GE Appliances 7.5 Cu. Ft. Capacity Frontload Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRIC DRYER RATING
120V/240V5600W, 24A, 60Hz
120V/208V4400W, 22A, 60Hz
EXHAUST OPTIONS: 4-way via rear, right,
left and bottom.
CIRCUIT REQUIREMENTS: An individual,
properly grounded branch circuit, protected by
a 30-amp circuit breaker or a time-delay fuse,
is required.
NOTE: Dryer wall outlet must be located within 36"
of service cord entry and accessible when dryer is
mounted in position.
INSTA L L ATION IN F O R MATION : For complete
information, see installation instructions packed
with your dryer.
27
33
39-3/8
4-3/8
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
5-3/8
Listed by
Underwriters
Laboratories
Speci fication Revised 6/16
Page 2
GFD45ESSK/ESPK
GE Appliances 7.5 Cu. Ft. Capacity Frontload Dryer
SPECIAL INSTALLATION REQUIREMENTS:
STAC K ED IN S TA LL ATION :
Brackets for stacking dryer over washer are not included with
the dryer. Order part no. GEFLSTACK or part no. WE25X10018.
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it will be
stated on a label on the dryer back.
The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side, 3" front and rear.
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet with
a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of
local codes, with the National Electric Code and National Fuel Gas Code,
ANSI Z223 for gas dryers.
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET
INSTA L L ATIONS :
Minimum clearances to combustible surfaces 0" both sides, 3" rear.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
STACKED DIMENSIONS
(IN INCHES)
24-7/8
50-5/8
3-1/2
3
PEDESTAL DIMENSIONS
(IN INCHES)
SBSD137HWW - WHITE
This optional 13" pedestal raises
the door opening and height of
the washer or dryer. Feet on 13"
pedestal allow it to adjust to
13-3/8" height.
39-3/8
27"
13"
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
28-3/4"
Listed by
Underwriters
Laboratories
Speci fication Revised 6/16
Page 3
GFD45ESSK/ESPK
2-1/2
12
Connection
Connection
GE Appliances 7.5 Cu. Ft. Capacity Frontload Dryer
DRYER EXHAUSTING INFORMATION –METAL DUCT ONLY
For complete information, see installation instructions packed with your dryer.
DUCTING MATERIALS: For best performance, this dryer should be vented with 4" diameter
all rigid metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible
metal (semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it may
be necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct. A
UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or
flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter can be maintained
throughout the entire length of the transition duct. Please see installation instruction packed
with your dryer for complete instructions when using flexible metal (foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust
to the side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated
is shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length
should be treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney, under any enclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard
or moisture could cause damage. Never terminate the exhaust into a common duct or plenum
with a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
A
4
Domestic
A
B
2-1/2
dryer models
7.5 cu. ft.
capacity models
electric dryers
Number
of
90°
turns
0
1
2
3
4
Best performance
Maximum length of 4"
dia. rigid metal duct
Exhaust hood type
A
4"
opening
90 ft.
60 ft.
45 ft.
35 ft.
25 ft.
B
2-1/2"
opening
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
1-3/4
Gas Pipe
3-1/2
Electrical
Listed by
Underwriters
Laboratories
Speci fication Revised 6/16
Page 4
GFD45ESSK/ESPK
GE Appliances 7.5 Cu. Ft. Capacity Frontload Dryer
FEATURES AND BENEFITS
Steam Refresh - Rejuvenate lightly worn clothes by getting rid of wrinkles and odors with
this convenient setting using the power of steam
Steam Dewrinkle - Stored or wrinkled clothes come out wrinkle-free with this helpful setting
that uses steam to refresh and dry a load of any size
HE Sensor Dry - Takes the guesswork out of drying times by sensing the moisture in the
drum and drying accordingly
Stainless steel drum - Resists rust and helps protect clothes
Quick Dry - Quickly dries items and small loads for families on the go
Sanitize cycle - This option reduces certain types of bacteria by 99.8%
Damp Alert - Alerts you when clothes are the ideal dampness for ironing, for perfectly
wrinkle-free results
Extended Tumble - Tumble clothes without heat to help prevent creasing and wrinkling
Model GFD45ESSKWW – White
Model GFD45ESPKDG – Diamond Gray
Perm Press
Mixed Loads
Towels
Cottons
Delicates
Bulky
Bedding
Casuals
Quick Dry
Drying Damp Cool Down Complete
Sheets
Estimated Time Remaining
Steam
Dewrinkle
Full Loads
Warm
Control
Up
Air Flu
No Heat
Add
Time
Time
Dry
High
More Dry
Medium
Dry
Low
Extra Low
Temp Level
Ext Tumble
Wrinkle Care
Less Dry
Damp
Lock ControlsVolume
Hold 3 Sec
Clean Filter
Speci fication Revised 6/16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.