ZIDI240PII – GE Monogram Double-Drawer Refrigerator Module
34-1/2"-35"
24" Min.
23-3/4"
34-1/2"
23-3/4" Stainless Steel
Models
24-7/8" Framed Models
1-1/2"
Locate Outlet
9"
Max.
10-1/2"
Depth Including
Handles:
25-7/8" Stainless
Steel Models Only
23-3/4" Min.
34-1/2" - 35"
24" Min.
47-1/2" Min.
1-1/2"
Locate Outlets
9"
Max.
10-1/2"
1-1/2"
9"
Max.
10-1/2"
24"
(Custom panel required)
ZIDS240PSS – GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Dimensions and Specifications (in inches)
Installation Space
For a complete food storage center, install two Monogram refrigeration
modules side-by-side.
Note: Reversible door swing on wine chillers/reserves and beverage
centers only. See below for combination cutout dimensions.
Important Note: Products must operate from separate, properly
grounded receptacles.
The cutout depth must be 24"
• Both models can be installed flush with standard cabinetry
• Designed to be built-in only. Cannot be used free-standing.
• White case and drawer sides, black vented toekick with optional
stainless steel toekick supplied.
Additional Specifications:
• A 120 volt 60Hz., 15 or 20 amp power supply is required. An
individual property grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall as shown. Electrical
must be located on rear wall as shown.
interrupter) is not recommended.
Specification Created 3/04
120030
Note: GFI (ground fault
Additional cutout width may be required for models with
Note:
custom panels.
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
®
appliance questions, visit our website at
GE
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Overlay
Panel
1/4"
Backer
Panel
Door
.10 Inch
Spacer
B
A
1/4" Gap
12-1/2 lbs. max.
B
12-1/2 lbs. max.
Spacer Panel
Backer Panel
Overlay Panel
ZIDI240PII – GE Monogram Double-Drawer Refrigerator Module
(Custom panel required)
ZIDS240PSS – GE Monogram Double-Drawer Refrigerator Module
(Stainless steel)
Grounding the Double-Drawer Refrigerator
IMPORTANT – (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which mates with a standard 3-prong (grounding)
wall receptacle to minimize the possibility of electric shock hazard
from this appliance.
Have the wall outlet and circuit checked by a qualified electrician to
make sure the outlet is properly grounded.
When a standard 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced with a
properly grounded 3-prong wall out.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE
REFRIGERATOR TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
3/4” Overlay Panel Dimensions
Model ZIDI240PII requires customer-provided
overlay drawer panels.
• The overlay panels must be secured to a 1/4"
thick backer panel which slides into the trim.
A .10" thick spacer panel must be placed
between the custom and backer panel.
• Custom handles of your choice, supplied by
your cabinet maker, must be installed on the
overlay panels.
3/4" Overlay Panel Dimensions (in inches)
A (Width) B (Height)
1/4" Backer 23-3/16" 14-11/16"
0.10" Spacer 22-1/2" 14-3/16"
3/4" Overlay 23-5/8" 15-1/16"
NOTE: Max. assembled drawer panel weight
is 25 lbs. (12-1/2 lbs. each panel).
IMPORTANT: Maintain a 1/4" gap between
the panels when installed.
Assemble overlay panels with glue
and screws.
• Center spacer panel on the backer panel,
left to right and top to bottom.
Secure the panels with glue.
• Center the spacer/backer panel on
the overlay panel. Secure with glue
and screws. Countersink screws into
the backer panel.
Specification Created 3/04
120030
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
®
appliance questions, visit our website at
GE
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.