BEFORE YOU BEGIN
Read these instructions completely and carefully.
MAX
WARNING/AVERTISSMENT
24
Volt
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground Tetra® power supply enclosure.
RISK OF FIRE
• Use only UL approved wire for input/output connections. Minimum size 18 AWG (0.82mm2)
• Follow all NEC and local codes.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [A] est conforme à la NMB-003 du Canada.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant l’inspection, l’installation ou le déplacement.
• Assurez-vous de correctement mettre à terre l’alimentation électrique Tetra®.
RISQUES D’INCENDIE
• N’utilisez que des ls approuvés par UL pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82mm2)
• Respectez tous les codes NEC et codes locaux.
Prepare Electrical Wiring
Electrical Requirements
• Acceptable for use in dry, damp and wet locations.
• The grounding and bonding of the LED Driver shall
be done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
• These products are only suitable for connection to a circuit from a Class 2 power source.
• These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies.
imagination at work
Components
1
5
2 3
4
UL approved 18 AWG (0.82 mm2) supply wire
1
UL approved 22-14 AWG (0.33-2.08 mm2) wire
2
connectors or 22-18 AWG (0.33-0.82 mm2) in-line/IDC connectors
#6 or #8 (M3 or M4) screws, 1/8 inch (3.2 mm)
3
rivets, or electronic grade silicone or equivalent
Tetra® 24 Volt Power Supply
4
Layout Modules
Clean and remove all debris
1
from the inside of the channel letter before you begin.
TC Measure Point
Measure and cut Tetra LED
2
strip to the appropriate length for each letter. Cuts can be made between any of the modules.
Tetra® MAX LED modules
5
3
Remove tape backing and stick LED modules into place. Continue until you have reached the end of the strip.
Use rivets, screws, or silicone
4
to secure at least every fth
LED module within the channel letter. Use #6 (M3) or #8 (M4) pan headed metal screws, 1/8-inch (3.2 mm) rivets, or silicone.
Drill a 1/4-inch (6.4 mm)
5 6
hole near the LED strip and grommet the hole for supply wire access.
NOTE: For halo-lit applications LED modules should be mounted on UL recognized clear acrylic or polycarbonate. The light output from the LED system should be directed back into the sign enclosure. This will allow for uniform backlighting of the sign and will provide simple mounting.
Clean and remove all debris from the inside of the channel letter. Replace sign face.