GFD48GSSK/GSPK
GE Appliances 8.3 cu. ft. capacity Front Load gas ENERGY STAR® Dryer with steam
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
GAS DRYER RATING
120V 60Hz, 6A
EXHAUST OPTIONS: 3-way via rear, left, and
bottom.
CIRCUIT REQUIREMENTS: An individual,
properly grounded branch circuit, protected by a
15-20 amp circuit breaker or a time-delay fuse, is
required.
NOTE: Dryer wall outlet must be located within
36" of service cord entry and accessible when dryer
is mounted in position.
INSTALL AT ION INFOR M AT ION: For complete
information, see installation instructions packed
with your dryer.
28
34-3/8
39-2/5
3-5/8
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Speci fication Created 8/16
GFD48GSSK/GSPK
GE Appliances 8.3 cu. ft. capacity Front Load gas ENERGY STAR® Dryer with steam
SPECIAL INSTALLATION REQUIREMENTS
STACKED INSTALL AT ION :
Brackets for stacking dryer over washer are not included with the
washer. Order part no. GEFLSTACK or part no. WE25X10018.
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it will
be stated on a label on the dryer back.
The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side, 3" front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc.
is 52".
Closet doors must be louvered or otherwise ventilated and must
contain a minimum of 60 sq. in. of open area equally distributed. If
this closet contains both a washer and a dryer, doors must contain a
minimum of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet
with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence
of local codes, with the National Electric Code and National Fuel Gas
Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET
INSTALL AT IONS:
Minimum clearances to combustible surfaces 0" both sides, 3" rear.
FOR MORE INFORMATION ON VENTING KITS AND
ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
STACKED DIMENSIONS
(IN INCHES)
52"
2-1/4"
4-5/8"
25-3/8"
PEDESTAL DIMENSIONS (IN INCHES)
GFXP1308FWW - WHITE
GFXP1308FDG - DIAMOND GRAY
GFXP1308FRR - RUBY RED
This optional 13" pedestal raises the door
opening and height of the washer or dryer.
Feet on 13" pedestal allow it to adjust to
13-3/8" height.
13"
C
79-5/8"
27"
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
28-3/4"
Speci fication Created 8/16