GE GTDL200GM1WW Installation Guide

Installation J GasDrger l@ ®
Instructions 08
Questions on Installation? Call: 800.GE.CARES (US) or 800-561-3344 (Canada) J
or visit our web site at: www.GEAppliances.corn (US)
I
BEFORE YOU BEGIN
Read these instructions
completely and carefully.
these instructions for local inspector's use.
IMPORTANT- Observe
all governing codes and ordinances.
Note to Installer - Be sure to leave these instructions with
the customer.
Note to Customer- Keep these instructions with your Owner's
Manual for future reference.
Before the old dryer is removed from service or discarded,
remove the dryer door.
Inspect the dryer exhaust outlet and straighten the
outlet walls if they are bent.
Service information and the wiring diagram are located in
the control console.
Do not allow children on or in the appliance. Close
supervision of children is
necessary when the appliance is used near children.
Install the dryer where the
WARNING RISKOF FIRE
To reduce the risk of severe injury or death, follow all installation instructions.
Clothes dryer installation must be performed by a qualified installer.
Install the clothes dryer according to these instructions and in accordance with local codes.
California Safe Drinking Water and Toxic Enforcement Act This act requires the governor of California to publish a list of substances known to the
state to cause cancer, birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances. Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.
This dryer must be exhausted to the outdoors.
Use only rigid metal 4" diameter ductwork inside the dryer cabinet and use only UL approved transition ducting between the dryer and the home duct.
DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semirigid or foil-type) duct is installed, it must be UL listed and installed in accordance with the instructions found in "Connecting The Dryer To House Vent" on page 5 of this
manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire.
Do not install or store this appliance in any location where it could be exposed to water and or weather.
Save these instructions. (Installers: Be sure to leave these instructions with the customer).
This product must be installed bLIa licensed plumber or gas fitter.
When using ball-type gas shut-off valves, they shall be the T-handle tLIpe.
A flexible gas connector, when used, most not exceed 3feet.
temperature is above 50°F for satisfactory operation of the
dryer control system.
Product failure due to improper installation is not
covered under the Warranty.
TOOLS YOU WILL NEED
10"ADJUSTABLEWRENCHES
R" DID_ \AI_EICH
Step i
Verify your gas installation (seesection 2).
Step 2
Prepare the area and exhaust for installation of new dryer (seesection 1).
Step 3
Check and ensure the existing external exhaust is clean (see section 1)and meets attached installation specifications (see
section 6).
Step 4
Remove the foam shipping pads (see section 1).
Step 5
Move the dryer to the desired location.
Step 6
Level your dryer (seesection 8).
Step 7
Connect the gas supply (seesection 3) and check for leaks (seesection 4). Connect the external exhaust (seesection 7).
Step 8
(x2)
FLATBLADESCREWDRIVER
SLIPJOINTPLIERS
IN THE COMMONWEALTH OF MASSACHUSETTS
MATERIALS YOU WILL NEED
%
4"DIA.METALDUCT
(RECOMMENDED}
4"DIA.FLEXIBLEMETAL(SEMFRIGID}
ULLISTEDTRANSITIONDUCT
KiTWXO8X10077(iNCLUDES2ELBOWS}
4"DIA.FLEXIBLEMETAL(FOILTYPE}
(IFNEEDED}
ULLISTEDTRANSITIONDUCT
(IFNEEDED,}
Step 9 Connect the power supply (see section 5). Step 10 Check the operation of the power supply, gas connections,
Step 11 Place the Owner's Manual and the Installation Instructions in
For alcove or closet installation, see section 9. For bathroom or bedroom installation, see section 10. For mobile or manufactured home, see section 11. For garage installation (ifallowed by local codes), see section 12. For side or bottom exhaust, see section 13.
4"DIA.METAL
ELBOW
4"DUCT
CLAMPS(2}
OR
4"SPRING
CLAMPS(2}
and venting.
a location where they will be noticed by the owner.
EXHAUST
HOOD
FLEXIBLEGASLINECONNECTOR GLOVES
COMPOUND SOAPSOLUTION
DUCTTAPE SAFETY
234D1582PO08 31-16679 03-12 GE
PIPE
FORLEAKDETECTION
GLASSES
Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in.clearance both sides and 1in. rear.Consideration must be given to provide adequate clearance for installation and service.
m PREPARING FOR INSTALLATION
OF NEW DRYER
TIP:Install your dryer before installing your washer. This will allow better access when installing dryer exhaust.
DISCONNECTING GAS
TURNGAS _ DISCONNECTANDDISCARDOLu_ _ SHUT-OFF Js_-._ FLEXIBLEGASCONNECTORAND ,_
VALVETOTHE _ OLD DUCTINGMATERIAL.
APPROVEDFLEXIBLEGASLINE CONNECTORAND ULAPPROVED
TRANSITIONDUCT.
WARNING - NEVERREUSEOLD
FLEXIBLE CONNECTORS.
The use of old flexible connectors can cause leaks and personal injury. Always use new flexible
connectors when installing gas appliances.
REMOVING LINT FROM WALL EXHAUST
OPENING
Removeand discard existing plastic or metal foil transition duct and replace with ULlisted transition duct.
[] GAS REQUIREMENTS
WARNING
Installation must conform to local codes and ordinances,or in their absence, the NATIONALFUELGAS CODE,ANSIZ223.
This gas dryer is equipped with aValve & Burner
Assembly for useonly with natural gas. Using conversion
kit WE25X0217,your local service organization can convert this dryer for usewith propane (LP)gas. ALL
CONVERSIONSMUSTBEMADEBYPROPERLYTRAINED
AND QUALIFIEDPERSONNELANDIN ACCORDANCEWITH
LOCALCODESAND ORDINANCEREQUIREMENTS.
The dryer must be disconnected from the gas supply piping system during any pressure testing of that sys-
tem at a test pressure in excess of 0.5 PSI(3.4 KPa).
The dryer must be isolated from the gas supply piping system by closing the equipment shut-off valve during
any pressure testing of the gas supply piping of test pressure equal to or less than 0.5 PSI(3.4 KPa).
DRYER GAS SUPPLY CONNECTION
WALL
/
INTERNALDUCT OPENING IDDAMPEROPENS
CHECKTHATEXHAUST
ANDCLOSESFREEL_
TILTTHE DRYERSIDEWAYS AND REMOVETHE FOAM SHIPPING PADS BY PULLING ATTHE SIDES
AND BREAKING THEM AWAY FROM THE DRYER LEGS. BESURETO REMOVEALL OF THE FOAM PIECESAROUND
THE LEGS.
' 3/8" NPT MALETHREAD GAS SUPPLY
NOTE:Add to vertical dimension
the distance between cabinet
bottom to floor.
A 1/8 in. National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to
the dryer.Contact your local gas utility should you have
questions onthe installation of the plugged tapping.
Supply line is to be 1/2 in.rigid pipe and equipped with an accessible shut-off within 6ft. of,and inthe same
room with the dryer.
Use pipe thread sealer compound appropriate for natu- ral or LPgas or use Teflon tape.
You must use with this dryer aflexible metal connector (listed connector ANSIZ21.24 / CSA6.10). The length of
the connect shall not exceed 3 ft.
Connectflexible metal connector to dryer and gassupply.
Open shut-off valve.
ADJUSTING FOR ELEVATION
Gas clothes dryers input ratings are based on sea level operation and need not beadjusted for operation at or
below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings
should bereduced at a rate of 4 percent for each 1000 ft. above sea level.
Installation must conform to local codes and ordinances or, in their absence,the NATIONALFUELGASCODE,ANSIZ223.
Installation Instructions
RECONNECTING GAS
Listed connector ANSI Z2!.24 / CSA 6.!0
1/8" NPTPIPE
NEWMETAL GAS FLEXIBLEGAS INLETPRESSURE LINECONNECTOR
ADAPTER SHUT-OFF
3/8" NPT VALVE
ELBOW
ITEMSNOT SUPPLIED AT LEAST1/2"
NOTE:The connector ond fittings (]re designed for use only on the originol instollotion ond (]re not to be reused for onother opplionce or ot onother Iocotion. Keepfiore end of °doptor free of greose, oil ond threod seolont.
PLUGFOR
__ PIPESIZE
I
APPLYPIPECOMPOUND TOALL MALETHREADS.
CAUTION: UseodoptorsosshownConnector
nuts must not be connected directly to pipe threads.
\
APPLYPIPECOMPOUND
TOTHEADAPTERAND
DRYERGASINLET.
Tighten the flexible gas line using two adjustable wrenches.
Tighten oil connections using two adjustable wrenches. Do not overtorque gas connections!
14]LEAK TEST
_ZLWARNING- NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
GASVALVE.
OPEN
Check all connections for leaks with soupy solution or equivalent. Apply soup solution. Leek test solution must not contain ammonia which could cause damage to the brass fittings. Ifleaks are found, close valve, retighten the
joint, and repeat the soup test.
Loading...
+ 5 hidden pages