GE ZIFS360NXRH User Manual

maintained but pan removal is restricted.
36" (91.5)
25 3/4" (65.45)
23 7/8" (60.7)
*84"
(213.4)
2 3/4"
(7.0)
*73 1/4"
(186.1)
*3 1/2"
(8.9)
*83 1/2"
(212.1)
64 1/4"
(163.2)
*6 1/2"
(16.5)
SIDE VIEWFRONT VIEW
* Shipping height . Use leveling legs and wheels for maximum 1" height adjustment from shipping height.
OVERALL DIMENSIONS
36" (91.5)
64 1/4"
(163.2)
*73 1/4"
(186.1)
*84"
(213.4)
ZIFS360NXRHGE Monogram® 36" Built-In All-Freezer
2 3/4"
(7.0)
25 3/4" (65.45)
23 7/8" (60.7)
*83 1/2"
(212.1)
SPECIFICATIONS
Overall Width 36" (91.4 cm)
Overall Height 84" (213.4 cm)
Overall Depth 25 3/4" (65.41 cm)
Door Clearance 36 3/4" (93.4 cm)
Cutout Width 35 1/2" (90.2 cm)
Cutout Height 83 1/2" - 84 1/2"
Cutout Depth 24" (61 cm)
(212.1 - 214.6 cm)
Plumbing Requirements 1/4" OD copper
tubing or GE SmartConnect kit
Shipping Weight 569 lb
ATTENTION ELECTRICIAN:
A 115 volt 60Hz., 15 or 20 amp power supply is required. An inidividual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall.
*6 1/2"
(16.5)
* Shipping height . Use leveling legs and wheels for maximum 1" height adjustment from shipping height.
35" (89.0)
Case width
** Allow 25" (63.5) min clearance for 130˚ door swing
36 3/4"
(93.4)
TOP VIEW
*3 1/2"
(8.9)
SIDE VIEWFRONT VIEW
**These units are equipped with a 2-position door stop. The factory set 130° door swing can be adjusted to 90° if clearance to adjacent cabinets or walls is restricted. Allow 15" minimum clearance to wall for pan removal. If the 90˚ door stop position is used, pan access is
Dimensions in parentheses are in centimeters unless otherwise noted. Actual product dimension may vary due to manufacturing tolerances.
Product Specification Created 3/14
SIDE VIEW
W
24" (61.0 )
2"
(5.1)
4"
(10.2)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
FRONT VIEW
ELEC.
35 1/2" (90.2)
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75
1/2
"
(191.8)
From floor
to bottom
of electrical
area
5 1/2"
(14.0)
9"
(22.9)
WITH ANTI-TIP BRACKET
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
GE Monogram® 36" Built-In All-Freezer ZIFS360NXRH
STANDARD INSTALLATION
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
ANTI-TIP BRACKET
35 1/2" (90.2)
ELEC.
9"
(22.9)
5"
(12.7)
A
5 1/2"
(14.0)
WATER
3 1/2"
(9.0)
B
(12.7)
81 1/2"
(207.0)
5"
3 1/2"
75
1/2
(191.8) From floor to bottom
of electrical
area
(8.9)
locations at end
"
Use two
additional hole
of brackets
4"
(10.2)
holes selected
24" (61.0 )
2"
(5.1)
C
L
Screws
mounted
into vertical
wall studs Make sure
are centered on the studs
Wall
Studs
W
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
NOTES
A
Mounting the junction
box in this location will also allow for front accessability through access panel.
B
Water supply area.
WARNING:
The freezer is top heavy and must be secured to prevent the possibility of tipping forward. Failure to do so may result in death or serious injury.
The information below is for cabinet design only.
When installing the anti­tip system you must use the product installation instructions.
The information below applies to all installation constructions:
• A wall bracket, bolts and toggles will be supplied with the unit.
• The bolts will be used to attach bracket to wall in 4 locations. Two of the locations must penetrate the center of the wall studs.
• The toggles are used for stability in drywall and when metal studs are encountered. Lag bolts are used in wood studs.
• In installation opening, measure 81 ½” from floor and draw a horizontal line.
• Locate and mark the wall studs on horizontal line. Verify at least two studs have their centerlines within the center 32.5” of installation opening to ensure 2 wall studs are penetrated.
• The bracket will be centered left to right in opening with bottom of bracket on the horizontal line.
• When unit is placed in opening, the bracket tabs will align with openings in back of the unit. The unit will be secured to the bracket using supplied “L” bolts.
SIDE VIEW INSTALLED
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
See Installation Instructions for detailed instructions.
Product Specification Created 3/14
Loading...
+ 3 hidden pages