3?
—
—
-
ImpormntS:fety
Beforeusingyourair
conditioner, readthisbook
carefully.
Itis intendedtohelpyouoperate
andmaintainyour newair
conditionerproperly.
Keepithandyforanswerstoyour
questions.
Ifyoudon’tunderstandsomething
orneedmorehelp,write(include
yourphonenumber):
ConsumerAffairs
Hotpoint
AppliancePark
Louisville,KY40225
Writedownthemodel
andserialnmbers.
You’llfindthemona labelbehind
thefrontgrilleonthelefi-handside
oftheairdischargeduct. Seepage6.
Thesenumbersare alsoonthe
ConsumerProductOwnership
RegistrationCardthatcamewith
yourairconditioner.Beforesending
inthiscard,pleasewritethese
numbershere:
ModelNumber
SerialNumber
Ene~y”saving
~Keeptheair filterclean.(See
instructionsonpage6.)
oFormostefficientcooling,keep
theventilationcontrolintheclosed
positionexceptwhenyouwantto
exhaustair, smokeor odorsfrom
theroom.
oDon’tlet theroomgettoo
hot.Wheneverpossible,turnthe
unit onbeforetheroomheatsup.
Whenheatis “storedup”inwalls,
furniture,rugsanddraperies,your
airconditionertakeslongerto
producethedesiredcomfort
condition.
@Keepwindowsanddoors
closed.Cool,dryair escapes
whenthey’reopen.
e Keepfurnacefloorregistersand
coldairreturnsclosed.Coldair
caneasilyescapethroughthem.
e Don’tletdrapesor firnitureblock
thefrontoftheunitandrestrictair
flowwhenitis operating.
eIt’sbesttooperateyourair
conditionerat highspeedduring
extremelyhotweather.
eKeeptheoutdoorcondensercoil
clean.(Seepage6.)
oTurntheair conditioneroff
beforevacationsor extended
absencesfromhome.
tips
o
Usethesenumbersinany
correspondenceor servicecalls
concerningyourairconditioner.
Ifyoureceivedadamaged
airconditioner...
Immediatelycontactthe dealer
(orbuilder)thatsoldyoutheair
conditioner.
Savetimeandmoney.
Beforeyourequest
service...
ChecktheProblemSolveron
page7.It listscausesofminor
operatingproblemsthatyoucan
correctyourself.
.
Howtoconnect
—
electricity
—
Forprsonal safety,
—
thkappliancemm be
properBygrounded.
Electricalrequirement
H5-voItmodelsrequirea 115/120-
volta.c., 60hzgroundedoutlet
protectedwitha 15amptimedelay
fise or circuitbreaker.
Thepowercordonthesemodelshas
athree-prong@rounding)plugthat
mateswitha standardthree-prong
(grounding)walloutlet(Fig.1)to
minimizethepossibilityofelectric
shockhazardfromtheseappliances.
PREFERRED
METHOD
iNSUREPROPER
GROUNDEXISTS
Fig.
1
Wherea standardtwo-prongwall
outletisencountered,itis your
personalresponsibilityandobligation
to haveitreplacedwitha properly
groundedthree-prongwalloutlet.
DO N~, WER Am ‘~
CRCWQT~CES, CUT
oRmMom Tm THmb
(GRO-) PRONG~OM ~
T~ POWERCOm.
230/208-voltmodelsrequiretheir
ownsinglebranchcircuitsupplying
230/208-volta.c., protectedwitha
timedelayfise or circuitbreaker.
Thisisrecommendedforbest
performanceandtoprevent
overloadinghousewiringcircuits,
whichcouldcauseapossiblefire
hazardfromoverheatingwires.
The powercordonthesemodels
hasa230/208-voltperpendicular,
tandemor largetandemtypeplug
thatmatesrespectivelywitha
BEFOREUSE
230/208-voltperpendicular,
tandemor large&ndemtype wall
outlet.Thesetypesofoutletsare
availableat mosthardwarestores.
230/208-voLT MATCHING
PERPENDICULAR
LINE CORD PLUG
REQUIRES 20AMP TIMEDELAYFUSE
OR CIRCUIT BREAKER PROTECTION
230/208-VOLT
TANDEMTYPE
LINE CORD PLUG
REQUIRES 15AMP TIMEDELAY FUSE
OR CIRCUIT BREAKER PROTECilON
TYPE WALL OUTLET
WALL OUTLET
o
—
MARHING
mm
(’
(
@
—-
@o
230/208-VOLT MATCHING
LARGE TANDEMTYPE WALL OUTLET
LINE CORD PLUG
REQUIRES 30AMP TIME DELAYFUSE
OR CIRCUIT BREAKER PROTE~lON
Whetheryourairconditioneris a
~5-voltora 230/208-voltunit,it
isimportantto havethewall
outletandcircuitcheckedbya
qualifiedelectricianif thereis
anydoubtastowhetheraproper
groundexists.
ofatipkr plug
Use
(~-volt modekonly)
Becauseofpotentialsafetyhazards
under certainconditions,we
stronglyrecommendagainstuse
ofanadapterplug.However,
ifyoustillelecttousean adapter,
wherelocalcodes permit,a
TEMPORARYCC)NNE~ION
maybemadetoa properlygrounded’
two-prongwalloutletbyuseofa
ULlistedadapter(Fig.2)available
atmostlocalhardwarestores.
e
TEMPORARYMETHOD
(ADAPTERPLUGS
PERMITTED IN CANADA)
Fig. 2 “‘
Thelargerslotintheadaptermustbe
alignd-withthelargerslotinthe wall
outlettoprovideproperpolarityin
theconnectionofthepowercord.
CA~ION: Attachingtheadapter
groundterminalto walloutletcover
screwdoesnotgroundtheappliance
unlesscoverscrewismetal,andnot
insulated,andwalloutletisgrounded
throughhouse wiring.Youshould
havethecircuitcheckedbyaqualified
electriciantomakesuretheoutlet
isproperlygrounded.
whendisconnectingthepowercord
fromtheadapter,alwaysholdthe
adapterwithone hand.If thisisnot
done,theadaptergroundterminalis
verylikelytobreakwithrepeateduse.
Shouldtheadapterground
terminalbreak,DON~ USEthe
applianceuntila properground
hasagain beenestablished.
NOT
h
BEFOREUSE
Useofe~ewion corm
Becauseofpotentialsafety
hazardsundercertainconditions,
westronglyrecommendagainstthe
useofanextensioncord.However,
ifyoustillelecttouseanextension
cord,itis absolutelynecessarythat
itbea ULlisted3-wiregrounding
typeapplianceextensioncordand
thatthecurrentcarryingratingof
thecordin amperesbeequal to or
greaterthanthebranchcircuit size
shownontheratingnameplateof
theappliance.Suchextensioncords
areobtainablethroughyourlocal.
serviceorganization.
—.
—-
3