GE PNSF31Z User Manual

TM
PNSF31Z—GE Profile™ SmartWater™Softening System
24
IN
3-13/16
OUT
Top View
IN-OUT
14"  Dia.
45-1/4 45-1/4
38-1/2 38-1/2
35
Side View Front View
Salt Capacity – 300 lbs.
Warranty Information Full One-Year Warranty –
(parts and labor at no additional charge) applies to entire unit.
Limited Three-Year Warranty –
(parts only) applies to electronic monitor.
Limited Ten-Year Warranty –
(parts only) applies to replacement cabinet (brine tank) or resin tank.
See written warranty for details.
Important: All units must be installed according to local plumbing
and electrical regulations.
35
For answers to your Monogram,®GE Profile Performance Series,™GE Profile,™GE, Hotpoint and RCA appliance questions, call GE Answer Center®service, 800.626.2000.
Revised 7/97
TM
PNSF31Z—GE Profile™ SmartWater™Softening System
OUTSIDE FAUCET
(HARD WATER)
SOFT, COLD
WATER
SOFT, HOT
WATER
5. IS THE TRANSFORMER PLUGGED INTO A CONTINUOUSLY "LIVE" 120V-60Hz OUTLET?
6. DID Y OU SET THE TIMER TO THE CORRECT TIME OF DAY, AND WATER HARDNESS NUMBER?
WATER 
HEATER
8. BE SURE THE ELECTRIC OR  FUEL SUPPLY T O THE W ATER HEATER IS ON
7. DID YOU FILL THE BRINE TANK WITH SALT?
EXTREMELY IMPORTANT
• Install softener at point-of-entry into house before water heater. Needs to be within five feet of water inlet.
• Install within ten feet of proper drainage; e.g. drain, standpipe  or a sump which does not drain directly to outside.
• Within ten feet of 120V, 60Hz electrical outlet- transformer must be plugged into an inside outlet.
• All units must be installed according to local plumbing and  electrical regulations.
WATER 
SOFTENER
4. THE BRINE T ANK OVERFLOW HOSE IS A GRAVITY DRAIN. BE 
SURE THE HOSE IS NOT RAISED
HIGHER THAN THE FITTING ON THE TANK AND IS SECURED
NOTE: Should not be installed in  direct sunlight, freezing conditions, or where unit can get wet.
GROUND
STRAP
INLET
SECURED
OUTSIDE FAUCET
(HARD WATER)
1. BE SURE HARD WATER IS PLUMBED INTO SOFTENER  VALVE INLET
2. BE SURE BYPASS VALVE STEM IS POSITIONED FOR SOFT WATER "SERVICE"
3. BE SURE VALVE DRAIN HOSE RUNS DIRECTLY TO AN ACCEPTABLE DRAIN POINT, AND IS NOT PINCHED, KINKED OR ELEVATED TOO HIGH IF RUN OVER- HEAD. DID YOU PROVIDE AN AIR-GAP AT THE DRAIN POINT?
HARD WATER TO HOUSE
WATER METER
MAIN SHUTOFF
VALVE
For answers to your Monogram,®GE Profile Performance Series,™GE Profile,™GE, Hotpoint and RCA appliance questions, call GE Answer Center®service, 800.626.2000.
Revised 7/97