GFV55ESSN
GE® Long Vent 7.8 cu. ft. Capacity Front Load Electric Dryer
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRIC DRYER RATING
120V/240V 5600W, 25A, 60Hz
120V/208V 4300W, 23A, 60Hz
EXHAUST OPTIONS: 4-way via rear, right,
left and bottom.
CIRCUIT REQUIREMENTS: An individual,
properly grounded branch circuit, protected by
a 30-amp circuit breaker or a time-delay fuse,
is required.
NOTE: Dryer wall outlet must be located within 36"
of service cord entry and accessible when dryer is
mounted in position.
INS TA LLATIO N INFO RMATIO N: For complete
information, see installation instructions packed
with your dryer.
28
32
39-3/4
3-5/8
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
6-1/8
R
Speci fication Revised 11/19
Listed by
Underwriters
Laboratories
GFV55ESSN
GE® Long Vent 7.8 cu. ft. Capacity Front Load Electric Dryer
SPECIAL INSTALLATION REQUIREMENTS:
STAC KED I NSTAL L ATION :
Brackets for stacking dryer over washer are not included with
the dryer. Order part no. GFA28KITN.
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it
will be label on the dryer back.
The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" all sides and top.*
Closet doors must be louvered or otherwise ventilated and must contain
a minimum of 60 sq. in. of open area equally distributed. If this closet
contains both a washer and a dryer, doors must contain a minimum
of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same closet
with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence
of local codes, with the National Electric Code and National Fuel
Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET
INS TA LLATIO NS:
Minimum clearances to combustible surfaces 0" both sides, 0" rear.
FOR MORE INFORMATION ON VENTING KITS AND
ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
STACKED DIMENSIONS
(IN INCHES)
54-1/2
"
PEDESTAL DIMENSIONS
(IN INCHES)
GFP1528PNDG - DIAMOND GRAY
GFP1528PNRS - SAPPHIRE BLUE
GFP1528PNSN - SATIN NICKEL
GFP1528SNWW - WHITE
This optional 16" pedestal raises
the door opening and height of the
washer or dryer.
79-1/2
28"
16"
*For improved per formance, a 1/2" clearance is suggested on each side.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
28-7/8"
Listed by
Underwriters
R
Laboratories
Speci fication Revised 11/19