BEFORE YOU BEGIN
Read these instructions completely and carefully.
"IMPORTANT- Save these instructions for
local inspector's use.
IMPORTANT- Observe all governing codes
and ordinances.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions for
future reference.
Skill Level- Installation of this cool<top requires basic mechanical and electrical skills.
Completion time - 1to 3 hours.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
WARNING:
This appliance must be properly grounded. See "Electric Supply", page 6.
AVERTISSEMENT :
Cet appareil dolt _tre mis _ la terre ad_quatement. Voir la section {{ Alimentation _lectrique ))_ la page 6.
For Monogram local service in your area,
1.800.444.1845.
For Monogram Service in Canada, call
1.888.880.3030.
For Monogram Parts and Accessories, call
1.800.626.2002. If you received a damaged cool<top, you should contact
your dealer.
in the Commonwealth of Massachusetts:
This product must be installed by a licensed plumber
or gas fitter. When using ball type gas shut off valves, they shall
be T-handle type.
A flexible gas connector, when used, must not
exceed 3 feet.
CAUTION'.
THESE COOKTOPSSHOULD BE INSTALLED
IN CONJUNCTION WITH A SUITABLE
OVERHEADVENT HOOD. Due to the high heat capacity of this unit, particular attention should be paid to the
hood and duct work installation to assure it meets local building codes.
CES CUISINIF:RESDOIVENT ETRE
MISE EN GARDE :
MONTEES CONJOINTEMENT AVEC UNE
HOTTE_, EVACUATION DE PLAFOND APPROPRIEE.
Etant donn_ la grande capacit_ thermique de cet appareil, une attention particuli_re dolt _tre port_e
au montage de la hotte et du syst_me de gaines pour s'assurer qu'il est conforme aux codes du b_timent
Iocaux. Standard countertop and island installations:
A 1200 CFM hood is recommended for 48" cool<tops. A 600 CFM hood is recommended for 36" cool<tops.
Hoods should be 24" rain. deep and the same width
as the cool<top.
IsJand instaJJations:
Check local building codes for the proper method of gas cool<top installation. Local codes vary. Installation, electrical connections and grounding must comply with applicable codes. In the absence of local codes, the cool<top should be installed in accordance with the
National Fuel Gas Code ANSI 223.1-1990 and National Electrical Code ANSI/NFPA 70-1990.
CAUTION:
These cool<tops are extremely heavy. Due
to the weight and size of the cool<top and to reduce the risk of personal injury or damage to the product, TWO PEOPLEARE REQUIREDFOR PROPER
INSTALLATION.
Ces cuisini_res sont extr_mement Iourds.
MISE EN GARDE :
Tout d_montage r_duira consid_rablement leur poids. En raison du poids et de la taille de la
cuisini_re, dont la manipulation risque d'entrafner des I_sions corporelles ou des dommages au produit,
DEUX PERSONNES SONT NECESSAIRES POUR
PROCEDERA UN MONTAGE ADEQUAT.
CONTENTS
Design Information
Design Information
Models Available ..............................................................3
Accessory Requirements ................................................3
Product Dimensions and Clearances ............................4
Installation Options ..........................................................5
Advance Planning ..........................................................5
Installation Preparation
Tools and Materials Required ........................................6
Power Supply Locations ..................................................6
MODELS AVAILABLE
These cooktops are factory set for either natural gas or liquid propane gas. Order the model for your
installation situation. 48" Natural Gas Models:
ZGU48N4G -4 gas burners, grill and griddle ZGU48N6R -6 gas burners and grill ZGU48N6D -6 gas burners and griddle
48" Liquid Propane Gas Models:
ZGU48L4G- 4 gas burners, grill and griddle ZGU48L6R- 6 gas burners and grill ZGU48L6D- 6 gas burners and griddle
Installation Instructions
Step 1, Remove Packaging ..............................................7
Step 2, Cut the Countertop Opening ..............................7
Step 3, Install the Cooktop ..............................................8
Step 4, Connect Cooktop to Gas......................................8
Step 5, Connect Electrical ................................................9
Step 6, Assemble Burners, Check Ignition ....................9
Finalize Installation ..........................................................10
Installation Checklist ......................................................10
Install the Cooktop Backsplash Accessory ................11
36" Natural Gas Models: ZGU36N4D - 4 gas burners and griddle ZGU36N4R - 4 gas burners and grill ZGU36N6 - 6 gas burners
36" Liquid Propane Gas Models:
ZGU36L4D- 4 gas burners and griddle ZGU36L4R- 4 gas burners and grill ZGU36L6 - 6 gas burners
BACKSPLASH ACCESSORIES
All models require 12" min. clearance to a vertical combustible surface atthe rear. A backsplash accessory is available for installations with less than 12"clearance to the back wall. Order a 12"high backsplash or 22" high backsplash with warming shelf.
Backsplash for 48" Models:
ZX12B48HSS - 12"high backsplash ZX22B48HSS - 22" high backsplash with warming shelf
(2 piece)
Backsplash for 36" Models:
ZX12B36HSS - 12"high backsplash ZX22B36HSS - 22" high backsplash with warming shelf
(2 piece)
INSTALLATION NOTE: A custom backspash may be constructed of non-combustible back wall materials such as ceramic tile, brick, marble
or other stone.
" High BacksplashWith
Shelf
12"HighBacl<splash
Design Information
PRODUCT DIMENSIONS AND CLEARANCES
48" Wide Models
477/8 "__
87/16
AllowAdditional Clearance Belowtile CooktopBurner
Boxfor theRegulatorand GasConnections 7/8"
18"Min.
Mateda]
\\
22-3/4" Min. \
36" Min. to Combustible Material From
Cooking Surface
\
36"WideModels
Allow Additional Clearance Below the CooktopBurner
Boxfor the Regulatorand GasConnections
8-7/16"
9N/2"
3/4"_
t
22,_
,2
_26-5/8'_
_22" High 36" Min.
Backsphsh to Combustibles witll Shelf
\12 mgl aacks_
12" Min. to Combustiblesor
O"Min. to Combustibles with 12" or 22" Backsplash
36" Min.
to
Combustibles
4