANT- OBSERVEALL GOVERNINGCODESAND ORDINANCES.
Note to Installer- Be sure to leave these instructions with the Consumer.
Note to Consumer- Keep these instructions with your Owner's Manual for future reference.
Inrlv/'.4 Thisappliance must be properlygrounded.See "Grounding the Refrigerator,"page7.
[.pl___i_BIII _] i,_i II Ill i,_| Cetappareil dolt _tre correctementmis a la terre.Consulter(<Mise a terre durefrigerateur _,page7.
Ifyou received a damaged product, you should
immediately contact your dealer or builder. Proper
installation is the responsibility of the installer. Product
failure dueto improper installation is not covered under
the GEAppliance Warranty. See the Owner's Manual
for wa rranty information.
ForMonogramlocal service ill yourarea,
1.800.444.1845.
ForMonogramService in Canada,
1.888.880.3030.
ForMonogramParts and Accessories,call
1.800.626.2002.
Dueto the weight and size of this refrigerator, and
to reduce the risk of personal injury or damage to
the product -THREE PEOPLEARE REQUIREDFOR
PROPERINSTALLATION.
_,cause du poids et de la taille de ce refrigerator et
pour r_duire le risque de blessure et de dommages,
IL FAUTTROISPERSONNESPOURFAIRE
L'INSTALLATIONCORRECTEMENT.
• Usethis appliance only for its intended purpose.
• Immediately repair or replace electric service
cords that have becomefrayed or damaged.
• Unplugthe refrigerator before cleaning or making
repairs.
• Repairsshould be made bya qualified service
technician.
• II nefaut utiliser cet appareil que pour I'usage
pour lequel il a 6te construit.
• IIfaut rGparer ou remplacer immediatement tout
cordon d'alimentation 61ectriqueeffiloch6 ou
endommag&
• D_brancher le rGfrig_rateur avant le nettoyage ou
toute intervention.
• Les rGparations doivent _tre faites par un
technicien qualifi&
Contents
DesignInformation
Flushor Semi-Flush Enclosure Installations ........3
Enclosure Cutout and Product Dimensions .....3,4
Accessory Grille Panel Kits.....................................4
Installation Examples ...........................................4, 5
Product Dimensions .................................................5
InstallationPreparation
Clearances .................................................................6
Electrical and Water Connection Location ..........6
Groundingthe Refrigerator .....................................7
Tools Required...........................................................8
Materials Required...................................................8
Hardware Supplied ...................................................8
Hardware Recommendations .................................8
Flooring .......................................................................8
Step 1:RemovePackaging ......................................8
InstallationInstructions
Step 2:Install Water Line.........................................9
Step 3:Install Side Panels .....................................10
Step 4:Install Anti-Tip Brackets ...........................10
Step 5:Level Refrigerator ......................................11
Step 6:Optional Anti-Tip Precaution ...................11
Step 7:ConnectWater Supply..............................12
Step 8:Connect Power ..........................................12
Step 9:Mount TopGrille Panel .............................12
Step 10:Adjust DoorAlignment ..........................13
Step 11:Install Toekick...........................................13
Step 12:Set Temperature Controls ......................13
Step 13:Start Icemaker .........................................13
ProblemSolving ......................................................13
ZUGSSUnifiedGrille Panel Kit..............................14

Design Infi)rmation
Flush or
Semi-Flush
Enclosure
Installations
Advance Planning
True FlushInstallation
In a flush installation,
the refrigerator door
will align evenly with the front
face of adjacent cabinet doors.
The refrigerator blends into the
surrounding cabinetry.
Monogram built-in refrigerators and freezers can be
installed flush with typical 24-3/4"deep cabinetry.
When installed semi-flush, the case trim will conceal
slight gaps around the enclosure. The refrigerator will
project forward approximately 3/4" beyond the front
face of surrounding cabinetry.
36" Stai*_le,s,_ Steel R_fi'ig'erator,s, t;reezer,s
Semi-Flush Installation
These refrigerators
can also be installed
semi-flush into an enclosure
using the minimum cutout
width. The case trim creates a
frame around the opening.
Side Panel Requirements:
• Side panels are not required whenever the
refrigerator or freezer is installed into an enclosure
or between pantry and oven cabinets.
• Side panels are required whenever the sides of the
product are exposed.
• Side panel sizes vary depending on the type of
installation being made.
Enclosure
Cutout and
Product
Dimensions
• To achieve a flush fit, the finished cutout width must be
at least 36" wide.
• In a semi-flush installation, the finished cutout must be
35-1/2".
• The electrical and water locations must be located
as shown for either type of installation.
35" 24-3/4"
Case _Case
_ Width|Depth
84 .+_
2G3/4"_36" Frame to
Including
Tubular
Handles
_Shipped at 84" installation height.
Can be adjusted to 83-1/2"
or 84-1/2" with grille panel kits.
Frame
To accomplish an attractive installation, you must:
1. Determine the need for side panels.
2. Determine side panel thickness.
3. Order matching side panels from the cabinet
manufacturer. Be sure to provide the exact dimensions.
WallView
'I_ _/_ Electrical
_r _Finish_ Width
841/2" max - 243/4" Total
83 1/2" rain Depth
Finished
Opening
'36" for aflush installation.
35-1/2" Min. for a semi-flush installation.
NOTE:Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width. See installation examples
onthe following page.
_5,,_6,, Area
75" FromFloor
to Bottom
of Electrical
Area
31/2"

Design Infi)rmation
36" Slair_le,v_ Sl_,d R@'ig'_,ralor,s, Fre_,z_,r,s
Side By Side
Installation
Of Freezer
And Refrigerator
841/2"max
831/2"min
Finished
Opening
31/2"
Fora complete food storage center, install a Monogram
Freezerand Refrigerator side byside. For even more
capacity,install two refrigerators and one ortwo freezers.
• OrderZU6SS Unified 6rille Panel Kit for one
continuous stainless steel grille panel.
• Electrical and water locations must be located as
shown for either type of installation. A separate
115V,6OHz,20 amp power supply is recommended
for each product.
*FinishedWidth
_21/2"
"JF_Electrical_ _281/2"_
• _-4" 6q. •
5" 5"
243/4"Total
Depth
Freezer
'72" min. far aflush installation
71-1/2" min.for a semi-flush installation
NOTE:Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished cutout
to calculate rough-in width. See installation examples below.
Refrigerator
WallView
75"FromFloor
toBottom
ofElectrical
Area
Accessory
Grille Panel
Kits
Installation
Examples
Installation
Between
Base and
Wall Cabinets
These models arefactory set for 84" installation height.
Adjustments to 83-1/2"or 84-1/2"heights can be made
bychanging the grille panel.
OrderZGCSS36RH(right hand) or ZGCSS36LH(left
hand) 6rille Panel Kit.These kits include 2grille panels,
for 83-1/2"and 84-1/2"installation heights.
Side panels are required whenever the sides of the
product will be exposed.
1/2"to 3/4"side panels are normally set into place and
fastened to adjacent cabinetry or to the back wall before
rolling the refrigerator or freezer into the opening.
1/4"ThickII I
SidePanels ! I
FinishedDb .
Rough-InDim. _36" I
NOTE:1/4"thicksidepanelscanbeinserted
intothe ease trim, making the rough-in the
Refrigerator or Freezer
sameasthe outsidetrimwidth: 36",
ZUGSSUnified Grille Panel Kit
Forside byside installation, order ZUGSSgrille panel
kit. This kit provides one continuous panel to span the
width of two products installed together for a unified
appearance.
Therefore, the rough-in dimensions must allow for
side panel thickness. In both a flush and semi-flush
installation, the finished dimension (the width of
the opening after side panels are installed) must
accommodate the full width of the product.
See page 10 for side panel sizes.
Refrigerator_
Refrigeratordoor\
Cabinet

Installation
At End-of-Run
Design Infi rmation
36 " Stair_l_,ss Ste_,l I?_fi'ig'_,rators, Freezers
Frameless
Cabinets
I 1/2"Thick[I I
FioishedOim
Roughed-InDim._3T'_
RefrigeratororFreezer
II 1/2"Thick [I I
FinishedDim_L[_]
RefrigeratorandFreezer
installedside-by-side
Side panels, 1/2"minimumthickness are required when
using frameless cabinets. The side panel acts as a
spacer between the cabinet and the case trim and
prevents interference with cabinet door swing.
The leading (front) edge must befinished to match
surrounding cabinetry.
Rough-InDim. i 73"_
II I
Refrigerator_
Cabinet
Refrigeratordoor
Cak
NOTE:1/2"thick side panels shown.
Side panels can be anythickness.
Add side panel thickness to outside
trim width, (36" or 72"for two models)
to calculate the rough-in dimension,
The leading (front) edgemust be
finished to match surrounding
cabinetry.
_ Cabinet_,
Product
Dimensions
1/2"To3/4" SidePanels.L
EdgeFlushWithCabinet
ZIRS36NRH,Refrigerator
ZIFS36NRH,Freezer
Handleon the left side, the door swings left to right.
ZIRS36NLH,Refrigerator
ZIFS36NLH,Freezer
Handle onthe right side, the door swings right to left.
Refrigerators are much heavier at the top than at
the bottom - be extra careful when moving.
Les r6frig6rateurs sent beaucoup plus Iourds en
haut qu'en bas. II faut _tre prudentlors des
d6placements.
10-3/4"Max.
10"Miu.
_ 24-3/4"--
_) Refrigeratordoor\
-- 35"Casef
-- 36"Overall
84-1/2"Max.
83q/2" Min.
2

Clearances
Installation Preparation
130° Door Wall
Swing
I
130° ,,y
Factory set for a 130° door swing. Order WX14X99
adjustable door stop to reduce swing to as little as90°.
When Installed into a corner:
Allow 25"for afull 130° door swing. Allow 15"for pan
removal. Allow 4" min. clearance when door swing is
adjusted to a 90° opening for pan access, but pan
removal is restricted.
Min. to
Wall 130° Door 130° Door
--25"--
,,1 I I
// //
/ / "_x
"--- ......... J/
Clearancesfor Multiple Single Door Installations
In a side-by-side installation of aleft and right door
swing product, no clearance between the units is
required. OrderZUGSS Stainless Steel Unified Grille
Panel Kit for one continuous grille panel.
Min.to
0 _
Swing Swing
"'-_ ......... JJ
90° DoorSwing
___ il
,, i
',, Jj36-3/4"
4"_Min.
to Wall
Min.to
Wall
[,,
,,,,,:,
36 " Slai_le,_,s Steel I?_fi'ig'e*'alo*',s, tcfeezer,s
_15%
J"_ ')',
'\ \,
",\',_),, ',\,
........ ;\_>-".............
Clearances for two productsinstalled side-by-side
with the same(left or right) doorswing
Allow 2"minimum clearance between the products to
prevent door swing interference. Order theWX14X99
adjustable door stop to reduce the factory set 130°
door swing. Allow 15"minimum to a wall to achieve
full drawer extension and pan removal.
NOTE:ZUGSSGrille PanelKit will net fit this installation.
5"
I',,/I [
',""7" I
I" ,,f\ \,, /
,, I \ ,,
/ I \ ,, //
",, , ,,',,' \,'\, /
Clearances for two productsinstalled side-by-side
with right and left side hingestogether
Allow 5"minimum between the two products to prevent
one door from striking the other. Use the WX14X99
adjustable door stop to reduce the factory set 130°
door swing and to allow pan removal.
NOTE:ZUGSSGrille PanelKit will net fit this installation.
Electrical
and Water
Connection
Locations
The water line can be routed through the floor or
back wall.
• The icemaker water line should be:
-Approximately 3-1/2" from the floor on the back wall,
or 3-1/2"from the back wall onthe floor.
-At least 5"from either side of the opening.
A 115volt, 60 Hz 15or 20 amppower supply is
recommended. An individual properly grounded
branch circuit or circuit breaker is recommended,
asnoted on the rating plate.
• Locate the electrical outlet within 5"x 6" shaded area
shown.
-2-1/2" from the left side.
Between 75"and 81"from the floor.
IMPORTANT:To insure aflush fit and access to the
power cord, locate the electrical outlet as shown.
ElectricalOutlet
Location21/2"
31/2,u
/
//////////////////////_
/
WaterLocation X
6 '_
75"