GE JSP26, JSS16, JSC26, RS734, RS504 Installation Instructions Manual

...
Page 1
11
229C4053P557-2 31-10567-2 05-04 JR
Installation
30” Electric
Instructions
Slide-In Range
BEFORE YOU BEGIN
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Skill level – Installation of this appliance requires basic mechanical skills.
Completion time – 1 to 3 hours
Proper installation is the responsibility of
the installer.
Product failure due to improper installation is not covered under the Warranty.
WARNING — This appliance must
be properly grounded.
FOR YOUR SAFETY:
CAUTION: For Personal Safety
remove house fuse or open circuit breaker before beginning installation. Failure to do so could result in serious injury or even death.
ANTI-TIP DEVICE
WARNING To reduce the risk
of tipping, the appliance must be secured by properly installed Anti-Tip bracket packed with this appliance.
If the Anti-Tip device supplied with the range does not fit this application, use the universal Anti-Tip device WB2X7909.
WARNING
All ranges can tip
Injury to persons could result
Install Anti-Tip bracket packed
with range
See Installation Instructions
If you pull the range out and away from the wall for any reason, make sure the Anti-Tip bracket is engaged when the range is pushed back against the wall.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.GEAppliances.com
Page 2
2
Installation Instructions
FOR YOUR SAFETY:
All rough-in and spacing dimensions must be met for safe use of your range. Electricity to the range can be disconnected at the outlet without moving the range if the outlet is in the preferred location (remove lower drawer).
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be avoided. If cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that sticks out at least 5beyond the front of the cabinets. Cabinets installed above a cooktop must be no deeper than 13″.
Be sure your appliance is properly installed and grounded by a qualified technician.
PREPARE TO INSTALL THE RANGE
TOOLS YOU WILL NEED
Straight Edge
Drill with 1/8Bit
Hand or Saber Saw
Pencil
Safety Glasses
Tape Measure
REMOVE SHIPPING MATERIALS
Remove all parts from the plastic bag found inside the prepack of the oven and save packaging tape.
1
ANTI-TIP DEVICE INSTALLATION
Before placing range in the counter, check the factory location of the stability device on the back of the range. For convenience you can hook the stability chain in the upper set of holes. Make sure there is no structural interference when using the upper set of holes.
Decide on a location that has no electrical wiring or plumbing.
With the long screw provided anchor the chain to the floor or wall.
Make sure the screw is going into the wall plate or stud at the base of the wall at least 3/4″.
Attach the stability chain so that it lines up with the bracket on the back of the range.
Tug the chain to make sure it is securely fastened.
Take the packaging tape and temporarily attach the loose end of the chain to the rear of the countertop.
Slide the range into the counter leaving enough space behind to attach the chain to the bracket.
G
F
E
D
C
B
A
2
Backguard (some models)
Mainback
Bracket Optional Location
Chain
Chain
Chain
Long Screw
Washer
Tape
Wall Plate
Washer and Screw
Bracket Factory Location
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Chain
Page 3
MINIMUM CLEARANCES (CONT.)
MINIMUM DIMENSIONS BETWEEN
COOKTOP AND CABINETS OR WALLS
Electrical Outlet Area
(Back of counter in cutout not shown for clarity)
The distance from the floor to the top of the counter must be at least 35-7/8″. The maximum countertop height is 38″.
Make sure the wall coverings, countertop and cabinets around the cooktop can withstand the heat (up to 200°F) generated by the range.
NOTE: Dimension for Wall to Front of Door Handle (door closed).
*28FOR MODELS – JSP26, JSS26, JSC26,
JSS16, RS734, RS504
**28-1/2FOR MODELS – JSP39, JSP38, JSP31,
JSP28, RS744, RS622, JS960, JSP40, JSP34
3
3
Installation Instructions
MINIMUM CLEARANCES
The distance from the floor to the top of the counter must be at least 35-7/8″. The maximum counter height is 38″.
30″ ranges conform to U.L. requirements for 0spacing from vertical walls above countertops. However, some kitchen cabinet finishes can be damaged by heat from the range surface elements. Where varnished wood or plastic film finishes are used, a minimum clearance of 6must be maintained.
For listed over-the-range microwave ovens, the microwave ovens can be installed above the cooktop as per manufacturer’s installation instructions.
The range may be placed with 0″ clearance (flush) at the back wall and side walls if the range side trims extend beyond the cabinet fronts at least 1/4″.
See Figures 1 and 2 for all rough-in and spacing dimensions. These dimensions must be met for safe use of your range. The location of the electrical outlet may be changed as needed, but electricity to the range can be disconnected at the outlet without moving the range if the outlet is in the suggested location (remove lower drawer).
3
ANTI-TIP DEVICE INSTALLATION
(CONT.)
Slip the nearest link of the chain onto the bracket. Pull to make sure it is as snug as possible.
Slide the range all the way back. It is normal to have some slack in the chain, but it should not be excessive.
I
H
2
0”
18” Min.
30” Min.
0”
6”
Min.
6”
4
1
2
2
1
4
30”
36”
30”
Acceptable electrical outlet area.
Backguard (some models)
Mainback
Bracket Optional Location
Chain
Bracket Factory Location
281⁄2”** Wall to front of door handle (door closed) 45” with door open
Fig. 5
Fig. 6
Fig. 7
28”*
1
4
5”
Page 4
4
Installation Instructions
PREPARE TO INSTALL THE RANGE
(CONT.)
PREPARATION
Remove all tape and packaging. Be sure to
remove clear plastic film that covers some chrome parts (around glass oven doors, side trim) and any tape and packaging from inside the oven.
Take the accessory pack out of the oven.
Check to be sure that no range parts have
come loose during shipping.
REMOVING PACKAGING MATERIAL
Any packaging materials must
be removed during installation. This will include adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
4
PREPARE THE COUNTER
If you have an existing 30wide cutout that goes all the way to the wall, you have the option to buy a 4Backguard, Model #JXS31 (white), JXS32 (chrome), JXS33 (almond), JXS34 (black), or JXS35 (bisque) or a Main Top Rear Filler Kit, Model # JXS62BB (black), JXS63WW (white), JXS64AA (almond), or JXS65CC (bisque). These kits are available through your GE dealer, if the existing cutout is in a counter that has a backsplash (post­formed top) we recommend that you use the 4backguard kit.
5
PREPARING THE COUNTER
(CONT.)
Determine the dimension of your cutout. See Fig. 9 and Fig. 10. Dimensions given are from front of counter and not from cabinet face. To minimize chipping you may want to apply masking tape to the counter and mark the cut on top of the tape. Use a hand or saber saw to make the cut. For best appearance it is important that the cut be smooth and straight.
If you are NOT using the Filler or Backguard:
If you have a countertop deeper than 25 and you wish to set the range further back into the counter, the cutout may be cut deeper (up to 24-1/2), but there must be at least 24-1/2from the front edge of the countertop and back wall.
5
Filler Strip
Screw
Speed Clip
23-3/16”
30”
Fig. 9
Fig. 8
Page 5
5
Installation Instructions
PREPARE THE COUNTER (CONT.)
If you are using the Filler or Backguard:
NOTE: If the distance from the back wall
to the front of the counter backsplash (Dimension A in Fig. 11) is greater than the standard 1-1/8, there will be a small gap between the wall behind the range and the backguard. This is normal and should not be visually objectionable.
5
SIDE TRIM EXTENSION KIT
If there is a small gap between the sides of the range and the cabinets (up to 1/4″ each side), you can order a side trim extension kit, Pub, #3-A040, through the GE service center.
6
25”
30”
A
Fig. 11
Fig. 10
Page 6
6
Installation Instructions
6
ELECTRICAL CONNECTIONS
TO MAKE ELECTRICAL CONNECTION
Remove the junction block access cover (on range back). See Fig. 12A or 12B. SOME MODELS will have a one-piece wire cover shown in Fig. 12B. When re-installing one-piece wire cover, make sure that wire does not become pinched between wire cover and mainback.
All new constructions, mobile homes, recreational vehicle and installations where local codes do not allow grounding through neutral, require a four-wire flexible cord kit. If the range is rated between 8,750 and 16,500 watts, a range cord kit rated for 40 amps and a minimum of 125/250 Volts is required. If the range is rated between 16,501 and 22,500 watts, a range cord kit rated for 50 amps and a minimum of 125/250 Volts is required. For existing construction, a three wire flexible cord kit may be used, and the same ratings apply as described above.
When using a cord rated 40 Amps, remove the next to outermost knockout (1-3/8 diameter) in the connection plate. Likewise, when using a cord rated 50 Amps, remove the outermost knockout (1-3/4″ diameter) in the plate.
Terminations shall be either closed loop terminals or open-end spade lugs with upturned ends. You must use a clamp or strain relief to hold the cord.
ELECTRICAL REQUIREMENTS
CAUTION: For personal safety,
do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation.
This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specified on the rating plate. The rating plate is located above the storage drawer on the oven frame.
We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70— Latest Edition. You can get a copy by writing:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range.
When installing an electric range in new construction, follow Steps 3 and 5 for 4-wire connection.
You must use a 3-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system.
If the electrical service provided does not meet the above specifications, have a licensed electrician install an approved outlet.
Fig. 12A Fig. 12B
Page 7
7
Installation Instructions
7
POWER CORD AND STRAIN RELIEF INSTALLATION
For power cord installations only (see the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit.
NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover.
Skip to applicable power cord installation.
1
Power cord
Strain relief
Terminal block
Bracket
CONDUIT AND SQUEEZE CONNECTOR INSTALLATION
For conduit installations only, purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block.
NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover.
Skip to applicable conduit installation.
2
Squeeze
connector
Terminal block
Conduit
Bracket
Fig. 13
Fig. 14
Page 8
8
Installation Instructions
8
ELECTRICAL CONNECTIONS (CONT.)
4-WIRE POWER CORD INSTALLATION
WARNING: The neutral wire of
the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw.
Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.
Cut and discard the ground strap. DO NOT DISCARD ANY SCREWS.
Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate and into the frame of the range.
Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block.
Re-intall the junction block access cover making sure that wires do not become pinched between wire cover and mainback.
E
D
C
B
A
4
3-WIRE POWER CORD INSTALLATION
WARNING: The neutral or
ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block.
Remove the 3 lower terminal screws from the terminal block. Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block.
DO NOT remove the ground strap connection.
Re-install the junction block access cover making sure that wires do not become pinched between wire cover and mainback.
B
A
3
Ground strap
Terminal block (appearance may vary)
Neutral terminal
Power cord
Before
After
Terminal block
Terminal block
Neutral terminal
Neutral terminal
Ground strap
Ground plate (grounding to range)
Ground screw
Ground strap
Ground plate
or
Fig. 15
Fig. 16a
Fig. 16b
Page 9
9
Installation Instructions
9
3-WIRE CONDUIT INSTALLATION
Loosen the 3 lower terminal screws from the terminal block. Insert the center bare wire (white/neutral) tip through the bottom center terminal block opening. On certain models, the wire will need to be inserted through the ground strap opening and then into the bottom center block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secured (35 to 50 inch­lbs.). Do not overtighten the screws since it could damage the wires.
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make connection. Connect wires according to this step for 3-wire conduit or the next step for 4-wire conduit.
Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.
Re-install the junction block acces cover making sure that wires do not become pinched between wire cover and mainback.
B
A
5
4-WIRE CONDUIT INSTALLATION
Loosen the three lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.) Do not overtighten the screws since it could damage the wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.
Re-install the junction block access cover making sure that wires do not become pinched between wire cover and mainback.
C
B
A
6
Before
Terminal block
Ground strap
After
Terminal block
Ground plate (grounding to range)
Bracket
Neutral terminal
Wire tips
Wire tips
Terminal block
Conduit
Bracket
Ground screw
Ground strap
or
Fig. 17
Fig. 18a
Fig. 18b
Page 10
10
Installation Instructions
INSTALL THE RANGE
REMOVE OVEN DOOR
Before installing the range, you may remove the oven door to lessen the weight of the unit. DO NOT lift unit by door handle.
To remove oven door:
Open the door to the stop position. See Fig. 19A.
Grasp the door at each side and lift up and off the hinges. See Fig. 19B.
CAUTION:
When the door is removed and hinge arms are at stop position, do not bump or try to move the hinge arms. The
hinges could snap back causing an injury to the hands or damage to the porcelain on the front of the oven. Cover the hinges with toweling or insert empty towel rolls behind the hinges while working in the oven area.
B
A
1
LEVEL THE RANGE
For proper cooking and baking the range must be leveled. Do not place range in cutout until you are sure that the flanges below the sides of the cooktop are above the top of the counter. Lift cooktop to see flanges. Damage to the cooktop could result if adjusted improperly.
Install the oven racks (see use and care section for instructions).
Use a 1-3/8open end wrench or an adjustable wrench to equally back out the four leg levelers until the flanges (rims) below the sides of the maintop are above the top of the counter. Check by measuring the height of the counter and comparing it with the measurement from the floor to the flanges below the sides of the cooktop. Place range in cutout when adjustments are complete.
Put a spirit level or a glass measuring cup partially filled with water on one of the oven racks. See Fig. 21.
Use the wrench to adjust the leg levelers. Level range front to back and side to side. See Fig. 20.
D
C
B
A
2
Fig. 19B
Fig. 20
Fig. 21
Fig. 19A
Stop Position
Hinge
Lower Range
Raise Range
Spirit Level
Leg Leveler
Page 11
11
Installation Instructions
IMPORTANT INSTALLATION INSTRUCTIONS FOR RANGES USED WITH COUNTERTOP HEIGHTS UP TO 38
The height of the range must be adjusted to the countertop height. For countertop heights greater than 37″, additional measurements may need to be taken as detailed below.
When the range is elevated to the maximum height, there is a large space between the bottom of the range and the floor, referred to as the toe space. This may be visually objectionable. The legs should not be extended any further than to provide a maximum of 3 toe space. See Fig. 22.
The range is designed to provide a minimum of 1air gap at the bottom of the range. See Fig. 23. (Example: When legs are screwed all the way into the base rail.)
This gap is very important to the proper ventilation of the range and must be maintained when treating the appearance of the toe space.
The following is a suggested method of making a filler for the toe space when the legs are extended as mentioned before.
After the range is installed with the longer legs and is in position and level, measure from the bottom of the bodyside to the floor. This will be the required height of the toe space filler. See Fig. 22. This height may range from 2-1/16 to 3. Any height less than 2-1/16may not be visually objectionable and not need the filler.
Build the filler as shown in Fig. 24. Make sure to provide the 3/4gap at the top and the 5/16 gap at the bottom. These gaps will provide the proper ventilation as mentioned before.
If you wish to attach the filler to the floor or adjacent cabinets, use screws or other removable fasteners, so that the range can be readily removed if necessary.
3
Fig. 22
3” Max. Height
Fig. 23
Fig. 24
1” Min. Height
Gusset Corners with 3/4” to 1” Triangular or Square Stock
Use 1/4” to 1/2” Material Finished to Match Toe Area of Cabinets
2-1/16” to 3” as Required or as Required to Recess Behind Toe Area of Adjacent Cabinets
6”
5/16”
3/4”
30”
Page 12
12
Notes
Printed in the United States
Loading...