GE GIE21GSHBSS, GIE21GSHCSS, GIE21GTHBBB, GIE21GTHBWW, GIE21GTHCBB Installation Guide

...
GE Appliances
LIS Internal Use Only
Part Install Instructions
Breaker Trip Kit WR49X27506
!
The information in this part instruction is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
IMPORTANT SAFETY NOTICE
Parts Included:
PTC starter (relay) - WR55X22042
Overload Protector-
Instruction Sheet
WR87X27188
!
To avoid personal injury, disconnect power before servicing this appliance. If electrical power is required for diagnosis or test purposes, disconnect the power immediately after performing the necessary checks. RECONNECT ALL GROUNDING DEVICES If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened.
Tools Required:
Phillips head screwdriver
¼” nut driver
Small flat blade screwdriver
WARNING
Following steps cover the repair for branch circuit AFCI or AFCI+GFCI dual function circuit breakers tripping with 21 Cu Ft top freezer refrigerators.
Step 1- Disconnect power to the refrigerator.
Step 2- Remove the rear access cover by removing six ¼‘” hex head screws.
Step 3- Remove three Phillips head screws from the protector cover.
GE Appliances
Louisville, KY 40225
1
Continued…
WR00X27596
Step 4- Remove the plastic wire holder. A small screwdriver may help to pry the holder from the cover.
LIS Internal Use Only
Wire holder
Step 5- Remove the protector cover.
Rotate the back of the cover to the left.
Then rotate the top of the cover away from the compressor.
Step 6- Remove the PTC by pulling the relay to the left of the compressor. DO NOT pry or wiggle the PTC side to side to remove, this can damage compressor pins. Disconnect wires and discard the PTC.
Step 7- Remove the overload by pulling the overload to the left of the compressor and replace with the new overload.
Step 8- Connect the wires to the new startup relay.
Pin 1-White Pin 2-Blue Pin 3-Brown Pin 4-not used
Step 9- Connect the new relay to the compressor.
Step 10- Place the wires into the groove of the relay cover and slide the cover into place.
2
1
4
3
GE Appliances
Louisville, KY 40225
2
Continued…
WR00X27596
Loading...