GE LED Roadway Scalable Project Grade Cobrahead Installation Guide

GE
Lighting
Evolve
Scalable Fixtures (ERS3 & ERS4)
BEFORE YOU BEGIN
Read these instructions completely and carefully. Save these instructions for future use.
Risk of electrical shock. Disconnect power before servicing or installing product.
Risk of injury or damage. Unit will fall if not installed properly. Follow installation instructions.
Risk of injury. Wear safety glasses and gloves during installation and servicing.
LED Roadway Light
CAUTION
Installation Guide
GEH-6012B
• This luminaire is designed for outdoor lighting service, and should not be used in areas of limited ventilation, or in high ambient temperatures.
• Best results will be obtained if installed and maintained according to the following recommendations.
• Luminaire is designed to operate in ambient temperatures ranging from -40°C to +50°C (-40°C to +45°C for ERS4 347-480V fixtures) and to be mounted horizontally to a vertical pole with LEDs facing down, as shown.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
imagination at work
SPECIFICATIONS
• Weight: Maximum weight ERS3 - ERS4: 40 to 46 lbs. (18.14 to 20.87 kg.)
• IP Rating: Optical IP65, Standard Electrical Enclosure: UL 1598 Wet Location Rated
• Dimensions: L x W x H ERS3 - ERS4: 37.3 in. x 15.0 in. x 5.4 in.
(947mm x 380mm x 137mm)
• IEC Fixture Rating: IP44
• Mounting Height: 27 - 40 ft. (8.2m - 12.2m)
• EPA: ERS3- ERS4 : 1.0 ft2
UNPACKING
1
• This luminaire has been properly packed so that no parts should have been damaged during transit.
• Inspect to confirm.
HANDLING
2
• Damage may occur if luminaire is improperly handled outside of pack.
• Do not impact or stack luminaire after removal from packaging.
MOUNTING
3
• Luminaire must be mounted on 2-inch (50.8mm) diameter mounting arm.
CAUTION
Risk of injury.
prolonged staring into the luminaire at a distance closer than
0.50m is not expected.
The luminarie should be mounted so that
Risk of injury. Do not rely on door latch to hold power
module door during installation/maintenance. The door latch is provided only to aid in the fastening of the captive screw.
INSTALLATION
4
Installation to Mounting Arm:
Installation to Mounting Arm for Luminaire with 4 Slip fitter Bolts and One Bottom Door:
• Remove Power door by loosening captive screw, releasing the door latch and opening door to a vertical position.
• Disconnect plug which connects top housing wiring with ballast and plug which connects to LED optical assembly.
• Now grasp door securely in both hands and open door further until it comes free from hinges in top housing.
• This occurs at approximately 35 degrees from vertical on pole side of hinge. In this position hinge pins will easily slide upward out of their hinge cradles in top housing.
• If necessary, adjust 4 pipe clamp bolts such that opening is slightly larger than mounting pipe diameter.
• The luminaire may be adjusted up or down with
respect to pipe.
• A pad is provided on top of housing for convenient
application of hand level.
• To mount, insert pipe into back of the luminaire until it
hits the leveling steps or stop that sticks down from the top of housing.
• Hold luminaire approximately level and snug up bolts
(4-5 foot-pounds).
• If more upward tilt of front of luminaire is needed, first loosen front two bolts slightly, lift luminaire and re-snug the back two.
• If downward tilt is needed, reverse procedure by loosening back two bolts first.
• Once proper level has been achieved, tighten each bolt to 17-19 foot-pounds (23.05-25.76 N-m), alternating front to back along diagonal of bracket as shown in Figure 1.
IEC Units:
• Terminals are readily accessible on terminal board
and will accept service leads ranging in size from AWG No. 16 through No. 6.
• Service leads (See fixture labeling for supply wire
temperature rating) should extend through mounting bracket approximately 7 inches.
• Attach service leads to terminal board as shown on
luminaire nameplate.
• See table below for screw torques (See Table 1).
• Dimming Control Connections (See Table 2).
• A wiring diagram is provided on a label in luminaire.
TABLE 1. Terminal Board Torque Table UL Units Wire Range Copper Aluminum Torque (in lbs)
10 - 16 SOL, STR 30 8 - 6 SOL, STR STR6 SOL, STR 45
FIGURE 1
Under no conditions should bolts be torqued to level greater than
20 ft-lbs. (27.17 N-m)
CAUTION
Risk of injury. LED light source achieves full intensity
immediately upon being powered on. Do not look directly at LED light source while energized.
WIRING
5
NOTE: Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements including grounding.
TABLE 2. Dimming Control Connections
O VDC (-) Gray Lead Up to 10 VDC (+) Violet Lead
IEC Units:
• Power supply cable and dimming control cable (if
necessary) must be provided by customer.
• Power supply cable (each conductor: phase, neutral
and ground) should be maximum of 12AWG (2.5mm2) and minimum of 16 AWG (1.5mm2) solid or with an overall cable diameter within the range of 7-12mm.
• Dimming control cable (0 to 10 VDC) (each conductor:
positive and negative) should be 18 AWG (1.0mm2) solid or stranded with an overall cable diameter within the range of 5-10mm.
Terminal Board Connections:
Terminal Board Position Supply Type L1 High Line G Ground N/L2 Low Line/Neutral
stranded
NOTE: Verify that supply voltage is correct by comparing it to nameplate.
PHOTOELECTRIC CONTROL
6
• When used, photoelectric (PE) receptacle should be
oriented so that the word “North” is directed toward true north.
• This is done by seating a PE control into receptacle, lifting upward on PE control (which will lift PE receptacle also), and rotating them clockwise until word “North” is directed toward true north.
• If door is to be assembled to top housing while lying
on its back, extreme care should be taken to ensure that hinge pin is properly engaged in the cradle by
lifting up rear of door. Otherwise, breakage may occur.
• Then lower PE control and receptacle to firmly seat them into position. No tools are required to make this adjustment.
• Alternatively, PE receptacle can be oriented before PE control is installed.
• This is done by lifting up on rim of the PE receptacle and rotating it until the word “North” is directed toward true north.
• Lower PE receptacle to firmly seat it in this position. Then install PE control.
FINAL ASSEMBLY POWER
7
MODULE DOOR
• To replace door, hold it at an angle of approximately 35 degrees from vertical and toward pole side of hinge.
• Carefully insert hinge pin into hinge and allow door to hang free.
• Note that door is mechanically interlocked with top housing in all positions except in the vicinity of removal location.
MAINTENANCE / CLEANING
8
• To maintain high efficiency of the lens, occasional
cleaning of the outer lens surface may be needed, with frequency dependent on local conditions.
• Use a mild soap or detergent, which is essentially
neutral pH (pH approximately 6 to 8), nonabrasive, and which contains no chlorinated or aromatic hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
STORAGE
9
• Prior to installation, units should NOT be stored
outside in corrugated boxes (cardboard boxes) alone.
• Until installation, all units should be placed in a
covered dry storage area. The storage area should not exceed -40°C (-40°F) to 50°C (122°F).
- This can be preferably in a roofed area or with a
tarp that is secured in such a way to keep water off of the corrugated boxes (cardboard boxes).
• All units: The doors are designed to be assembled to top housing while in upright position with gravity holding hinge pin properly in the cradle.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting.
GE Lighting • 1-888-MY-GE-LED • www.gelighting.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting, LLC is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company. © 2014 GE Lighting, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
35-201578-204 (Rev 09/09/14)
English
GE
Guide d’installation
Lighting
Luminaire routier à DEL Evolve
Appareils d’éclairage évolutifs (ERS3 & ERS4)
GEH-6012B
ARRÊT
AVANT DE COMMENCER
Lisez attentivement toutes ces instructions. Conservez ces instructions pour référence future.
AVERTISSEMENT
Risque de choc électrique. Déconnectez l’alimentation
électrique avant d’installer ou réparer ce produit.
AVERTISSEMENT
Danger de blessure et de dommage matériel. L’appareil
tombera au sol s’il est mal installé. Suivez les instructions d’installation.
ATTENTION
Danger de blessure. Lors de l’installation et de la réparation
de cet appareil, porter des lunettes et des gants de sécurité.
Cet appareil est en conformité avec les règlements de la FCC, Part 15. Son opération est sujette aux deux conditions suivantes : (1) Cet appareil ne peut pas causer d’interférences nuisibles, et (2) Cet appareil doit accepter toute interférence reçue, y compris les interférences qui pourraient causer un fonctionnement indésirable. Cette Classe [A] RFLD satisfait la norme Canadienne ICES-003. Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
• Ce luminaire a été conçu pour une utilisation à l’extérieur et ne doit pas être employé sur un site mal ventilé ni dans un endroit clos où la température ambiante peut être élevée.
• Pour obtenir des performances optimales, il doit être installé et entretenu conformément aux recommandations suivantes.
• Ce luminaire a été conçu pour fonctionner sous des températures ambiantes de -40 ºC à +50 ºC (-40 °C à +45° C pour appareils d’éclairage ERS4 sous 347-480 V). Il doit être installé à l’horizontale sur un poteau vertical, avec les lampes à DEL tournées vers le bas, conformément à l’illustration.
Remarque : Cet équipement a été testé et prouvé être en conformité avec les limites d’un appareil digital de Classe A, suivant la Part 15 des règlements de la FCC. Ces limites sont établies pour assurer une protection raisonnable contre les interférences nuisibles lorsque l’équipement est mis en service dans un environnement commercial. Cet équipement émet, utilise et peut radier une énergie de radio fréquence et, s’il n’est pas installé et utilisé suivant les instructions du manuel, pourrait causer des interférences nuisibles aux communications radio. L’opération de cet équipement dans une zone résidentielle va probablement causer des interférences nuisibles auquel cas l’utilisateur a l’obligation de corriger le problème à ses propres frais.
-
imagination at work
SPÉCIFICATIONS
• Poids : Poids maximal ERS3 - ERS4 : 18,14 à 20,87 kg (40-46 lb)
• Classification IP : Module optique IP65, boîtier électrique standard : Homologation UL 1598 pour environnement mouillé
• Dimensions : Lo x La x H ERS3 - ERS4 : 947 mm x 380 mm x 137 mm (37,3 po x 15,0 po x 5,4 po)
• Classe de l’appareil : IEC IP44
• Hauteur de montage : 8,2 m – 12,2 m (27-40 pi)
• EPA : ERS3 - ERS4 : 1,0 pi