GE THQL1120AFP2, THQL1150, THQL1115AFP2, THQL1140 User Manual

Page 1
Load Centers and Circuit Breakers
Section Updated 08 / 2016
Q-Line Circuit Breakers– Product Features and Benefits........1-2
PowerMark Gold Load Centers—
Product Features and Benefits ........................................................1-3
PowerMark Gold and Plus Load Centers—
Product Number Guides......................................................................1-4
Q-Line Plug-in Circuit Breakers............................................................1-5
Special Purpose Circuit Breakers ........................................................1-6
PowerMark Gold and Plus Single-Phase Load Centers—
Main Breaker Factory Installed .....................................................1-12
PowerMark Plus
Main Circuit Breakers or Main Lugs Factory Installed .......1-14
PowerMark Gold Load Centers—Specialty Panels...................1-17
PowerMark Gold Meter Socket Load Centers ............................1-18
Field Installed Accessories...................................................................1-24
Wiring Diagrams ......................................................................................1-30
Load Centers and Meter Socket Load Centers—
Knockouts................................................................................................1-37
Three-Phase Load Centers—
Section 1
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-1
Page 2
Q-Line Circuit Breakers
Reliability and Economy
Section 1Load Centers and Circuit Breakers
Special Purpose Circuit Breakers
—PowerMark Gold Main Circuit Breakers
Copper stabs, tin-plated for corrosion resistance, make the connection reliable and permanent.
—Arc Fault Circuit Interrupter —Dual Function GFCI/AFCI Ground Fault
& Combination Arc Fault Circuit Breaker —Ground Fault with Self-Test Feature —Ground Fault with Equipment Protection —Switching Neutral —HID Lighting Breaker —High Magnetic Breaker —Molded Case Switch
Heat-resistant thermoset cases and covers add stability and structural rigidity.
Trips are easy to spot because handles trip to the center position.
The dedicated calibration screw is cemented (not simply papered over) to prevent shifting. The result is stable calibration for optimum trip performance.
—Surge Arrester —TQ Breaker
At 1/2”, THQP breakers are half the width of standard breakers, permitting the use of smaller load centers that save money and space in both new construction and service upgrades. They feature the same high-performance design, and meet the same stringent standards as other Q­Line breakers. Our 1” THQL will remain the breaker of choice for many contractors. In applica­tions where space and cost are not critical, they’re an excellent choice. But when size and money are driving considerations, THQP breakers are the smart choice.
Enclosed circuit breakers make it easy and efficient to install exterior main breakers.
Maximum protection against all-too-common electrical fires comes from the new technology built into GE’s arc fault circuit interrupters (AFCIs). With its ability to detect and interrupt arcing caused by damaged wire insulation or a frayed extension cord, the AFCI takes home and family protection to a new, higher level.
1-2
BuyLog™Catalog
THQLSURGE surge arresters are easy to install and protect the whole house – comput­ers, fax machines, televi­sions, stereos, VCRs and other sensitive electronic equipment – from destructive surges.
The NEC requires ground fault protection of receptacles outdoors and in garages, bathrooms and spa areas. These ground fault circuit interrupters eliminate the need for separate GFCI receptacles, protect against short circuits and overloads, and prevent shock by detecting very low levels of current leaks and immediately shutting off power to the circuit.
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 3
Load Centers and Circuit Breakers
PowerMark Gold Load Centers
Highest Quality and Convenience
PowerMark Gold load centers lower your costs by making installa­tion faster and easier, increasing application flexibility and reduc­ing inventory requirements. At the same time, they deliver obvious and significant advances in design, function and quality. —UL Listed (Panelboards No. 67) —Suitable for Use as Service Entrance Equipment when installed
in accordance with National Electrical Code —60°C/75°C Conductor Rating —Single phase, 40-225A, 2-42 circuits —Main lug models field convertible to main breaker —Main breaker 22kAIC standard - factory installed —All load centers top or bottom feed —Indoor and outdoor rated enclosures —Indoor fronts combination surface/flush —Copper bus with tin plating standard —Split neutrals extend the full length of the interior for ease of wiring —Entire main lug line converts easily to main breaker —Combination surface/flush front with spring-reinforced pan —Combination slotted/Robertson square-drive screws on neutral,
ground, front and breaker lugs —Front packed in inner carton for added protection —Field installable feed-through lugs up to 200A —Straight-through main wiring —Main breaker is clearly marked and circuit numbers are stamped
on front —Isolated ground bar is available —Compact box maintains optimum wire-bending space
1
2
One-piece interior removes and reinstalls easily
Full-length neutrals are easier to wire, reducing installation time and cost
Minimum 100% neutral terminations
Sturdy copper bus and galvanized box increase durability and reliability
2
Accepts GE Q-Line branch circuit breakers, including GE’s exclusive 1/2" THQPs
Section 1
Main breaker configura­tion allows top or bottom feed without modification
Combination slotted/Robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
2
Packaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site.
Main lug load centers offer an economical solution for subpanels and similar applications. All main lug units 125A and above convert easily to main breaker.
Accessories and Options
—Door lock and handle —Hardware kits —Equipment ground kits —Main breaker retainers —Sub-feed and feed-thru lugs —Neutral kits —Front filler plates —Universal raintight hubs —Handle lock and ties
1
Three-phase PowerMark Plus load centers have aluminum bus with copper breaker
mounting stabs.
2
16 circuit and above.
A complete family of meter socket load centers — ring style and ringless, wide and narrow, meter mains, farm panels and more — deliver specialized solutions for special situations.
The PowerMark Gold line includes a wide range of outdoor as well as indoor units.
GE’s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kAIC ratings, and all the accessories needed to complete the job.
Safety accessories – convenient and easy to install
—THQLSURGE whole house surge protector —Arc fault circuit interrupter breaker, 1- or 2-pole —Ground fault circuit interrupter breaker, 5mA and 30mA —Generator transfer panel – 30A or 60A, indoor or outdoor —GE AC disconnects
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-3
Page 4
204 C BCU42MT
GE Identification
Type M = Main breaker L = Main lug LM = Convertible
PL = Main lug (Thermoplastic)
Insert for PowerMark Gold CU = Copper Bus
42 = Copper Bus Full 42 circuit panel
Maximum Number 1" Spaces 2, 4, 6…42
Insert for 3-Phase 4-Wire Load Centers
Insert for Specials G or T = Factory installed ground bar B = Bottom feed main breaker FL = Factory installed feed-through lugs
D = Optional door for 6-8 circuit panel. (Doors standard on all units 12 circuits or greater) W = White Front
Enclosure Type C = Combination surface/flush F = Flush S = Surface
R = Outdoor
Bus Ampere Rating 40 = 40 Amps 20 = 200 Amps 70 = 70 Amps 22 = 225 Amps 10 = 100 Amps 30 = 300 Amps
12 = 125 Amps 40 = 400 Amps 15 = 150 Amps 60 = 600 Amps
1*1 15QLHT
GE Identification
Interrupting Rating H = 10kAlC HH = 22kAlC X = 65kAlC
Ground Fault/Arc Fault Circuit Interrupter
AF2 = 1- & 2-pole Combination Arc Fault Circuit Interrupter GFEP = 1- & 2-pole Ground Fault with Equipment Protection Interrupter–30 mA GFT = 1- & 2-pole Ground Fault with Self-Test Feature Interrupter - 5 mA DF = 1-pole Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Interrupter
Poles (1, 2, 3)
Type QL = 1" plug-in QP = 1/2" plug-in QB = 1" bolt-on
Ampere Rating
Voltage 1 = 120/240V
2 = 240V
*Omit character for THQP breakers, which are all 120/240V.
GFT
PowerMark Gold and Plus Load Centers
Product Number Guides
Product Number Guide for Load Centers
(Product number for illustrative purposes only)
Section 1Load Centers and Circuit Breakers
Product Number Guide for Q-Line Plug-in Circuit Breakers
(Product number for illustrative purposes only)
1-4
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 5
Load Centers and Circuit Breakers
Q-Line Plug-in Circuit Breakers
UL Listed (Molded Case Circuit Breakers No. 489) Federal Government Specification Qualified (WC-375B) 60°C / 75°C Conductor Rating Quick Make, Quick Break Box Type Terminals
Section 1
Q-Line Plug-in Circuit Breakers Specifications
Breaker Type Ampere Rating Cu Al
THQP
THQL
THHQL
TXQL
1
Solid or stranded for 14-10 AWG
15-25 14-8 12-8 30-50 8-4 8-4 15-30 14-8 12-8 35-60 8-3 8-3
70-100 6-1/0 4-1/0
110-125 2-2/0 2-2/0
Wire Size AWG/kcmil
THQP130
1
THQL2140
THQP230
THQL32015
THQL1120
Q-Line Plug-in Circuit Breakers
120/240 Vac 120/240 Vac 120/240 Vac 240 Vac 120/240 Vac 240 Vac 120/240 Vac
Ampere Product Product Product Product Product Product
Single Pole
Std. Pkg. 5 cartons of 20 5 cartons of 10 5 cartons of 10 5 cartons of 10
Two-Pole
Std. Pkg. 5 cartons of 10 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5 5 cartons of 5
Three-Pole
Std. Pkg. 5 cartons of 3 5 cartons of 3 5 cartons of 3
1
UL Listed as HACR (heating, air conditioning and refrigeration).
2
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting
loads.
3
15-100 amp UL Listed as HACR (heating air conditioning and refrigeration).
4
Required for three-phase and High Leg Delta Systems only.
Type THQP 1/2-inch Module Type THQL 1-inch Module Type THHQL 1-inch Module Type TXQL 1-inch Module
Rating Number Number Number Number Number Number
1
2
15
2
20
25 THQP125 THQL1125 THHQL1125 TXQL1125 30 THQP130 THQL1130 THHQL1130 TXQL1130 35 THQP135 THQL1135 THHQL1135 –– 40 THQP140 THQL1140 THHQL1140 –– 45 THQP145 THQL1145 THHQL1145 –– 50 THQP150 THQL1150 THHQL1150 ––
3
: Incorporates Internal Common Trip Bar
15 THQP215 THQL2115 THQL22015 20 THQP220 THQL2120 THQL22020 25 THQP225 THQL2125 THQL22025 30 THQP230 THQL2130 THQL22030 35 THQP235 THQL2135 THQL22035 40 THQP240 THQL2140 THQL22040 45 THQP245 THQL2145 THQL22045 50 THQP250 THQL2150 THQL22050 60 THQL2160 THQL22060 70 THQL2170 THQL22070 80 THQL2180 THQL22080
90 THQL2190 THQL22090 100 THQL21100 THQL22100 110 THQL21110 THHQL21110 –– 125 THQL21125 THHQL21125 ––
3
: Incorporates Internal Common Trip Bar
15 ––THQL32015 THHQL32015 TXQL32015
20 ––THQL32020 THHQL32020 TXQL32020
25 ––THQL32025 THHQL32025 TXQL32025
30 ––THQL32030 THHQL32030 TXQL32030
35 ––THQL32035 THHQL32035
40 ––THQL32040 THHQL32040
45 ––THQL32045 THHQL32045
50 ––THQL32050 THHQL32050
60 ––THQL32060 THHQL32060
70 ––THQL32070 THHQL32070
80 ––THQL32080 THHQL32080
90 ––THQL32090 THHQL32090 – 100 ––THQL32100 THHQL32100
THQP115 THQL1115 THHQL1115 TXQL1115 THQP120 THQL1120 THHQL1120 TXQL1120
10,000AIC 22,000AIC 65,000AIC
4 4 4 4 4 4 4 4 4 4 4 4 4
THHQL2115 THHQL22015 THHQL2120 THHQL22020 THHQL2125 THHQL22025 THHQL2130 THHQL22030 THHQL2135 THHQL22035 THHQL2140 THHQL22040 THHQL2145 THHQL22045 THHQL2150 THHQL22050 THHQL2160 THHQL22060 THHQL2170 THHQL22070 THHQL2180 THHQL22080 THHQL2190 THHQL22090 THHQL21100 THHQL22100
4 4 4 4 4 4 4 4 4 4 4 4 4
TXQL2115 TXQL2120 TXQL2125 TXQL2130 – – – – – – – – –
References:
Accessories Pages 1-24 thru 1-29 Auxiliary Switches and Shunt Trips BuyLog pages 6-40 thru 6-42
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-5
Page 6
Load Centers and Circuit Breakers
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip
Section 1
Arc Fault
2
UL Listed Arc-Fault Circuit Interrupters No. 1699
Ampere Rating Product Number
10,000 AIC
22,000 AIC
Std. Pkg. 10 Cartons of 1
As of Jan. 1, 2008, 2005 NEC™requires combination AFCI.
1
Combination AFCI compliant with 2008 NEC™and later
2
For 2-Pole shared neutral applications use two 1-pole circuit breakers with a handle tie. See DET-719 for more details on our Arc Fault products.
15 THQL1115AF2 20 THQL1120AF2
15 THHQL1115AF2 20 THHQL1120AF2
1 Pole, 120/240 Volts ac
1
Dual Function GFCI/AFCI Ground Fault & Combination Arc Fault Circuit Breaker
UL Listed (Available December 2014)
Ampere Rating Product Number
10,000 AIC
22,000 AIC
Std. Pkg. 10 Cartons of 1
15 THQL1115DF 20 THQL1120DF
15 THHQL1115DF 20 THHQL1120DF
1 Pole, 120 Volts ac
Ground Fault with Self-Test Feature
cULus Ground Fault Circuit Interrupters UL943 ed5 (5 milliamperes)
1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac
3 3
10,000 AIC
22,000 AIC
3
UL & CSA
Ampere Rating Product Number Product Number
15 THQL1115GFT THQL2115GFT 20 THQL1120GFT THQL2120GFT 25 THQL1125GFT THQL2125GFT 30 THQL1130GFT THQL2130GFT 40 THQL2140GFT 50 THQL2150GFT
15 THHQL1115GFT – 20 THHQL1120GFT – 25 THHQL1125GFT – 30 THHQL1130GFT
PowerMark Gold Main Circuit Breakers for use with 150A-225A PowerMark Gold Load Centers (Includes mounting base)
UL Listed.
Description Ampere Rating Product Number Lug Size
Main Circuit Breaker Kits 150 THQMV150D 1-300 (cu), 22,000 AIC 175 THQMV175D 2/0-300
Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is converted to main breaker.
100 THQMV100D 125 THQMV125D
200 THQMV200D 225 THQMV225D
Arc Fault
THQL1115DF
THQL2120GFT
THQMV100D with filler plates
1-6
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 7
Load Centers and Circuit Breakers
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description Product Number
Main Circuit Breaker Kit - Order appropriate THQL TQMH000 10kAIC or THHQL 22kAIC breakers separately
1
Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
Ground Fault with Equipment Protection
cULus Ground Fault Circuit Interrupters No. 943 30 milliampere ground fault trip level
10,000 AIC
Ampere Rating Product Number Product Number
15 THQL1115GFEP THQL2115GFEP 20 THQL1120GFEP THQL2120GFEP 30 THQL1130GFEP THQL2130GFEP
Std. Pkg. 10 Cartons of 1 10 Cartons of 1
1-Pole, 120 Volts ac 2-Pole, 120/240 Volts ac
Switching Neutral
UL Listed. 10kAIC RMS symmetrical. Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.
1-Pole Plus Switching Neutral 2-Pole Plus Switching Neutral
Ampere Rating Product Number Product Number
15 THQL21WY15 THQL31WY15 20 THQL21WY20 THQL31WY20 25 THQL21WY25 THQL31WY25 30 THQL21WY30 THQL31WY30
Std. Pkg. 5 cartons of 5 5 cartons of 3
120/240 Volts ac 120/240 Volts ac
"HID" Lighting
UL Listed as HID. HID breakers have been designed to handle the current and voltage spikes that result when gaseous discharge lamps, including fluorescent and HID lamps, are switched on and off.
Ampere Rating Product Number Product Number
10,000 AIC
22,000 AIC
Std. Pkg. 5 cartons of 10 5 cartons of 5
2
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.
15 THQL1115HID 20 THQL1120HID 30 THQL1130HID THQL2130HID
15 THHQL1115HID 20 THHQL1120HID 30 THHQL1130HID THHQL2130HID
1-Pole, 120/240 Volts ac 2-Pole, 120/240 Volts ac
2 2
2 2
THQL2115HID THQL2120HID
THHQL2115HID THHQL2120HID
High Magnetic
UL Listed. 10kAIC RMS symmetrical High short circuit setting suitable for circuits with inherent high-inrush load currents.
Ampere Rating Product Number
15 THQL1115HM 20 THQL1120HM 25 THQL1125HM 30 THQL1130HM 40 THQL1140HM 50 THQL1150HM
Std. Pkg. 5 cartons of 10
1-Pole, 120/240 Volts ac
1
Section 1
TQMH000
THQL21WY30
THQL2120HID
THQL1140HM
Rev. 11/13
Prices and data subject to change without notice
www.geindustrial.com BuyLog™Catalog
1-7
Page 8
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating Box Type Terminals Quick-Make, Quick-Break Multi-pole Breakers Incorporate Internal Common Trip
Molded Case Switches
UL Listed Without overload or short circuit protection.
120/240 Volts ac
240 Volts ac
Std. Pkg. 5 cartons of 5 5 cartons of 3
Ampere Rating Product Number Product Number
60 TQL21Y60
100 TQL21Y100
60 TQL22Y60 TQL32Y60
100 TQL22Y100 TQL32Y100
Interlocking Circuit Breakers for use in PowerMark Gold Generator Panels
Two breakers required for interlocking.
Poles Ampere Rating Product Number
2 30 THQL2130GEN 2 60 THQL2160GEN
TQ Circuit Breakers
3/4" UL Classified Circuit Breakers for use in *Square D **QO Load Centers. 10 kAIC RMS symmetrical
Ampere Rating Product Number Product Number
15 TQ1115 TQ2115 20 TQ1120 TQ2120 30 TQ1130 TQ2130 40 TQ1140 TQ2140 50 TQ1150 TQ2150
Std. Pkg. 1 carton of 10 1 carton of 5
60 TQ2160
THQL 120/240 Vac, with Factory Installed Shunt
# of Ampere 120/240 Vac Poles Rating Wire Range
1 15 (1) 14-8 Cu/12-8 Al 10kA THQL1115ST1 1 20 (1) 14-8 Cu/12-8 Al 10kA THQL1120ST1 1 30 (1) 14-8 Cu/12-8 Al 10kA THQL1130ST1 1 35 (1) 8-3 Cu/8-3 Al 10kA THQL1135ST1 1 40 (1) 8-3 Cu/8-3 Al 10kA THQL1140ST1 1 45 (1) 8-3 Cu/8-3 Al 10kA THQL1145ST1 1 50 (1) 8-3 Cu/8-3 Al 10kA THQL1150ST1 1
Shunt trip requires one additional pole of space.
THQL 120/240 Vac, Internal Common Trip with Factory Installed Shunt
# of Ampere 240 Vac Poles Rating Wire Range
2 15 14-8 Cu/12-8 Al 10kA THQL2115ST1 2 20 14-8 Cu/12-8 Al 10kA THQL2120ST1 2 30 14-8 Cu/12-8 Al 10kA THQL2130ST1 2 35 8-3 Cu/8-3 Al 10kA THQL2135ST1 2 40 8-3 Cu/8-3 Al 10kA THQL2140ST1 2 45 8-3 Cu/8-3 Al 10kA THQL2145ST1 2 50 8-3 Cu/8-3 Al 10kA THQL2150ST1 2 60 8-3 Cu/8-3 Al 10kA THQL2160ST1 2 70 6-1/0 Cu/4-1/0 Al 10kA THQL2170ST1 2 80 6-1/0 Cu/4-1/0 Al 10kA THQL2180ST1 2 90 6-1/0 Cu/4-1/0 Al 10kA THQL2190ST1 2 100 6-1/0 Cu/4-1/0 Al 10kA THQL21100ST1 3 20 14-8 Cu/12-8 Al 10kA THQL32020ST1 3 30 14-8 Cu/12-8 Al 10kA THQL32030ST1 3 40 8-3 Cu/8-3 Al 10kA THQL32040ST1 3 50 8-3 Cu/8-3 Al 10kA THQL32050ST1 3 60 8-3 Cu/8-3 Al 10kA THQL32060ST1 3 70 6-1/0 Cu/4-1/0 Al 10kA THQL32070ST1 3 80 6-1/0 Cu/4-1/0 Al 10kA THQL32080ST1 3 90 6-1/0 Cu/4-1/0 Al 10kA THQL32090ST1 3 100 6-1/0 Cu/4-1/0 Al 10kA THQL32100ST1 2
Solid or stranded for 14-10 AWG.
*Square D is a registered trademark of SNA Holdings, Inc. **QO is a registered trademark of the Square D Company.
2
2-Pole 3-Pole
1-Pole 2-Pole
1
2
Interrupting Rating Product Number
Interrupting Rating Product Number
1
Section 1Load Centers and Circuit Breakers
TQL21Y100
TQ1120
TQ2120
THQL1130ST1
THQL2120ST1
THQL32020ST1
1-8
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 9
Load Centers and Circuit Breakers
Section 1
PowerMark Gold and Plus Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Product Features
—UL Listed (Panelboards No. 67) —60°/75°C Conductor Rating —Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code —22kAIC RMS symmetrical, Except Where Noted —6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down. —For a listing of CSA Listed load centers, visit geindustrial.com.
TLM2020CCU TPL412R
Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type1Number Cu-Al Ground Kit Number
40 21 41 4Surface Top 1A 14-4 TGK4 (order separately) TL240SCU
70 21 41 4Surface Top 1A 6-3 TGK4 (order separately) TL270SCU
125 42 83 8Combination Top 2A 1-2/0 TGL1 (order separately) TL412C
125 42 83 8Combination Top 2A 1-2/0 TGL1 installed TL412CT
125 42 83 8Thermoplastic Top 2 1-2/0 TGL1 (order separately) TPL412C
125 42 83 8Thermoplastic Top 2 1-2/0 TGL1 installed TPL412CT
125 6312 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCU
125 6312 4 12 Flush Top 3A 6-1 TGL2 (order separately) TLM612FCUD
125 6312 4 12 Flush Top 3A 6-1 TGL2 installed TLM612FCUDG
125 6312 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCU
125 6312 4 12 Surface Top 3A 6-1 TGL2 (order separately) TLM612SCUD
125 6312 4 12 Surface Top 3A 6-1 TGL2 installed TLM612SCUDG
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCU
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUD
125 8416 8 16 Flush Top 3A 6-1 TGL2 (order separately) TLM812FCUDG
125 8416 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCU
125 8416 8 16 Surface Top 3A 6-1 TGL2 (order separately) TLM812SCUD
125 8416 8 16 Surface Top 3A 6-1 TGL2 installed TLM812SCUDG
125 14 6 20 8 24 Combination Top 18 6-2/0 Included
125 14 6 20 8 24 White Combo Top 18 6-2/0 Included
Flush/Surface Bottom
Flush/Surface Bottom
Flush/Surface Bottom
Flush/Surface Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
10
10
This table continued on next page
Indoor NEMA 1
1,8
1,8
1,2,8
1,2,3,8
1,2,3,8
1,2,3,8
TLM1212CCU
TLM1212CCUW
Load Center
1PH
Main Lug
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
4,8
7,8
7,8,9
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-9
Page 10
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Section 1
Load Center
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Main Lugs Factory Installed (TLM units convertible to main breaker), Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Feed Type Number Cu-Al Ground Kit Number
125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TGK24 TLM1612CCU
125 16 8 16 6 24 Combination Top 4 6-2/0 TGK12 and TLK20 TLM1612CCUG
125 24 12 00 24 Combination Top 7 6-2/0 TGK24 and TGK32 TLM2412CCU
125 24 12 00 24 White Combo Top 7 6-2/0 TGK24 and TGK32 TLM2412CCUW
125 24 12 00 24 Combination Top 7 6-2/0 TGK24 and TLK20 TLM2412CCUG
200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCU
200 16 8 32 14 32 White Combo Top 7 6-250 TGK32 TLM1620CCUW
200 16 8 32 14 32 Combination Top 7 6-250 TGK32 TLM1620CCUG
200 20 10 40 18 40 Combination Top 8 6-250 TGK32 TLM2020CCU
200 20 10 40 18 40 White Combo Top 8 6-250 TGK32 TLM2020CCUW
200 20 10 40 18 40 Combination Top 8 6-250 TGK42 TLM2020CCUG
200 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 and TLK32 TLM2420C42
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TLM3220C42
200 32 16 16 6 40 Combination Top 11 6-250 TGK32 TLM3220CCU
200 32 16 16 6 40 White Combo Top 11 6-250 TGK32 TLM3220CCUW
200 40 20 00 40 Combination Top 13 6-250 TGK42 TLM4020CCU
200 40 20 00 40 White Combo Top 13 6-250 TGK42 TLM4020CCUW
200 42 20 00 42 Combination Top 14 1-300 (Cu), TGK42 TLM4220CCU
225 42 20 00 42 Combination Top 14 1-300 (Cu), TGK42 TLM4222CCU
1
No door
2
10 kAIC
3
125 amp maximum branch capacity.
4
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp max.
5
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-5.
6
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7
For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
9
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
10
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom installed
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
Flush/Surface Bottom 2/0-250 (Al) (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom (order separately)
Flush/Surface Bottom 2/0-300 (Al) (order separately)
Flush/Surface Bottom 2/0-300 (Al) (order separately)
Indoor NEMA 1
1PH
Main Lug
5
7
5
5,9
7
6
6,9
6
6
6,9
6
6
6
6
6,9
6
6,9
6
6
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
1-10
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 11
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Section 1
Load Center
1PH
Main Lug
Outdoor NEMA 3R
Main Lugs Factory Installed (TLM units convertible to main breaker), Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
40 21 41 4 Top R1A 14-4 TGK4 (order separately) TL240RCU 70 21 41 4 Top R1A 6-3 TGK4 (order separately) TL270RCU 100 50 00 5Flush Top R41 6-3 TGL1 installed TL510RT 125 42 83 8 Top R1A 1-2/0 TGL1 (order separately) TL412R1 125 42 83 8 Top R1A 1-2/0 TGL1 installed TL412RT1 125 42 83 8 Top R41 1-2/0 TGL1 (order separately) TL412R2 125 42 83 8Thermoplastic Top R1 1-2/0 TGL1 (order separately) TPL412R
125 42 83 8Thermoplastic Top R1 1-2/0 TGL1 installed TPL412RT
125 4312 4 12 Top R2A 6-1 TGK12 (order separately) TLM612RCU 125 8416 8 16 Top R2A 6-1 TGK12 (order separately) TLM812RCU 125 8416 8 16 Top R3A 6-1 TGK12 (order separately) TLM812RCU2 125 14 6 20 8 24 Top R3A 6-2/0 Included TLM1212RCU 125 24 12 00 24 Top R4A 6-2/0 TGK24 (order separately) TLM2412RCU
150 24 12 12 4 30 Top R6A 1-3/0 (Cu), TGK24 (order separately) TLM2415RCU
200 12 6 24 10 24 Top R5A 6-250 TGK24 (order separately) TLM1220RCU 200 16 8 32 14 32 Top R5A 6-250 TGK32 (order separately) TLM1620RCU 200 20 10 40 18 40 Top R6A 6-250 TGK24 (order separately) TLM2020RCU
200 24 12 36 18 42 Top R39 1-250 (Cu), TGK24 (order separately) TLM2420R42
200 32 16 16 6 40 Top R7A 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TLM3220RCU
200 40 20 00 40 Top R8A 6-250 TGK42 (order separately) TLM4020RCU
225 42 20 00 42 Top R8A 1-300 (Cu), TGK42 (order separately) TLM4222RCU
1
40-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
2
10 kAIC.
3
125 amp maximum branch capacity.
4
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.
5
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.
6
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7
For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8
Main and branch breakers are limited to 70 amps.
9
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
1
1
Box (AWG/kcmil) Equipment Product
2,8 2
2
2
Front
Front
Bottom TGK32 (order separately)
Bottom 2/0-3/0 (Al) TGK32 (order separately)
TGK42 (order separately)
Bottom 2/0-250 (Al)
Bottom
Bottom
Bottom 2/0-300 (Al)
2,3
2,3
4 4
5 7,9 5
6
6 6 6
6
6
6
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-11
Page 12
Load Centers and Circuit Breakers
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker Factory Installed
Section 1
Load Center
Main Breaker
Indoor NEMA 1
Product Features
—UL Listed (Panelboards No. 67) —60°C/75°C Conductor Rating —Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code —22kAIC RMS symmetrical, Except Where Noted —6-42 circuit devices UL Listed for bottom mounted lugs by
installing complete unit (box, interior and front) upside down. —For a listing of CSA Listed load centers, visit geindustrial.com.
TM820RCUFLTM2020CCU
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Combination Top 18 4-1/0 Included
100 24 12 0024 Combination Top 7 1-2/0 TGK24, TGK32 and TM2410CCU
100 20 10 0020 Combination Top 6 4-1/0 TGK24 (order separately) TM2010CCU
100 32 16 0032 Combination Top 11 4-1/0 TGK32 (order separately) TM3210CCU
125 12 5 20 8 22 Combination Top 18 1-2/0 Included
125 24 12 0024 Combination Top 7 1-2/0 TGK24 (order separately) TM2412CCU
125 16 8 16 6 24 Combination Top 4 1-2/0 TGK12 (order separately) TM1612CCU
125 16 8 16 6 24 Combination Top 4 1-2/0 TGK24 installed TM1612CCUG
150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TM1615CCU
150 16 8 32 14 32 Combination Top 7 1-3/0 (Cu), TGK32 installed TM1615CCUG
Flush/Surface Bottom
Front
Flush/Surface Bottom TLK20 (order separately)
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom TGK24 (order separately)
Front
Flush/Surface Bottom
Front
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
Flush/Surface Bottom 2/0-3/0 (Al)
Front
1
1
TM1210CCU
TM1212CCU
This table continued on next page
1PH
2
2
1-12
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 13
Load Centers and Circuit Breakers
PowerMark Gold and Plus Main Breaker Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Breaker Factory Installed
Section 1
Load Center
Main Breaker
Indoor NEMA 1
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
150 32 16 0032 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM3215CCU
150 24 12 36 18 42 Combination Top 9 1-3/0 (Cu), TGK24 (order separately) TM2415C42
150 32 16 20 10 42 Combination Top 11 1-3/0 (Cu), TGK32 and TLK20 TM3215C42
200 16 8 32 14 32 Combination Top 7 1-250 (Cu), TGK32 (order separately) TM1620CCU
200 16 8 32 14 32 Combination Top 8 1-250 (Cu), TGK32 installed TM1620CCUG
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCU
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK24 (order separately) TM2020CCUW
200 20 10 40 18 40 Combination Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUG
200 20 10 40 18 40 White Combo Top 8 1-250 (Cu), TGK32 (order separately) TM2020CCUGW
200 32 16 16 6 40 Combination Top 11 1-250 (Cu), TGK32 (order separately) TM3220CCU
200 40 20 0040 Combination Top 13 1-250 (Cu), TGK42 (order separately) TM4020CCU
200 32 16 20 8 42 Combination Top 11 1-250 (Cu), TGK32 and TLK20 TM3220C42
200 42 20 0042 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4220CCU
225 42 20 0042 Combination Top 14 1-300 (Cu), TGK42 (order separately) TM4222CCU
1
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
2
No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required.
3
Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590)
Flush/Surface Bottom 2/0-3/0 (Al)
Flush/Surface Bottom 2/0-3/0 (Al) TLK32 (order separately)
Flush/Surface Bottom 2/0-3/0 (Al) (order separately)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al) TGK42 (order separately)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al)
Flush/Surface Bottom 2/0-250 (Al) (order separately)
Flush/Surface Bottom 2/0-300 (Al)
Flush/Surface Bottom 2/0-300 (Al)
1PH
3
3
Load Center
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 12 5 20 8 22 Top R3A 4-1/0 TGK12 (order separately) TM1210RCU
100 20 10 0030 Top R4 4-1/0 TGK24 (order separately) TM2010RCU 125 12 5 20 8 22 Top R3A 1-2/0 TGK12 (order separately) TM1212RCU
125 24 12 0024 Top R4 1-2/0 TGK24 (order separately) TM2412RCU 150 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM815RCUFL 150 16 8 32 14 32 Top R5 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM1615RCU
150 24 12 12 4 30 Top R6 1-3/0 (Cu), 2/0-3/0 (Al) TGK24 (order separately) TM2415RCU
150 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2415R42
150 32 16 0032 Top R7 1-3/0 (Cu), 2/0-3/0 (Al) TGK32 (order separately) TM3215RCU 200 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM820RCUFL 200 20 10 40 18 40 Top R6 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2020RCU
200 24 12 36 18 42 Top R39 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM2420R42
200 32 16 16 6 40 Top R7 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TM3220RCU 200 40 20 0040 Top R8 1-250 (Cu), 2/0-250 (Al) TGK42 (order separately) TM4020RCU 225 8416 6 16 Top R5 1-250 (Cu), 2/0-250 (Al) TGK24 (order separately) TM822RCUFL 225 42 20 0042 Top R8 1-300 (Cu), 2/0-300 (Al) TGK42 (order separately) TM4222RCU
4
100-225 amp devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
4
TGK24 (order separately)
TGK24 (order separately)
TGK32 (order separately)
TGK32 (order separately)
Bottom
TGK42 (order separately)
Bottom
1PH
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-13
Page 14
Load Centers and Circuit Breakers
PowerMark Plus™Load Centers
Three-Phase, Four-Wire, 208Y/120 Vac
Main Lugs Factory Installed
2
Section 1
Load Center
Indoor NEMA 1
Product Features
—UL Listed (Panelboards No. 67) —60°/75°C Conductor Rating —Suitable for Use as Service Entrance Equipment when Installed
in Accordance with the National Electrical Code —22kAIC RMS symmetrical Short-circuit Rating Standard —Bottom feed models available where noted with a “B” suffix. —For a listing of CSA Listed load centers, visit geindustrial.com. —Copper breaker mounting stabs with aluminum bus
1
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 12 6412 Combination Top 4 6-2/0 TGK12 (order separately) TL12412C
150 18 8618 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL18415C
150 24 12 8 24 Combination Top 7 1-3/0 (Cu), TGK24 (order separately) TL24415C
200 18 8618 Combination Top 8 1-250 (Cu), TGK32 (order separately) TL18420C
200 30 14 10 30 Combination Top 11 1-250 (Cu), TGK32 (order separately) TL30420C
200 42 20 14 42 Combination Top 13 1-250 (Cu), TGK42 (order separately) TL42420C
225 30 14 10 30 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL30422C
225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TL42422C
1
Three-phase PowerMark Plus load centers have aluminum bus with copper breaker mounting stabs, providing copper-to-copper contact at breaker stabs.
2
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
3
Alternate main breaker: 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
4
Not suitable for use as service entrance equipment .
Flush/Surface Bottom TGK24 (order separately)
Front
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
Flush/Surface Bottom 2/0-3/0 (Al) TGK32 (order separately)
Front
Flush/Surface Bottom 2/0-250 (Al)
Front
Flush/Surface Bottom 2/0-250 (Al)
Front
Flush/Surface Bottom 2/0-250 (Al)
Front
Flush/Surface Bottom 2/0-300 (Al)
Front
Flush/Surface Bottom 2/0-300 (Al)
Front
3PH
Main Lugs
3
3
3
3
3
4
4
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
1-14
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 15
Load Centers and Circuit Breakers
PowerMark Plus™Load Centers
Three-Phase, Four-Wire, 208Y/120Vac
Main Circuit Breaker or Main Lugs Factory Installed
Section 1
Load Center
3PH
Main Lugs
Outdoor NEMA 3R
Main Lugs Factory Installed
1
TM24420CB
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
125 12 6412 Top R3 6-2/0 TGK12 (order separately) TL12412R
150 18 8618 Top R4 1-3/0 (Cu), TGK24 (order separately) TL18415R
150 24 12 8 24 Top R4 1-3/0 (Cu), TGK24 (order separately) TL24415R
200 18 8618 Top R4 1-250 (Cu), TGK32 (order separately) TL18420R
200 30 14 10 30 Top R6 1-250 (Cu), TGK32 (order separately) TL30420R
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TL42420R
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TL42422R
1
Also UL Listed for three-phase, four-wire 240/120 Volts ac delta and three-phase, three-wire 240 Volts ac branch breakers installed.
2
Alternate main breaker 100 Amp max. THQL (10kAIC), THHQL (22kAIC) three-pole, use retainer THQLRK. See page 1-28.
3
Not suitable for use as service entrance equipment .
Main Breaker Factory Installed
4
2/0-3/0 (Al) TGK32 (order separately)
2/0-3/0 (Al) TGK32 (order separately)
2/0-250 (Al)
2/0-250 (Al)
2/0-250 (Al)
2/0-300 (Al)
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
100 12 6412 Combination Top 6 6-1/0 (Cu), TGK12 (order separately) TM12410C
100 18 8618 Combination Top 6 6-1/0 (Cu), TGK24 (order separately) TM18410C
125 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30412C
125 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30412CB
150 24 12 8 24 Combination Top 11 1-3/0 (Cu), TGL1, TGL2, TGL20,TNG3, TM24415C
150 24 12 8 24 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM24415CB
150 30 14 10 30 Combination Top 11 1-3/0 (Cu), TGK32 (order separately) TM30415C
150 30 14 10 30 Combination Bottom 11 1-3/0 (Cu), TGK32 (order separately) TM30415CB
150 42 20 14 42 Combination Top 13 1-3/0 (Cu), TGK42 (order separately) TM42415C
150 42 20 14 42 Combination Bottom 13 1-3/0 (Cu), TGK42 (order separately) TM42415CB
200 24 12 8 24 Combination Top 11 1-300 (Cu), TGK32 (order separately) TM24420C
200 24 12 8 24 Combination Bottom 11 1-300 (Cu), TGK32 (order separately) TM24420CB
4
Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.
5
100 Amp indoor devices UL listed for bottom-feed by installing complete unit upside-down.
Flush/Surface Bottom 4-1/0 (Al) TGK24 (order separately)
Front
Flush/Surface Bottom 4-1/0 (Al) TGK32 (order separately)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-3/0 (Al TGN6 (order separately)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-3/0 (Al)
Front
Flush/Surface 2/0-300 (Al)
Front
Flush/Surface 2/0-300 (Al)
Front
TGK24 (order separately)
Load Center
Main Breaker
Indoor NEMA 1
2
2
2
2
2
3
3
3PH
5
5
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Rev. 11/13
Data subject to change without notice
This table continued on next page
BuyLog™Catalogwww.geindustrial.com
1-15
Page 16
Load Centers and Circuit Breakers
PowerMark Plus™Load Centers
Three-Phase, Four-Wire, 208Y/120 Vac
Main Circuit Breaker Factory Installed
1
Section 1
Load Center
Main Breaker
Indoor NEMA 1
Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
200 30 14 10 30 Combination Top 12 1-250 (Cu), TGK32 (order separately) TM30420C
200 30 14 10 30 Combination Bottom 12 1-250 (Cu), TGK32 (order separately) TM30420CB
200 42 20 14 42 Combination Top 14 1-250 (Cu), TGK42 (order separately) TM42420C
200 42 20 14 42 Combination Bottom 14 1-250 (Cu), TGK42 (order separately) TM42420CB
225 42 20 14 42 Combination Top 15 1-300 (Cu), (2) TGL2 (order separately) TM42422C
225 42 20 14 42 Combination Bottom 15 1-300 (Cu), (2) TGL2 (order separately) TM42422CB
1
Also UL Listed for three-phase, four-wire 240/120 Volts Hi leg delta and three-phase, three-wire 240 Volts ac branch breakers installed.
Flush/Surface 2/0-250 (Al)
Front
Flush/Surface 2/0-250 (Al)
Front
Flush/Surface 2/0-250 (Al)
Front
Flush/Surface 2/0-250 (Al)
Front
Flush/Surface 2/0-300 (Al)
Front
Flush/Surface 2/0-300 (Al)
Front
Load Center
Main Breaker
Outdoor NEMA 3R
Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 3 Pole, Total Main Wire Size Ampere 1” 1” 1” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
100 18 8618 Top R4 6-1/0 (Cu), TGK24 (order separately) TM18410R
125 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30412R
150 24 12 8 24 Top R6 1-3/0 (Cu), TGK32 (order separately) TM24415R
150 30 14 10 30 Top R7 1-3/0 (Cu), TGK32 (order separately) TM30415R
200 30 14 10 30 Top R7 1-250 (Cu), TGK32 (order separately) TM30420R
200 42 20 14 42 Top R8 1-250 (Cu), TGK42 (order separately) TM42420R
225 42 20 14 42 Top R8 1-300 (Cu), TGK42 (order separately) TM42422R
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
4-1/0 (Al) TGK32 (order separately)
2/0-3/0 (Al)
2/0-3/0 (Al)
2/0-3/0 (Al)
2/0-250 (Al)
2/0-250 (Al)
2/0-300 (Al)
3PH
3PH
1-16
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 17
Load Centers and Circuit Breakers
PowerMark Gold Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Section 1
Load Center
Generator Panels
Riser Panels
Spa Panels
Product Features - Generator Panels
—Suitable for use in accordance with Article 702 of the National
Electrical Code, ANSI/NFPA 70
—Single-phase, 2 interlock 60A or 30A main breakers, 8 circuits
max.
—Safety and convenience when using a generator - 14,000 peak
wattage, 11,520 continuous load, 48 amps at 240 volts.
—Maintains power to such critical circuits as those for furnace,
pump, refrigerator, lights.
—Connected dual breaker mechanism ensures that only one
TL412R250GF TM830FCUGEN
source is active at a time.
Generator Panels, Two Interlocked Main Breakers Factory Installed Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
30 42 8 4 8Flush Front Top 3A 6-1 TGK12 included TM830FCUGEN
30 42 8 4 8Surface Front Top 3A 6-1 TGK12 included TM830SCUGEN
60 42 8 4 8Flush Front Top 3A 6-1 TGK12 included TM860FCUGEN
60 42 8 4 8Surface Front Top 3A 6-1 TGK12 included TM860SCUGEN
Bottom
Bottom
Bottom
Bottom
Generator Panels, Two Interlocked Main Breakers Factory Installed Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Number Cu-Al Ground Kit Number
30 42 8 4 8 Top R2A 6-1 TGK12 included TM830R CUGEN 60 42 8 4 8 Top R2A 6-1 TGK12 included TM860R CUGEN
Riser Panels Indoor (NEMA 1) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Front Type Type Number Cu-Al Ground Kit Number
125 20 10 40 20 40 Combination Top 9A 6-2/0 TGK12 (order TLM2012CCURP
Tap kits required, order separately. See page 1-29. Auxiliary gutters available. See page 1-29.
Flush/Surface Front separately)
Spa Panels Outdoor (NEMA 3R) Enclosure
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size Ampere 1” 1” 1/2” 1/2” 1-pole Load Center Feed Box (AWG/kcmil) Equipment Product Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
125 42 8 4 8Factory Included Top 1-2/0 TGL1 installed TL412R250GF
125 42 8 4 8Factory Included Top 1-2/0 TGL1 installed TL412R260GF
50A GFCI Bottom
60A GFCI Bottom
Twist Lock Power Inlets
Receptacles Amps Volts UL Number
L14-20 20 120/240 Canada, US T020N L14-30 30 120/240 Canada, US T030N CS637 50 120/240 Canada, US T050N
Product
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-17
Page 18
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Section 1
Meter Socket LC
Ring Type
Meter Main
Designed and manufactured for quality applications, these PowerMark Gold Meter Socket Load Centers are a superior solution to specific applications. Increased durability and reliability, maximum circuit layout flexibility and ease of installation add up to lower total installed cost .
The Ringless UL Style meter socket load centers (Florida Meter Group, Georgia Power, Others) are specifically designed to meet UL requirements as well as some special features required by spe­cific utilities. If your local utility does not require specific approval and you need a ringless meter socket load center, use the Florida Meter Group style.
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
TSM2020CFCU
Meter Main - Ring Type, Field Installed Mains
100 21414Outdoor Semi-Flush None OH/UG UL TSL210CFCU
100 21414Outdoor Surface
125 42636Outdoor Surface
200 42636Outdoor Semi-Flush None OH/UG UL TSL420CFCU
200 42636Outdoor Surface
(NEMA 3R) EUSERC
(NEMA 3R) EUSERC
(NEMA 3R) EUSERC
(NEMA 3R) EUSERC
(NEMA 3R) EUSERC
2
None OH/UG UL TSL210CSCU
2
None OH/UG UL TSL412CSCU
2
None OH/UG UL TSL420CSCU
Meter Main - Factory Installed Mains
100 00000Outdoor Surface
125 00000Outdoor Surface
150 00000Outdoor Surface
200 00000Outdoor Surface
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
2
Devices include removable closing cap. Order hub separately. See page 1-27.
3
Surface mounted units have two hub provisions on top end wall.
4
THQL and THHQL only, 125 amp max. TQDL is obsolete.
5
Restricted
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
2
None OH/UG UL TM10RMC
2
None OH/UG UL TM12RMC
2
None OH/UG UL TM15RMC
2
None OH/UG UL TM20RMC
1PH
NEMA 3R
1
1,2,3
1,2,3
1,4,5
1,2,3,4
2
2
2
2
Application Data
4 4 4 4
Main Wire Size
2-250 2-250 2-250 2-250
Rev. 11/13
Data subject to change without notice
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst . (AWG/kcmil) Equipment Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSL210CFCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed TSL210CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed TSL412CSCU R12 14 23-1/2 4-7/8 THQP/THQL 6-2/0 TGL1 installed TSL420CFCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed TSL420CSCU R14 14 30-3/4 5-3/4 THQP/THQL 1-250 TGL1 installed TM10RMC R32 16 17 5 TQD Field Installed TM12RMC R32 16 17 5 TQD Field Installed TM15RMC R32 16 17 5 TQD Field Installed TM20RMC R32 16 17 5 TQD Field Installed
1-18
BuyLog™Catalog
www.geindustrial.com
Page 19
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Section 1
Meter Socket LC
Ring Type
Farm Panel
Main Breaker
NEMA 3R
Ring Type - Farm Panel - Main Breaker
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
200 42 8 3 8Outdoor Surface None OH/UG UL TSF420CSCU
1
Devices include removable closing cap. Order hub separately. See page 1-27.
2
Separate field mounted service disconnect can be added, THQL/THHQL. See wiring diagram on page 1-35.
(NEMA 3R) EUSERC
1PH
1,2
Application Data
Product Box Unit Width Unit Height Depth Factory Inst. Field Inst. (AWG/kcmil) Equipment Number Number (in inches) (in inches) (in inches) Svcs Disc Svcs Disc Cu-Al Ground Kit
TSF420CSCU R16 16-3/4 33 6-3/16 THQMV THQL/THHQL 1-300 TGK12 (order separately)
Ring Type Feed-Thru - Main Breaker
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Front Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Type Type Incoming Certification Number
150 42838Outdoor Surface None OH/UG UL TSM415CSCU
150 8416 6 16 Outdoor Surface None OH/UG UL TSM815CSCU
150 8416 6 16 Outdoor Surface None OH/UG UL TSM815CSFL
200 42838Outdoor Surface None OH/UG UL TSM420CSCU
200 8416 6 16 Outdoor Surface None OH/UG UL TSM820CSCU
200 8416 6 16 Outdoor Surface None OH/UG UL TSM820CSFL
1
Devices include removable closing cap. Order hub separately. See page 1-27.
(NEMA 3R
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
(NEMA 3R
(NEMA 3R)
Main Wire Size
1
1
1
1
1
1
Application Data
Product Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM415CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included TSM815CSCU R16 16-3/4 33 6-3/16 THQMV 1-300 TGK12 (order separately) TSM815CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included TSM420CSCU R36 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included TSM820CSCU R16 16-3/4 33 6-3/16 THQMV 6-350 TGK12 (order separately) TSM820CSFL R37B 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included
Main Wire Size
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-19
Page 20
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Narrow, Wide, Over/Under
Section 1
Meter Socket LC
Ring Type
Main Breaker
NEMA 3R
Ring Type - Side by Side - Main Breaker - OH/UG
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
100 16 8 32 14 32 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1610CFCU 125 12 6 24 12 24 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1212CFCU 125 16 8 32 14 32 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM1612CFCU 200 20 10 40 18 40 Outdoor Semi-Flush None OH/UG UL/EUSERC TSM2020CFCU 100 16 8 32 14 32 Outdoor Surface None OH/UG UL/EUSERC TSM1610CSCU 125 12 6 24 12 24 Outdoor Surface None OH/UG UL/EUSERC TSM1212CSCU 125 16 8 32 14 32 Outdoor Surface None OH/UG UL/EUSERC TSM1612CSCU 200 20 10 40 18 40 Outdoor Surface None OH/UG UL/EUSERC TSM2020CSCU
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
2
Devices include removable closing cap. Order hub separately. See page 1-27.
3
Surface mounted units have two hub provisions on top end wall.
1 1 1 1 1,2,3 1,2,3 1,2,3 1,2,3
Application Data
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM1610CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately) TSM1212CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately) TSM1612CFCU R19 14-3/4 28-1/2 7-5/16 THHQL 12-2/0 TGK12 (order separately) TSM2020CFCU R17 16-3/4 34-1/4 7-5/16 THQMV 1-300 TGK12 (order separately) TSM1610CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately) TSM1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately) TSM1612CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately) TSM2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Main Wire Size
1PH
Ring Type - Extra Wide - Main Breaker
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
200 32 16 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3220UWCU 200 40 20 0040 Outdoor Surface None UG UL/EUSERC TSM4020UWCU
2
Devices include removable closing cap. Order hub separately. See page 1-27.
2 2
Application Data
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM3220UWCU R28 22-1/2 27-7/8 6-1/4 THQMV 1-300 TGK12 (order separately) TSM4020UWCU R29 22-1/2 34-7/8 6-1/4 THQMV 1-300 TGK12 (order separately)
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Main Wire Size
Ring Type - Top/Bottom - Main Breaker
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
200 24 12 36 18 42 Outdoor Semi-Flush None UG UL/EUSERC TSM2420UF42 200 32 14 16 6 40 Outdoor Semi-Flush None UG UL/EUSERC TSM3220UFCU 225 20 10 40 18 40 Outdoor Semi-Flush None UG UL/EUSERC TSM2022UFCU 225 32 14 16 6 40 Outdoor Semi-Flush None UG UL/EUSERC TSM3222UFCU 200 24 12 36 18 42 Outdoor Surface None UG UL/EUSERC TSM2420US42 200 32 14 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3220USCU 225 20 10 40 18 40 Outdoor Surface None UG UL/EUSERC TSM2022USCU 225 32 14 16 6 40 Outdoor Surface None UG UL/EUSERC TSM3222USCU
1
Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Product number TJAW53; order separately.
2
Devices include removable closing cap. Order hub separately. See page 1-27.
3
Surface mounted units have two hub provisions on top end wall.
1
1,2,3
1 1 1
Application Data
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSM2420UF42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately) TSM3220UFCU R27 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately) TSM2022UFCU R21 14-9/16 43-5/8 7-3/16 THQMV 1-300 TGK12 (order separately) TSM3222UFCU R22 16-3/16 48-1/8 7-3/16 THQMV 1-300 TGK12 (order separately)
TSM2420US42 R17 16-3/4 34-1/4 7-5/16 THQMV 1-4/0 TGK12 (order separately) TSM3220USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately) TSM2022USCU R26 14-9/16 43-5/8 6-3/16 THQMV 1-300 TGK12 (order separately) TSM3222USCU R27 14-9/16 48-1/8 6-3/16 THQMV 1-300 TGK12 (order separately)
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Main Wire Size
1-20
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 21
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Section 1
Meter Socket LC
Ringless with Bypass
Xcel Energy
NEMA 3R
Ringless with Bypass - Xcel Energy
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Main Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Type Front Type Type Incoming Certification Number
125 42 838Outdoor MLO Surface Horn Bypass OH/UG Xcel/UL TSLR412CSCU
125 42 636Outdoor MLO Surface
125 12 6 24 10 24 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR1212CSCU
125 12 6 24 12 24 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB1212CSCU
150 42 838Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR415CSCU
150 20 10 40 18 40 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR2015CSCU
150 20 10 40 18 40 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB2015CSCU
200 42 636Outdoor MLO Surface
200 42 838Outdoor MLO Surface Horn Bypass OH/UG Xcel/UL TSLR420CSCU
200 42 838Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR420CSCU
200 20 10 40 18 40 Outdoor MB Surface Horn Bypass OH/UG Xcel/UL TSMR2020CSCU
200 20 10 40 18 40 Outdoor MB Surface Lever OH/UG Xcel/UL TSMB2020CSCU
1
Devices include removable closing cap. Order hub separately. See page 1-27.
(NEMA 3R)
(NEMA 3R) Bypass
(NEMA 3R)
(NEMA 3R) Bypass
(NEMA 3R)
(NEMA 3R)
(NEMA 3R) Bypass
(NEMA 3R) Bypass
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
(NEMA 3R) Bypass
1
Lever OH/UG Xcel/UL TSLB412CSCU
1
Lever OH/UG Xcel/UL TSLB420CSCU
1PH
1
1
1
1
1
1
1
1
1
1
Application Data
2 2
2 2
Main Wire Size
6-350 TGK12 (order separately)
6-350 TGL1 installed
6-350 TGL1 installed 6-350 TGK12 (order separately)
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSLR412CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed TSLB412CSCU R12 14 23-1/2 4-7/8 Field Installed TSMR1212CSCU R30 14-9/16 40-1/2 6-3/16 THHQL 6-350 TGK12 (order separately) TSMB1212CSCU R20 14-3/4 27-5/16 5-7/16 THHQL 12-2/0 TGK12 (order separately) TSMR415CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed TSMR2015CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately) TSMB2015CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately) TSLB420CSCU R14 14 30-3/4 5-3/4 Field Installed TSLR420CSCU R31 14-9/16 33-9/16 6-3/16 Field Installed TSMR420CSCU R31 14-9/16 33-9/16 6-3/16 THQMV 6-350 TGK12 installed TSMR2020CSCU R30 14-9/16 40-1/2 6-3/16 THQMV 6-350 TGK12 (order separately) TSMB2020CSCU R18 14-3/4 33 6-5/16 THQMV 1-300 TGK12 (order separately)
2
THQL and THHQL only. 125 amp max. TQDL is obsolete.
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-21
Page 22
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Section 1
Meter Socket LC
Ringless
Georgia Power
Florida Meter Group
Main Breaker
NEMA 3R
Georgia Power Ringless - Main Breaker
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
150 –– –– –Outdoor Surface None OH/UG UL/GP TSMR015CSGP
200 –– –– –Outdoor Surface None OH/UG UL/GP TSMR020CSGP
150 42 83 8Outdoor Surface None OH/UG UL/GP TSMR415CSCUGP
200 42 83 8Outdoor Surface None OH/UG UL/GP TSMR420CSCUGP
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
1PH
1,4
1,4
1,4
1,4
Application Data
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSMR015CSGP R32A 18-7/8 18-9/16 5 THQD 2-250 – TSMR020CSGP R32A 18-7/8 18-9/16 5 THQD 2-250 – TSMR415CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included TSMR420CSCUGP R40 14 32 4-1/2 THQMV 6-350 TGL2 included
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
Main Wire Size
Florida Meter Group MSLC Ringless - Main Breaker
Main Ampere 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total 1-pole Enclosure Bypass UL Agency Product Rating 1” Spaces 1” Spaces 1/2” Spaces 1/2” Spaces Spaces Type Front Type Type Incoming Certification Number
150 42 83 8Outdoor Surface None OH/UG UL/FMG TSMR415CSFLFMG
200 42 83 8Outdoor Surface None OH/UG UL/FMG TSMR420CSFLFMG
150 84 16 6 16 Outdoor Surface None OH/UG UL/FMG TSMR815CSFLFMG
200 84 16 6 16 Outdoor Surface None OH/UG UL/FMG TSMR820CSFLFMG
200 20 4 40 18 40 Outdoor Surface None OH/UG UL/FMG TSMR2020CSCUFMG
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
(NEMA 3R)
Application Data
Product Number Number (in inches) (in inches) (in inches) Svcs Disc Cu-Al Ground Kit
TSMR415CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included TSMR420CSFLFMG R36A 14 28-1/2 4-1/2 THQMV 6-350 TGL2 included TSMR815CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included TSMR820CSFLFMG R37A 14 31-3/4 4-1/2 THQMV 6-350 TGK24 included TSMR2020CSCUFMG R40
1
Use FMG unit if Ringless standard UL design is required by your local utility.
2
No feed through lugs.
3
Knock outs are the same as R36A.
4
Feed-thru lugs provided.
Box Unit Width Unit Height Depth Factory Inst. (AWG/kcmil) Equipment
3
14 34-1/2 4-1/2 THQMV 6-350 TGK24 included
Main Wire Size
4
4
2
1-22
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 23
Load Centers and Circuit Breakers
PowerMark Gold Meter Socket Load Centers
Single-Phase, Three-Wire, 120/240 Vac
With Bonded Neutrals
Section 1
Meter Socket LC
Class 320
NEMA 3R
Class 320
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Ampere 1” 1” 1/2” 1/2” 1-pole Enclosure Bypass UL Agency Product Rating Spaces Spaces Spaces Spaces Spaces Type Front Type Type Incoming Certification Number
320 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2432RMS
400 00000Outdoor Surf/Semi Lever Bypass UG UL TSDR040UFCU
300 8416 6 16 Outdoor Surface Lever Bypass UG UL TSDR830USCU
400 8416 6 16 Outdoor Surface Lever Bypass UG UL TSDR840UFCU
400 24 12 32 14 40 Outdoor Surf/Semi K-4 Bolt-In UG UL TM2440RMKS
400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TM2440RMRS
400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TM2440RMS
400 24 12 32 14 40 Outdoor Surf/Semi Lever Bypass UG UL TMH2440RMRS
400 24 12 32 14 40 Outdoor Surf/Semi None UG UL TMH2440RMS
320 00000Outdoor Surf/Semi Lever Bypass UG UL TSD032UFCU
320 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2432UC42
400 24 12 32 14 42 Outdoor Surf/Semi Link Bypass UG UL TSDA2440UC42
1
200A main breaker factory installed. Space provided for field mounted TQD-WL sub feed.
2
For semi-flush applications, order surface enclosure load center and field installed kit, Product number SF400.
3
Stud provisions only provided.
4
22 kAIC.
(NEMA 3R)
(NEMA 3R)
(NEMA 3R) FMG
(NEMA 3R) FMG
(NEMA 3R) Meter Provision
(NEMA 3R)
(NEMA 3R) EUSERC
(NEMA 3R) Xcel
(NEMA 3R)
(NEMA 3R)
(NEMA 3R) EUSERC
(NEMA 3R) EUSERC
1,2,3
1,2,3
1PH
4
4
4
1,2,3
1,2,3
1,2,3,4
1,2,3,4
4
4
4
Application Data
Product Box Unit Width Unit Height Depth Factory Inst . Field Inst . (AWG/kcmil) Equipment Number Ringless Number (in inches) (in inches) (in inches) Main Breaker Main Breaker Cu-Al Ground Kit
TM2432RMS No R24 30-1/4 40 6 TQD THQL (1) 800 or (2) 400 compression type; (2) TGL2
TM2440RMS No R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
TMH2440RMS No R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2
TSDA2432UC42 No R24 30-1/4 40 6 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2
TSDA2440UC42 No R24 30-1/4 40 6 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
TSD032UFCU No R33 30-1/4 33 6-3/32 THQD THQL/THHQL (1) 800 or (2) 400 compression type (2) TGL2
TM2440RMKS Yes R23 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
TM2440RMRS Yes R24 30-1/4 40 6 TQD TQD (1) 800 or (2) 400 compression type; (2) TGL2
TMH2440RMRS Yes R24 30-1/4 40 6 THQD THQD (1) 800 or (2) 400 compression type; (2) TGL2
TSDR040UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
TSDR840UFCU Yes R33 30-1/4 33 6-3/32 THQD TQD/THQD (1) 800 or (2) 400 compression type (2) TGL2
Main Wire Size
(1) 1000 or (2) compression type; (order separately)
(1) 1000 or (2) 350 pressure type
(1) 1000 or (2) 350 pressure type (order separately)
(1) 1000 or (2) 350 pressure type (order separately)
(order separately)
(order separately)
(order separately)
(1) 1000 or (2) 350 pressure type (order separately)
(1) 1000 or (2) 350 pressure type (order separately)
(1) 1000 or (2) 350 pressure type (order separately)
(order separately)
(order separately)
Rev. 11/13
Data subject to change without notice
BuyLog™Catalogwww.geindustrial.com
1-23
Page 24
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description Number
Main Circuit Breaker Kit - Order appropriate THQL TQMH000 10kAIC or THHQL 22kAIC breakers separately 1
Please review the footnotes listed with the individual Load Center product numbers for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
PowerMark Plus™Equipment Ground Kits
Description Standard Package Quantity Number
(4) 14-8Cu/12-8AL, 20 TGL1 (3) 14-4Cu/6-4AL (8) 14-8Cu/12-8AL, 20 TGL2 (6) 14-4Cu/6-4AL (7) 14-8Cu/12-8AL, (3) 14-4Cu/6-4AL , 20 TGL8 (2) 14-4Cu/12-4AL, (1) 14-2Cu/AL (1) 6-2/0Cu/Al Number of Terminals, 20 TGL20 Equipment Ground Kits (3) 10-1/0 Cu/Al Number of Terminals 1 TNG3 for 400 and 600 Amp (6) 10-1/0 Cu/Al Number of Terminals 1 TNG6 for 400 and 600 Amp
1
TGL2, TGL4 and TGL8 mount interchangeably
2
Add-on Equipment Ground Lug (for use on any TGL Kit)
3
Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole
Product
1
Product
1
1
2
3
4
Section 1Load Centers and Circuit Breakers
TQMH000
TGL2
TGL20 combined with TGL1
PowerMark Gold Equipment Ground and Isolated Ground Bar Kits
Description Standard Package Quantity Number
4-hole Ground 1 TGK4 12-hole Ground 1 TGK12 24-hole Ground 1 TGK24 32-hole Ground 1 TGK32 42-hole Ground 1 TGK42
4
6-12 circuit indoor load centers use PowerMark Plus style neutrals and grounds
5
Add TGKIS for isolated ground and mount to ground kit.
4,5
Product
TGK12
TGK12 with TGKIS
1-24
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 25
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories
PowerMark Plus™Neutral Kits
Description Range Package Quantity Number
400 & 600 Amp PowerMark Plus™Neutral Kit (5) 14-1/0 1 TNLK1 400 & 600 Amp PowerMark Plus™Neutral Kit (3) 1-300 1 TNLK2 Add-on neutral lug for 100-200 Amp PowerMark 6-2/0 1 286A8894G1 Plus load centers Add-on neutral lug for 100-200 Amp PowerMark 1-300 Cu or 1 192A7663G13 Plus load centers 2/0-300 Al
1
Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole
PowerMark Gold Neutral Kits
Description Range Package Quantity Number
PowerMark Gold Neutral Kit - 6-2/0 1 TNLK20 Mounted on top of neutral only PowerMark Gold Neutral Kit - 6-250 1 TNLK250 Mounted on top of neutral only
PowerMark Gold Neutral/Ground Lug Kits
Mounted on any neutral or ground position by removing the termination screw
Description Range Package Quantity Number
Neutral/Ground Lug Kit 6-2/0 1 TLK20 Neutral/Ground Lug Kit 6-250 1 TLK250 Neutral/Ground Lug Kit 6-300 1 TLK300
Wire Standard Product
1 1
Wire Standard Product
Wire Standard Product
192A7663G13
TLK20
Section 1
286A8894G1
TNLK250
TLK250
Isolated Ground Bus Bars Equipment Ground Kit
Description Package Quantity Number
Isolated Ground Bar Kit (order with 1 TGKIS TGK Equipment Ground Kits) Isolated Ground Bar Feet (Order with TGK8) 1 TGKIS2
Standard Product
Subfeed Lug Kits
Description Package Quantity Number
125A 2 Pole Plug-in 1 THLK2125 150A 2 Pole Plug-in - For use with PowerMark Gold only 1 THLK2150 200A 2 Pole Plug-in - For use with PowerMark Gold only 1 THLK2200 125A 3 Pole Plug-in 1 THLK3125 225A 3 Pole Plug-in - For use with 3 phase only 1 THLK3225
Standard Product
Sub-feed and Feed-thru Lugs
UL Listed For use in load centers to economically supply power to a subpanel.
Poles Ampere Rating Number
2 125 THLK2125 3 125 THLK3125 2 150 THLK2150 2 200 THLK2200 3 225 THLK3225
1
For use with PowerMark Gold load centers only
2
For use with three-phase load centers only. Includes mounting base.
Product
1 1 2
TGK12 with TGKIS
THLK2125
Rev. 11/13
Data subject to change without notice
www.geindustrial.com BuyLog™Catalog
1-25
Page 26
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories
PowerMark Plus™Main Lug Kits
Product
Description Wire Range (Cu/Al) Number
150 Amp PowerMark Plus™Replacement Main Lug kit 2-3/0 THLK150 200 Amp PowerMark Plus™Replacement Main Lug kit 1-250 THLK200
PowerMark Gold Main Lug Kits
Product
Description Wire Range (Cu/Al) Number
125 Amp PowerMark Gold Replacement Main Lug kit 6-2/0 TMLK125 200 Amp PowerMark Gold Replacement Main Lug kit 6-250 TMLK200 225 Amp PowerMark Gold Replacement Main Lug kit 6-300 TMLK225
For replacement of main lugs on 125 amp load centers; TLM load centers include main lugs.
Section 1
THLK200
PowerMark Gold main lug kits - TMLK200
Door Lock
Standard Product
Description Package Quantity Number
For indoor load centers larger than 12 circuits (Does not fit TPL412) 10 TDL106
Circuit Directory
Standard Product
Description Package Quantity Number
Card and holder with pressure-sensitive backing. 1 TD42 Mounts inside the door.
Touch-up Paint
Standard Product
Description Package Quantity Number
12 3/4 oz. spray can of light gray enamel 1 TSP61
TDL106
TD42
1-26
BuyLog™Catalog
www.geindustrial.com
TSP61
Rev. 11/13
Data subject to change without notice
Page 27
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories
Front Filler Plates
Description Package Quantity Number
1/2” Front Filler Plate 100 TFH 1” Front Filler Plate 50 TQLFP1
Covers 1/2” rectangular breaker knockouts Covers 1” rectangular breaker knockouts
Universal Raintight Hubs
Description Base Size (in.) Package Quantity Number
3/4” Diameter 3 10 TC75 1” Diameter 3 10 TC100 1-1/4” Diameter 3 10 TC125 1-1/2” Diameter 3 10 TC150 2” Diameter 3 10 TC200 2-1/2” Diameter 3 10 TC250 3” Diameter 35TC300 Closing Cap 3 10 TCCP 2” Diameter 4 TCU27 2-1/2” Diameter 4 TCU28 3” Diameter 4 TCU30 3-1/2” Diameter 4 TCU35 4” Diameter 4 TCU40 4” Cover Plate 4 TCUP
1
For 40 and 42 circuit units in R8 boxes only.
Standard Product
Standard Product
Section 1
TFH
TC150
1
Door Handle
Standard Product
Description Package Quantity Number
Replacement Door Handle Universal 1 TRL22
PowerMark Gold Cross Arm
Standard Product
Description Package Quantity Number
Replacement cross arm for PowerMark Gold load centers 1 LCCROSSARM
TRL22
LCCROSSARM
Rev. 11/13
Data subject to change without notice
www.geindustrial.com BuyLog™Catalog
1-27
Page 28
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories
PowerMark Gold Main Breaker Retainers
Description Breaker Type Number
Travel Trailer Main Breaker Retainer Kit THQP THQPSBK for THQP Breakers For use on PowerMark Plus THQL Breakers 225A max For use with 12 - 42 circuit PowerMark Gold THQL THQLRK1 load centers with THQL Breakers For use with 6 - 8 circuit PowerMark Gold THQL THQLRK2 load centers with THQL Breakers For use with TM/TLM1212CCU Mod 2 current model THQL THQLRK3 For use with 6 - 42 circuit PowerMark Gold THQL THQLRK4 load centers with THQL Breakers. Similar to THQLRK1 but it does not take up a breaker space.
load centers with THQL THQLRK
For main lug load centers utilizing a back fed branch breaker as a main
Handle Locks - Padlocking
Description Breaker Type Number
THQP Padlocking Handle Lock THQP TQPPL THQL Padlocking Handle Lock THQL THP100 TQD Padlocking Handle Lock TQD TQDPLD1
Snap on handle lock Padlock not included
Product
Product
Section 1
THQLRK
THQLRK1
THL103
Handle Locks - Non Padlocking
Description Breaker Type Number
THQP Non Padlocking Handle Lock THQP TQPL THQL Non Padlocking Handle Lock THQL THL103
Snap on handle lock
Product
Handle Ties
Description Breaker Type Number
Handle Ties for THQP Breakers - Solid Snap-on THQP THT1 Trip Indicating Handle Ties for THQP Breakers - For 2 THQPs THQP THT2 separated by 2 side-by-side THQPs
Snap-on Handle Tie - Trip Indicating TQC TQHT1
Snap-on Handle Tie - Solid TQC THT104
Multiwire Branch Breaker Handle Tie Kits
TQB
TQL TQB
TQL TQB TQC TQL
All multi-pole breakers have internal common trip Handle ties provide manual on-off capability only between one-pole devices
1
For two single-pole breakers
2
For three single-pole breakers - kit includes (10) pcs.
3
For four single-pole breakers - kit includes (10) pcs.
Product
1
1
TQ3HTK TQ4HTK
THT1
1
THT104
1
2
3
THT2
1-28
BuyLog™Catalog
www.geindustrial.com
TQHT1
Rev. 11/13
Data subject to change without notice
Page 29
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Circuit Breakers
Field Installed Accessories
Load Center Hardware Kits Hardware
Description Package Quantity Number
PowerMark Plus THLK main lug kit in a TLM load center, installation instructions and front mounting screws Powermark Gold Bond Screw Kit Screw 100 - 200A 1 TBS Powermark Gold Bond Screw Kit 225A 1 TBS22 Powermark Gold Hardware kit 1 THDWRKIT containing 20 front mounting screws Powermark Gold Hardware kit 1 THDWRKIT2 containing 10 interior mounting screws
hardware kit: TQD THQD Main or 1 LCHDKIT
Generator Interlock Kit
Description Package Quantity Number
Load Center Generator Interlock Kit 1 THQLLX1 MSLC Generator Interlock Kit 1 THQLLX4 MSLC Generator Interlock Kit 1 THQLLX8CU MSLC Generator Interlock Kit 1 THQLLX8DR MSLC Generator Interlock Kit 1 THQLLX8FL
Standard Product
Standard Product
Section 1
PowerMark Gold Auxiliary Gutter Enclosures
Description Number
24” Auxiliary Gutter Enclosure TMAGB24 28” Auxiliary Gutter Enclosure TMAGB28 28” Auxiliary Gutter Enclosure Flush TMAGB28F 33” Auxiliary Gutter Enclosure TMAGB33 39” Auxiliary Gutter Enclosure TMAGB39 43” Auxiliary Gutter Enclosure TMAGB43 43” Deep Auxiliary Gutter Enclosure TMAGB43D
Product
PowerMark Gold Gutter Tap Kits
Description Number
250 kcmil Lugs Gutter Tap Kit - one kit per phase required TMGT250 500 kcmil Lugs Gutter Tap Kit - one kit per phase required TMGT500 750 kcmil Lugs Gutter Tap Kit - one kit per phase required - TMGT750
Not for use with riser panels
Product
Meter Socket Load Center Flange Kits
Description Number
Semi-Flush Kit 400A for MSLC SF400 Semi-Flush Kit 400A for MSLC Adjustable SF400A Semi-Flush Kit 200A for MSLC Adjustable SF200A
Product
Surge Protectors
Description Number
SurgePro AC 27KA Panel-Mount Surge Protector THQLSURGE
Product
Rev. 11/13
Data subject to change without notice
www.geindustrial.com BuyLog™Catalog
1-29
Page 30
Load Centers and Circuit Breakers
G G G
C C
MAIN LUGS
F F
F
C
MAIN
C E
E
MAIN
BREAKER
SUB-FEED
LUGS
C
MAIN LUGS
F
MAIN
BREAKER
MAIN
BREAKER
EC
MAIN
F F
C
MAIN
C
C
E
MAIN
C
MAIN
C C
C C
E
A A
F F
F
C
MAIN
C C C C
Page Updated 08 / 2016
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1
12
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
TL412R2, TL412R250GF, TL412R260GF
TL240SCU, RCU TL270SCU, RCU
TPL412C, TL412C, TPL412R, TL412R1,
Section 1
TL510RT
TPL412CT, TL412CT
TPL412RT, TL412RT1
TLM612FCU, SCU
FCUD, SCUD, RCU
TM1210CCU, TM1212CCU, TLM1212CCU
TLM1612CCU, TM1612CCU, TM1612RCU
1-30
BuyLog™Catalog
TLM812FCU, SCU, FCUD, SCUD, RCU
TM1210RCU, TM1212RCU, TLM1212RCU
TM1615CCU, TM1615RCU, TM1620CCU,
TLM1620CCU, TLM1620RCU
TM815RCUFL TM820RCUFL
TLM812RCU2
www.geindustrial.com
TM860FCUGEN, TLM830FCUGEN, TM860SCUGEN, TLM830SCUGEN, TM860RCUGEN, TLM830RCUGEN
TLM2012CCURP
TM2420R42B
Rev. 11/13
Data subject to change without notice
Page 31
Load Centers and Circuit Breakers
MAIN
EC
MAIN
C E
MAIN
C E
MAIN
EC
MAIN
EC
MAIN
C E
MAIN
C
MAIN
C
MAIN
C
MAIN
EC
C
MAIN
MAIN
C
MAIN
C E
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1
12
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
TM2412RCU, TLM2412CCU, TLM2412RCU
TM2010CCU, TM2010RCU
TM2410CCU, TM2412CCU
Section 1
TM2020CCU, TM2020RCU
TLM2020CCU, TLM2020RCU
TM2415RCU, TLM2415RCU
TLM2420C42, TM2415C42
TM4020CCU, TM4020RCU
TLM4020CCU, TLM4020RCU
TM3215C42, TLM3220C42, TM3220C42
TM3210CCU
TM4222RCU, TLM4222CCU TLM4222RCU, TM4222CCU
TM3215CCU, TM3215RCU
TM12410
TM3220CCU, TM3220RCU, TLM3220CCU
TL12412
Rev. 11/13
Data subject to change without notice
www.geindustrial.com BuyLog™Catalog
1-31
Page 32
Load Centers and Circuit Breakers
MAIN
C
C
D
MAIN
MAIN
D D D CC
CCCC
C
MAIN
CCD
MAIN
CC CD
C
MAIN
MAIN
C
C
D
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1—
12
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
TL18415, TL18420
Section 1
TL24415, TM24415
TL24440, TM24420
1-32
TM18410
BuyLog™Catalog
www.geindustrial.com
TM30412
TM30415, TL30420, TM30240, TL30422
Rev. 11/13
Data subject to change without notice
Page 33
Load Centers and Circuit Breakers
MAIN
C C D
MAIN
C CCD
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1—
12
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
Section 1
Rev. 11/13
Data subject to change without notice
TL42420, TM42415C, TM42420
www.geindustrial.com BuyLog™Catalog
TL42422
1-33
Page 34
Load Centers and Circuit Breakers
WHM
A A A
C
C
WHM
C
MAIN
BREAKER
SPACE PROVIDED FOR 110A PARALLEL MAIN BREAKER
WHM
A
B
A A
C
C
WHM
C
MAIN
BREAKER
WHM
MAIN
B
C
A
DDC
E
A
Load
Load
C C
WHM
MAIN
BREAKER
WHM
A A A
WHM
MAIN
C B
A
B C
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1—
1 2
Section 1
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
TSL412CSCU
TM10RMC, TM12RMC, TM15RMC, TM20RMC,
TSMR015CSGP, TSMR020CSGP
TSL420CSCU, TSL420CFCU
TSL210CSCU, TSL210CFCU
TSM415CSCU, TSM420CSCU, TSMF415CSFL,
TSMF420CSFL, TSMR415CSCUGP, TSMR420CSCUGP,
TSMR415CSFLFMG, TSMR420CSFLFMG
1-34
TSF420CSCU
BuyLog™Catalog
TSM1212CSCU, TSM1212CFCU
www.geindustrial.com
TSM815CSCU, TSM820CSCU
Rev. 11/13
Data subject to change without notice
Page 35
Load Centers and Circuit Breakers
C C
WHM
MAIN
BREAKER
MAIN
BREAKER
C C
WHM
MAIN
C
C
WHM
A
B
N
WHM
MAIN
BREAKER
B PHA PH
C
E
NEUTRAL
MAIN
BREAKER
WHM
MAIN
BREAKER
WHM
C
E
WHM
WHM
MAIN
BREAKER
MAIN
BREAKER
WHM
C E
WHM
MAIN
D
D
C
C
D
E
A
Sub feed lugs
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1—
1 2
Section 1
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
Rev. 11/13
Data subject to change without notice
TSM1610CSCU, TSM1610CFCU, TSM1612CFCU, TSM1612CSCU
TSM2420UF42
TSM4020UWCU
TSM815CSFL, TSM820CSFL, TSMF815CSFL,
TSMF820CSFL, TSMR815CSFLFMG,
TSMR820CSFLFMG
TSMR1212CSCU, TSMB1212CSCU
www.geindustrial.com BuyLog™Catalog
TSM2020CSCU, TSM2020CFCU
TSM3220UWCU
TSMR2020CSCU, TSMR2015CSCU, TSMB2020CSCU, TSMB2015CSCU
TSM3220USCU, TSM3220UFCU, TSM3222USCU,
TSM3222UFCU
TSLR420CSCU, TSLR412CSCU,
TSLB412CSCU, TSLB420CSCU
1-35
Page 36
Load Centers and Circuit Breakers
MAIN
C
C
C
WHM
Line
Neutral
C
E
WHM
MAIN
Space for Field Installed Second Main Breaker
Space for Field Installed Second Main Breaker
WHM
MAIN
Space for Field Installed Second Main Breaker
WHM
MAIN
CE
C CCD
Space for
Field-installed
TQD Breaker
200A Main
Breaker
WHM
L1 N
L2
Space for
Field-installed
Breaker
WHM
L1 L2
MAIN
C
E
N
C
B PHA PH
C
E
NEUTRAL
WHM
MAIN
BREAKER
WHM
MAIN
D
Ground termination
D
C
C
D
E
PowerMark Gold and Plus Load Centers
Circuit Breakers
Wiring Diagrams
Breaker Fill
Breaker Symbol 1” THQL 1/2” THQP
1—
1 2
Section 1
Wire Range (AWG/kcmil)
Terminal Symbol Cu Al
o 14-8 12-8
14-4 12-4
A 6-2 6-2
B 14-1/0 12-1/0
C 6-2/0 6-2/0
D 1-300 2/0-300
E 1-300 1-300
F 6-1 6-1
G 6-3 6-3
TSDA2432UC42, TSDA2440UC42
TSD032UFCU
TM2440RMKS, RMRS, RMS,
TMH2440RMS, TMH2440RMRS
TSDR040UFCU
TSM2022USCU, TSM2022UFCUTSMR2020CSCUFMG
TSM2015URCU
TSDR840UFCU
1-36
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Page 37
Load Centers and Circuit Breakers
C
C
B
B
G
G
Z
Z
A
A
A
A
B
D
D
D
D
X
W
W
W
X
X
X
C
C
C
C
C
S
S
S
S
S
H
H
A
A
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
K
K
K
N
N
K
K
G
G
B
A
A
A
A
A
A
B
B
B
B
B
B
P
P
P
P
P
C
C
T
T
J
J
A
D
D
D
D
K
K
H
H
A
A
A
B
B
B
B
B
B
JJ
JJ
GGGU
V
C
C
C
R
A
P
H
H
H
H
H
Q
Q
Y
Y
Y
Y
M
M
A
A
A
A
A
A
F D
D
D
D
D
D
Q
A
A
A
A
A
A
H
H
H
H
J
J
D
D
G
G
B
B B
B
BB
D
D
A
K
D
B
B
D
D
K
K
D
D
D
D
D
D
B
B
B
B
B
D
D
D
D
D
B
B
B
B
B
D
AA
D
A
B
B
K
AA
K
B
DD
K
B
Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Indoor Enclosures
Knockouts
Symbol A BCDEFGHJKLMNPQRSTUVWXYZ
5/16 ––––––––––––––––––––––––
3/8 3/8 ––3/8 ––––– –– ––– –––––– –– – 1/2 1/2 1/2 1/2 1/2 1/2 1/2 –––––––––––––––1/2
Conduit –– ––––1111111– 11– –1––1–11
inches –– ––––– ––– ––222222–22––22
Dimensions (in inches)
–– –3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 –––3/4 –––3/4 ––3/4 3/4 3/4
Size –––––––1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 ––1 1/4 1 1/4 –––1 1/4 1 1/4
in –– ––––––––1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 ––––1 1/2 1 1/2 1 1/2
–– ––––– ––– ––––2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 ––2 1/2 2 1/2 –– ––––– ––– ––––––– 3–33–––– – –––––––––––––––––3 1/2 3 1/2 3 1/2 –– –– –– ––––– ––– ––––––– –––4–– ––
Box No. Width Height Depth
1A 5 11/16 10 1/4 3 3/8
2 7 1/2 9 7/32 3 5/16 2A 7 1/4 93 3A 11 9/16 11 3/8 3 3/8
4 14 19 3 3/4 4A 14 19 3 3/4
6 14 23 3 3/4
7 14 24 11/16 3 3/4
8 14 26 7/16 3 3/4
9 14 28 7/16 3 3/4 9A 14 28 7/16 3 3/4 11 14 33 3/16 3 3/4 12 14 35 7/16 3 3/4 13 14 39 3/16 3 3/4 14 14 43 7/16 3 3/4 15 14 43 7/16 4 5/8 16 16 45 1/8 5 13/16 17 20 59 7/8 6 3/32 18 14 16 3 3/8
Box 1A
Box 2
Rev. 11/13
Data subject to change without notice
Box 2A
Box 15
www.geindustrial.com BuyLog™Catalog
Box 3A
Box 16
Box 4, 6, 7, 8, 9, 11, 12, 13, 14
Box 17
Box 4A, 9A
Box 18
1-37
Page 38
Load Centers and Circuit Breakers
X
XX
D
D
D
A
A
W
W
W
B
A
X
Q
Q
Q
D
D
H
A
Q
B
C
C
C
C
C
CC
J
J
R
B
G
V
U
B
HUB
G
B
K
B
B
B
P
P
R
R
L
L
C
T
J
D
D
D
U
R
B
D
J
U
R A
K
D
Mounting provided for universal hubs
K
B
B
K
K
K
K
Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Outdoor Enclosures
Knockouts
Symbol A BCDEFGHJKLMNPQRSTUVWXYZAA BB CC DD
9/16 ––––––––––––––––––––––––––––
3/8 3/8 ––––––– –––––––––––––– –––– – 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ––––––––1/2 –– –– ––1/2 ––1/2 1/2 –– –3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 ––3/4 3/4 3/4 –––3/4 ––3/4 3/4 3/4
Conduit –– –– – – 11 1 1 1 11 –1 1– – 1– –1 –1 – –1 1–
Size –– –– – –1 1/4 – 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 –––1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 –
in –– – – – –1 1/2 –––1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 ––––1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2
Inches –– – –– – – – – – – –2 22 2 22 – 2 2 – –2 2 –2 22
–––––––––––––2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 ––2 1/2 – 2 1/2 ––2 1/2 – ––––––––––––––––––33––––3––– – –––––––––––––––––3 1/2 3 1/2 3 1/2 ––––3 1/2 ––– –– – – – – –– – – – – – –– ––– – – 4– –– – 4– ––
Dimensions (in inches)
Box No. Width Height Depth
R1 7 1/2 9 7/32 3 5/16 R1A 7 1/4 10 3 3/4 R1B 7 3/8 13 3 3/4 R2A 11 1/4 11 1/8 3 1/4 R3A 13 21 1/2 5
R3 12 1/2 21 3/16 4 5/8 R4A 14 11/16 30 3/16 5 1/4
R4 14 33 3/16 4 5/8 R5A 13 29 5
R5 12 1/2 28 11/16 4 5/8 R6A 13 33 5
R6 14 35 7/16 4 5/8 R7A 14 11/16 34 3/16 5 1/4
R7 14 39 3/16 4 5/8 R8A 14 21/32 43 1/4 6 13/32
R8 14 43 11/16 5 3/4
R9 16 45 15/16 5 27/32 R10 20 48 15/16 6 7/8 R11 20 59 15/16 6 7/8 R41 7 1/2 13 1/4 4
Box R1
Box R1A
Box R2A
1-38
Box R3A, R5A, R6A
R8A
BuyLog™Catalog
Box R3, R4, R5, R6, R7
Box R9
Box R8
Box R10, R11
www.geindustrial.com
Box R4A, R7A
Box R41
Rev. 11/13
Data subject to change without notice
Page 39
Load Centers and Circuit Breakers
B
B
C
K
B
B
B
B
B
BB
C
C
G
C
C
CC CC
B
BB
HUB
PUNCHING
HUB
PUNCHING
B B B
B
BB
B
BB
B
B
A
C
C
C
A
AA
D
D
R
K
S
S
Z
R
G
D
B
B
B
B
B
B
B
BB
C
C
G
C
C
CC CC
B
BB
BB
B
B
B
C
C
C
B
B
A
K
B B
B B
S
Z
R
K
AA
D
D
R
K
S
Z
G
B
B
B
B
BB
C
C
C
C
C
A
G
B
B
B
B
C
CC
B
C
C
G
C
C
CC CC
B
BB
BBB
B
Q
Semi-Flush Only
Y
F
F
A
W
B
B
B
F
F
F
EE
B
B
B
A
C
Semi-Flush Only
EE
EE
A
K
E
B
Q
A
C
B
F
Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Meter Socket Load Centers
Knockouts
Symbol A•BCDEFGHJKLMNPQRSTUVWXYZAA BB CC DD EE FF
5/32 –– ––– –––––––––––––––––––––––––
3/8 3/8 ––3/8 –––––––––––––––––––––––– – 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ––––––––1/2 ––––––1/2 ––1/2 1/2 1/2 – –– –3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 ––3/4 3/4 3/4 –––3/4 3/4 3/4 3/4 3/4 3/4
Conduit –– – –– – 1 1 1 1 1 1 1 – 1 1– – 1 – – 1– 1 – – 1 1 – 1–
Size –– – –– –1 1/4 – 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 –– –1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – 1 1/4 1 1/4
in ––– –– –1 1/2 –––1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 ––––1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches –– – –– – –– – – – – 2 2 2 222 – 2 2 – – 2 2 – 2 22 22
–– – –– – –––– –––––2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 ––2 1/2 – 2 1/2 ––2 1/2 2 1/2 2 1/2 –– – –– – –– – – – – – – – –– – – 3 3 –– – – 3 – –– –– –– – –– – –– – – – – – – – –– –3 1/2 3 1/2 3 1/2 –– ––3 1/2 ––––– –– – –– – –– – – – – – – – –– – – – 4 – – ––4 – –– ––
Dimensions (in inches)
Box No. Width Height Depth
R12 14 23 1/2 4 7/8 R14 14 30 3/4 5 3/4 R15 16 3/4 33 6 3/16 R16 16 3/4 33 6 3/16 R17 16 3/4 34 1/4 7 5/16 R18 14 3/4 33 6 5/16 R19 16 3/4 28 1/2 7 5/16 R20 14 3/4 27 5/16 5 7/16 R21 14 9/16 43 5/8 7 3/16 R22 16 3/16 48 1/8 7 3/16 R23 30 1/4 40 6 R24 30 1/4 40 6
Rev. 11/13
Data subject to change without notice
Box R12
Box R14
Box R16
Box R17, R18
Box R21, R22
www.geindustrial.com BuyLog™Catalog
Box R23
Box R19, R20
Box R24
1-39
Page 40
Load Centers and Circuit Breakers
B
B
B
B
L
R
B
B
A
B
C
C
HUB
PUNCHING
HUB
PUNCHING
BB BB B BB
B
BB
C
K
B
L
R
A
B
B
B
C
C
GG
EE EE
E
CC CC CC
9/32
HUB
EE
G
C
CB
B
B
B
EE
BB
BB
B
HUB
PUNCHING
FF
FF
A
B
B
P
G G
HUB
PUNCHING
FF
FF
A
B
B
P
BB
G
C
CB
B
B
B
BB
BB
BB
B
ZZZ Z
S
S B
1/4"
S
HUB PUNCHING
HUB
PUNCHING
Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Meter Socket Load Centers
Knockouts
Symbol A•BCDEFGHJKLMNPQRSTUVWXYZAA BB CC DD EE FF
5/32 –– ––– –––––––––––––––––––––––––
3/8 3/8 ––3/8 –––––––––––––––––––––––– – 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ––––––––1/2 ––––––1/2 ––1/2 1/2 1/2 – –– –3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 ––3/4 3/4 3/4 –––3/4 3/4 3/4 3/4 3/4 3/4
Conduit –– – –– – 1 1 1 1 1 1 1 – 1 1– – 1 – – 1– 1 – – 1 1 – 1–
Size –– – –– –1 1/4 – 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 –– –1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – 1 1/4 1 1/4
in ––– –– –1 1/2 –––1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 ––––1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches –– – –– – –– – – – – 2 2 2 222 – 2 2 – – 2 2 – 2 22 22
–– – –– – –––– –––––2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 ––2 1/2 – 2 1/2 ––2 1/2 2 1/2 2 1/2 – –– ––– –––––––––––––33––––3––––– –– – –– – –– – – – – – – – –– –3 1/2 3 1/2 3 1/2 –– ––3 1/2 ––––– –– – –– – –– – – – – – – – –– – – – 4 – – ––4 – –– ––
Dimensions (in inches)
Box No. Width Height Depth
R25 14 26 4 1/2 R26 14 9/16 43 5/8 6 3/16 R27 14 9/16 48 1/8 6 3/16 R28 22 1/2 27 7/8 6 1/4 R29 22 1/2 34 7/8 6 1/4 R30 14 9/16 40 1/2 6 3/16 R31 14 9/16 33 9/16 6 3/16 R32 16 17 5
R32A 18 7/8 18 9/16 5
R40 14 32 4 1/2
Box R28
Box R31
Box R25
Box R29
Box R26, R27
Box R30
Box R32 Box R32A
1-40
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice
Box R40
Page 41
Load Centers and Circuit Breakers
DDD
D
D
K
AA AA
K
RR
K
DG
DDDDD
SS
SS ZZ
SS
3/32
3/323/32
GG
EE EE
E
CC CC CC
9/32
HUB HUB
DDD
D
D
KK
R R
K
DG
DDDDD
SS
SS ZZ
SS
3/323/32
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
9/32
K
EE
EE
EE
EE
EE
D D D D D
D DBD
B
B B
LL
W
GG
EE
G
G
E
CC CC CC
9/32
HUB HUB
GG
EE EE
E
CC CC CC
9/32
HUB
Section 1
PowerMark Gold and Plus Load Centers
Circuit Breakers
Meter Socket Load Centers
Knockouts
Symbol A B CDEFGHJKLMNPQRSTUVWXYZAA BB CC DD EE FF GG
5/32 –– –––––––––––––––––––––––––––– –
3/8 3/8 ––3/8 –– –– – ––– – –– –– – –– ––– – –– – – – – 1/2 1/2 1/2 1/2 1/2 1/2 1/2 ––––––– –1/2 ––– –––1/2 ––1/2 1/2 1/2 –– – ––3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 ––3/4 3/4 3/4 –––3/4 3/4 3/4 3/4 3/4 3/4 ––
Conduit ––– –– –1 111111–1 1 ––1–– 1– 1––1 1–1– –
Size ––– –– –1 1/4 – 1 1/4 1 1/4 1/1/4 1/1/4 1 1/4 1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 –– –1 1/4 1 1/4 1 1/4 – 1 1/4 1 1/4 – 1 1/4 1 1/4 1 1/4
in ––– –– –1 1/2 –– –1 1/2 1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 ––––1 1/2 1 1/2 1 1/2 – 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
inches –– – –– –– –––– –222 2 22–22 ––22–2 2222 2
–– ––––––– –– –––2 1/2 2 1/2 2 1/2 2 1/2 – 2 1/2 2 1/2 ––2 1/2 – 2 1/2 ––2 1/2 2 1/2 2 1/2 2 1/2 ––– –– –– ––– – –––– – – ––33 ––––3– ––– – 3 ––– –– –– ––– – –––– – – –3 1/2 3 1/2 3 1/2 ––––3 1/2 –––––– ––– –– –– ––– – –––– – – –––4 –– ––4– ––– – –
Dimensions (in inches)
Box No. Width Height Depth
R33 30 1/4 33 6 3/32 R34 30 1/4 40 6 3/32 R35 30 1/4 47 6 3/32 R36 14 28 1/2 4 1/2 R37 14 31 3/4 4 1/2 R38 14 49 1/2 10 R39 14 31 11/16 4 5/8 R40 14 32 4 1/2
Box R36A, R37A
Box R33
Box R36B, R37B
Box R34, R35
Box R38
Rev. 11/13
Data subject to change without notice
Box R39 Box R40
www.geindustrial.com BuyLog™Catalog
1-41
Page 42
Load Centers and Circuit Breakers Section 1
NOTES:
1-42
BuyLog™Catalog
www.geindustrial.com
Rev. 11/13
Data subject to change without notice