GE JNM7196BL, JNM7196SKSS, JNM7196BLTS, JVM7195SK, JVM7195EK Dimensions And Installation Information

...
Listed by Underwriters Laboratories
JNM7196SK/BL
GE® 1.9 cu. ft. Over-the-Range Sensor Microwave Oven with Recirculating Venting
Specif ication Revis ed 6/17
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
For answers to your Mon ogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
NOTE: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above microwave oven. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the microwave oven.
IMPORTANT INFORMATION: When installing the microwave oven over a range, allow minimum of 2" from bottom of microwave oven to top of range backguard to allow for removal of light covers.
VENTILATION OPTIONS: The microwave ovens are designed for adaptation to the following three types of ventilation:
-Outside exhaust (vertical – as shown)
-Outside exhaust (horizontal)
-Recirculating (non-vented ductless – see Filter Kit drawing)
INSTA LL ATIO N I N FOR M AT ION: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Listed by Underwriters Laboratories
JNM7196SK/BL
GE® 1.9 cu. ft. Over-the-Range Sensor Microwave Oven with Recirculating Venting
Specif ication Revis ed 6/17
Filler Panel Kit JX36DSS/DTS
When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between cabinets only; not for end­of-cabinet installation. Each kit contains two 3"-wide filler panels.
Filter Kit JX81H– Recirculating Charcoal Filter Kit To be used when the microwave oven cannot be vented to the outside.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
For answers to your Mon ogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
DUCT EQUIVALENT FEET A. Rectangular-To-round
Transition Adaptor 5 ft.
B. Wal l Ca p 40 ft. C. 90° Elbow 10 ft . D. 45° Elb ow 5 ft. E. 90° Elbow 25 ft. F. 45° Elbow 5 ft. G. Roof Cap 24 ft.