BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
• Risk of re or electric shock. LED Retrot Kit installation requires knowledge of luminaires electrical systems. If not qualied, do not attempt installation. Contact a qualied electrician.
• Risk of re or electric shock. Install this kit only in the luminaires
that have the construction features and dimensions shown in the photographs and/or drawings.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
This device is not intended for use with emergency exits.
Min. lamp compartment dimensions 15 (dia) x 17 (h) mm.
• Risque de choc électrique, le kit d’installation LED Retrot requiert une connaissance des systèmes électriques des luminaires. Si vous n’êtes pas qualié, ne tentez pas l’installation. Contactez un électricien.
• Risque d’incendie ou de choc électrique. N’installez ce kit que dans les luminaires qui ont les caractéristiques de conception et les dimensions indiquées sur les photos et/ou schémas.
• Ne faites/n’altérez pas les trous ouverts dans l’enceinte de câblage ou composants électriques lors de l’installation du kit.
• Pour prévenir tout risque de dommage ou abrasion, n’exposez pas le câblage à des lames métalliques ou autres objets coupants ou pointus.
• Cet appareil n’est pas conçu pour utilisation avec sortie de secours.
• Dimensions minimum du compartiment des lampes : 15mm (diamètre) x 17 (h) mm.
Installation Guide
For standard
medium base
sockets
For GU24 pin base sockets
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
The units covered in this report are intended to retrot Type IC or non-IC recessed mount Listed luminaires with instructions to remove the existing
trim. The minimum dimensions of luminaries are tabulated below. These products are intended to be used in dry or damp locations. These products are
classied as to FIRE and SHOCK hazards only.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [B] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [B] est conforme á la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Components Supplied
• One LED retrot
• One installation instructions sheet
imagination at work
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 95-132 VAC, 50/60 Hz and rated as follows:
Product Code Description
95851 LED10RS6/827GUP 95-132V 50/60 Hz 10W 0.1 A 95852 LED10RS6/830GUP 95-132V 50/60 Hz 10W 0.1 A 95853 LED10RS4/827E26P 95-132V 50/60 Hz 10W 0.1 A 95854 LED10RS4/830E26P 95-132V 50/60 Hz 10W 0.1 A 95855 LED10RS4/827GUP 95-132V 50/60 Hz 10W 0.1 A 95856 LED10RS4/830GUP 95-132V 50/60 Hz 10W 0.1 A 85153 LED10RS6/827E26P 95-132V 50/60 Hz 10W 0.1 A 85160 LED10RS6/830E26P 95-132V 50/60 Hz 10W 0.1 A 70120 LED13RS6/827E26P 95-132V 50/60 Hz 13W 0.15 A 70122 LED13RS6/830E26P 95-132V 50/60 Hz 13W 0.15 A 70124 LED13RS6/827GUP 95-132V 50/60 Hz 13W 0.15 A 70127 LED13RS6/830GUP 95-132V 50/60 Hz 13W 0.15 A
Installation
Mounting
clip
Input
Voltage
Input
Frequency
Input
Wattage
Input
Current
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.
Remove lamp from the packaging
1 3
and check that the mounting clips
are rmly attached.
Insert base socket adapter into
4
existing socket inside the housing.
Restore power to the lighting system.
7
TURN OFF POWER at the source to
2
the recessed housing(s) that you are
installing the xture(s) in.
Link the socket adapter to the
5
matching connector clip attached
to the xture.
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
Remove existing trim and bulb, revealing the existing socket.
Guide xture into the housing and
6
gently push up until ush with the
ceiling.
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo and Lumination are trademarks of the General Electric Company. © 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.