LED 55 CC 1.4A ESRDL 1-10V 220-240 Infusion System Power Supply
Power Supply Installation
Tighten the screws (x4) until the CAP goes down all the way and reaches the BASE.
BEFOR YOU BEGIN
Read these instruction completely and carefully
CAP
BASE
CAP
Page 2
Page 2 of 6
Imagination at work
Power Supply Installation LED 55 CC 1.4A ESRDL 1-10V 220-240
PRIMARY SIDE – CHANNE L #1
OPTION – 1 OPTION – 2
WIRE TABLE
mm2 CABLE
CHANNEL#1 – OPTION - 1 2X0.75mm2 – 2X1mm
2
H05VVH2-F, SALCAVI-LSF
R30268
CHANNEL#1 – OPTION - 2 0.75mm2 H03VV-F
CHANNEL #1
CHANNEL #2
CHANNEL #4
CHANNEL #3
PRI SIDE
TOP VIEW
SEC SIDE
Page 3
Page 3 of 6
Imagination at work
Power Supply Installation LED 55 CC 1.4A ESRDL 1-10V 220-240
PRIMARY SIDE – CHANNE L #2
OPTION – 1 OPTION – 2
WIRE TABLE
mm2 CABLE
CHANNEL#2 – OPTION - 1 0.75mm
2
LEONI-H03VVH2-F
CHANNEL#2 – OPTION - 2 0.75mm2 -
CHANNEL #1
CHANNEL #2
CHANNEL #4
CHANNEL #3
PRI SIDE
TOP VIEW
SEC SIDE
Page 4
Page 4 of 6
Imagination at work
Power Supply Installation LED 55 CC 1.4A ESRDL 1-10V 220-240
SECONDARY SIDE – CHANNEL #3 & CHANNEL #4
CHANNEL #3 – LED & FAN CHANNEL #4 - DIM
WIRE TABLE
AWG
CHANNEL#3
LED
18
LED and FAN wires come as bundle­inserted into a heat shrink sleev e.
FAN 18-24
CHANNEL#4 - DIM 18 -
CHANNEL #1
CHANNEL #2
CHANNEL #3
PRI SIDE
TOP VIEW
SEC SIDE
TO FAN
TO LED
Page 5
Page 5 of 6
Imagination at work
LED 55 CC 1.4A ESRDL 1-10V 220-240 Dimensions
Power Supply Specifications
Performance Data Min Typical Max
Input Voltage (VAC) 198 220-240 264 Input Frequency (Hz) - 50/60 ­Input Current (A) - - 0.4 Output Voltage(VDC) LOAD 15 - 40 Output Current(ADC) 1.3 1.4 1.5 Output Power(W) - - 55
Environmental Operating Temperature Range
-20°C - +50°C
Environmental Humidity(non-condensing) - - 80% Environmental Storage Temperature
Range
-10°C - +70°C
Dimming 1-10 (VDC) 1 - 10 Output Current Dim (ADC) 0.1 - 1.5 Fan Output Voltage (VDC) - 12 ­Fan Output Power (W) - - 2
Page 6
Page 6 of 6
Imagination at work
Safety Instructions:
1. Always disconnect power before installation and/or removal of the unit.
2. Install in accordance with national and local electrical codes.
3. Wire: for input use cable according to VDE standard 0285-5.
Safety Instructions Safety Instructions
English,,Dutch,French,German,Hungarian,Italian,Norwegian,Russian,Spanish,Swedish,Polish,Arabic,Danish, Belgian,Austrian and Finish versions of the installation instructions and safety information can be found at the following location www.gelighting.com/LightingWeb/emea/resources/document-library
GE Lighting Solutions
www.gelighting.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.