GE Versaflood III Instructions Manual

GE
g
READ THOROUGHLY BEFORE INSTALLING
Save instructions for future use.
Lighting Solutions
WARNING
Risk of electric shock
Turn power off before servicingsee instructions
GEH-5959C
INSTRUCTIONS
Versaflood III
GENERAL
This luminaire is designed for use in outdoor applications and should not be installed in areas of limited ventilation or in high ambient temperature enclosures. This fixture should be installed and maintained according to the following recommendations.
UNPACKING
This luminaire has been packed so that no parts should have been damaged during transit. Inspect to confirm.
INSTALLATION
CAUTION
Unit will fall if not installed properly
Follow installation instructions
General:
Fixture access: To open, apply slight downward pressure to the front of the door frame and pull latch. To close fixture, close door until latch engages.
Mounting Plate Installations:
Install fixture onto sign structure and securely fasten using the mounting plate/bracket.
Mounting Plate installation is for uplight only. Please call manufacturer regarding other mounting options.
IMPORTANT: In order to provide a watertight seal, the installer must seal the area around the knock-out holes, with a type of caulking compound such as GE 100% silicone.
Slipfitter Installation:
Rout fixture leads through the Arm Fitting (provided by others) connect to power leads (provided by others). Mount fixture slipfitter to the Arm Fitting and secure by using (4) set screws (provided) as illustrated in Figure 1.
If the Fixture is mounted in a position other than the horizon­tal, use care that the lens door does not abruptly swing down and injure someone. In order to mount at top of sign to be used as a downlight, user needs to order fixture as a V3ST which includes rain shield.
IMPORTANT: In order to comply with established electrical code, the installer must seal the area around the Fixture Slipfitter and the Arm Fitting, with a type of caulking compound such as GE 100% silicone.
WIRING
For electrical connections, refer to wiring diagram on ballast or HF generator.
Make all electrical connections in accordance with the
National Electrical Code and any applicable local code
requirements.
Verify that supply voltage is correct by comparing it to
nameplate.
White Wire
Wire Connectors (3)
Figure 1
J-Box
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting Solutions.
Fixture Mounting Bracket
Silicone Sealant
Black Wire
Ground Wire
Arm Fitting (by others)
Mogul Base
Socket
Socket Set Screws (2)
Draw Pull Latch (2)
Fixture Door and Diffuser
Connect ground lead to the green lead, green ground screw on housing or terminal block provided.
Do not remove insulated connectors from wires not needed for required voltage connection.
LAMP INSTALLATION/REPLACEMENT
Use only lamps specified on nameplate. Observe lamp
manufacturer’s recommendations and restrictions on lamp
operation, particularly ballast type, burning position, etc.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate.
MAINTENANCE
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
WARNING
Risk of burn
Do not touch operating luminaire
It will occasionally be necessary to clean the outside of the refractor to maintain the light level. Frequency of cleaning will depend on the ambient dirt level and the minimum light level which is acceptable to the user. The lens door should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should the optical assembly become dirty on the inside, wipe the reflector and clean the lens door in the above manner and replace any damaged gaskets.
Periodic cleaning on the outside of the door glass will ensure operation at maximum optical efficiency. The glass and reflector (if needed) should be cleaned with non-abrasive soap, cleaner, or detergent solutions, rinsed with cold water and wiped dry.
The light output is also dependent on the age of the lamp. In applications where the light level is critical, it may be desirable to replace lamps before they burn out. The lamp manufacturer can provide data showing how the lamp light output decreases with use.
Lamp Tightness – Mogul Base Lamp: The lamp should be
securely inserted to the NEMA-EEI specified torque of 35 inch­pounds, which is best achieved by very firmly tightening to insure application of sufficient torque. Tightening must be sufficient to fully depress and load the center contact of the socket.
QL induction lamps require assembly. Insert lamp onto power coupler until lamp "clicks". Turn clockwise until second "click" to lock.
NOTE: Lamp/coupler must be mounted on socket bracket
PRIOR to attaching to the reflector skirt.
Dark Sky Shield Installation Instructions (for V3ST)
FIRST STEP, SLIP SHIELD THROUGH FITTER (SEE BOTTOM ILLUSTRATION BEFORE CONTINUING.)
FITTER
THIRD STEP, SLIP FIXTURE ONTO MOUNTING SHAFT AND FASTEN WITH SET SCREWS AND THROUGH BOLT AS ILLUSTRATED.
SECOND STEP, INSTALL #10 SHEET METAL SCREWS IN TEN PLACES. USE PRE-HOLES ON SHIELD. (SEE BOTTOM ILLUSTRATION BEFORE CONTINUING.)
AFTER SLIPPING SHIELD ONTO FIXTURE FITTER, MAKE SHIELD TANGENT TO FIXTURE IN THREE PLACES AS SHOWN BELOW BEFORE FASTENING IN PLACE.
Rain Shield Installation Instructions (for V3ST)
1. Silicone Seam Two Places
2. Place Rain Shield On Top Of Existing Fixture
3. Fasten with #10 Self Tapping Sheet Metal Screws Four Places
#10 SELF TAPING SHEET METAL SCREWS FOUR PLACES
RAIN SHIELD
SEAM TWO PLACES
COMPLETE ASSEMBLED ILLUSTRATION