GFDL110EH
GE Appliances 7.0 Cu. Ft. Capacity
Electric Dryer With 200-Ft. Long Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRIC DRYER RATING |
27 |
32-3/16 |
|
|
120V/240V 5600W, 24A, 60Hz
120V/208V 4400W, 22A, 60Hz
EXHAUST OPTIONS: 3-way via rear, right and bottom.
CIRCUIT REQUIREMENTS: An individual, properly |
39-3/8 |
|
grounded branch circuit, protected by a 30-amp circuit breaker |
|
|
or a time-delay fuse, is required. |
|
|
NOTE: Dryer wall outlet must be located within 36" of service |
|
|
cord entry and accessible when dryer is mounted in position. |
|
|
INSTALLATION INFORMATION: For complete information, |
4-3/8 |
|
see installation instructions packed with your dryer. |
||
4-1/2 |
||
|
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or |
|
GE Appliances product questions, visit our website at geappliances.com |
|
or call GE Answer Center® Service, 800.626.2000. |
Specification Revised 1/16 |
GFDL110EH
GE Appliances 7.0 Cu. Ft. Capacity Electric Dryer With 200-Ft. Long Venting
SPECIAL INSTALLATION REQUIREMENTS: STACKED INSTALLATION:
Brackets for stacking dryer over washer are not included with the dryer. GEFLSTACK or part no. WE25X10018.
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear.
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATIONS:
Minimum clearances to combustible surfaces 0" both sides, 3" rear.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES, PLEASE CALL 1-800-GE-CARES.
STACKED DIMENSIONS |
|
||
(IN INCHES) |
|
||
24 |
49-5/8 |
|
|
3-1/4 |
1/2 |
||
|
|||
|
|
79-5/8 |
2-1/2 |
|
3-1/2 |
|
|
|
1-3/4 |
Gas Pipe |
Electrical |
12 |
Connection |
Connection |
PEDESTAL DIMENSIONS (IN INCHES)
SBSD137HWW - WHITE
This optional 13" pedestal |
27 |
raises the door opening and |
|
height of the washer or dryer. |
|
Feet on 13" pedestal allow |
13 |
it to adjust to 13-3/8" height. |
|
28-3/4
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
Specification Revised 1/16