GE GTD72GBPNDG, GTD72GBSNWS Specifications

Page 1
GTD72GBSN/GBPN
GE® 7.4 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer With HE Sensor Dry
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
EXHAUST OPTION: When viewed from the front
of the unit, exhaust 3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting knockouts are supplied.
GAS: An individual, properly-grounded branch circuit, with a three-prong grounding-type receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.
GAS DRYER ELECTRIC RATING: 120V, 60Hz, 6A
GAS (BTU/HR): 22,000. Factory-equipped for
natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation.
NOTE: Dryer wall outlet must be located within 36" of service cord entry and accessible when dryer is mounted in position.
INSTALLATION INFORMATION : For complete information, see installation instructions packed with your dryer.
SPECIAL INSTALLATION REQUIREMENTS ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces
are: 0" either side; 1" front, top and rear
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a ga s dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local
codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION :
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear
DRYER EXHAUSTING INFORMATION :
- Use metal duct only, vertical and horizontal ducting.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Speci fication Create d 7/19
Page 2
GTD72GBSN/GBPN
22 1/2"
30 1/2"
27"
3 1/2"
1 3/4"
3 1/4"
8"
38 1/2"
46"
27"
5"
Power Cord 4 1/2"
11 3/4"
Side View Rear View
5
Back View
Power Cord Hole
4-1/2
GE® 7.4 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer With HE Sensor Dry
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
POWER CORD LOCATIONS
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Speci fication Create d 7/19
Page 3
GTD72GBSN/GBPN
GE® 7.4 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer With HE Sensor Dry
FOR COMPLETE INFORMATION, SEE INSTALLATION INSTRUCTIONS PACKED WITH YOUR DRYER.
DUCTING MATERIALS:
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained throughout the entire length of the transition duct. Please see installation instruction packed with your dryer for complete instructions when using flexible metal (foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES, PLEASE CALL 1-800-GE-CARES.
DRYER EXHAUSTING INFORMATION— USE METAL DUCT ONLY VERTICAL AND HORIZONTAL DUCTING
BEST PERFORMANCE
Maximum length of 4" dia rigid metal duct
Exhaust hood t ype
Number
Domestic dryer models
Long Vent 6.1-7.4 cu. ft. capacity electric & gas (GTD33, GTD42, GTD45, GTD65, GTX22, GTX33, GTX42 and GTX65)
For every extra 90° elbow, reduce the allowable vent system length by 10 ft. Two 45° elbows will be treated like one 90° elbow. For the side exhaust installations, add one 90° elbow to the chart. When calculating the total vent system length, you must add all the straight portions and elbows of the system (including the transition duct.
of 90°
turns
0 120 ft. 90 ft.
1 100 f t. 75 f t. 2 85 ft. 65 ft. 3 70 ft. 55 ft. 4 60 f t. 45 ft. 5 55 ft. 35 ft.
A
4"
opening
B
2-1/2"
opening
Speci fication Create d 7/19
Page 4
GTD72GBSN/GBPN
Est. Time Remaining
WARM UP
SANITIZE
BULKY
Comforter
DELICATES
JEANS AIR FLUFF
TIMED DRY
TOWELS
Sheets
CASUALS
QUICK DRY
MIXED LOAD
COTTONS
Normal
Wrinkle
Care
ecoDry
More Time
Less Time
Delay Dry
Sound
My
Cycle
Damp Alert
Time Level Temp
Damp
Less Dry
Dry
More Dry
No Heat
Medium
Low
High
60
10
20
40
90 min.
Delay Drying Cooling Done
Drum Light*
Control Lock*
Save My Cycle*
* Hold 3 Seconds
Time Dry Cycles
G
T
D
7
2
E
(
G
)
B
S
N
W
S
,
G
T
D
7
2
E
(
G
)
B
P
N
D
G
2
3
4
D
2
2
9
8
P
0
1
0
R
E
V
.
1
1
,
2
3
4
D
2
3
1
3
G
0
1
0
,
2
3
4
D
2
4
5
6
G
0
1
0
/
G
0
1
1
GE® 7.4 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer With HE Sensor Dry
FEATURES AND BENEFITS
HE Sensor Dry – Prevent over-drying and get more wear out of your clothing thanks to innovative dual thermistor technology, that continually monitors temperature and moisture in the dryer.
Up to 120 ft. venting – Maximize your dryer’s performance with innovative venting, designed to provide optimal airflow, enhanced drying ability, and flexible installation.
Wrinkle Care – Spend less time ironing thanks to an innovative wrinkle care system that allows you to tumble clothes without heat to reduce creasing.
My Cycle Settings – Streamline your laundry by choosing your favorite dryer settings on any cycle and saving them for future use.
Quick Dry – Dry a full load in less time thanks to innovative quick dry technology.
Damp Alert – Be notified when clothes are the ideal dampness to remove from the dryer for wrinkle-free results.
Dry Level Options – Four different drying levels to dry the way you want.
Temperature Options – Four different temperatures for full control over the drying process.
Sanitize Cycle – Reduce certain types of bacteria by 99.8% with this cycle.
Warm Up – Quickly warm up your clothes and release set wrinkles.
ENER GY STAR® qualified - Meets or exceeds federal guidelines for energy efficiency for year-round energy and money savings
Check Vent Alert - Ensure optimal drying performance with this notification to alert you when your dryer vent needs to be cleaned.
Model GTD72GBNSWS – White with silver backsplash
Model GTD72GBPNDG – Diamond Gray
Speci fication Create d 7/19
Loading...