Ge GX1S50R User Manual

GEAppliances.com
Water Filtration System
215C1219P002 49-50235-4 09 -09 JR
GX1S50R
Owner’s Manual and
Installation Instructions
Safety Instructions
. . . . . . . . . . . . . . . . . .2
Installation Instructions . . . . . . . . .5–9
Battery Installation . . . . . . . . . . . . . . . . . . . . . . .8
Faucet Installation . . . . . . . . . . . . . . . . . . . . .6, 7
Filter Replacement . . . . . . . . . . . . . . . . . . . . . . .9
Flush Procedure . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installing the Tubing . . . . . . . . . . . . . . . . . . . . . .8
System Installation . . . . . . . . . . . . . . . . . . . . . . .7
Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . .5, 6
Troubleshooting Tips . . . . . . . . . . . . . . .10
Consumer Support . . . . . . . . . . . . . . . . .12
Manuel d’utilisation
et d’installation
Manual del propietario
y instalación
La section française commence à la page 13
Système de
filtration d’eau
La sección en español empieza en la página 25
Sistema de
filtración de agua
GX1S50R is Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class I and Standard 53 for the reduction of Lead, Cyst, Turbidity, Asbestos, Mercury, Lindane and Atrazine.
This product has been tested and Certified by WQA according to CSA B483.1.
2
IMPORTANT SAFETY INFORMATION.
WARNING:
Read entire manual. Failure to follow all guides and rules could cause personal injury or property
damage.
Check with your local public works department for plumbing codes. You must follow their guidelines as you install the Water Filtration system.
SAFETY PRECAUTIONS
Use the Water Filtration system on a potable, safe-to-drink, home COLD water supply only. The filter canister will not purify the water, or make it safe to drink.
Do not use on a hot water supply (100°F max.). Install on cold water line only.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
PROPER INSTALLATION
This Water Filtration system must be properly installed and located in accordance with the Installation Instructions before it is used.
CAUTION: To reduce the risk of property damage due to water leakage, install or store where it will not be exposed to
temperatures below freezing or exposed to any type of weather. Water freezing in the system may damage it and may result in water leakage, damaging property. Change filter out if it was exposed to freezing temperatures. Do not attempt to treat water over 100°F.
WARNING: Discard all unused and packaging material after installation. Small parts remaining after installation could
be a choke hazard.
Your Water Filtration system will withstand up to 120 pounds per square inch (psi) water pressure. If your house water supply pressure is higher than 80 psi, install a pressure reducing valve before installing the Water Filtration system.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
3
Specifications Guidelines.
Many bad tastes and/or odors are reduced from water using activated carbon filter canisters. They are most often used to reduce a chlorine taste and odor. They can also reduce other undesirable elements from drinking water supplies, such as organic chemical contaminants and lead.
NOTE: Small amounts of hydrogen sulfide (noticeable as “rotten egg” odor) may be reduced by taste and odor filters for a short time, but the carbon media is quickly exhausted. Other water conditioning equipment is usually required for the continuous treatment of hydrogen sulfide.
The Water Filtration System Uses the Following Canister
Model GX1S50R
GXRLQR Filter (750 gallon capacity) Filter—White canister with yellow band
Reduces dirt, rust and sediment
Reduces Chlorine Taste and Odor
Reduces Lead
Reduces filterable Cysts (such as cryptosporidium and giardia)
Reduces Turbidity
Reduces Asbestos
Reduces Mercury
Reduces Lindane
Reduces Atrazine
0.5–1 micron nominal particulate reduction
This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and sustained by test data. See Performance Data Sheet for details.
Installation Overview
Locate the drinking water system on the cold water supply pipe, under the kitchen and/or bathroom sink, to filter the cold drinking water.
Sink
Hot Cold
Water Supply Valve
Filtered Water Faucet
Inlet
Outlet
Filter Canister
Manifold
Performance Data Sheet.
SmartWater Filtration System GX1S50R Using Filter GXRLQR
This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Actual performance may vary with local water conditions.
WARNING:
Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Standard No. 42: Aesthetic Effects
USEPA Influent Influent
Effluent % Reduction
Min. Required
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction
Chlorine taste and odor
2.0 mg/L +10% 2.00 mg/L 0.050625 mg/L 0.06 mg/L 97.52% 97.00% >50%
Nominal Particulate** ≥ 1 0,000 particles/mL 14,000,000 #/mL 196,666 #/mL 370,000 #/mL 99.00% 97.40% >85%
Standard No. 53: Health Effects
USEPA Influent Influent
Effluent % Reduction
Min. Required
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction
Turbidity 0.5 NTU*** 11 + 1 NTU*** 10.5 NTU 0.125 NTU 0.30 NTU 98.80% 97.30% 0.5 NTU Cysts 99.95% red. Min. 50,000L 122,500 #/L <1 <1 >99.99% >99.99% >99.95% Asbestos 99% red. 10
7
and 108fibers/L; 126.5 MF/L <.17 <.17 >99.99% >99.99% >99%
fibers >10 μm long Lead, pH 6.5 0.010 mg/L 0.015 mg/L + 10% 0.150 mg/L <0.001 <0.001 >99.30% >99.30% 0.010 mg/L Lead, pH 8.5 0.010 mg/L 0.015 mg/L + 10% 0.150 mg/L <0.001 <0.001 >99.30% >99.30% 0.010 mg/L Mercury, pH 6.5 0.002 mg/L 0.006 mg/L ± 10% 0.006 mg/L 0.0003 0.0005 95.00% 91.70% 0.002 mg/L Mercury, pH 8.5 0.002 mg/L 0.006 mg/L ± 10% 0.0059 mg/L 0.00073 0.0018 88.10% 69.20% 0.002 mg/L Atrazine 0.003 mg/L 0.009 mg/L + 10% 0.0102 mg/L 0.00105 0.0027 89.40% 76.30% 0.003 mg/L Lindane 0.0002 mg/L 0.002 mg/L + 10% 0.0019 mg/L 0.000035 0.00016 97.90% 91.80% 0.0002 mg/L
*Tested using a flow rate of 0.78 gpm (2.95 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) **Measurement in particles/mL. Particles used were 0.5–1 microns. ***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 750 gallons (2,838 l); up to six months Pressure requirement: 35–120 psi (2.8–8.2 bar) Temperature: 33–100°F (0.6–38°C) Flow rate: 0.78 gpm (2.95 l/min)
4
Replacement Filter Canister/Estimated Replacement Costs
GXRLQR—Replacement filter canister $30–35 For replacement parts, call toll-free 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French)
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued: December 15, 2008
Trademark/Model Designation
Replacement Elements
1952
08 -
GE SmartWater GX1S50R GXRLQR
Manufacturer: GE Appliances
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:
Cysts Turbidity
Asbestos Lead Mercury
Atrazine Lindane
Microbiological Contaminants and Turbidity
Inorganic/Radiological Contaminants
Organic Contaminants
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
750 galRated Service Capacity: 0.78 gpm
Rated Service Flow:
GE SmartWater GXRLQ GXRLQR
5
Installation
Faucet Mount Filtration System –
Instructions
GX1S50R
IMPORTANT INSTALLATION RECOMMENDATIONS
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.
Check with your local public works department for plumbing codes. You must follow their guides as you install the Water Filtration system.
TOOLS AND MATERIALS REQUIRED FOR INSTALLATION
• Phillips screwdriver
• Two (2) adjustable wrenches
• Electric drill and drill bit to drill 1hole (type as
required) if mounting hole is needed for faucet
• If your main water line is a rigid pipe, you will require
a compression fitting and possibly other plumbing hardware to complete the installation.
CAUTION
To avoid damaging the sink, consult a qualified plumber or installer for drilling procedures. Special drill bits may be needed for porcelain or stainless steel.
CONTENTS INCLUDED WITH THE PRODUCT
• Water filter system assembly, including mounting
screw and double-sided tape
• Feed water adapter
• Faucet assembly with electronic base monitor
and tubing
COLD WATER SUPPLY FITTING
A. PREFERRED INSTALLATION
(Utilizing existing kitchen sink water supply valve and flexible faucet tubing)
A typical connection using the included water supply fitting is shown in the illustration below.
1. Close the water shut-off valve that is immediately
in front of the supply tube and open the faucets to drain water from the sink cold water pipe.
2. Remove the nut that connects the cold water faucet
to the supply tube. Some water may spill out.
NOTES:
• Be sure to turn off the water supply and open a faucet to drain the pipe.
• Make sure the gasket is installed in the water supply fitting.
3. Hand-tighten the water supply fitting onto the cold water faucet. Be sure the gasket, as shown, is in place before final assembly. Finish tightening with an adjustable wrench. Be careful not to overtighten
or cross-thread, as damage to the threads can occur. Make sure the 1/4quick connection is not
against a wall that causes the supply tubing connection to bend. A quarter turn to tighten or loosen the adapter may be necessary to avoid this.
4. Reconnect faucet tubing line to the fitting.
5. Install tubing. (See Installing the Tubing section.)
Cold Water Faucet Stud
Cold Water Pipe
Water Supply Fitting
1/4Tubing to Water Filter Inlet
Cold Water Shutoff
Gasket
Fig. 1
Installation Instructions
6
COLD WATER SUPPLY FITTING (CONT.)
B. OPTIONAL HOME INSTALLATION
(Where codes permit)
Saddle Valve: Saddle valve must be able to connect with 1/4-inch tubing supplied with the system. Not supplied with product; check your local hardware or home service store for product. Saddle valve typically requires 1/2 OD tubing or larger.
NOTE: Codes in the state of Massachusetts require installation by a licensed plumber and do not permit the use of the saddle valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
1. Turn off the cold water supply and install saddle
valve as required by product selection. (Be sure to follow manufacturer’s installation instructions.)
DANGER
If hole is required to be drilled in pipe, to protect yourself from serious injury or fatal shock, use a battery-powered hand drill only to make the hole. DO NOT USE AN ELECTRIC DRILL.
2. Open saddle valve after complete system has
been installed.
C. OPTIONAL INSTALLATION
(For installation with rigid pipe between supply valve and sink faucet)
Option 1
1. Remove pipe from supply valve and sink faucet.
2. Obtain flexible pipe sized to your plumbing.
3. Install flexible pipe.
4. Go back to A. Preferred Installation section
step 3.
Option 2
1. Obtain compression fittings to fit rigid pipe.
2. Obtain any other fittings required to connect
compression fittings to feed water adapter.
3. Remove pipe from supply valve.
4. Cut pipe to fit length of assembled fittings and
adapter.
5. Install compression fitting to pipe.
6. Go back to A. Preferred Installation section
step 3.
NOTE: Above described materials are not included with the product.
INSTALL THE FAUCET
Be sure there is room underneath and above the sink to make the needed connections. Before starting, make sure there is sufficient room for the faucet base and unit. Select one of the following places to install the faucet:
A. In an existing sink spray attachment or soap
dispenser hole.
B. In a hole to be drilled in the sink top. C. In a hole to be drilled in the countertop, next
to the sink.
NOTES:
• Be sure the faucet base will fit flat against the surface at the selected location so the bottom gasket between the base and surface area will seal.
• Make sure to leave enough clearance at the back of the faucet in case you need to remove it.
Installation Steps (refer to illustration below for clarification)
1. If drilling is needed, make a 1diameter hole.
Be sure to use the proper procedure for drilling porcelain or stainless steel. Special drill bits may be needed. Consult a qualified plumber for the proper procedure.
CAUTION:When drilling in Stainless
Steel, the edges may be sharp and could puncture the tube. Be careful to not cut yourself or damage the tube.
2. Remove the faucet body and base by turning
the base counterclockwise.
3. Remove the butterfly bracket from the screw.
Then insert the screw into the top of the base and reattach the butterfly bracket.
4. Align the gasket to cover the hole completely.
Then place the butterfly bracket on the base into the hole.
5. Tighten the screw to secure the butterfly bracket
to the underside of the sink top. The base should be firmly in place and should not wobble or turn.
Base
Sink
Gasket
Butterfly Bracket
Screw
Installation Instructions
7
INSTALL THE FAUCET (CONT.)
6. Feed the water tube up through the faucet base.
Then push the tube into the fitting on the bottom of the faucet body. It should go in about 3/4″. Pull tube slightly to make sure it is secure.
7. Push the faucet body down into the faucet base
and twist clockwise until it clicks into place. NOTE: You can install the faucet so the handle
is on the right or the left side. If you want the faucet handle on the right,
position the handle at the back of the faucet base before turning clockwise.
If you want the faucet handle on the left, position the handle at the front of the faucet base before turning clockwise.
8. Locate the hole at the rear of the base. Insert
set screw and begin to tighten by hand. Finish tightening with the Allen wrench provided in the packet.
Faucet Body
Base
Sink
Gasket
Toggle Screw
Faucet Faucet
Faucet handle on the RIGHT Faucet handle on the LEFT
MOUNTING SYSTEM INSTALLATION
Pick a location under the sink to mount the system. Location should be easily accessible, with at least 5 inches of clearance between the bottom of the filter canister and the floor or bottom of the cabinet; any less will result in difficulty of removing filter canister. Allow enough space on either side of the system for the tubing connections.
A. PREFERRED INSTALLATION (Mounting Using the Screw Provided [Fig. 4])
1. Remove shrink wrap from filter system.
2. System should be mounted to a stud in the wall
or solid firm surface.
3. Use the screw (B) provided to mount through the
screw hole in the center of the manifold (A). (Pre-drill a 1/16pilot hole, if needed). NOTE: If mounting to drywall, with no stud, a drywall anchor (not included) must be used.
B. OPTIONAL INSTALLATION (Mounting Using the Mounting Tape Provided [Fig. 5])
(If mounting to drywall, the screw must be used also).
1. Remove shrink wrap from filter system.
2. Clean wall surface to remove any dirt, oil or grease
and dry thoroughly.
3.
Using the double-sided mounting tape provided (C), remove one side of the protective wax paper and apply the entire piece to the back side of the manifold (A), applying firm pressure to the entire piece.
4. Remove the remaining wax paper from the
double-sided mounting tape (C) and adhere it to the cleaned wall surface, applying firm pressure to the entire piece.
Fig. 4
(B) Screw
(A) Manifold
(C) Mounting tape
(A) Manifold
Fig. 5
Installation Instructions
8
INSTALLING THE TUBING
1. Measure 3/4from the end of each remaining piece
of tubing (faucet end and inlet end) and mark with a pencil (Fig. 6). (Check for roundness, smoothness, cuts, nicks, flat spots and sharp edges. It may be necessary to recut the tubing.)
2. Observe arrows on top of manifold that indicate
inlet and outlet. Failure to follow will result in water leaks when filter canister is removed.
3. Push the tubing firmly into each fitting on the
manifold until the line is flush with the fitting collar. (If the tubing is removed, re-cut the end, measure, mark and re-insert). Tubing must be fully inserted to avoid leaks (Fig. 7). (To remove tubing, depress and
hold white collet; pull tubing out to remove.)
4. Pull out slightly on tubing to ensure a good seal.
5. Install the other end of the tubing from the inlet side
of the manifold to the feed water adapter.
NOTE: Inspect the ends of the tubing to be sure there are no imperfections and that the end of the tubing is cut square. It may be necessary to cut the tubing again.
3/4
(19 mm)
Fig. 6
INCORRECT
INSTALL THE BATTERY
1. Remove the lens cover from the faucet base.
Grip it from both sides and pull forward.
2. Install one CR2032 3V battery with the “+” side
down into the battery tray.
3. The amber LED light will flash 5 times, indicating
a proper installation and system reset. If the amber light does not flash, check the position of the battery and make sure it is installed correctly.
4. Slide the lens cover back into the faucet base.
5. Normally, the light is off. After 6 months of use,
the amber LED light will flash every 30 seconds, indicating the time to replace the filter canister.
NOTE: The amber LED light may stop blinking if it is allowed to blink for an extended period of time. To ensure proper operation, the battery should be replaced with every filter change.
Faucet Base
Lens Cover
Battery “+” Side Down
3
4
"
Engagement
3/4(3/8tubing)
White Collet (DO NOT REMOVE)
Insertion line
Insert tubing
Fig. 7
Installation Instructions
9
REPLACING THE FILTER CANISTER
The amber light in the faucet base will flash every 30 seconds to indicate a filter change is needed. This occurs every 6 months. TO PROPERLY MAINTAIN SYSTEM, CHANGE FILTER AS REQUIRED.
1. Remove the filter canister from the manifold by
rotating the canister to the left about 1/3 turn (Fig. 9). NOTE: A small amount of water from the tubing between the filter and the faucet may come out. A small towel should be able to catch it.
2. Remove foil on top of new replacement filter
canister. Install the new canister into the manifold by turning it to the right about 1/3 turn until the alignment marks line up and the filter stops. DO NOT OVERTIGHTEN. The filter will rise up as it is turned.
3. Turn handle on faucet to allow trapped air to purge
from the system.
NOTE: System may make noise during this procedure.
4. Check for water leaks around the system.
5. Once water starts to flow out of the faucet, allow the
system to run for 4 gallons (or 5 minutes) to flush out any harmless carbon fines that may be present.
6. Turn off faucet and check around system for leaks.
7. Remove battery tray and replace battery to reset
timer. (See Battery Installation for proper procedure.)
Replacement Filter Canister/ Estimated Replacement Costs
GXRLQR—Replacement filter canister $30–35 For replacement parts, call toll-free 800.626.2002
(U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French).
FLUSH PROCEDURE
Whenever water of unknown quality is passed through the GE Water Filtration system, the filter canister should be discarded and the filtration system flushed.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
Circumstances that may require flushing the system are:
Boil water advisory
Flooding of the GE Water Filtration system
Long-term non-use
The procedure for flushing the GE Water Filtration system is:
1. See Replacing the Filter Canister section and follow
steps 1–5.
To install To remove
Fig. 9
10
Before you call for service…
Problem Possible Causes What To Do
Water contains tiny New filter canister contains Turn on the filtered water faucet and allow to run for 4 gallons black particles activated carbon. (or 5 minutes) to flush out any harmless carbon fines that may
be present.
Water has air bubbles Air in system after installation. Will go away after water runs for a while. and is cloudy
Indicator light on the Six months usage has occurred. Replace both filter canister and battery in the faucet base. faucet base is flashing This is the maximum life of
the filter canister.
Indicator light on the Normal operation. Does not blink until 6 months of operation has passed. faucet base is not blinking
Battery may need to be replaced. Normally the light is not on. The light blinks every 30 seconds to
indicate a filter change is needed. This occurs about every 6 months.
Replace battery. Indicator light will blink rapidly 5 times to indicate
proper installation and operation.
Indicator light on the Battery may need to be Observe orientation markings on the holder. Install with battery faucet base is not
replaced or it may have been “+” side down.
working
when new installed incorrectly.
battery is installed
Chlorine taste and odor The filter canister is no
Replace the filter canister.
in the product water longer reducing chlorine
taste and odor from the water supply.
Water dispenses The filter has been installed A six-month change-out period is recommended. Replace the very slowly
for too long. filter canister.
The filter canister has High sediment levels can cause premature clogging. Replace the become clogged. filter canister.
Fittings are leaking Tubing may not be installed Fully follow the installation instructions and be sure the tubing is
properly. free of nicks, burrs, etc., and is installed to the proper depth.
No water dispensing Filter canister not fully installed. Fully follow the filter replacement instructions. from system