GE UVH13012MSS, UVH13014MWM, UVH13013MTS, UVH13013MDS Specification Sheet

UVH13012MSS/13MDS/13MTS/14MWM
Kitchen Hub
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above unit. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the Kitchen Hub.
IMPORTANT INFORMATION: When installing the unit over a range, allow minimum of 2" from bottom of unit to top of range backguard to allow for removal of light and vent covers.
VENTILATION OPTIONS: The Kitchen Hub is designed for adaptation to the following three types of ventilation:
-Outside exhaust (vertical – as shown)
-Outside exhaust (horizontal)
-Recirculating (non-vented ductless – see Filter Kit drawing in installation instructions)
INSTA L L ATION IN F O RMATION : This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/ kit for current dimensional data.
29 3/4"
66" MIN.
Mounting
height
from floor
13"
MAX.
12"
MIN.*
16 1/2"
30"
MIN.
width
required
16 1/4"
Exhaust outlet connects to 3 1/4" x 10" duct
*Maximum depth with JX15BUMPWW/BB Bump Out Kit is 15" Bump Out Kit sold separately.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Listed by Underwriters Laboratories
Speci fication Revised 5/19
UVH13012MSS/13MDS/13MTS/14MWM
Kitchen Hub
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, ETC., present additional resistance to airf low and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
DUCT EQUIVALENT FEET A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wal l C a p 40 ft. C. 90° Elbow 10 ft. D. 45° Elbow 5 ft. E. 90° Elbow 25 ft. F. 45° Elbow 5 ft. G. Roof Cap 24 ft.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 5/19