GE PSB9240EF, PSB9240BL Specification

2x4’s or equivalent solid floor
25-1/4"
Cutout width
cabinet
width
Required
cutout location
36-3/4" minimum from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Conduit
(48-1/2"
long)
19"
29-3/4"
A = The unit overlap is 1/2" but allow 5/8" clearance from top edge of cutout B = The unit overlap is 2-1/4" but allow 2-3/8" clearance from side edges of cutout C = The unit overlap is 1" but allow 1-1/8" clearance from bottom edge of cutout
Construct Solid Bottom MIN. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Platform must be able to support cabinet load, weight of oven, and additional oven loads)
C
to support
25-1/4"
Cutout width
cabinet
width
Required
cutout location
36-3/4" minimum from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Conduit
(48-1/2"
long)
19"
29-3/4"
A = The unit overlap is 1/2" but allow 5/8" clearance from top edge of cutout B = The unit overlap is 2-1/4" but allow 2-3/8" clearance from side edges of cutout C = The unit overlap is 1" but allow 1-1/8" clearance from bottom edge of cutout
Construct Solid Bottom MIN. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Platform must be able to support cabinet load, weight of oven, and additional oven loads)
C
1" Min. above toekick or adjust to oven installation height
2" MIN between cutouts
3" MIN between cutouts recommended—2" MIN required
Cutout height and width per drawer requirements
Junction box location
A
B
Construct Solid Bottom MIN 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Each platform must be able to support cabinet load, weight of oven, and additional oven loads)
4-3/16
Conduit
(46" long)
Cabinet width
(240-volt models only)
21-1/2"
To back
of Control
19"
C
L
2x4’s or equivalent solid floor
21-5/8"
over centerline
of cabinet
25-1/4"
Cutout width
cabinet
width
Required
cutout location
36-3/4" minimum from floor
Junction box location (240-volt models only)
4-3/16"
21-1/2"
To Back of Control
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
Advantium Wall Oven Dimensions (in inches)and Cabinet Installation (in inches)
Note: Cabinets installed adjacent
to wall ovens must have an adhesion spec of at least 194° F temperature rating.
Conduit
(48-1/2"
long)
19"
29-3/4"
C
A = The unit overlap is 1/2" but allow 5/8" clearance from top edge of cutout B = The unit overlap is 2-1/4" but allow 2-3/8" clearance from side edges of cutout C = The unit overlap is 1" but allow 1-1/8" clearance from bottom edge of cutout
Construct Solid Bottom MIN. 3/8" Plywood Supported by 2 x 4 or 1 x 2 Runners, all Four Sides. (Platform must be able to support cabinet load, weight of oven, and additional oven loads)
C
29-3/4"
PSB9240EF/SF/BL
GE Profile™ Series 30 in. Single Wall Oven with Advantium
®
Technology
ADVANTIUM WALL OVEN/GE PROFILE™ SERIES COOKING TOWER DIMENSIONS AND CABINET INSTALLATION INFORMATION (IN INCHES)
NOTE: Cabinets
installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
NOTE: 2" minimum between cutouts when installed above warming drawer or single wall oven.
INS TALL ATION INFORMATION:
Before installing, consult installation instructions packed with product for current dimensional data.
NOTE: Advantium 240 volt models cannot be installed under 36 inches height.
NOTE: Use of the accessory drawer will replace the bottom trim piece for
applicable installations. Please see installation instructions for full details.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Suitable
bracing
runners
21-5/8"
over centerline
of cabinet
(Platform must be able to support cabinet load, weight of oven, and additional oven loads)
C
L
2x4’s or equivalent solid floor
Listed by Underwriters Laboratories
Speci fication Revised 10/20
PSB9240EF/SF/BL
Installation over Warming Drawer:
Installation over a Wall Oven and Warming Drawer:
GE Profile™ Series 30 in. Single Wall Oven with Advantium
PREPARATION WITH AN ACCESSORY DRAWER
®
Technology
PREPARE THE OPENING: The Advantium 240V can be installed in combination with other Built-In appliances. Always follow each product's Installation Instructions to compete the installation.
SIN GLE OVEN INSTALL ATIO N: Order a 30" wide single oven cabinet or cut the opening in a wall to the dimensions shown.
* For existing cutouts, a
27" or 30"
maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a
25-1/4"
furring strip on each side of the cutout for securing
21"
the oven.
- Always maintain 36-3/4" minimum height from the floor to the cutout in
36-3/4"
Min.
any single or combined installation.
- The unit overlap on the top is 1/2" but allow 5/8" clearance from top edge of cutout. The unit overlap on each side is 2−1/4" but allow 2−3/8" clearance from side edges of cutout. The unit overlap on the bottom is 5/8" but allow 3/4" clearance from bottom edge of cutout.
- Oven overlaps will conceal cut edges on all sides of the opening.
23-1/2"
Construct base - Min. 3/8" plywood supported by 2x4 or 2x2 runners all four sides.
PREPARE THE OPENING (CONT.)
When installed over a single oven or a warming drawer, allow at least 2" between the two openings. This separation will provide clearance for bottom overlap of the Advantium 240V and the other appliance overlaps.
Construct a solid oven floor of 3/8" min. thick plywood supported by 2 x 4 or 2 x 2 runners on all sides.
- The support must be level and rigidly mounted, flush with the bottom edge of the cutout.
27" or 30"
36-3/4"
Min.
21"
23-1/2"
25-1/4"
Construct base - Min. 3/8" plywood supported by 2x4 or 2x2 runners all four sides.
2" Min.
(3" recommended)
Per warming drawer requirement
* For existing cutouts, a maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.
NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.
INSTALLATION OVER A BUILT-IN OVEN AND WARMING DRAWER:
27" or 30"
45-1/4"
Min.
21"
23-1/2"
Construct solid bottom - Min. 3/8" plywood supported
25-1/4"
Per warming drawer requirement
by 2x4 or 2x2 runners all four sides
2" Min.
(3" recommended)
Per oven requirement
2" Min.
* For existing cutouts, a maximum width of 28-1/2" is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.
NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.
CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of the oven and drawer, plus additional oven loads.
Speci fication Revised 10/20
Loading...
+ 1 hidden pages