2x4’s or
equivalent
solid floor
25-1/4"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box
location
(240-volt
models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
Conduit
(48-1/2"
long)
19"
29-3/4"
A = The unit overlap is 1/2" but allow 5/8" clearance from top edge of cutout
B = The unit overlap is 2-1/4" but allow 2-3/8" clearance from side edges of cutout
C = The unit overlap is 1" but allow 1-1/8" clearance from bottom edge of cutout
Construct Solid Bottom
MIN. 3/8" Plywood
Supported by 2 x 4
or 1 x 2 Runners,
all Four Sides.
(Platform must be
able to support cabinet
load, weight of oven,
and additional
oven loads)
C
25-1/4"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box
location
(240-volt
models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
Conduit
(48-1/2"
long)
19"
29-3/4"
A = The unit overlap is 1/2" but allow 5/8" clearance from top edge of cutout
B = The unit overlap is 2-1/4" but allow 2-3/8" clearance from side edges of cutout
C = The unit overlap is 1" but allow 1-1/8" clearance from bottom edge of cutout
Construct Solid Bottom
MIN. 3/8" Plywood
Supported by 2 x 4
or 1 x 2 Runners,
all Four Sides.
(Platform must be
able to support cabinet
load, weight of oven,
and additional
oven loads)
C
1" Min. above toekick or adjust
to oven installation height
2" MIN between cutouts
3" MIN between cutouts
recommended—2" MIN required
Cutout height and width
per drawer requirements
Junction box location
A
B
Construct Solid Bottom
MIN 3/8" Plywood Supported by
2 x 4 or 1 x 2 Runners, all Four Sides.
(Each platform must be able to support
cabinet load, weight of oven, and
additional oven loads)
4-3/16
Conduit
(46" long)
Cabinet width
(240-volt models only)
21-1/2"
To back
of Control
19"
C
L
2x4’s or
equivalent
solid floor
21-5/8"
over centerline
of cabinet
25-1/4"
Cutout width
cabinet
width
Required
cutout location
36-3/4"
minimum
from floor
Junction box
location
(240-volt
models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and
Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion
spec of at least 194° F temperature rating.
Conduit
(48-1/2"
long)
19"
29-3/4"
C
A = The unit overlap is 1/2" but allow 5/8" clearance from top edge of cutout
B = The unit overlap is 2-1/4" but allow 2-3/8" clearance from side edges of cutout
C = The unit overlap is 1" but allow 1-1/8" clearance from bottom edge of cutout
Construct Solid Bottom
MIN. 3/8" Plywood
Supported by 2 x 4
or 1 x 2 Runners,
all Four Sides.
(Platform must be
able to support cabinet
load, weight of oven,
and additional
oven loads)
C
29-3/4"
PSB9240EF/SF/BL
GE Profile™ Series 30 in. Single Wall Oven with Advantium
®
Technology
ADVANTIUM WALL OVEN/GE PROFILE™ SERIES COOKING
TOWER DIMENSIONS AND CABINET INSTALLATION
INFORMATION (IN INCHES)
NOTE: Cabinets
installed adjacent
to wall ovens must
have an adhesion
spec of at least a
194°F temperature
rating.
NOTE: 2" minimum
between cutouts
when installed
above warming
drawer or single
wall oven.
INS TALL ATION
INFORMATION:
Before installing,
consult installation
instructions packed
with product for current
dimensional data.
NOTE: Advantium 240 volt models cannot be installed under 36 inches height.
NOTE: Use of the accessory drawer will replace the bottom trim piece for
applicable installations. Please see installation instructions for full details.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.
Suitable
bracing
runners
21-5/8"
over centerline
of cabinet
(Platform must be able to support
cabinet load, weight of oven, and
additional oven loads)
C
L
2x4’s or
equivalent
solid floor
Listed by
Underwriters
Laboratories
Speci fication Revised 10/20
PSB9240EF/SF/BL
Installation over Warming Drawer:
Installation over a Wall Oven and Warming Drawer:
GE Profile™ Series 30 in. Single Wall Oven with Advantium
PREPARATION WITH AN ACCESSORY DRAWER
®
Technology
PREPARE THE OPENING: The Advantium 240V can be
installed in combination with other Built-In appliances.
Always follow each product's Installation Instructions to
compete the installation.
SIN GLE OVEN INSTALL ATIO N: Order a 30" wide
single oven cabinet or cut the opening in a wall to the
dimensions shown.
* For existing cutouts, a
27" or 30"
maximum width of 28-1/2"
is acceptable. If the opening
is slightly wider, secure a
25-1/4"
furring strip on each side
of the cutout for securing
21"
the oven.
- Always maintain 36-3/4"
minimum height from
the floor to the cutout in
36-3/4"
Min.
any single or combined
installation.
- The unit overlap on the
top is 1/2" but allow 5/8" clearance from top edge
of cutout. The unit overlap on each side is 2−1/4"
but allow 2−3/8" clearance from side edges of
cutout. The unit overlap on the bottom is 5/8" but
allow 3/4" clearance from bottom edge of cutout.
- Oven overlaps will conceal cut edges on all sides
of the opening.
23-1/2"
Construct base -
Min. 3/8" plywood
supported by 2x4
or 2x2 runners all
four sides.
PREPARE THE OPENING (CONT.)
When installed over a single oven
or a warming drawer, allow at least
2" between the two openings. This
separation will provide clearance for
bottom overlap of the Advantium 240V
and the other appliance overlaps.
Construct a solid oven floor of 3/8" min.
thick plywood supported by 2 x 4 or 2 x
2 runners on all sides.
- The support must be level and rigidly
mounted, flush with the bottom edge
of the cutout.
27" or 30"
36-3/4"
Min.
21"
23-1/2"
25-1/4"
Construct base -
Min. 3/8" plywood
supported by 2x4
or 2x2 runners all
four sides.
2" Min.
(3" recommended)
Per warming
drawer
requirement
* For existing cutouts, a maximum width
of 28-1/2" is acceptable. If the opening is
slightly wider, secure a furring strip on each
side of the cutout for securing the oven.
NOTE: Additional clearances between
the cutouts may be required. Check to be
sure the oven supports above the Warming
Drawer location do not obstruct the
required interior depth and height. See
Warming Drawer installation instructions
for details.
INSTALLATION OVER A BUILT-IN
OVEN AND WARMING DRAWER:
27" or 30"
45-1/4"
Min.
21"
23-1/2"
Construct solid
bottom - Min. 3/8"
plywood supported
25-1/4"
Per warming drawer requirement
by 2x4 or 2x2
runners all four
sides
2" Min.
(3" recommended)
Per oven
requirement
2" Min.
* For existing cutouts, a maximum
width of 28-1/2" is acceptable. If the
opening is slightly wider, secure a
furring strip on each side of the cutout
for securing the oven.
NOTE: Additional clearances between
the cutouts may be required. Check to
be sure the oven supports above the
Warming Drawer location do not obstruct
the required interior depth and height.
See Warming Drawer installation
instructions for details.
CAUTION: For personal safety, the
mounting surface must be capable of
supporting the cabinet load, in addition
to the added weight of the oven and
drawer, plus additional oven loads.
Speci fication Revised 10/20