GE THQL1120AFP2, THQL1150, THQL1115AFP2, THQL1140 User Manual

Load Centers and Circuit Breakers
Section Updated 08 / 2016
Q-Line Circuit Breakers– Product Features and Benefits........1-2
PowerMark Gold Load Centers—
Product Features and Benefits ........................................................1-3
PowerMark Gold and Plus Load Centers—
Product Number Guides......................................................................1-4
Q-Line Plug-in Circuit Breakers............................................................1-5
Special Purpose Circuit Breakers ........................................................1-6
PowerMark Gold and Plus Single-Phase Load Centers—
Main Breaker Factory Installed .....................................................1-12
PowerMark Plus
Main Circuit Breakers or Main Lugs Factory Installed .......1-14
PowerMark Gold Load Centers—Specialty Panels...................1-17
PowerMark Gold Meter Socket Load Centers ............................1-18
Field Installed Accessories...................................................................1-24
Wiring Diagrams ......................................................................................1-30
Load Centers and Meter Socket Load Centers—
Knockouts................................................................................................1-37
Three-Phase Load Centers—
Section 1
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-1
Q-Line Circuit Breakers
Reliability and Economy
Section 1Load Centers and Circuit Breakers
Special Purpose Circuit Breakers
—PowerMark Gold Main Circuit Breakers
Copper stabs, tin-plated for corrosion resistance, make the connection reliable and permanent.
—Arc Fault Circuit Interrupter —Dual Function GFCI/AFCI Ground Fault
& Combination Arc Fault Circuit Breaker —Ground Fault with Self-Test Feature —Ground Fault with Equipment Protection —Switching Neutral —HID Lighting Breaker —High Magnetic Breaker —Molded Case Switch
Heat-resistant thermoset cases and covers add stability and structural rigidity.
Trips are easy to spot because handles trip to the center position.
The dedicated calibration screw is cemented (not simply papered over) to prevent shifting. The result is stable calibration for optimum trip performance.
—Surge Arrester —TQ Breaker
At 1/2”, THQP breakers are half the width of standard breakers, permitting the use of smaller load centers that save money and space in both new construction and service upgrades. They feature the same high-performance design, and meet the same stringent standards as other Q­Line breakers. Our 1” THQL will remain the breaker of choice for many contractors. In applica­tions where space and cost are not critical, they’re an excellent choice. But when size and money are driving considerations, THQP breakers are the smart choice.
Enclosed circuit breakers make it easy and efficient to install exterior main breakers.
Maximum protection against all-too-common electrical fires comes from the new technology built into GE’s arc fault circuit interrupters (AFCIs). With its ability to detect and interrupt arcing caused by damaged wire insulation or a frayed extension cord, the AFCI takes home and family protection to a new, higher level.
1-2
BuyLog™Catalog
THQLSURGE surge arresters are easy to install and protect the whole house – comput­ers, fax machines, televi­sions, stereos, VCRs and other sensitive electronic equipment – from destructive surges.
The NEC requires ground fault protection of receptacles outdoors and in garages, bathrooms and spa areas. These ground fault circuit interrupters eliminate the need for separate GFCI receptacles, protect against short circuits and overloads, and prevent shock by detecting very low levels of current leaks and immediately shutting off power to the circuit.
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Load Centers and Circuit Breakers
PowerMark Gold Load Centers
Highest Quality and Convenience
PowerMark Gold load centers lower your costs by making installa­tion faster and easier, increasing application flexibility and reduc­ing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. —UL Listed (Panelboards No. 67) —Suitable for Use as Service Entrance Equipment when installed
in accordance with National Electrical Code —60°C/75°C Conductor Rating —Single phase, 40-225A, 2-42 circuits —Main lug models field convertible to main breaker —Main breaker 22kAIC standard - factory installed —All load centers top or bottom feed —Indoor and outdoor rated enclosures —Indoor fronts combination surface/flush —Copper bus with tin plating standard —Split neutrals extend the full length of the interior for ease of wiring —Entire main lug line converts easily to main breaker —Combination surface/flush front with spring-reinforced pan —Combination slotted/Robertson square-drive screws on neutral,
ground, front and breaker lugs —Front packed in inner carton for added protection —Field installable feed-through lugs up to 200A —Straight-through main wiring —Main breaker is clearly marked and circuit numbers are stamped
on front —Isolated ground bar is available —Compact box maintains optimum wire-bending space
1
2
One-piece interior removes and reinstalls easily
Full-length neutrals are easier to wire, reducing installation time and cost
Minimum 100% neutral terminations
Sturdy copper bus and galvanized box increase durability and reliability
2
Accepts GE Q-Line branch circuit breakers, including GE’s exclusive 1/2" THQPs
Section 1
Main breaker configura­tion allows top or bottom feed without modification
Combination slotted/Robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
2
Packaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site.
Main lug load centers offer an economical solution for subpanels and similar applications. All main lug units 125A and above convert easily to main breaker.
Accessories and Options
—Door lock and handle —Hardware kits —Equipment ground kits —Main breaker retainers —Sub-feed and feed-thru lugs —Neutral kits —Front filler plates —Universal raintight hubs —Handle lock and ties
1
Three-phase PowerMark Plus load centers have aluminum bus with copper breaker
mounting stabs.
2
16 circuit and above.
A complete family of meter socket load centers — ring style and ringless, wide and narrow, meter mains, farm panels and more — deliver specialized solutions for special situations.
The PowerMark Gold line includes a wide range of outdoor as well as indoor units.
GE’s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kAIC ratings, and all the accessories needed to complete the job.
Safety accessories – convenient and easy to install
—THQLSURGE whole house surge protector —Arc fault circuit interrupter breaker, 1- or 2-pole —Ground fault circuit interrupter breaker, 5mA and 30mA —Generator transfer panel – 30A or 60A, indoor or outdoor —GE AC disconnects
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-3
204 C BCU42MT
GE Identification
Type M = Main breaker L = Main lug LM = Convertible
PL = Main lug (Thermoplastic)
Insert for PowerMark Gold CU = Copper Bus
42 = Copper Bus Full 42 circuit panel
Maximum Number 1" Spaces 2, 4, 6…42
Insert for 3-Phase 4-Wire Load Centers
Insert for Specials G or T = Factory installed ground bar B = Bottom feed main breaker FL = Factory installed feed-through lugs
D = Optional door for 6-8 circuit panel. (Doors standard on all units 12 circuits or greater) W = White Front
Enclosure Type C = Combination surface/flush F = Flush S = Surface
R = Outdoor
Bus Ampere Rating 40 = 40 Amps 20 = 200 Amps 70 = 70 Amps 22 = 225 Amps 10 = 100 Amps 30 = 300 Amps
12 = 125 Amps 40 = 400 Amps 15 = 150 Amps 60 = 600 Amps
1*1 15QLHT
GE Identification
Interrupting Rating H = 10kAlC HH = 22kAlC X = 65kAlC
Ground Fault/Arc Fault Circuit Interrupter
AF2 = 1- & 2-pole Combination Arc Fault Circuit Interrupter GFEP = 1- & 2-pole Ground Fault with Equipment Protection Interrupter–30 mA GFT = 1- & 2-pole Ground Fault with Self-Test Feature Interrupter - 5 mA DF = 1-pole Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Interrupter
Poles (1, 2, 3)
Type QL = 1" plug-in QP = 1/2" plug-in QB = 1" bolt-on
Ampere Rating
Voltage 1 = 120/240V
2 = 240V
*Omit character for THQP breakers, which are all 120/240V.
GFT
PowerMark Gold and Plus Load Centers
Product Number Guides
Product Number Guide for Load Centers
(Product number for illustrative purposes only)
Section 1Load Centers and Circuit Breakers
Product Number Guide for Q-Line Plug-in Circuit Breakers
(Product number for illustrative purposes only)
1-4
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Load Centers and Circuit Breakers
Q-Line Plug-in Circuit Breakers
UL Listed (Molded Case Circuit Breakers No. 489) Federal Government Specification Qualified (WC-375B) 60°C / 75°C Conductor Rating Quick Make, Quick Break Box Type Terminals
Section 1
Q-Line Plug-in Circuit Breakers Specifications
Breaker Type Ampere Rating Cu Al
THQP
THQL
THHQL
TXQL
1
Solid or stranded for 14-10 AWG
15-25 14-8 12-8 30-50 8-4 8-4 15-30 14-8 12-8 35-60 8-3 8-3
70-100 6-1/0 4-1/0
110-125 2-2/0 2-2/0
Wire Size AWG/kcmil
THQP130
1
THQL2140
THQP230
THQL32015
THQL1120
Q-Line Plug-in Circuit Breakers
120/240 Vac 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 120/240 Vac
Ampere Product Product Product Product Product Product
Single Pole
Std. Pkg. 5 cartons of 20 5 cartons of 10 5 cartons of 10 5 cartons of 10
Two-Pole
Std. Pkg. 5 cartons of 10 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5
Three-Pole
Std. Pkg. 5 cartons of 3 5 cartons of 3 5 cartons of 3
1
UL Listed as HACR (heating, air conditioning and refrigeration).
2
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting
loads.
3
15-100 amp UL Listed as HACR (heating air conditioning and refrigeration).
4
Required for three-phase and High Leg Delta Systems only.
Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module
Rating Number Number Number Number Number Number
1
2
15
2
20
25 THQP125 THQL1125 THHQL1125 TXQL1125 30 THQP130 THQL1130 THHQL1130 TXQL1130 35 THQP135 THQL1135 THHQL1135 –– 40 THQP140 THQL1140 THHQL1140 –– 45 THQP145 THQL1145 THHQL1145 –– 50 THQP150 THQL1150 THHQL1150 ––
3
: Incorporates Internal Common Trip Bar
15 THQP215 THQL2115 THQL22015 20 THQP220 THQL2120 THQL22020 25 THQP225 THQL2125 THQL22025 30 THQP230 THQL2130 THQL22030 35 THQP235 THQL2135 THQL22035 40 THQP240 THQL2140 THQL22040 45 THQP245 THQL2145 THQL22045 50 THQP250 THQL2150 THQL22050 60 THQL2160 THQL22060 70 THQL2170 THQL22070 80 THQL2180 THQL22080
90 THQL2190 THQL22090 100 THQL21100 THQL22100 110 THQL21110 THHQL21110 –– 125 THQL21125 THHQL21125 ––
3
: Incorporates Internal Common Trip Bar
15 ––THQL32015 THHQL32015 TXQL32015
20 ––THQL32020 THHQL32020 TXQL32020
25 ––THQL32025 THHQL32025 TXQL32025
30 ––THQL32030 THHQL32030 TXQL32030
35 ––THQL32035 THHQL32035
40 ––THQL32040 THHQL32040
45 ––THQL32045 THHQL32045
50 ––THQL32050 THHQL32050
60 ––THQL32060 THHQL32060
70 ––THQL32070 THHQL32070
80 ––THQL32080 THHQL32080
90 ––THQL32090 THHQL32090 – 100 ––THQL32100 THHQL32100
THQP115 THQL1115 THHQL1115 TXQL1115 THQP120 THQL1120 THHQL1120 TXQL1120
10,000AIC 22,000AIC 65,000AIC
4 4 4 4 4 4 4 4 4 4 4 4 4
THHQL2115 THHQL22015 THHQL2120 THHQL22020 THHQL2125 THHQL22025 THHQL2130 THHQL22030 THHQL2135 THHQL22035 THHQL2140 THHQL22040 THHQL2145 THHQL22045 THHQL2150 THHQL22050 THHQL2160 THHQL22060 THHQL2170 THHQL22070 THHQL2180 THHQL22080 THHQL2190 THHQL22090 THHQL21100 THHQL22100
4 4 4 4 4 4 4 4 4 4 4 4 4
TXQL2115 TXQL2120 TXQL2125 TXQL2130 – – – – – – – – –
References:
Accessories Pages 1-24 thru 1-29 Auxiliary Switches and Shunt Trips BuyLog pages 6-40 thru 6-42
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-5
Load Centers and Circuit Breakers
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip
Section 1
Arc Fault
2
UL Listed Arc-Fault Circuit Interrupters No. 1699
Ampere Rating Product Number
10,000 AIC
22,000 AIC
Std. Pkg. 10 Cartons of 1
As of Jan. 1, 2008, 2005 NEC™requires combination AFCI.
1
Combination AFCI compliant with 2008 NEC™and later
2
For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more details on our Arc Fault products.
15 THQL1115AF2 20 THQL1120AF2
15 THHQL1115AF2 20 THHQL1120AF2
1 Pole, 120/240 Volts ac
1
Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
UL Listed (Available December 2014)
Ampere Rating Product Number
10,000 AIC
22,000 AIC
Std. Pkg. 10 Cartons of 1
15 THQL1115DF 20 THQL1120DF
15 THHQL1115DF 20 THHQL1120DF
1 Pole, 120 Volts ac
Ground Fault with Self-Test Feature
cULus Ground Fault Circuit Interrupters UL943 ed5 (5 milliamperes)
1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac
3 3
10,000 AIC
22,000 AIC
3
UL & CSA
Ampere Rating Product Number Product Number
15 THQL1115GFT THQL2115GFT 20 THQL1120GFT THQL2120GFT 25 THQL1125GFT THQL2125GFT 30 THQL1130GFT THQL2130GFT 40 THQL2140GFT 50 THQL2150GFT
15 THHQL1115GFT – 20 THHQL1120GFT – 25 THHQL1125GFT – 30 THHQL1130GFT
PowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold Load Centers (Includes mounting base)
UL Listed.
Description Ampere Rating Product Number Lug Size
Main Circuit Breaker Kits 150 THQMV150D 1-300 (cu), 22,000 AIC 175 THQMV175D 2/0-300
Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is converted to main breaker.
100 THQMV100D 125 THQMV125D
200 THQMV200D 225 THQMV225D
Arc Fault
THQL1115DF
THQL2120GFT
THQMV100D with filler plates
1-6
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Load Centers and Circuit Breakers
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description Product Number
Main Circuit Breaker Kit - Order appropriate THQL TQMH000 10kAIC or THHQL 22kAIC breakers separately
1
Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
Ground Fault with Equipment Protection
cULus Ground Fault Circuit Interrupters No. 943 30 milliampere ground fault trip level
10,000 AIC
Ampere Rating Product Number Product Number
15 THQL1115GFEP THQL2115GFEP 20 THQL1120GFEP THQL2120GFEP 30 THQL1130GFEP THQL2130GFEP
Std. Pkg. 10 Cartons of 1 10 Cartons of 1
1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac
Switching Neutral
UL Listed. 10kAIC RMS symmetrical. Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.
1-Pole Plus Switching Neutral 2-Pole Plus Switching Neutral
Ampere Rating Product Number Product Number
15 THQL21WY15 THQL31WY15 20 THQL21WY20 THQL31WY20 25 THQL21WY25 THQL31WY25 30 THQL21WY30 THQL31WY30
Std. Pkg. 5 cartons of 5 5 cartons of 3
120/240 Volts ac 120/240 Volts ac
"HID" Lighting
UL Listed as HID. HID breakers have been designed to handle the current and voltage spikes that result when gaseous discharge lamps, including fluorescent and HID lamps, are switched on and off.
Ampere Rating Product Number Product Number
10,000 AIC
22,000 AIC
Std. Pkg. 5 cartons of 10 5 cartons of 5
2
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.
15 THQL1115HID 20 THQL1120HID 30 THQL1130HID THQL2130HID
15 THHQL1115HID 20 THHQL1120HID 30 THHQL1130HID THHQL2130HID
1-Pole, 120/240 Volts ac 2-Pole, 120/240 Volts ac
2 2
2 2
THQL2115HID THQL2120HID
THHQL2115HID THHQL2120HID
High Magnetic
UL Listed. 10kAIC RMS symmetrical High short circuit setting suitable for circuits with inherent high-inrush load currents.
Ampere Rating Product Number
15 THQL1115HM 20 THQL1120HM 25 THQL1125HM 30 THQL1130HM 40 THQL1140HM 50 THQL1150HM
Std. Pkg. 5 cartons of 10
1-Pole, 120/240 Volts ac
1
Section 1
TQMH000
THQL21WY30
THQL2120HID
THQL1140HM
Rev. 11/13
Prices and data subject to change without notice
www.geindustrial.com BuyLog™Catalog
1-7
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip
Molded Case Switches
UL Listed Without overload or short circuit protection.
120/240 Volts ac
240 Volts ac
Std. Pkg. 5 cartons of 5 5 cartons of 3
Ampere Rating Product Number Product Number
60 TQL21Y60
100 TQL21Y100
60 TQL22Y60 TQL32Y60
100 TQL22Y100 TQL32Y100
Interlocking Circuit Breakers for use in PowerMark Gold Generator Panels
Two breakers required for interlocking.
Poles Ampere Rating Product Number
2 30 THQL2130GEN 2 60 THQL2160GEN
TQ Circuit Breakers
3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers. 10 kAIC RMS symmetrical
Ampere Rating Product Number Product Number
15 TQ1115 TQ2115 20 TQ1120 TQ2120 30 TQ1130 TQ2130 40 TQ1140 TQ2140 50 TQ1150 TQ2150
Std. Pkg. 1 carton of 10 1 carton of 5
60 TQ2160
THQL 120/240 Vac, with Factory Installed Shunt
# of Ampere 120/240 Vac Poles Rating Wire Range
1 15 (1) 14-8 Cu/12-8 Al 10kA THQL1115ST1 1 20 (1) 14-8 Cu/12-8 Al 10kA THQL1120ST1 1 30 (1) 14-8 Cu/12-8 Al 10kA THQL1130ST1 1 35 (1) 8-3 Cu/8-3 Al 10kA THQL1135ST1 1 40 (1) 8-3 Cu/8-3 Al 10kA THQL1140ST1 1 45 (1) 8-3 Cu/8-3 Al 10kA THQL1145ST1 1 50 (1) 8-3 Cu/8-3 Al 10kA THQL1150ST1 1
Shunt trip requires one additional pole of space.
THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt
# of Ampere 240 Vac Poles Rating Wire Range
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1 2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1 2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1 2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1 2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1 2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1 2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1 2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1 2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1 2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1 2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1 2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1 3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1 3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1 3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1 3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1 3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1 3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1 3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1 3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1 3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1 2
Solid or stranded for 14-10 AWG.
*Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company.
2
2-Pole 3-Pole
1-Pole 2-Pole
1
2
Interrupting Rating Product Number
Interrupting Rating Product Number
1
Section 1Load Centers and Circuit Breakers
TQL21Y100
TQ1120
TQ2120
THQL1130ST1
THQL2120ST1
THQL32020ST1
1-8
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Load Centers and Circuit Breakers
Section 1
PowerMark Gold and Plus Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Product Features
—UL Listed (Panelboards No. 67) —60°/75°C Conductor Rating —Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code —22kAIC RMS symmetrical, Except Where Noted —6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down. —For a listing of CSA Listed load centers, visit geindustrial.com.
TLM2020CCU TPL412R
Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type1Number Cu-Al Ground Kit Number
40 21 41 4Surface Top 1A 14-4 TGK4 (order separately) TL240SCU
70 21 41 4Surface Top 1A 6-3 TGK4 (order separately) TL270SCU
125 42 83 8Combination Top 2A 1-2/0 TGL1 (order separately) TL412C
125 42 83 8Combination Top 2A 1-2/0 TGL1 installed TL412CT
125 42 83 8Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412C
125 42 83 8Thermoplastic Top 2 1-2/0 TGL1 installed TPL412CT
125 6312 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCU
125 6312 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCUD
125 6312 4 12 Flush Top 3A 6-1 TGL2 installed TLM612FCUDG
125 6312 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCU
125 6312 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCUD
125 6312 4 12 Surface Top 3A 6-1 TGL2 installed TLM612SCUDG
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCU
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUD
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUDG
125 8416 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCU
125 8416 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCUD
125 8416 8 16 Surface Top 3A 6-1 TGL2 installed TLM812SCUDG
125 14 6 20 8 24 Combination Top 18 6-2/0 Included
125 14 6 20 8 24 White Combo Top 18 6-2/0 Included
Flush/Surface Bottom
Flush/Surface Bottom
Flush/Surface Bottom
Flush/Surface Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
10
10
This table continued on next page
Indoor NEMA 1
1,8
1,8
1,2,8
1,2,3,8
1,2,3,8
1,2,3,8
TLM1212CCU
TLM1212CCUW
Load Center
1PH
Main Lug
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
7,8
7,8,9
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-9
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Load Center
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number Cu-Al Ground Kit Number
125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TGK24 TLM1612CCU
125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TLK20 TLM1612CCUG
125 24 12 00 24 Combination Top 7 6-2/0 TGK24 and TGK32 TLM2412CCU
125 24 12 00 24 White Combo Top 7 6-2/0 TGK24 and TGK32 TLM2412CCUW
125 24 12 00 24 Combination Top 7 6-2/0 TGK24 and TLK20 TLM2412CCUG
200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCU
200 16 8 32 14 32 White Combo Top 7 6-250 TGK32 TLM1620CCUW
200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCUG
200 20 10 40 18 40 Combination Top 8 6-250 TGK32 TLM2020CCU
200 20 10 40 18 40 White Combo Top 8 6-250 TGK32 TLM2020CCUW
200 20 10 40 18 40 Combination Top 8 6-250 TGK42 TLM2020CCUG
200 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 and TLK32 TLM2420C42
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TLM3220C42
200 32 16 16 6 40 Combination Top 11 6-250 TGK32 TLM3220CCU
200 32 16 16 6 40 White Combo Top 11 6-250 TGK32 TLM3220CCUW
200 40 20 00 40 Combination Top 13 6-250 TGK42 TLM4020CCU
200 40 20 00 40 White Combo Top 13 6-250 TGK42 TLM4020CCUW
200 42 20 00 42 Combination Top 14 1-300 (Cu), TGK42 TLM4220CCU
225 42 20 00 42 Combination Top 14 1-300 (Cu), TGK42 TLM4222CCU
1
No door
2
10 kAIC
3
125 amp maximum branch capacity.
4
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.
5
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.
6
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7
For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
9
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
10
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
Flush/Surface Bottom 2/0-250 (Al) (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom 2/0-300 (Al) (order separately)
Flush/Surface Bottom 2/0-300 (Al) (order separately)
Indoor NEMA 1
1PH
Main Lug
5
7
5
5,9
7
6
6,9
6
6
6,9
6
6
6
6
6,9
6
6,9
6
6
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
1-10
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Section 1
Load Center
1PH
Main Lug
Outdoor NEMA 3R
Main Lugs Factory Installed (TLM units convertible to main breaker), Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
40 21 41 4 Top R1A 14-4 TGK4 (order separately) TL240RCU 70 21 41 4 Top R1A 6-3 TGK4 (order separately) TL270RCU 100 50 00 5Flush Top R41 6-3 TGL1 installed TL510RT 125 42 83 8 Top R1A 1-2/0 TGL1 (order separately) TL412R1 125 42 83 8 Top R1A 1-2/0 TGL1 installed TL412RT1 125 42 83 8 Top R41 1-2/0 TGL1 (order separately) TL412R2 125 42 83 8Thermoplastic Top R1 1-2/0 TGL1 (order separately) TPL412R
125 42 83 8Thermoplastic Top R1 1-2/0 TGL1 installed TPL412RT
125 4312 4 12 Top R2A 6-1 TGK12 (order separately) TLM612RCU 125 8416 8 16 Top R2A 6-1 TGK12 (order separately) TLM812RCU 125 8416 8 16 Top R3A 6-1 TGK12 (order separately) TLM812RCU2 125 14 6 20 8 24 Top R3A 6-2/0 Included TLM1212RCU 125 24 12 00 24 Top R4A 6-2/0 TGK24 (order separately) TLM2412RCU
150 24 12 12 4 30 Top R6A 1-3/0 (Cu), TGK24 (order separately) TLM2415RCU
200 12 6 24 10 24 Top R5A 6-250 TGK24 (order separately) TLM1220RCU 200 16 8 32 14 32 Top R5A 6-250 TGK32 (order separately) TLM1620RCU 200 20 10 40 18 40 Top R6A 6-250 TGK24 (order separately) TLM2020RCU
200 24 12 36 18 42 Top R39 1-250 (Cu), TGK24 (order separately) TLM2420R42
200 32 16 16 6 40 Top R7A 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TLM3220RCU
200 40 20 00 40 Top R8A 6-250 TGK42 (order separately) TLM4020RCU
225 42 20 00 42 Top R8A 1-300 (Cu), TGK42 (order separately) TLM4222RCU
1
40-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
2
10 kAIC.
3
125 amp maximum branch capacity.
4
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.
5
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.
6
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7
For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8
Main and branch breakers are limited to 70 amps.
9
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
1
1
Box (AWG/kcmil) Equipment Product
2,8 2
2
2
Front
Front
Bottom TGK32 (order separately)
Bottom 2/0-3/0 (Al) TGK32 (order separately)
TGK42 (order separately)
Bottom 2/0-250 (Al)
Bottom
Bottom
Bottom 2/0-300 (Al)
2,3
2,3
4 4
5 7,9 5
6
6 6 6
6
6
6
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-11
Load Centers and Circuit Breakers
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker Factory Installed
Section 1
Load Center
Main Breaker
Indoor NEMA 1
Product Features
—UL Listed (Panelboards No. 67) —60°C/75°C Conductor Rating —Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code —22kAIC RMS symmetrical, Except Where Noted —6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down. —For a listing of CSA Listed load centers, visit geindustrial.com.
TM820RCUFLTM2020CCU
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Combination Top 18 4-1/0 Included
100 24 12 0024 Combination Top 7 1-2/0 TGK24, TGK32 and TM2410CCU
100 20 10 0020 Combination Top 6 4-1/0 TGK24 (order separately) TM2010CCU
100 32 16 0032 Combination Top 11 4-1/0 TGK32 (order separately) TM3210CCU
125 12 5 20 8 22 Combination Top 18 1-2/0 Included
125 24 12 0024 Combination Top 7 1-2/0 TGK24 (order separately) TM2412CCU
125 16 8 16 6 24 Combination Top 4 1-2/0 TGK12 (order separately) TM1612CCU
125 16 8 16 6 24 Combination Top 4 1-2/0 TGK24 installed TM1612CCUG
150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TM1615CCU
150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK32 installed TM1615CCUG
Flush/Surface Bottom
Front
Flush/Surface Bottom TLK20 (order separately)
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom TGK24 (order separately)
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
Flush/Surface Bottom 2/0-3/0 (Al)
Front
1
1
TM1210CCU
TM1212CCU
This table continued on next page
1PH
2
2
1-12
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Load Centers and Circuit Breakers
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker Factory Installed
Section 1
Load Center
Main Breaker
Indoor NEMA 1
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
150 32 16 0032 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM3215CCU
150 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 (order separately) TM2415C42
150 32 16 20 10 42 Combination Top 11 1-3/0 (Cu), TGK32 and TLK20 TM3215C42
200 16 8 32 14 32 Combination Top 7 1-250 (Cu), TGK32 (order separately) TM1620CCU
200 16 8 32 14 32 Combination Top 8 1-250 (Cu), TGK32 installed TM1620CCUG
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCU
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK24 (order separately) TM2020CCUW
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUG
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUGW
200 32 16 16 6 40 Combination Top 11 1-250 (Cu), TGK32 (order separately) TM3220CCU
200 40 20 0040 Combination Top 13 1-250 (Cu), TGK42 (order separately) TM4020CCU
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TM3220C42
200 42 20 0042 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4220CCU
225 42 20 0042 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4222CCU
1
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
2
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
3
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
Flush/Surface Bottom 2/0-3/0 (Al)
Flush/Surface Bottom 2/0-3/0 (Al) TLK32 (order separately)
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al) TGK42 (order separately)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al) (order separately)
Flush/Surface Bottom 2/0-300 (Al)
Flush/Surface Bottom 2/0-300 (Al)
1PH
3
3
Load Center
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Top R3A 4-1/0 TGK12 (order separately) TM1210RCU
100 20 10 0030 Top R4 4-1/0 TGK24 (order separately) TM2010RCU 125 12 5 20 8 22 Top R3A 1-2/0 TGK12 (order separately) TM1212RCU
125 24 12 0024 Top R4 1-2/0 TGK24 (order separately) TM2412RCU 150 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM815RCUFL 150 16 8 32 14 32 Top R5 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM1615RCU
150 24 12 12 4 30 Top R6 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM2415RCU
150 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2415R42
150 32 16 0032 Top R7 1-3/0 (Cu), 2/0-3/0 (Al) TGK32 (order separately) TM3215RCU 200 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM820RCUFL 200 20 10 40 18 40 Top R6 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2020RCU
200 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2420R42
200 32 16 16 6 40 Top R7 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM3220RCU 200 40 20 0040 Top R8 1-250 (Cu), 2/0-250 (Al) TGK42 (order separately) TM4020RCU 225 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM822RCUFL 225 42 20 0042 Top R8 1-300 (Cu), 2/0-300 (Al) TGK42 (order separately) TM4222RCU
4
100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
4
TGK24 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK32 (order separately)
Bottom
TGK42 (order separately)
Bottom
1PH
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-13