GE GFDN120GD Specification

GFDN120GD

GE® 7.0 Cu. Ft. Capacity Frontload Gas Dryer

Dimensions and Installation Information (in inches)

Gas Dryer Rating

120V 60Hz, 6A

Exhaust Options: 3-way via rear, left, and bottom.

Circuit Requirements: An individual, properly grounded branch circuit, protected by a 15-20 amp circuit breaker or a time-delay fuse, is required.

Note: Dryer wall outlet must be located within 36” of service cord entry and accessible when dryer is mounted in position.

Installation Information: For complete information, see installation instructions packed with your dryer.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.

2732-3/16

39-3/8

4-3/8 4-1/2

Above illustration intended for dimensional reference only.

Refer to photography for actual product appearance.

2-1/2

 

3-1/2

 

 

1-3/4

Gas Pipe

Electrical

12

Connection

Connection

Specification Revised 4/15

GE GFDN120GD Specification

GFDN120GD

GE® 7.0 Cu. Ft. Capacity Frontload Gas Dryer

Special Installation Requirements:

Stacked Dimensions (in inches)

Stacked Installation:

24

3-1/4

49-5/8

• Brackets for stacking dryer over washer are not included with the dryer.

1/2

 

 

 

 

GEFLSTACK or part no. WE25X10018.

 

 

 

Alcove or Closet Installation:

 

 

 

• If your dryer is approved for installation in an alcove or closet, it will be

 

 

 

stated on a label on the dryer back.

 

 

 

• The dryer MUST be exhausted to the outside.

 

 

79-5/8

• Minimum clearances between dryer cabinet and adjacent walls or other

 

 

 

surfaces are: 0" either side, 3" front and rear

 

 

 

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

 

 

 

• Closet doors must be louvered or otherwise ventilated and must contain a

 

 

 

minimum of 60 sq. in. of open area equally distributed. If this closet contains

 

 

 

both a washer and a dryer, doors must contain a minimum of 120 sq. in. of

 

 

 

open area equally distributed.

 

 

 

No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

The dryer MUST be exhausted to the outdoors.

The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code,

ANSI Z223 for gas dryers.

Minimum Clearance other than Alcove or Closet Installations:

• Minimum clearances to combustible surfaces 0" both sides, 3" rear.

For more information on venting kits and accessories, please call 1-800-GE-CARES.

Pedestal Dimensions (in inches) SBSD137HWW - white

This optional 13" pedestal raises the door opening and height of the washer or dryer. Feet on 13"

pedestal allow it to adjust to 27

13-3/8" height.

13

 

Above illustrations intended for dimensional reference only.

28-3/4

 

Refer to photography for actual product appearance.

 

For answers to your Monogram,® GE Profileor

 

GE® appliance questions, visit our website at

 

geappliances.com or call GE Answer Center®

Specification Revised 4/15

service, 800.626.2000.