For long vacations or absences, set both power switches
(on the back of the dispenser, if equipped) to the
O (off)
position.
1. Unplug the water dispenser.
2. Remove the water bottle.
3. Drain the water tanks (see
Draining the Dispenser
).
4. Dry the separator thoroughly on both the top and bottom
(see
Cleaning the Separator
).
5. Leave the door of the chiller compartment open.
After returning from vacation, make sure to sanitize the water tanks
before using the dispenser (see Cleaning and Sanitizing the Water Tank).
Preparing for Vacation
Chilling Rate:
approx. 0.5 gallons (2 liters) per hour
Heating Rate:
approx. 0.8 gallons (3 liters) per hour
Capacity:
3 or 5 gallon bottle
Power Consumption:
Heating: 480 watts max.
Cooling: 125 watts max.
Specifications
Defrosting (for models GXCF25FBS, GXCF25HBS and PXCR33KSS)
Defrost whenever frost on the wall of the chiller compartment becomes
excessive. Never use a sharp or metallic instrument to remove frost
as it may damage the liner. We recommend using a plastic scraper.
Do not use any electrical device in defrosting your chiller compartment.
To defrost:
■ Remove items from the compartment.
■ Turn the Cold (Blue) Power switch (if equipped) to off
and unplug the dispenser.
■ Put several towels in the bottom of the compartment
to collect water.
Defrosting usually takes a few hours. To defrost faster,
keep the door open.
After defrosting:
■ Remove the wet towels and wipe up any remaining water.
■ Wipe the compartment with a dry cloth.
■ Plug in the unit and turn on the Cold (Blue) power switch
(if equipped). Return items to the unit.
Troubleshooting Tips.
Problem Possible Causes What To Do
Water has poor taste
Separator needs cleaning. •See
Cleaning the Separator.
or odor
Unit needs to be sanitized. •See
Cleaning and Sanitizing the Water Tanks.
Water not hot enough
Dispenser is unplugged. •Push the plug completely into the outlet.
or cold enough
The fuse is blown/circuit •Replace house fuse or reset the house circuit breaker.
breaker is tripped. •If too many items are plugged into a single circuit,
move some items to a different circuit.
All the water in the water tank •Wait 30 minutes for water to heat or cool.
has been used.
Temperature limiter tripped. •Set the hot and cold power switches (on the back of the
dispenser, if equipped) to the
O (off)
position. Wait 5 minutes;
then set the switches to the
I (on)
position. Unplug unit for 5
minutes if model does not have separate power switches. Wait 30
minutes for water to heat or cool.
Water dispenser does
Empty water bottle. •Replace with a new bottle of water.
not work—No water flow
Mineral deposits clogging tanks. •See
Care and Cleaning
.
Cold water button
Chiller door has been left open. •Close chiller door.
does not dispense
Ice buildup blocking water flow. •Turn off cold power switch (if equipped) or unplug unit
overnight. Once water can be dispensed from faucet, plug unit
back in or turn cold power switch back to the ON position.
Water dispenser leaks
Crack or pin hole in bottle. •Replace with a new bottle of water.
from the outside
Compressor does not
Normal Operation—Compressor •Wait for up to 3 minutes for the compressor to start.
start when unit is plugged
start may be delayed by up to
in and cold power switch
3 minutes (on certain models) to
(if equipped) is on
prolong the compressor life.
Care and cleaning of the dispenser.
8