GE PVM9005SJSS Specification Sheet

GE PVM9005SJSS Specification Sheet

PVM9005SJ

GE ProfileSeries 2.1 cu. ft. Over-the-Range Sensor Microwave Oven

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

NOTE: Requires 120V grounded outlet. Electrical receptacle

66" MIN.

Mounting

must be located in cabinet above microwave oven. No additional

height

wiring, venting or cabinet rebuilding necessary in many cases.

from

Complete detailed, easy-to-follow installation instructions and

oor

convenient full-size templates are packed with the Spacemaker

 

microwave oven.

Minimum distance from

IMPORTANT INFORMATION: When installing the microwave

door hinge side to

adjacent wall should

oven over a range, allow minimum of 2" from bottom of microwave

equal 3/4 inch.

oven to top of range backguard to allow for removal of

 

light covers.

 

VENTILATION OPTIONS: The microwave ovens are designed for adaptation to the following three types of ventilation:

Outside exhaust (vertical – as shown)

Outside exhaust (horizontal)

Recirculating (non-vented ductless – see Filter Kit drawing)

INSTALLATION INFORMATION: This information is not intended to be used for installing unit described. Before

installing, consult installation instructions packed with product/ kit for current dimensional data.

30"

100° Door open

(without obstruction)

30"

MIN. width required

14 5/8" MAX. 11 1/2" MIN.*

Exhaust outlet connects to 3-1/4" X 10" duct

16-5/32"

17-1/8" (rear)

16-1/2"

*Maximum depth with JX15

Bump Out Kit is 16". Bump Out Kit

sold separately.

For answers to your Monogram, GE CaféSeries, GE ProfileSeries or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 1/16

PVM9005SJ

GE ProfileSeries 2.1 cu. ft. Over-the-Range Sensor Microwave Oven

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.

REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed

140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

DUCT

EQUIVALENT FEET

A. Rectangular-To-round

 

Transition Adaptor

5 ft.

B. Wall Cap

40 ft.

C. 90° Elbow

10 ft.

D. 45° Elbow

5 ft.

E. 90° Elbow

25 ft.

F. 45° Elbow

5 ft.

G. Roof Cap

24 ft.

OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)

Filter Kit JX81C– Recirculating Charcoal Filter Kit To be used when the microwave oven cannot be vented to the outside.

For answers to your Monogram, GE CaféSeries, GE ProfileSeries or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.

Listed by

Underwriters

Laboratories

Specification Revised 1/16