UVH13012MSS/13MDS/13MTS/14MWM
Kitchen Hub
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE: Requires 120V grounded outlet. Electrical receptacle
must be located in cabinet above unit. No additional wiring,
venting or cabinet rebuilding necessary in many cases. Complete
detailed, easy-to-follow installation instructions
and convenient full-size templates are packed with the
Kitchen Hub.
IMPORTANT INFORMATION: When installing the unit over a
range, allow minimum of 2" from bottom of unit to top of range
backguard to allow for removal of light and vent covers.
VENTILATION OPTIONS: The Kitchen Hub is designed for
adaptation to the following three types of ventilation:
-Outside exhaust (vertical – as shown)
-Outside exhaust (horizontal)
-Recirculating (non-vented ductless – see Filter Kit drawing in
installation instructions)
INSTA L L ATION IN F O RMATION : This information is
not intended to be used for installing unit described. Before
installing, consult installation instructions packed with product/
kit for current dimensional data.
29 3/4"
66" MIN.
Mounting
height
from
floor
13"
MAX.
12"
MIN.*
16 1/2"
30"
MIN.
width
required
16 1/4"
Exhaust outlet
connects to
3 1/4" x 10" duct
*Maximum depth
with JX15BUMPWW/BB
Bump Out Kit is 15"
Bump Out Kit
sold separately.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
Speci fication Revised 5/19
UVH13012MSS/13MDS/13MTS/14MWM
Kitchen Hub
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD
EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate
with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a
rectangular-to-round transition adaptor must be used. Do not use less than a
6" diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, ETC., present
additional resistance to airf low and are equivalent to a section of straight
duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent length of all transitions and adaptors plus the
lengths of all straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wal l C a p 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 5/19