GE UVC9300, UVC9360 Owner’s Manual & Installation Instructions

SAFETY INFORMATION ...........3
USING THE HOOD
Controls ................................5
Chef Connect ...........................6
Wi-Fi Connect ...........................6
CARE AND CLEANING
Filters ..................................7
Surfaces ................................8
Lights ..................................8
OWNER’S MANUAL &
INSTALLATION INSTRUCTIONS
UVC9300 UVC9360
Custom
INSTALLATION INSTRUCTIONS ..9
TROUBLESHOOTING TIPS ........ 17
LIMITED WARRANTY ............. 18
ACCESSORIES ..................... 19
CONSUMER SUPPORT ............20
FRANÇAIS
Pour une version français de
ce manuel d’utilisation, veuillez
visiter notre site web à l’adresse
GEAppliances.ca.
Write the model and serial
INSERT HOODS
numbers here:
Model # _________________
Serial # _________________
You can find them on a label on the inside of the hood.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Para consultar una version en
español de este manual de
internet GEAppliances.com.
49-2000894 Rev. 1 05-21 GEA
ESPAÑOL
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.
2 49-2000894 Rev. 1
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
SAFETY INFORMATION
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Do not use this unit with any solid-state speed
control device.
D. This unit must be grounded.
CAUTION
ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION
TO PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE. DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE
TO REDUCE RISK OF FIRE AND
WARNING
TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
A. SMOTHER FLAMES with a close-fitting lid, cookie
sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
B. NEVER PICK UP A FLAMING PAN—You may be
burned.
C. DO NOT USE WATER, including wet dishcloths or
towels—a violent steam explosion will result.
D. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety” published by NFPA.
TO REDUCE THE RISK OF INJURY
READ AND SAVE THESE INSTRUCTIONS
49-2000894 Rev. 1 3
IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING
WARNING
RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high
settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on medium settings.
B. Always turn hood ON when cooking at high heat or
when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
C. Clean ventilating fans frequently. Grease should not
be allowed to accumulate on fan or filter.
SAFETY INFORMATION
D. Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
TO REDUCE THE RISK OF A
TO REDUCE THE RISK OF FIRE,
C. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. When applicable, install any makeup (replacement)
air system in accordance with local building
code requirements. Visit GEAppliances.com for
available makeup air solutions. F. Turn off breaker to adjacent rooms while working.
WARNING
USE ONLY METAL DUCTWORK.
Ŷ'RQRWDWWHPSWWRUHSDLURUUHSODFHDQ\SDUWRI\RXU
hood unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.
TO REDUCE THE RISK OF FIRE,
How to Remove Protective Shipping Film and Packaging Tape
Carefully grasp a corner of the protective shipping film with your fingers and slowly peel it from the appliance surface. Do not use any sharp items to remove the film. Remove all of the film before using the appliance for the first time.
To assure no damage is done to the finish of the product, the safest way to remove the adhesive from packaging tape on new appliances is an application of a household liquid dishwashing detergent. Apply with a soft cloth and allow to soak.
NOTE: The adhesive must be removed from all parts. NOTE: For further cleaning instructions/suggestions,
please refer to the Care and Cleaning section.
READ AND SAVE THESE INSTRUCTIONS
4 49-2000894 Rev. 1
Controls
USING THE HOOD: Controls
326541
1. Rangehood Control Panel: The control panel
is located on the front of the canopy. The position and function of each control button are noted below.
2. Fan On/Off Button: On/Off switch for the fan.
The fan can be operated by pressing any of the fan setting buttons. Hold for 3 seconds to activate Delay Off feature, which automatically turns the fan off after 15 minutes.
3. Fan Setting Button: Speed control for the
fan. Press the Low button for LOW speed, Med for MEDIUM speed, and High for HIGH speed. Hold down the High button for 3 seconds to activate the BOOST speed that will run for 10 minutes. On Remote, press Ÿ to increase fan speed, press ź to decrease fan speed, including Boost.
4. Light Button: On/Dim/Off switch for the LED
lights. Press the Light button to turn the lights on, again to set the lights to dim setting, and again to turn the lights off.
7
2
4
3
7
8
Remote Control
5. Chef Connect: This is a Bluetooth
for use with other compatible Chef Connect enabled products on a cooktop or range. When the device is paired, the light and fan will turn ON at the Default Sync Settings upon receiving a command from the range or cooktop. It will remain ON at that setting until the user changes it. To pair devices, hold down the Chef Connect button for 3 seconds. To turn it back off, hold the button down for another 3 seconds, see the Chef Connect section for details.
®
5
pairing feature
6. IR Sensor: Remote control reciever when used
with Remote Control Kit (UXRC1).
7. Wi-Fi: Hold down the Light and Chef Connect
buttons for 3 seconds to activate the Wi-Fi. The Wi-Fi light turns on when connected Connect section for details to toggle Wi-Fi function.
. On Remote, press Wi-Fi
, see the Wi-Fi
8. Delay Off (Remote only): Press and hold
Delay Off to toggle Delay Off function.
Heat Sensor
Your hood is equipped with a HEAT SENSOR thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.
Ŷ,IEORZHULV2IILWWXUQVEORZHU2QWR0HGVSHHG
Ŷ,IEORZHULV2QDWDORZHUVSHHGVHWWLQJLWWXUQV
blower up to Med speed.
When the temperature level drops to normal, the blower will return to its original setting.
49-2000894 Rev. 1 5
Chef Connect
Chef Connect Operation Bluetooth® Connection
To pair with another device:
To start the pairing process on the hood, press and hold the Chef Connect button for 3 seconds. The backlight for the Low-Med-High-Light-Chef Connect buttons will flash in that sequence until the hood is paired with the range or other device. If the pairing is successful, all five backlights (Low, Med, High, Light, Chef Connect) will flash simultaneously three times and then turn off and the backlight for the Chef Connect button will turn on.
It will time out after 2 minutes if the pairing is not completed, after which the pairing sequence will need to be restarted.
To cancel pairing:
To cancel the pairing, hold the Chef Connect button down for 3 seconds and then turn off the hood.
Default Sync Settings:
The factory default setting for the light will be the brightest.
The factory default setting for the fan sync will be OFF. The user can change the Default Sync Settings by
pressing and holding the Low button for 3 seconds. This will enter the Default Settings Mode. Once in this mode, the backlights for all buttons (Low, Med, High, Light, Chef Connect) will blink On/Off indefinitely and the fan and light will switch to the current Default Sync Setting, so the user knows what the current default value is. At this time, set the light and fan to the desired default levels. Once the user is satisfied with the selection, press and hold the On/Off button for 3 seconds. This will exit this mode. At that time the backlights will stop blinking and the state of the fan and light will change back to their prior state before entering the Default Settings Mode.
Wi-Fi Connect
Connecting your Wi-Fi Connect Enabled hood (on some models)
Your GE Appliances hood is designed to provide you with two-way communication between your appliance and smart device. By using the GE Appliances Wi-Fi Connect features, you will be able to control essential hood operations such as fan speed, light functions, timer/clock function, delay off and filter reset using your smartphone or tablet.*
What you will need
Your GE Appliances hood uses your existing home Wi-Fi network to communicate between the appliance and your smart device. In order to setup your GE Appliances hood, you will need to gather some information:
1. Each GE Appliances hood has a connected
USING THE HOOD: Chef Connect / Wi-Fi Connect
appliance information label that includes an Appliance Network Name and Password. These are the two important details that you will need to connect to the appliance. The label is located on the side of the unit behind the filters.
Connected Appliance Information
FCC ID: ZKJ-WCATA005 IC: 10229A-WCATA001 MAC ID: ************
Sample Label
2. Have your smart phone or tablet ready with the ability to access the internet and download apps.
3. You will need to know the password of your home Wi-Fi router. Have this password ready while you are setting up your GE Appliances hood.
Network: ************ Password: **********
Connect your GE Appliances hood
1. On your smart phone or tablet visit GEAppliances.com/connect to learn more about connected appliance features and to download the appropriate app.
2. Follow the app onscreen instructions to connect your GE Appliances hood.
3. Once the process is complete, the connection light located on your GE Appliances hood display will stay on solid and the app will confirm you are connected.
4. If the connection light does not turn on or is blinking, follow the instructions on the app to reconnect. If issues continue please call 800.220.6899 and ask for assistance regarding hood wireless connectivity.
To connect additional smart devices, repeat steps 1 and 2. Note that any changes or modifications to the remote
enable device installed on this hood that are not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
* Compatible Apple or Android devices and home Wi-Fi network required.
6 49-2000894 Rev. 1
Filters
Be sure the circuit breaker is off and all surfaces are cool before cleaning or servicing any part of the vent hood. The metal baffles channel grease released by foods on the cooktop into the drip trays. The baffles also help prevent
flaming foods on the cooktop from damaging the inside of the hood. The baffles must ALWAYS be in place when the hood is in use. The grease baffles and drip trays are dishwasher-
safe and should be cleaned every month, depending on usage of the hood.
Grease Drip Tray
To install:
Place and seat the drip trays into the designated hood track. Slide them left or right until all trays are side-by­side in place in the track.
To remove:
Carefully, use the grease tray lip to lift the tray upwards and out. The tray will be free of the designated hood track.
To clean:
Swish the drip tray in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleaners.
NOTE: Some discoloration of the filter may occur in the dishwasher.
Drip Tray Replacement
CARE AND CLEANING: Filters
Baffle Metal Grease Filter
To install:
Insert the top of the baffle into the track behind the control panel. The arrows on the side of the baffle should be pointing towards the front of the unit. Slide the baffle up and push the bottom end back until it firmly seats into place.
To remove:
Use front knob to pull filter forward, towards the control panel. The bottom of the filter becomes free of the grease drip tray. Use back knob to pull the baffle away from the track behind the control panel.
It is important for baffles to be placed correctly with arrows on the side pointing towards the front of the unit to channel grease to the drip trays and avoid grease accumulation in the baffles.
To clean:
Swish the filter in hot soapy water and rinse in clean water or wash it in the dishwasher. Do not use abrasive cleansers.
NOTE: Some discoloration of the filter may occur in the dishwasher.
1
2
Baffle Replacement
Baffle Removal
49-2000894 Rev. 1 7
Filters (Cont.)
Charcoal Filter (for recirculation installation only)
NOTE: DO NOT rinse, or put charcoal filter in an
automatic dishwasher.
The charcoal filter is included with the unit. It cannot be cleaned; it must be replaced. It is recommended that the charcoal filter be replaced every 6 months or if it is noticeably dirty or discolored.
Order Charcoal Filter UXCF91
To inquire about purchasing replacement charcoal filters or to find the location of a dealer nearest you, please call our toll-free number:
National Parts Center 800.626.2002 In Canada, call 800.661.1616 or visit geappliances.ca
To Install
1. Remove the grease filters. See Filters section.
2. Install the charcoal filter mounts to either side of the motor using three screws per side.
3. Insert the tab on the charcoal filter into the triangular slot on the mount.
4. Clip the charcoal filter in until it is locked
5. Repeat with second filter on the other side of the motor.
6. Reattach the metal filters. See Filters section.
To Remove
1. Remove grease filters-See Filters section
2. Unclip the charcoal filter by pressing the release clip.
3. Carefully remove charcoal filter from tab.
Surfaces
Charcoal Filter Mount
Stainless Steel Surfaces (on some models)
Do not use a steel wool pad; it will scratch the surface.
To clean the stainless steel surface, use warm sudsy water or a stainless steel cleaner or polish. Always wipe the surface in the direction of the brush line. Follow the cleaner instructions for cleaning the stainless steel surface. Cleaners with oxalic acid such as Bar Keepers Friend Soft Cleanser™ will remove surface rust, tarnish, and
CARE AND CLEANING: Surfaces / Lights / Filters
small blemishes. To receive a coupon for a trial sample of Bar Keepers Friend Soft Cleanser™ follow the link below or scan the QR Code.
barkeepersfriend.com/ge
Lights
CAUTION
1. Before attempting to replace the lights, make sure that the light switch is turned off.
2. Rotate light counterclockwise to unlock and pull out. Wearing latex gloves may offer a better grip.
3. Replace with new light of same type, making sure pins are inserted properly into the sockets of the lamp holder and turn clockwise to lock.
All lamps need to be GU10 compatible.
Allow lights to cool before touching.
Use only a liquid cleanser free of grit and rub in the direction of the brush lines with a damp soft sponge.
To inquire about purchasing stainless steel appliance cleaner or polish, or to find the location of a dealer nearest you, please call our toll-free number:
National Parts Center
800.626.2002 GEApplianceParts.com In Canada, call 800.661.1616 or visit geappliances.ca
Lamp Holder
Rotate the lamp until the pins are located in narrow neck of the socket to lock.
8 49-2000894 Rev. 1
INSTALLATION INSTRUCTIONS
Installation
Custom Insert Hood
UVC9300, UVC9360
Instructions
“If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737) or visit our website at:
GEAppliances.com. In Canada, visit GEAppliances.ca or call 800.561.3344.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Ŷ
IMPORTANT — Save these
instructions for local inspector’s use.
Ŷ
IMPORTANT — Observe all governing
codes and ordinances.
Ŷ
Note to Installer – Be sure to leave these
instructions with the Consumer.
Ŷ
Note to Consumer – Keep these instructions for
future reference.
Ŷ
Skill level – Installation of this vent hood requires
basic mechanical and electrical skills.
Ŷ
Completion time – Approximately 1 to 3 hours
Ŷ
Proper installation is the responsibility of the
installer.
Ŷ
Product failure due to improper installation is not
covered under the Warranty.
CAUTION
these vent hoods and to reduce the risk of personal injury or damage to the product, TWO PEOPLE
ARE REQUIRED FOR PROPER INSTALLATION.
Due to the weight and size of
WARNING
ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be
done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion
and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
C. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the
outdoors.
E. Turn off breaker to adjacent rooms while
working.
WARNING
USE ONLY METAL DUCT WORK.
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
FOR YOUR SAFETY
WARNING
switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
49-2000894 Rev. 1 9
Before beginning the installation,
WARNING
at the main circuit breaker or fuse box before installing.
Installation instructions, describing the intended mounting and wiring of the range hood cord connection kit, shall be provided with each range hood cord connection kit.
Disconnect all electrical power
Installation Preparation
PRODUCT DIMENSIONS
6-15/16"
Design varies by model
11-1/2"
12"
1-15/16"
3-1/8"
18" or 24"
9"
4-1/4"
INSTALLATION PREPARATION
28-1/4" or
34-1/4"
19-1/8"
INSTALLATION CLEARANCES
This vent hood must be installed between the 24" required minimum and 36" recommended maximum above the cooking surface.
Ŷ$OZD\VUHIHUWRWKHFRRNWRSRUUDQJHLQVWDOODWLRQ
instructions for product-specific clearances.
NOTE: Installation height should be measured from the cooking surface to the bottom edge of the cabinet surface.
NOTE: UL requires any combustible surface to be a minimum of 30" above the cooking surface. Lower combustible surfaces may be covered to meet requirements.
Ŷ7KHFXVWRPFDELQHWLQWHUQDOKHLJKWPXVWEH
18-1/2" minimum for vertical venting and 29" minimum for recirculation.
Ŷ7KLVKRRGFDQEHYHQWHGWRWKHRXWGRRUVRULW
can be installed for recirculating operation. For recirculating operation, refer to Recirculating Installation Planning.
Ŷ7KLVKRRGPD\EHPRXQWHGLQDZDOOFDELQHWRU
installed over an island.
CABINET PREPARATION
FRONT VIEW
11-1/2"
1" 1"
SIDE VIEW
11-1/2"
18-1/2" min.
29" min.
18-1/2" min.
11-1/2"
*24" Minimum required *36" Maximum recommended
Typically 36"
NOTE: The exhaust duct on the hood is closer to the rear of the hood. It is important to plan for the alignment to the connection point of the hood.
6-1/2"
3" 1"
1" = 2.5 cm
10 49-2000894 Rev. 1
Installation Preparation
TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED)
INSTALLATION PREPARATION
Aluminized
Pencil and tape measure
Level
Tin snips
Wire cutter/
stripper
duct tape
Flashlight
UL listed wire nuts
Step ladder
Phillips and flat-blade
PARTS PROVIDED
Locate the parts packed with the hood. NOTE: The hardware bag may contain extra pieces
to accommodate a variety of installation methods for various models.
screwdrivers
PLAN THE INSTALLATION
properly exhaust air, be sure to duct the air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
Needle-nose pliers
Safety glasses
Strain relief for
CAUTION
Electric drill and
appropriate bits
8" ducting and
caps as needed
junction box
Gloves
To reduce risk of fire and to
Hardware Bag
A
Phillips Head
Wood Screws
3/16" x 1-1/2"
(QTY: 4)
D
Phillips Head
Wood Screws
1/8" X 3/8" (QTY: 4)
Hood
B
Philips Head
Machine Screw
1/8" X 3/8"
(QTY: 16)
Phillips Head
Wood Screws
3/16" x 1"
(QTY: 8)
WARNING
PERSONAL INJURY HAZARD It is recommended that 2 people are used to
install the range hood. Failure to properly lift rangehood could result in damage to the product or personal injury.
NOTE: This rangehood can be installed as either
ducted or recirculation. In a ducted application, this rangehood can be vented through the wall or ceiling. When installed for recirculation, the rangehood vents back into the room.
Damper
Assembly
L
REMOVE THE PACKAGING
CAUTION
Wear gloves to protect against
sharp edges.
Ŷ Remove the hardware bag, literature package
and other boxed parts.
Ŷ Remove and properly discard the protective
plastic wrapping and other packaging materials.
1" = 2.5 cm
49-2000894 Rev. 1 11
Installation Preparation
ADVANCE PLANNING
Duct Install Planning
Ŷ7KLVKRRGLVGHVLJQHGWREHYHQWHGYHUWLFDOO\
through the ceiling. Use a 8" round duct. Use locally supplied elbows to vent horizontally through the rear wall.
Ŷ8VHPHWDOGXFWZRUNRQO\
Ŷ'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
ŶPlan the route for venting exhaust to the outdoors.
To maximize the ventilation performance of the vent system:
1. Minimize the duct run length and number of transitions and elbows.
2. Maintain a constant duct size.
3. Seal all joints with duct tape to prevent any leaks.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduces performance.
INSTALLATION PREPARATION
Ŷ0D[LPXPHTXLYDOHQWGXFWOHQJWKIRU&)0
150 foot for vent hoods.
Ŷ,QVWDOODZDOOFDSRUURRIFDSZLWKGDPSHUDWWKH
exterior opening. Purchase the wall or roof cap and any transition and length of duct needed in advance.
ŶWhen applicable, install any makeup (replacement)
air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
Vent system can terminate either through the roof
RUWKHZDOO7RYHQWWKURXJKDZDOOD๦HOERZLV
needed and installed immediately above the hood.
Roof Cap
Add Insulation
and/or Caulk
Round Duct
ADVANCE PLANNING (CONT.)
Custom Cabinet Frame Planning
ŶThe custom canopy or cabinet should have a
rectangular hole to accommodate the custom hood insert by itself. This hole is the same size for both a wall installation and an island installation. Ensure parallelism and levelness of the cabinet so that it doesn't affect flushness of the hood with the cabinet.
Front of hole must be 3" minimum from cabinet front
Depth
Width
UVC9300 UVC9360
Width (in.) 28-1/4 34-1/4 Depth (in.) 19-1/8 19-1/8
Back of hole must be 1" minimum from back wall
RECIRCULATION INSTALL PLANNING
This hood may be installed in recirculation mode. The charcoal filter is necessary for recirculation installation and is included with the unit.
Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood.
1' = 0.3 m, 1" = 2.5 cm
Cabinet
Add tape to joint
Hood
Wall Cap
Add Insulation and/or Caulk
Wall and Ceiling Framing for Adequate Support This vent hood is heavy and the cabinet
structure needs to support the weight of the loaded insert sleeve. Adequate structural support must be provided in all types of installations.
Ŷ,QVWDOODWLRQZLOOEHHDVLHULIWKHYHQWKRRGLV
installed before the cooktop is installed.
12 49-2000894 Rev. 1
Installation Preparation
INSTALLATION PREPARATION
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Codes or prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
Ŷ Wiring must be 2 wire with ground. ŶIf the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
ŶRoute house wiring as close to the installation
location as possible in the ceiling or wall.
ŶConnect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.
PREPARE FOR CABINET INSTALLATION
NOTE: This bracket must be removed prior to
installation. Remove 2 back (rear) and 2 bottom screws per illustration bellow.
1. Securely press the damper on top of the exhaust opening. Check that the damper opens freely. Attach damper to hood using screws (B) provided.
WARNING
equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.
The improper connection of the
PREPARE HOUSE ELECTRICAL WIRING
The custom cabinet must allow spacing for house wiring to reach junction box located in diagram below. If unit is installed over an island, the wiring must come from ceiling. If power cord is needed, accessory is available.
18" or 24"
Electrical Area
9-1/2"
5-3/4"
or
8-3/4"
2. The hood should be centered left to right over the cooktop.
3. Remove and properly discard the protective plastic wrapping from the hood.
4. The back surface of the hood must be 1" minimum from the back wall. The front surface of the hood must be 3" minimum from the front custom cabinet panel.
5. The custom cabinet should provide for
removal of panels to provide access to the electrical wiring and to the ducting and its connections to the hood in case of any need for servicing or other reasons.
1" = 2.5 cm
49-2000894 Rev. 1 13
Installation
STEP 1
1. Confirm the damper is in place in the hood exhaust opening, see previous page for instructions.
2. Insert the hood into the cabinet opening.
INSTALL THE HOOD
INSTALLATION
ELECTRICAL CONNECTION
1. Remove the electrical junction box cover.
2. Remove the electrical box knockout.
Electrical Box
Knockout with
Strain Relief
3. Fasten with 8 screws [(A), (L) or (D) as needed], 4 in the front and 2 on each side, toward the back of the hood. It is recommended to start with one corner and fasten screws diagonally to ensure unit flushness with cabinet.
4. Once the hood is in place, seal the duct to the hood with duct tape (Do not use screws).
3. Feed the Power Supply Cable through the hole and secure with a strain relief.
4. Attach the white lead of the power supply (A) to the white lead of the range hood (D) with a wire nut. Attach the black lead of the power supply (B) to the black lead of the range hood (C) with a wire nut. Connect the house ground wire under the green grounding screw (E).
E
A
House Wiring
B
C
Hood Wiring
5. Reattach the electrical junction box cover.
D
14 49-2000894 Rev. 1
Installation
INSTALLATION
STEP 2
1. Cut a hole into the soffit for the exhaust duct.
2. Install the vent grill over the exhaust duct.
3. Seal the duct joints with duct tape. Visit GEAppliances.com to order the optional recirculation kit.
In Canada, vision GEAppliances.ca.
90° Angle Boot
RECIRCULATION OPTION (IF USED)
Hood Center Line
6-15/16"
11-1/2"
Soffit Cutout
8” ducting
STEP 3
1. Insert filters, see the Filters section.
2. Check operation of the lights and blower.
3. Finish the custom cabinetry.
FINALIZE INSTALLATION
Filters
1" = 2.5 cm
49-2000894 Rev. 1 15
Installation
MAKE UP AIR TECHNOLOGY
Note to Installers and Inspectors: This product comes equipped with a simple installation feature that limits
maximum CFM levels in order to comply with certain local codes or regulations. This installation method may not be necessary for all installations, please refer to your local codes for further guidelines.
CAUTION
listed below. Failure to do so could result in personal injury or damage to the product.
INSTALLATION
To modify unit (if needed for local codes): 390CFM or 290CFM
By design, the maximum blower speed is greater than 400 CFM. For local codes requiring reduced CFM, modify the wiring as described below:
1. Remove the baffles, see Filters section.
2. Remove the control board box cover.
3. Locate the motor harness plugged into the control board.
4. A -
For a maximum of 390 CFM Unit can operate with 4 speeds (Low, Medium, High, Boost).
1. Disconnect the connector of the blue wire
from the red wire.
2. Connect the 2 red wires together.
3. Cut off the blue unused connector and crimp
the end if desired.
B -
For a maximum of 290 CFM Unit can operate with 3 speeds (Low, Medium, High).
1. Disconnect the connector of the blue wire
from the red wire.
2. Cut off the blue unused connector and crimp
the end if desired.
5. Reattach the control board box cover and install baffles.
Note to Inspectors: To verify this product was installed in either configuration, check motor wiring connections as described above.
Hood must be disconnected from main power prior performing the conversion instructions
Control Board Box Cover
Motor Harness Connector
Red
Blue
Red
Motor Harness
16 49-2000894 Rev. 1
Troubleshooting tips ... Before you call for service
Save time and money! Review the charts on the following pages first and you may not need to call for service.
Problem Possible Cause What To Do
Fan/Light does not operate when button is turned ON
Loud or abnormal airflow noise
Fan fails to circulate air or moves air slower than normal and/or fan is making loud or abnormal airflow noise
Early light failure Light wattage is too high. Replace with correct wattage. Fan automatically turns
on and can not be turned off.
Fan keeps going off and on
Lights not functioning Wrong bulbs are used. Must use GU10
No grease captured in the drip trays
Hood will not work remotely
A house fuse may be blown or a circuit breaker tripped.
Wrong duct size used in installation. This hood requires 8” ducting to perform optimally.
Obstructions in duct work. Make sure nothing is blocking the vent. Make sure
Damper blade on wall or roof cap may not be open.
Metal grease filter and charcoal filter (if present) may be dirty.
Insufficient makeup (replacement) air Sufficient makeup (replacement) air is required for
This is normal. The sensor feature will automatically turn the fan on if
The motor is probably overheating and turning itself off. This can be harmful to the motor.
compatible dimmable bulbs. No grease captured in the drip trays Install the baffles properly making sure the arrows on
Router issues, no wireless signal, etc. For assistance with hood wireless network connectivity, Hood is not connected.
Replace fuse or reset circuit breaker.
Using smaller duct pipe will cause reduced venting. Minimize the duct run length and number of transitions and elbows. GE Appliances service technicians cannot correct this issue if installed improperly.
your wall or roof cap has a blade or door. Make sure damper swings freely. Damper blades may
flip over and will not fully open when this happens. Adjust to original position.
Clean the metal grease filter and replace charcoal filter (if present). See Care and Cleaning of the Vent Hood.
exhausting appliances to operate to rating. Check with local building codes, which may require or strongly advise the use of makeup air. Visit GEAppliances.
com for available makeup air solutions. In Canada, GEAppliances.ca.
cooking temperature becomes too hot. The fan will then turn off when temperatures cool to an appropriate level.
Check to be sure the filters are clean. If off and on cycling continues, call for service.
Visit GEAppliances.com for replacement bulbs. In Canada, GEAppliances.ca.
the sides of the baffles are pointing towards the front of the unit so that the grease openings on the bottom of the baffles are inserted in the drip trays, see the Filters section.
please call 800.220.6899.
TROUBLESHOOTING TIPS
49-2000894 Rev. 1 17
GE Appliances Vented Range Hood Limited Warranty
GEAppliances.com
All warranty service is provided by our Factory Service Centers, or an authorized Customer Care® technician. To schedule service online, visit us at GEAppliances.com/service_and_support/, or call GE Appliances at 800.GE.CARES (800.432.2737). In Canada, visit GEAppliances.ca/en/support/service-request or call 800.561.3344. Please have your serial number and your model number available when calling for service.
Servicing your appliance may require the use of the onboard data port for diagnostics. This gives a GE Appliances factory service technician the ability to quickly diagnose any issues with your appliance and helps GE Appliances improve its products by providing GE Appliances with information on your appliance. If you do not want your appliance data to be sent to GE Appliances, please advise your technician not to submit the data to GE Appliances at the time of service.
For the period of GE Appliances will replace One year
From the date of the original
LIMITED WARRANTY
purchase
What GE Appliances will not cover:
Ŷ Service trips to your home to teach you how to use
the product.
Ŷ Improper installation, delivery, or maintenance. Ŷ Failure of the product if it is abused, misused,
modified, or used for other than the intended purpose or used commercially.
Ŷ Replacement of house fuses or resetting of circuit
breakers.
Ŷ Damage to the product caused by accident, fire,
floods, or acts of God.
Any part of the cooking product which fails due to a defect in materials or workmanship. During this limited one-year warranty, GE Appliances will provide, free of charge, all labor and related service costs to replace the defective part.
Ŷ Damage to finish, such as surface rust, tarnish, or small
blemishes not reported within 48 hours of delivery.
Ŷ Incidental or consequential damage caused by
possible defects with this appliance.
Ŷ Damage caused after delivery. Ŷ Product not accessible to provide required service. Ŷ Service to repair or replace light bulbs, except for LED
lamps.
EXCLUSION OF IMPLIED WARRANTIES
Your sole and exclusive remedy is product repair as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service. In Alaska, the limited warranty excludes the cost of shipping or service calls to your home. warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
In Canada: This warranty is extended to the original purchaser and any succeeding owner for products purchased in Canada for home use within Canada. If the product is located in an area where service by a GE Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location. Some provinces do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights, and you may also have other rights which vary from province to province. To know what your legal rights are, consult your local or provincial consumer affairs office.
Staple your receipt here. Proof of the original purchase
date is needed to obtain service under the warranty.
Garante: GE Appliances, a Haier company Garante en Canadá: MC Commercial
Some states do not allow the exclusion or limitation of incidental or consequential damages. This limited
Louisville, KY 40225 Burlington, ON, L7R 5B6
Extended Warranties: Purchase a GE Appliances extended warranty and learn about special discounts that are available while your warranty is still in effect. You can purchase it online anytime at
In US: geappliances.com/service_and_support/shop-for-extended-service-plans.htm
In Canada: geappliances.ca/en/support/purchase-extended-warranty
or call 800.626.2224 (Canada 866.277.9842) during normal business hours. GE Appliances Service will still be there after your warranty expires.
18 49-2000894 Rev. 1
Loading...