GE GEHTL-MPPR4-2NX1, GEHTL-HPPB4-2NX1, GEHTL-HPPR4-3NX1, GEHTL-HPPB4-3NX1, GEHTL-MPPR4-3NX1 Installation Manual

...
Arize ElementTM Top Light
Horticulture LED Lighting System
Installation Guide
BEFORE YOU BEGIN / AVANT DE COMMENCER
Read these instructions completely and carefully. Lisez attentivement ces instructions dans leur intégralité. For Commercial or Industrial use only.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power o before installation, inspection, cleaning or removal. And follow appropriate lock out/tag out safety procedure.
• Properly ground electrical enclosure.
• Follow all National Electric Codes (NEC) and local codes.
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
The installation and associated structures are subject to
approval by the authority having jurisdiction.
Use only with components identied in this document.
Suitable for dry, damp, and wet locations; Do not immerse any component.
Wear suitable Personal Protective Equipment (PPE) during
installation/maintenance. Highly recommend safety glasses,
helmet and leather glove for luminaire mounting.
• Luminaire design for Greenhouse only.
RISK OF FIRE
• Minimum 3 inch distance from light module & driver to any
combustible material.
Minimum 3 inch clearance between, light module & driver, light module & light module, driver & driver.
The light module shall be installed lens down with a minimum 5 inch distance to anything below.
All cables including connectors shall not be concealed or extended through a wall, oor, ceiling, or other parts of the building structure; located above a suspended ceiling or dropped ceiling; permanently axed to the building structure.
Cables shall be routed so that they are not subject to strain and are protected from physical damage; visible over their entire length; and used within their rated ampacity as
determined for the maximum temperature of the installed
environment specied in the instructions.
For safe operation, and to maximize the longevity of the luminaire; ensure that the light module and driver are clean and free of dirt, dust, oil, or any other debris prior to operation. Do not apply any kind of lm on the lens or
otherwise cover the driver or light engine in any way.
RISQUE DE CHOC ELECTRIQUE
Coupez l’alimentation avant l’inspection, l’installation ou la désinstallation.
Reliez correctement le boîtier électrique à la mise à la terre.
Suivre tous les codes électriques locaux applicables.
• Ce produit doit être installé selon le code d’installation
pertinent, par une personne qui connaît bien le produit et son fonctionnement ainsi que les risques inhérents.
L’installation et les structures associées sont soumises à l’approbation des autorités compétentes.
Utilisez uniquement avec les composants identiés dans ce document.
Convient aux endroits secs, humides et mouillés. Ne doit pas être immergé.
Portez les équipements de protection individuelle appropriés pendant l’installation et la maintenance. L’utilisation de
lunettes de sécurité, d’un casque et des gants de cuir pour le
montage du luminaire est fortement recommandée.
• Luminaire conçu pour serres seulement.
RISQUE D’INCENDIE
Distance minimale de 3 pouces entre l’équipement d’éclairage et toute matière combustible.
Distance minimale de 3 pouces entre tout équipement d’éclairage, module d’éclairage ou module d’alimentation.
Le luminaire doit être installé avec l'objectif pointé vers le bas avec une distance minimale de 5 pouces entre le luminaire et
tout objet.
Les câbles et connecteurs ne doivent pas être dissimulés à l’intérieur, ou passer à travers, d’un mur, d’un plancher, d’un plafond ou de toute autre partie de la structure du bâtiment; ne doivent pas être placés au-dessus d’un plafond suspendu; ne doivent pas faire partie intégrante de la structure du bâtiment.
Les câbles doivent être installés de façon à être protégés contre l’étirement et tout autre bris physique; visibles sur toute leur longueur; utilisés dans la limite de leur courant admissible, déterminée pour les limites de température de l’environnement spéciées dans le guide d’instruction.
• Pour une opération sécurisée et pour maximiser la longévité
du luminaire; S'assurer que le module d'éclairage et le module d'alimentation sont propres et sans saleté, poussière, huile ou autres débris avant l'opération. Ne pas appliquer tout type de lm sur les lentilles et ne pas couvrir le module d'alimentation ou le module d'éclairage de quelconque manière.
0°C
45°C
Suitable for operation in an ambient temperature between 32°F (0°C) and 113°F (45°C).
A mechanical ventilation or cooling system is
required to maintain the temperature within the growing space below 113°F (45°C) when the light
module is in operation.
1
Opération compatible avec un environnement à temperature ambiante controlée entre 32°F (0°C) et 113°F (45°C).
l’utilisation d’un système de contrôle de la température sera nécessaire pour garder la serre sous
les 113°F (45°C) lorsque le luminaire est en function.
Base Kit Components Supplied
1
Top Light module
1
Driver with brackets
2
2 x 0.8 ft. support cables with carabiners
3
2
3
Specications
Driver Input Ratings
Typical Operating
Voltages at
Description Detailed Description
GEHTL-HPPR4-2NX1 Top light 4 ft purple reproductive, 641W 120/208/240/277 5.3/3.1/2.7/2.3 > 0.9
GEHTL-HPPB4-2NX1 Top light 4 ft purple balanced, 641W 120/208/240/277 5.3/3.1/2.7/2.3 > 0.9
GEHTL-MPPR4-2NX1 Top light 4 ft purple reproductive, 345W 120/208/240/277 2.9/1.7/1.4/1.2 > 0.9
GEHTL-MPPB4-2NX1 Top light 4 ft purple balanced, 345W 120/208/240/277 2.9/1.7/1.4/1.2 > 0.9
GEHTL-HPPR4-3NX1 Top light 4 ft purple reproductive, 627W 277/347/480 2.3/1.8/1.3 > 0.9
GEHTL-HPPB4-3NX1 Top light 4 ft purple balanced, 627W 277/347/480 2.3/1.8/1.3 > 0.9
GEHTL-MPPR4-3NX1 Top light 4 ft purple reproductive, 337W 277/347/480 1.2/1.0/0.7 > 0.9
GEHTL-MPPB4-3NX1 Top light 4 ft purple balanced, 337W 277/347/480 1.2/1.0/0.7 > 0.9
GEHTL-EPPR4-1NX1 Top light 4 ft purple reproductive, 199W 120/208/240 1.7/1.0/0.8 > 0.9
GEHTL-EPPB4-1NX1 Top light 4 ft purple balanced, 199W 120/208/240 1.7/1.0/0.8 > 0.9
GEHTL-HPKR4-2NX1 Top light 4 ft pink reproductive, 646W 120/208/240/277 5.4/3.1/2.6/2.3 > 0.9
GEHTL-HPKB4-2NX1 Top light 4 ft pink balanced, 646W 120/208/240/277 5.4/3.1/2.6/2.3 > 0.9
GEHTL-HPKF4-2NX1 Top light 4 ft pink ower, 646W 120/208/240/277 5.4/3.1/2.6/2.3 > 0.9
GEHTL-HWTN4-2NX1 Top light 4 ft white industrial, 646W 120/208/240/277 5.4/3.1/2.6/2.3 > 0.9
GEHTL-MPKR4-2NX1 Top light 4 ft pink reproductive, 347W 120/208/240/277 2.9/1.7/1.5/1.3 > 0.9
GEHTL-MPKB4-2NX1 Top light 4 ft pink balanced, 347W 120/208/240/277 2.9/1.7/1.5/1.3 > 0.9
GEHTL-MPKF4-2NX1 Top light 4 ft pink ower, 347W 120/208/240/277 2.9/1.7/1.5/1.3 > 0.9
GEHTL-MWTN4-2NX1 Top light 4 ft white industrial, 355W 120/208/240/277 3/1.8/1.5/1.4 > 0.9
GEHTL-HPKR4-3NX1 Top light 4 ft pink reproductive, 632W 277/347/480 2.3/1.8/1.4 > 0.9
GEHTL-HPKB4-3NX1 Top light 4 ft pink balanced, 632W 277/347/480 2.3/1.8/1.4 > 0.9
GEHTL-HPKF4-3NX1 Top light 4 ft pink ower, 632W 277/347/480 2.3/1.8/1.4 > 0.9
GEHTL-HWTN4-3NX1 Top light 4 ft white industrial, 632W 277/347/480 2.3/1.8/1.4 > 0.9
GEHTL-MPKR4-3NX1 Top light 4 ft pink reproductive, 340W 277/347/480 1.2/1/0.8 > 0.9
GEHTL-MPKB4-3NX1 Top light 4 ft pink balanced, 340W 277/347/480 1.2/1/0.8 > 0.9
GEHTL-MPKF4-3NX1 Top light 4 ft pink ower, 340W 277/347/480 1.2/1/0.8 > 0.9
GEHTL-MWTN4-3NX1 Top light 4 ft white industrial, 347W 277/347/480 1.3/1/0.8 > 0.9
50/60Hz (VAC)
Input
Current (A)
Power Factor
2
Accessories
SKU Nomenclature Detailed Description Components
95047382 GEHAK-NN-FB-N0 Light module 2’ UL remote mount kit 2 X 2 ft support cable + 3 ft UL DC cable
95047404 GEHAK-NN-CC-N0 Light module 5’ UL remote mount kit 2 X 5 ft support cable + 6 ft UL DC cable
95047406 GEHAK-NN-DD-N0 Light module 10’ UL remote mount kit 2 X 10 ft support cable + 12 ft UL DC cable
95047408 GEHAK-DN-DD-N0 Driver 2¾” square member bracket 2 X 2¾” square brackets
95047409 GEHAK-BN-DD-N0 Driver 2¾” pipe member bracket 2 X 2¾” pipe brackets
95047410 GEHAK-AN-DD-N0 Driver 1 3/8” pipe member bracket 2 X 1 3/8” pipe bracket
95047411 GEHAK-NN-NE-N0 Driver universal 1’ remote mount kit 2 X 1ft driver support cable
95047654 GEHAK-NN-NN-J1 *Wire dimming junction box kit Junction box + 2 cable glands
95047660 GEHAK-NN-NN-D1 *UL wall-mounted dimming switch Dimming switch
*NOT AVAILABLE WITH 200W LIGHT MODULES (GEHTL-EPPR4-1NX1, GEHTL-EPPB4-1NX1)
ATTENTION / ATTENTION
Installation instructions and specications for accessories can be found in the accessory package.
Les instructions d’installation et spécications pour les accessoires se retrouvent dans le kit d’accessoires.
Sample Base Installation Diagram
Structural member
Structure
DRIVER
AC line
Plants
Top Light Module
DRIVER DRIVER
Support
Cable
Plants
Unistrut
3
Loading...