GE PSFA Specification Sheet

GE
FLOOD LIGHTING
g
Lighting Solutions
GUIDE FORM SPECIFICATIONS
POWR•SPOT ® III FLOODLIGHT
GENERAL DESCRIPTION
The NEMA ____ (specify heavy-duty or general-purpose) weather-resistant floodlight designated ____ (identify) GE POWR•SPOT® III floodlight , ordering number ____ (specify PSFA, plus ordering number logic from catalog), or approved equal, for operation of one ____ (specify [400 or 750] watt high pres­sure sodium [HPS] or [1000, 1500 or 1650] watt metal halide) lamp from a nominal ____ (specify 120, 208, 220, 240, 277 347 or 480 volt , 60 Hz or 220 or 240 volt , 50 Hz) power source and shall be capable of starting and operating the indicated lamp within the limits specified by the lamp manufacturer. The flood­light shall contain a completely prewired integral ballast and optical assembly with ____ (specify 1X1, 2X2, 3X3, 4X4, 5X5 or 6X6 according to photometric selection table) NEMA type beam spread (horizontal X vertical). The floodlight shall be UL/cUL Listed SUITABLE FOR WET LOCATIONS. The floodlight shall have a decal indicating reflector identification viewable from the ground. Standard construction is IP55. Ballast, housing, optical and luminaire assembly shall all be from the same manufac­turer.
MECHANICAL CONSTRUCTION
For ease of installation and to facilitate maintenance and replacement, the floodlight shall be supplied as components — ballast and optical.
The ballast assembly shall include a die-cast aluminum hous­ing with electrocoat gray paint finish applied inside and out . The ballast assembly shall have a formed aluminum front panel that accesses a generous wiring compartment contain­ing wiring with pre-stripped leads; a built-in weather-resistant strain-relief bushing; and a heavy-gauge steel trunnion pro­tected by a weather-resistant coating. The access panel shall function as a condensate drain for luminaires aimed down­ward. The ballast assembly shall contain a vertical degree marker and a repositioning stop. All hardware shall be of a corrosion-resistant material or be protected by a corrosion­resistant finish.
The ballast assembly shall be configured so that the socket is thermally isolated from the ballast compartment .
The ballast assembly shall contain an E39 mogul base socket with superior lamp gripping. The socket shall have added insu­lation, giving it the ability to handle the higher pulse ratings of newer HID systems.
OPTICAL ASSEMBLY
The general purpose sealed optical assembly shall include a hinged door with stainless spring steel door latches, tem­pered door glass, silicone rubber door gasket, and airway with charcoal impregnated dacron filter.
There shall be a one-piece spun aluminum (specify 20-inch [508 mm] or 22-inch [559mm] reflector protected inside and out by an ALGLAS a corrosion-resistant material or protected by a corrosion­resistant finish.
The heavy duty optical shall include a heavy gauge aluminum outer housing protected inside and out with an electrocoat gray paint finish.
* FOR MORE DEFINITIVE INFORMATION, REFER TO BALLAST SPECIFICATIONS IN TECHNICAL DATA SECTION.
®
finish. All external hardware shall be of
BALLAST OPERATION
The floodlight shall contain a standard Autoreg [CWA] (indicate that 1500 and 1650 watt metal halide must operate design center lamp at rated watts on nominal power supply after ther­mal stabilization) ballast* circuit in full compliance with lamp­ballast specifications available to the fixture manufacturer from the lamp manufacturers at the time of fixture manufacture.
The ballast assembly shall contain a ballast which will reliably start and operate the lamp in ambient temperatures down to
o
-20
F for metal halide.
Guide Form Specifications – 2011
g
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 6 9 4 3 5 3 3- - -- 8 8 8
GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company. © 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Loading...