GFD14ESSNWW
*33-1/4"
(84.5 cm)
(64.1 cm)
25-1/4"
(108.7 cm)
42-13/16"
18-1/10"
(45.9 cm)
23-7/16"
(59.5 cm)
*33-1/4"
(84.5 cm)
Front View Side View
®
GE
4.3 Cu.Ft. Capacity Electric Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRIC DRYER RATING
240V 2800W, 12A, 60Hz
CIRCUIT REQUIREMENTS: An individual,
properly grounded branch circuit, protected by
a 30-amp circuit breaker or a time-delay fuse, is
required.
NOTE: Dryer wall outlet must be located within
36" of service cord entry and accessible when dryer
is mounted in position.
INSTALLATION INFORMATION : For complete
information, see installation instructions packed
with your dryer.
Front View Side View
(108.7 cm)
42-13/16"
23-7/16"
(59.5 cm)
*33-1/4"
(84.5 cm)
Back View
20-1/2"
(52.1 cm)
(64.1 cm)
25-1/4"
18-1/10"
(45.9 cm)
Side View
*33-1/4"
(84.5 cm)
30"
(76.2 cm)
3-9/10"
(9.9 cm)
7-3/4"
(19.7 cm)
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
3"
(7.8 cm)
5-1/5"
(13.2 cm)
Speci fication Revised 3/19
GFD14ESSNWW
®
GE
4.3 Cu.Ft. Capacity Electric Dryer
SPECIAL INSTALLATION REQUIREMENTS:
ALCOVE OR CLOSET INSTALLATION:
Stacking Kit - GFA24KITL (not included)
If your dryer is approved for installation in an alcove or closet, it will be
stated on a label on the dryer back.
Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 1" left and right sides, 1" top, 3" front and rear.
Minimum clearances between washer cabinet and adjacent walls or other
surfaces are: 1" left and right sides, 1" top, 1" front and rear.
Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet
contains both a washer and a dryer, doors must contain a minimum of
120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet with
a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The installation must conform with the local codes, or in the absence of
local codes, with the National Electric Code and National Fuel Gas Code,
ANSI Z223 for gas dryers.
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET
INSTALLATIONS:
Minimum clearances to combustible surfaces 0" both sides, 3" rear.
FOR MORE INFORMATION ON VENTING KITS AND
ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
66 1/2"
STACKED DIMENSIONS (IN INCHES)
23 7/16" 25 5/8"
20 1/2"
3 3/8"
33 1/4"
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Speci fication Revised 3/19